NOTICE OF VIOLATION I

i l

j Consumers Power Company Docket No. 50-155 I

As a result of the inspection conducted on July 11 through September 6,1988, and in accordance with the "General Policy and Procedure for NRC Enforcement 1

Actions," 10 CFR Part 2, Appendix C (1988), the following violation was l

)

identified:

i t

4 10 CFR Part 50, Appendix B, Criterion XI, states, in part that a test program l

shall be established to assure that all testing required to demonstrate that l

}

rystems and cemponents will perforra satisfactorily in service is identified W performed in accordance with written test procedures which incorporate the r;,quirements and acceptance limits contained in applicable design dor.uments, i

Contrary to the above, the licensee failed to assure that all testing required j

to demonstrate the newly installed Wide Range Monitors would perform satisfact>rily in service, in that, the instrutrents were not tested using s

detector current values which were appropriate to those found at ths l

facility, j

This is a Severity Level IV violation (Supplement I).

j The inspection showed that actions had been taken to correct the identified j

violation and to prevent recurrence. Consequently, no reply to the violation 1

is required and we have no further questions regarding this matter.

a f

I/Kl?8 V0$

aL I

Dated G. C. /rj$ht, Chief /