ML19351F230

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 801103-06
ML19351F230
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 12/02/1980
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19351F229 List:
References
50-155-80-16, NUDOCS 8101120016
Download: ML19351F230 (1)


Text

__

O Appendix A NOTICE OF VIOLATION Consumers Power Company Docket No. 50-155 As a result of the inspection conducted on November 3-6, 1980, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violation was identified:

10 CFR 20.203(b) states that each radiation area shall be conspicuously posted with a sign or signs bearing the radiation caution symbol and the words Caution - Radiation Area.

Contrary to the above, radiation areas in rooms 121 and 125 were not posted conspicuously with radiation area signs during this inspection.

This is a Severity Level V violation (Supplement IV).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within twenty-five days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance:

(1) corrective action taken and the results achieved; (2) corrective

~

action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.

Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.

c cc,.i t R /9f c

/~Mt

/

f"1A. B. Davis,'Chie.

Dated Fuel Facility and.

Materials Safety Branch 4

4

- - - _ _ - - - _ _ _ _ _ _ _. - -. _ - _ - _ _ _ _ - - - - - - _ - - _ _ _ _ _ _ - _ -. _ _ _ - -. _.. - _ -. - -.. _ - - - _ - _. _ - - - _ _ _. - -. _ - - _ _ _, _ - - _ _ - _ _ -. - _ _. - _ _ - _ -