Issue date | Title | Topic | |
---|---|---|---|
ML20202J847 | 14 February 1998 | Notice of Violation from Insp on 971205-980202.Violation Noted:Chemical Decontamination Worker Working Under RWP B982035 in High Radiation Area for Approx 55 Minutes & Did Not Monitor Dosimetry Time | High Radiation Area |
IR 07100008/2012004 | 17 December 1997 | Notice of Violation from Insp on 971008-1204.Violation Noted:On 971029,items Hanging from Spent Fuel Pool Rail Span 19 Had Combined Weight of 497 Pounds.Length of Time That Weight on Rail Exceeded Weight Restriction Not Determined | |
ML20199J457 | 19 November 1997 | Notice of Violation from Insp on 961216-971107.Violations Noted:Certain Radiation Surveys Required by Station Procedure RP-29,not Completed.Also Certain Radiation Survey Records Required to Be Maintained,Not Accurate | |
ML20211J734 | 6 October 1997 | Notice of Violation from Insp on 970902-05.Violation Noted: on 970902,maintenance Worker Preparing to Participate in Reactor Head Detensioning Operations Laid Down in Contaminated Area for Several Minutes | |
ML20217J339 | 12 August 1997 | Notice of Violation from Insp on 970303-0428.Violation Noted:On 970202 Rj Flowers,Employee of Consumers Power Co, Did Not Exit High Radiation Area After Receiving Alarm on Electronic Dosimeter as Required | High Radiation Area |
ML20217K552 | 12 August 1997 | Notice of Violation from Insp on 970303-0428.Violations Noted:Licensee Failed to Properly Evaluate Potential Radiological Hazards Associated W/Transfer of Highly Contaminated Filters | High Radiation Area |
ML20151J772 | 22 July 1997 | Notice of Violation from Insp on 970430-0616.Violation Noted:Inspector Identified That on 960403 & 970502,seven & Five CRDs Respectively Were Left After Insertion Time Testing W/Insert Speeds Greater than 28 | |
ML20140G885 | 10 June 1997 | Notice of Violation from Insp on 970313-0429.Violation Noted:Procedures Were Not Followed,In That Required Working Clearances & Protective Tagging Were Not Obtained by Workers Prior to Performing Work Activities | |
ML20135D443 | 24 February 1997 | Notice of Violation from Insp on 961130-970117.Violation Noted:Use of Inappropriate Surveillance Procedure Causing Uncontrolled Leak & Inline Relief Valve Lifting Due to Failure to Remove Installed Blank Flange | |
ML20134C942 | 29 January 1997 | Notice of Violation from Insp on 961019-1129.Violations noted:961108 Operators Closed EC Number 1 Loop Inlet Valve (MO-7062) Making Number 1 EC Loop Inoperable & Operability Test Number 2 EC Loop Outlet Valve Not Performed within 1 H | Fire Barrier Fire Watch |
ML20133C511 | 2 January 1997 | Notice of Violation from Insp on 961202-06.Violation Noted: High Radiation & Contaminated Areas Was Not Posted W/Signs Bearing Radiation Symbol | High Radiation Area |
ML20059C103 | 21 December 1993 | Notice of Violation from Insp on 931020-1214.Violation Noted:Results of Static Votes Testing at Final Asleft Torque Switch Setting for MO-7053 Were Not Evaluated Prior to Return to Svc of Valve | |
ML20059J954 | 9 November 1993 | Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 for Violations from Insp on 930824- 0914.Violations Noted:Control Rod Withdrawal Interlocks Test Not Accomplished in Accordance W/Procedure TR-96/T7-29 | |
ML20059G186 | 1 November 1993 | Notice of Violation from Insp on 931018-22.Violation Noted: Licensee Failed to Conduct 1991/1992 Requalification Program within Two Year Requirement | |
ML20057A127 | 8 September 1993 | Notice of Violation from Insp on 930809-20.Violation Noted: High Pressure Trip Setpoint Periodically Exceeded Limit of Less than or Equal to 2.2 Psig W/No Resulting Orderly Shut Down Being Performed | |
ML20126F932 | 24 December 1992 | Notice of Violation from Insp on Stated Dates.Violation: on 920214,radiation Protection Technician & Station Engineer Entered Recirculation Pump Room & Steam Drum Area W/O Taking Air Sample | |
ML20058G251 | 2 November 1990 | Notice of Violation from Insp on 900904-1015.Violation Noted:Three Individuals Failed to Initial Daily Entry Log Next to Name | |
ML20059N012 | 28 September 1990 | Notice of Violation from Insp on 900723-27 & 0806-10. Violations Noted:Procedure 77-EPS-202-13 Issued on 770822, Required Implementation of Coincident Logic in Diesel Generator Overcurrent Trip Circuitry | |
ML20245K085 | 14 August 1989 | Notice of Violation from Insp on 890710-0801.Violation Noted:On 890712,six Contaminated Items Stored in Normally Clean Areas within Plant Restricted Area,But Not Labelled W/ Contamination Levels,Contents & Date | |
ML20245E645 | 2 August 1989 | Notice of Violation from Insp on 890618-0724.Violations Noted:Failure to Complete All Required Entries on Radiation Work Permit Entry Log Sheet & Tools,Not Listed on Log Sheet, Found on Reactor Bldg Crane (Tool Control Area) | |
ML20154N468 | 22 September 1988 | Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $187,500.Noncompliance Noted:Failure to Qualify Equipment Important to Safety by Appropriate Testing &/Or Analysis | |
ML20154J799 | 16 September 1988 | Notice of Violation from Insp on 880711-0906.Violation Noted:Instruments Not Tested Using Detector Current Values Which Were Appropriate to Those Found at Facility Re Satisfactory Inservice Performance of wide-range Monitors | |
ML20151T196 | 5 August 1988 | Notice of Violation from Insp on 880602-0718.Violation Noted:Failure to Inspect Complete Disassembly,Repair & Reassembly Process of Single Valve & to Perform Dimensional Check of Diaphragms or Comparison Between Diaphragms | |
ML20196C324 | 27 June 1988 | Notice of Violation from Insp on 880523-27.Violation Noted: Maint Procedure MGP-14, Disassembly & Assembly of SMA-0 to SMA-4 Limitorques, Rev 3 & Prints Used for safety-related Valves Inappropriate to Circumstances | |
ML20236U054 | 25 November 1987 | Notice of Violation from Insp on 870831-1117.Violation Noted:As of Sept 1987,licensee Had Failed to Correct Administrative Weaknesses Identified During March 1987 QA Surveillance of Inservice Testing Program | |
ML20238D916 | 4 September 1987 | Notice of Violation from Insp on 870803-07.Violation Noted:On 870704 & 05,licensee Failed to Analyze Two Independent Samples & Verify Rate Calculations & Discharge Line Valving Prior to Initiating Planned Release | |
ML20214N407 | 21 May 1987 | Notice of Violation from Insp on 870128-0423 | |
ML20207J441 | 5 January 1987 | Notice of Violation from Insp on 861208-12 | |
ML20214F877 | 17 November 1986 | Notice of Violation from Insp on 860711-0923 | |
ML20212B700 | 1 August 1986 | Notice of Violation from Insp on 851209-860718 | Safe Shutdown Emergency Lighting |
ML20207J309 | 18 July 1986 | Notice of Violation from Insp on 860409-0710 | |
IR 05000730/2010031 | 24 February 1986 | Notice of Violation from Insp on 850730-1031 | |
ML20148L330 | 13 June 1980 | Notice of Violation from Health Physics Appraisal on 800303-14 | High Radiation Area |
ML20126E446 | 12 July 1977 | Notice of Violation from Insp on 770622-24 | Shutdown Margin |