LER 82-002/03L-0:on 820207,condensate Measuring Sys Breaker HVH-1 Tripped During Periodic Testing.Caused by Reverse Rotation Due to Missing Discharge Damper Louver.Reverse Rotation Stopped.Damper Repairs Underway
ML20042A571
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 03/09/1982
From: Cox H
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20042A564 List:
References
LER-82-002-03L, LER-82-2-3L, NUDOCS 8203230567
Download: ML20042A571 (3)


Text

U. S. NUCLE AR REGULATC RY COMMISSION l NRC FORM 366 (7 77)

. LICENSEE EVENT REPORT CON TROL BLOCK: l 1

l l l l l lh 6

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) o 1 lS lC lH lB lR l2 lg0 l0 l- l0 l0LICENSE 14 l0 l0 l0 l- l0 l0 l@l NUMBER 2b 4

26 l 1l 1l 1l 1[@lbi CATb8 LICENSE TYPE JO l lg 7 8 9 LICENSEE CODE 15 CON'T fb'lE8 "'" "'

n lL @l0 l5 l0 DOCKET l0 l0NUMBER l2 l6 l1 @l0 68 l2 l0EVENT 69 l7 l8DATE l2 l@l 0 l 3 l REPORT 74 75 0 l 9DATE l 8 l 280l@

7 60 61 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h O 2 lOn February 7,1982, at 1805 hours0.0209 days <br />0.501 hours <br />0.00298 weeks <br />6.868025e-4 months <br />, with the unit at 817. power, HVH-1 tripped during l o 3 lthe performance of Periodic Test (PT) 8.1 and was declared inoperhble. This event l o , lresulted in a degraded mode permitted by a Limiting Condition For Operation as defined l o 3 lby Technical Specification 3.3.2.2.a and is reportable pursuant to 6.9.2.b.2. The j O 6 l remaining HVH units were operating, and the containment spray pumps were demonstrated l o 7 l operable in accordance with 3.3.2.2.a so there was no threat to the public health and l 0 a Isafety. l 80 7 8 9 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE 7

O 9 8

l s la10l@ LE_J@ la_J@ l u l T i e l x i c l u l@ Lc_l@20U @

9 11 12 13 18 19

,_ SEQUENTIAL OCCURRENCE REPORT REVISION LE R EVENT YEAR REPORT NO. CODE TYPE NO.

@ ,ag/RO l8l2l

_ 21 22

[-j 23 l0l0l2l 24 26 y

27 l0 l3 l 28 29 W

30

[--j 31

[0_]

32 AK N AC O PL NT MET HOURS S8 IT D FOR B. SUPet 6 R MANUF CTURER J@[B_j@

33 34

(_Z_j@

35

[_Zj@

36 l0l0l0l0l 37 40

[Y_j @

43 W@ lAl@

42 43 l X l 9 l 9 l 947 l@

44 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l i l 0 l IFhe trip of HVH-1 was caused by reverse rotation as a result of the unit being shutdown]

i i la missing discharge damper louver allowed the other operatinn HVH units to cause a l 1 2 treverse air f1Ow through IIVH-1. The reverse rotation was stopped; HVH-1 was started I i a l satisfactorily and declared operable at 1637 hours0.0189 days <br />0.455 hours <br />0.00271 weeks <br />6.228785e-4 months <br /> on February 8, 1982. All necessary l i 4 l damper repairs will be performed during the refueling outage now in progress. i I 7 8 9 80 i STA  % POWER OTHER STATUS IS O RY DISCOVERY DESCRIPTION j i s W@ l 0l 8l 1l@l N/A l [B_j@l Operator Observation l ACTIVITY CO TENT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELE ASE i 6 N/A l N/A l 7 8 9

@ l10Zl@l 11 44 l

45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION i 7 10 l 0 l 0 l@l Z l@l N/A l PERSO~~El'm3u'JiES

~UMu n DESCniPriON@

, i a 1010101@l12 N/A I y 8 9 11 80 LOSS OF OR DAMAGE TO FACIL1TY TYPE DESCRIPTION

> 9 LZ_J@l N/A l P"" NRC USE ONLY

,9, DR0323O ADOg70 1 ,

PDR N/A 2 O l lllllllllllll$

7 8 0 . 68 69 80 ;E NAME OF PREPARER PHONE: l

SUPPLEMENTAL INFORMATIO_N FOR LICENSEE EVENT REPORT 82-02

1. Cause Description and Analysis On February 7, 1982, at 1805 hours0.0209 days <br />0.501 hours <br />0.00298 weeks <br />6.868025e-4 months <br />, with the unit at 81% power,llVH-1 breaker tripped on over-current during the performance of Periodic Test 8.1 (HVII Condensate Measuring System) and was declared inoperable.

This trip occurred immediately after HVH-1 was started. Initial investigation revealed that ilVII-l was rotating backwards which caused the over-current trip on unit startup. This reverse rotation was stopped, and IIVH-1 was started satisfactorily.

A thorough inspection of IITSI.-1-revealed a missing louver on the dis-charge damper, With IIVil-1 shutdown and the other HVII units opera-ting, this missing louver alloved air back flow through HVH-1 and caused the reverse rotation.

This event resulted in a degraded mode permitted by a Limiting Condition For Operation as defined by Technical Specification 3.3.2.2.a and is reportable pursuant to 6.9.2.b.2. The remaining HVH units were operating, and the containment spray pumps were demo;strated operable, so there was no threat to the public health and safety.

2. Immediate Corr,cctive Action In accordance with Technical Specification 3.3.2.2.a, the containment spray pumps were verified operable by performing Periodic Test 3.4A.

This test was completed at 2042 hours0.0236 days <br />0.567 hours <br />0.00338 weeks <br />7.76981e-4 months <br /> on February 7, 1982. As pre-viously stated, when the reverse rotation was stopped, llVH-1 was started satisfactorily.

A normal operating configuration for HVH-1 is running continuously.

Provided IIVH-1 is running, the missing louver does not present an operational (or safety) problem. In the event of a loss of onsite power,IIVH-1 is sequenced to start simultaneously with HVH-3 nnd prior to IIVH-2 and llVH-4. This would precluda reverse air flow through IIVH-1 from the other HVH units since they would not be operating.

Therefore, continued plant operation with IIVH-1 in its current con-figuration is not adverse to continued safe operation of the plant.

All licensed operators were informed of the special operational con-siderations concerning IIVH-1, and Operating Note 91 was issued to provide the required operator instructions. IIVH-1 was declared operable at 1637 hours0.0189 days <br />0.455 hours <br />0.00271 weeks <br />6.228785e-4 months <br /> on February 8, 1982.

tm

3. Corrective Actions to Prevent Recurrence Since the occurrence of this event, the plant has been shutdown for refueling.. During this outage. all of the HVH units will~be thoroughly inspected, and all necessary repairs will be made prior to plant startup. No further action is considered necessary, tm