UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 3, 2014 Mr. Fadi Diya Senior Vice President and Chief Nuclear Officer Ameren Missouri Callaway Energy Center P.O. Box 620 Fulton, MO 65251

SUBJECT:

SCHEDULE REVISION FOR THE SAFETY REVIEW OF THE CALLAWAY PLANT, UNIT 1, LICENSE RENEWAL APPLICATION (TAC NO. ME7708)

Dear Mr. Diya:

By letter dated December 15, 2011, Union Electric Company (Ameren Missouri) submitted an application pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 51 and 10 CFR Part 54, to renew operating license NPF-30 for the Callaway Plant, Unit 1 (Callaway),

for review by the U.S. Nuclear Regulatory Commission (NRC) staff. This letter is to inform you of a change in the safety review schedule for the Callaway license renewal review.

The staff is revising the following safety review milestone Decision - Director, Office of Nuclear Reactor Regulation, from TBD [To Be Determined] to 12/2014. The staff notes that the ACRS full committee meeting is scheduled to be held on October 2, 2014.

Enclosed is the staff's revised review schedule reflecting updates to the safety review for the Callaway license renewal application (LRA). The NRC will continue to follow established review procedures and the enclosed schedule to complete the reviews required by 10 CFR Part 54.

If you have any questions on the revised safety schedule, please contact Mr. John Daily, project manager for the Callaway LRA safety review, by telephone at 301-415-3873 or by e-mail at John.Daily@nrc.gov.

Sincerely,

/RA/

John W. Lubinski, Director Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-483

Enclosure:

Revised safety review schedule cc w/encl: Listserv

ML14232A332

  • concurred via telephone OFFICE LA:RPB1:DLR PM: RPB1:DLR PM:RPB2:DLR BC:RPB2:DLR PM:RPB1:DLR D:DLR NAME *YEdmonds JDaily TTran BWittick YDiaz-Sanabria JLubinski DATE 8/28/2014 8/28/14 8/28/14 8/28/14 9/2/14 9/3/14

Letter to F. Diya from J. Lubinski dated September 3, 2014

SUBJECT:

SCHEDULE REVISION FOR THE SAFETY REVIEW OF THE CALLAWAY PLANT, UNIT 1, LICENSE RENEWAL APPLICATION (TAC NO. ME7708)

DISTRIBUTION:

E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrPMCallaway Resource JDaily TTran CFLyon YDiaz-Sanabria BMizuno (OGC)

GPick, RIV

ENCLOSURE CALLAWAY PLANT, UNIT 1 LICENSE RENEWAL APPLICATION UPDATED REVIEW SCHEDULE Milestone Scheduled Actual Receive license renewal application (LRA) 12/19/11 12/19/11 Publish Federal Register Notice (FRN) - LRA availability 01/2012 01/03/12 Publish FRN - acceptance/rejection and opportunity for hearing 02/2012 02/14/12 Publish FRN - environmental scoping meeting 02/2012 02/24/12 Public Meeting - License Renewal Overview and Environmental Scoping meeting 03/14/12 03/14/12 Audit - Scoping & Screening Methodology 04/16/12 04/16/12 Audit - Aging Management Programs 04/30/12 04/30/12 Deadline for filing hearing requests and petitions for intervention 04/2012 04/24/12 Environmental scoping period ends 04/2012 04/24/12 Audit - Environmental 05/22/12 05/22/12 Inspection - Regional 09/2012 09/2012 Issue safety evaluation report (SER) with open items 04/2013 04/23/13 Issue draft supplemental environmental impact statement (SEIS) 02/2014 02/12/14 Publish FRN - draft SEIS available for comments 02/2014 02/21/14 Advisory Committee on Reactor Safeguards (ACRS) subcommittee meeting 05/2014 05/22/14 Public Meeting - draft SEIS meeting 03/2014 03/19/14 End of draft SEIS comment period 04/2014 04/07/14 Issue final SER 09/2014 ACRS full committee meeting 10/2014 Issue final SEIS 11/2014 U.S. Environmental Protection Agency FRN Published - availability of final SEIS 11/2014 Decision - Director, Office of Nuclear Reactor Regulation 12/2014