UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555*0001 May31,2012 Mr. Barry S. Allen, Vice President Davis-Besse Nuclear Power Station FirstEnergy Nuclear Operating Company 5501 North State Route 2 Oak Harbor, OH 43449

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION RELATED TO PRESSURE-TEMPERATURE LIMITS (TAC NO. ME4640)

Dear Mr. Allen:

By letter dated August 27,2010, FirstEnergy Nuclear Operating Company submitted an application pursuant to Title 10 of the Code of Federal Regulations, Part 54 for renewal of Operating License NPF-3 for the Davis-Besse Nuclear Power Station. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants." During its review, the staff has identified areas where additional information is needed to complete the review. The staff's requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.

Items in the enclosure were discussed with Steven Dort, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-2277 or bye-mail at brian.harris2@nrc.gov.

Sincerely, 7F~/

~.J?

Br~Harris, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-346

Enclosure:

As stated cc w/encl: Listserv

DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION RELATED TO PRESSURE-TEMPERATURE LIMITS

Background:

The Davis-Besse License Renewal Application (LRA), Section 4.2.4 describes the time-limited aging analysis for the P-T limit curves at Davis-Besse. As stated in LRA Section 4.2.4, the Davis-Besse P-T limit curves are established in a P-T Limits Report (PTLR), the contents of which are controlled in accordance with Technical Specification (TS) 5.6.4 requirements. The current Davis-Besse PTLR contains P-T limit curves that are valid through 32 effective full power years of facility operation. LRA Section 4.2.4 states that the P-T limit curves, as established in the PTLR, will be updated as necessary in accordance with TS 5.6.4 requirements and managed for the period of extended operation, as part of the Reactor Vessel Surveillance Program (LRA Appendix B, Section B.2.35), in accordance with the requirements of 10 CFR 54.21 (c)(1){iii).

Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix G, "Fracture Toughness Requirements," states, "this appendix specifies fracture toughness requirements for ferritic materials ofpressure-retaining components of the reactor coolant pressure boundary (RCPB) of light water nuclear power reactors to provide adequate margins of safety... " In addition, 10 CFR Part 50, Appendix G, Paragraph IV.A states that, "the pressure-retaining components of the RCPB that are made of ferritic materials must meet the requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),

supplemented by the additional requirements set forth in ["paragraph IV.A.2, "Pressure Temperature (P-T) Limits and Minimum Temperature Requirements"]... " Therefore, 10 CFR Part 50, Appendix G requires that P-T limits be developed for the entire RCPB, consisting of ferritic RCPB materials in the reactor vessel (RV) beltline (neutron fluence 2: 1 x 1017 n/cm 2, E

> 1 MeV), as well as ferritic RCPB materials not in the RV beltline (neutron f1uence < 1 x 1017 n/cm2, E > 1 MeV).

Issue:

P-T limit calculations for ferritic RCPB components that are not RV beltline shell materials, may define curves that are more limiting than those calculated for the RV beltline shell materials.

This may be due to the following factors:

1.

Some ferritic RCPB components that are not RV beltline shell materials, such as nozzles, penetrations, and other discontinuities, are complex geometry components that exhibit significantly higher stresses than those for the RV beltline region. These higher stresses can potentially result in more restrictive P-T limits, even if the reference temperature (RT NDT) for these components is not as high as that of RV beltline materials that have simpler geometries.

- 2

2.

Ferritic RCPS components that are not RV beltline shell materials may have material properties, in particular initial RT NDT values, which may define more restrictive P-T limits than those for the RV beltline shell materials.

Request:

Describe how the P-T limit curves to be developed for use in the period of extended operation, and the methodology used to develop these curves, considered all ferritic RCPS materials, consistent with the requirements of 10 CFR Part 50, Appendix G.

,: ML12144A038 I OFFICE LR/RPB1 PM:DLR/RPB1 BC:DLR/RPB1 PM:DLR/RPB1 BHarris DMorey BHarris NAME YEdmonds DATE 05/30/12 05/31/12 05/30/12

~"_=-~-c-=.r=-",:=="'~..o."'.",".~

Letter to Barry S. Allen from Brian K. Harris dated May 31, 2012

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION RELATED TO PRESSURE TEMPERATURE LIMITS (TAC NO. I\\IIE4640)

DISTRIBUTION:

HARD COPY:

DLR RtF E-MAIL:

PUBLIC RidsNrrDlrResource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDIrRer1 Resource RidsNrrDIrRer2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource P. Cooper B. Harris (OGC)

M. Mahoney