AECM-84-0464, Interim Part 21 & Deficiency Rept Re Potential Defect in Spare Piston Skirt Casings.Util Awaiting Outcome from Tdi. Reportability Still Indeterminate for Unit 2.Updated Rept Will Be Submitted by 850126.Part 21 Applicable to Unit 1

From kanterella
Jump to navigation Jump to search

Interim Part 21 & Deficiency Rept Re Potential Defect in Spare Piston Skirt Casings.Util Awaiting Outcome from Tdi. Reportability Still Indeterminate for Unit 2.Updated Rept Will Be Submitted by 850126.Part 21 Applicable to Unit 1
ML20093L491
Person / Time
Site: Grand Gulf  Entergy icon.png
Issue date: 10/05/1984
From: Dale L
MISSISSIPPI POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-84-505-000 AECM-84-0464, AECM-84-464, PT21-84-505, PT21-84-505-000, TAC-52411, NUDOCS 8410190024
Download: ML20093L491 (1)


Text

MISSISSIPPI POWER & LIGHT COMPANY Helping Build Mississippi M P. O. B O X 164 0, J A C K S O N, MIS SIS SIP PI 3 9 2 0 5 oer5,$9b7 NUCLEAR LICENSING & 1AFETY DEPARTMENT U.S. Nuclear Regulatory Commission Region II 101 Marietta St. , N.W. , Suite 2900 Atlanta, Georgia 30323 Attention: Mr. J. P. O'Reilly, Regional Administrator

Dear Mr. O'Reilly:

SUBJECT:

Grand Gulf Nuclear Station Unit 1 and Unit 2 Docket No. 50-416 and 50-417 License No. NPF-13 File: 0260/L-835.0 PRD-84/06, Interim Report for Unit 2, Potential Defect in Spare Piston Skirt Casings AECM-84/0464 Per the referenced letter, Mississippi Power & Light Company (MP&L) provided a 10CFR21 Report for Grand Gulf Nuclear Station (GGNS) Unit 1 and reported that reportability for Unit 2 was indeterminate at the time. The deficiency concerned improper heat treatment for certain spare TDI piston skirt casings. This letter prcvides a status update for the Unit 2 evaluation for reportability of this item under 10CFR50.55(e).

MP&L is currently awaiting outcome from the Transamerica Delaval, Inc.

(TDI) Diesel Generator Owners Group concerning this problem and other problems related to TDI Diesel Generators. Reportability for GGNS Unit 2 is still indeterminate. MP&L expects to submit an update for Unit 2 by January 26, 1985.

Yours truly, p L. F. Dale

. Director EBS/SHH:rg cc: Mr. J. B. Richard

,f' Mr. R. B. McGehee ,

Mr. N. S. Reynolds l Mr. G. B. Taylor l Mr. Richard C. DeYoung, Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 OFHCIAL M 'Y

\ b 6 Wember Middle South Utilities System 8410lf0g4 PDR A O 0