i Ent; y per: tic ns, inc.

eg-Port Gesurt MS 39150 Tel 601437 2129 Bill Erton G se, Manager. P' ant oreatos Gra. Ju! Nxfear staten December 11, 1997 U.S. Muclear Regulatory Commission Mail Station P1 137 Washington, D.C. 20555 Attention:

Document Control Desk

SUBJECT:

Grand Gulf Nuclear Station Unit 1 Docket No. 50-416 License No. NPF-29 Monthly Operating Report GNRO 97/00119 Gentlemen:

In accordance with the requirement of Technical Specifiution 5.6.4, Entergy Operations is providing the Monthly Operating Report for Grand Gulf Nuclear Station Unit 1 for November 1997.

If you have any questions or require additionalinformation, please contact this office.

Yours truly, f

f [

(

WAE/Sbch

/

  1. T7, /T f attachments: 1.

~ Opert(ing Status i.

2.

Average Daily Power Level 3.

Unit Shutdown and Power Reductions cc:

(See Next Page) 9712220356 971130 PDR ADOCK 05000416 R

PDR 2"'U l'H 1 'll ll 4

3 3 0

  • December 11, 1997.

1 GNRO-97/00119 Page 2 of 3 cc:

Mr. D. C. Hintz (w/a)

Mr. N. S. Reynolds (w/a)

Mr. Jager Smith (w/a)

Mr. H. L. Thomas (w/o)

Ms. K. D. Weaver (wla)

Mr. Ellis W. Mershoff (wla)

Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive Suite 400 Arlington, TX 76011 Mr. Jack Donohew, Project Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 13H3 Washington, D.C. 20555 h

l 2___-_-__________________

o j

Attachment i to GNRO-97/00119 DOCKET NO 50-416 DATE 12/04/97 COMPLETED BY S.D.Un TELEPHONE.

(601) 437-qZ9.1 OPERATING STATUS 1.

Unit Name: _GGNS UNIT 1 2.

Reporting Period: November 1997 3.

Licensed Thermal Power (MWt): 3833 MWT 4.

Nameplate Rating (Gross MWe): 1372.5 MWE 5.

Design Electrical Rating (Net MWe): 1250 MWE 6.

Maximum Dependable Capacity (Gross MWe): _1250 MWE 7.

Maximum Dependabis Capacity (Net MWe):

1200 MWE 8.

If changes occur in Capacity Ratircs (ltems 3 through /) Since Last Report. Give Reason:

N/A 9.

Power Level To Which Restric*ed, if Any (Net MWe):

Ne

.10. Reasons Fct Restrictions, if Any:

N/A This Month Yr to Date Cumulative

11. Hours in Reporting Period 720 8.016

_j i4.976

12. Number of Hours Reactor was Critical 720.0 8.016.0 95.995.0
13. Reactor Reserve Shutdown Mours 0

0 0

14. Hours Generator On-Line 720.0 8.016.0

_ _92.892.9

15. Ucit Reserve Shutdown Hours 0

0 0

13. Gross Thermal Energy Generated (MWH) 2.744.721 30.525.208 333.644.244
17. Gross Electrical Energy Generated (MWH) 934.888 10.305.229 107.577.160
18. Net Electrical Energy Generated (MWH) 925.513 9,912.392 103.136.737
19. Unit Service Factor 100.0 100 0 82.5
20. Unit Availability Factor 100.0 100.0 82.5
21. Unit Capacity Fcctor (Using MDC Net) 104.1 103.1 81.2
22. Ur.it Capacity Factor (Using DER Net) 1001 98.9 74.5
23. Unit Forced Outage Rate 0.0 0.0 5.7
24. Shutdowns Scheduled Over Next c Months (Type, Date, and Duration of Each):

Refuelino Outaae #9 bealnnino on 04/11/96 @0000 hour for 32 Days

25. If Shut Down At End of Report Period. Estimated Date of Startup:

N/A

26. tinits in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY 08/18/82 INITIAL ELECTRICITY 10/20/84 COMMERCIAL OPERATION 07/01/85

-1 <s

, to GNRD-97/00119 DOCKET NO 50-416 DATE 12/04/97' COMPLETED BY S. D. Lin TELEPHONE (601) 437-6793 MONTH November 1997 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL-(MWe-Net)-

(MWe-Net) 1 1074 17 1269 I2-1248 18 1265 3'-

-1258 19 1262 4

1259 20 1253 5

1256 24 1243 6

1260 22 1257 7

1263 23 1261 8

1263 24 1259 9

1265 25 126) 10 1260

.26 1246 11 1259-27 1243 12 1258 28 1241 13 1259 29 1211

14 1263 30 1256

-15 1245 31 N/A 16

-1269 t

4 4

.' Anne 3 to'GNRO-N0119 UNIT SHUIDOWNS AND POWER REDUCI' IONS DOCKET NO.'

50-416*

UNIT NAME

. GGNS Uni (I-

-DATE 12/0467 COMPLETED BY S. D. Lin

_ ~

TELEPHONE:

(601)437 4793-REPORT MONTH November 1997 No.

Date Type (1)

Duration Reason Method Of Licensee Event System Code Cumps Cause & Corrective Acten To Pa Hours

.(2)

Shutting Down Report #

(4)

Code (5)

Decurrence (C&CA).

Reactor (3)

None 8

1 2

3

-4

.5 F: Forced i Reason:

Me: bod:

Exhibit G - Imu AGucs for Preparati<,n of Exhibit 1 - Same Source S: Scheduled.

' A-Equipment Failure (Explain) 1-Manual Data Emry Sheets for Licensee Event B-Maintenance or Test 2-Manual Scram Report (LER) File (NUREG4161)

C-Refueling

' 3-Automatic Scram D-Regulatory Restriction 4-Continued

'. E-Operator Training &

5-Reduced load Licensing Examination 6-Other F-Admmistrative G-Operational Error (Explain)

H-Other (Explain) -

. = _ =