M.

C NTRACTORS ENGINEERS DEVELOPERS MORRISON-KNUDSEN COMPANY, INC.

==_

KT2ML9f"U%
"

PSD-HRC-86-002-R1 May 27, 1986 Mr. James Taylor U.S. Nuclear Regulatory Comission 1717 "H" Street Washington, D.C. 20555

Reference:

M-K letter PSD-NRC-86-002

Dear Mr. Taylor,

Attached please find additional information concerning a potential 10CFR Part 21 condition that was transmitted to your office on April 21, 1986, by our letter PSD-f4RC-86-002.

We will be forwarding further information as it becomes availabic. You may contact me at 208/386-6750 if you desire any further information concerning this subject.

Very truly yours, MORRISON-KNUDSEN COMPAllY, INC.

[.36&t R. D. Kulchak Corporate Q. A. Manager Construction Division RDK:bb Enc.

cc:

H. Falter (Rocky Mount w/o attachment)

F. Jones (Rocky Mount w/o attachment)

File 0606020209 060527 PDR ADOCK 00000269 PDR g

cg l

7:q

MDE-0-1016 MORRISON-KNUDSEN COMPANY, INC.

~

INTER OFFICE CORRESPONDENCE f

c,,

9 May 19, 198 oaro o 6 t

Harry W. Falter ep i to:

Ron Kulchak rao+

& hg d LOC A? TON:

C-2726 M-K Boise (Quality Department)

LocanoN EMD Memorandum File 011-0; Subject 011 T,

c' sunner.

M-K/PSD 10CFR21-0031, Revision 1 Ref:

M-DE-0-0996 dated April 21, 1986 Attached is the above revision to Notice CFR-0031-N for transmittal to the NRC. Please confirm via telex that this revision will be sent to the NRC.

hs ( J'

^

^

Harry W. Falter HWF;jb Attachment cc: Ken Lewis Vann Mitchell Note:

This revision has been mailed to all nuclear customers as well as Arkansas Power & Light Company Staaet

MORRISON-KN' DSEN COMPANY,INC.

U

=

l l

l NOTICE CRF-C031-N Revision 1. May 19, 1986 Page 1 of 2 l

l l

SUBJECT:

Material Defect - 10CFR21 Mfg. Electro-Motive Division l

General Motors l

EMD File 011-0 l

Subject 011 1.

Power Systems Division received the attached EMD file

(

011-0 notification on April 17, 1986.

2.

Determination of Reportability:

l (a) Where the dowels were misplaced to the extent I

assembly was not possible, the defect is obvious and th,e connecting rod bearing coulo not be used.

l R1 (b) Where the dowel displacement was not offset suffi-ciently to prevent assembly, the defect would not be obvious. A review of the reported defect revealed l

that the offset due to the dowel hole location is axial and not radial.

If the bearing shell fits into the connecting rod without forcing it into place, the offset will not impact the proper func-tion of the bearings providing the bearing does not contact the radius of the web of the crankshaft.

I P'or suspect con rod bearing that may be installed into engines, a visual inspection of the crankcase shall be performed.

This is to assure that the upper con rod bearing is in the center of its thfow with clearance on either side and not mislocated axially (fore and aft) such that the bearing shell might contact the radius or web of the crankcase.

Standard visual inspection procedures such as look-ing for signs of overheat and bearing distress i

should be followed.

I (c)

EMD advises that only six out of 900 bearings of the lot were found defective to date.

3.

Resolution:

(a) All connecting rod bearings purchased between November 1985 and the end of April 1986 are suspect and shall be inspected dimensionally in accordance with the EMD attachment.

l l

MORRISON-KNUDSEN COMPANY, INC.

om NOTICE CFR-0031-N Revision 1, May 19, 1986 Page 2 of 2 (b)

EMD are inspecting all subject bearings in stock and anticipate completion of inspections by the end of April 1986.

(c) Advise all owners of EMD engines to whom PSD fur-nished engines or parts of this defect.

l'~. i b-ldl SEAL dn ~V U

i.

M33 '

/ j sa ry w. Faiter, e.e.

7033

,,....L hi.,

uc: Mr. aTiw 10CFR21 File E. Martin V. Mitchell MORRISO manmn=o N-KNUDSEN COMPANY, INC.

Ron Kulchak

.o May 20, 1986 General Electric Company 175 Curtner Avenue San Jose, California 95125 Attention:

Mr. R.F. Pariant, M/C 523

Subject:

P.O. 205AD586/ Laguna Verde P.O. 205A0585/ Grand Gulf MK/PSD IWO No. 336 MK/PSD IWO No. 377 P.O. No. 205AD587/Kuo Sheng P.O. No. 205AD589/Cofrentes MK/PSD IWO No. 406 MK/PSD IWO No. 456 P.O. 205A0583/Hanford II P.O. 205AG891/CN" MK/PSD IWO No. 990 MK/PSD IWO No. 856

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:Jb Attachment

m cc:

H. Falter 10CFR21 File

' MORRISON-KNUDSEN COMPANY, INC.

E. Martin

" asv57m om e V. Mitchell Ron Kulchak May 20, 1986 General Electric Company 175 Curtner Avenue San Jose, CA 95125 Attention:

Mr. R.F. Pariani M/C 523

Subject:

G.E. for L.V.

PSD IWO 2058 - Customer No. 20586F293, Item No. 29 Quantity 1 - P/N 8354118 - Upper Connecting Rod Bearing Shipped 3/31/86

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

1 1

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWE.' SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment

cc:

H. Falter 10CFR21 File

  • MORRISON-KNUDSEN COMPANY, INC.

k $$ti powen systense omssom E

May 20, 1986 Portland General Electric 121 Southwest Salmon Street Portland, OR 97204 Attention:

Mr. R. L. Steele, Manager Nuclear Plant Engineering Department - Nuclear Division

Subject:

Trojan Nuclear Plant - P.O. No. N00272 Bechtel Job No. 6478 - Specificatton No. 6478M16 M-K/PSD IWO No. 071

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

1 Yours very truly, l

MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION 86Ao Ed Martin Contracts Administrator EM:Jb Attachment

cc:

H. Falter 10CFR21 File MORRISON-KNUDSEN COMPANY, INC E. Martin

" "8" * "*'c" V. Mitchell Ron Kulchak May 20, 1986 Ebasco Services, Inc.

Eleven Eleven S. Federal Highway Stuart, FL 33494 Attention:

Mr. Tcm Malone Procurement Supervisor

Subject:

Florida Power & Light Company St. Lucie Project P.O. No. NY422553 M-K/PSD IWO No. 6002

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment g

e

cc:

H. Falter 10CFR21 File MORRISON-KNUDSEN COMPANY, INC.

E. Martin eowea svanus omem V. Mitchell Ron Kulchak May 20, 1986 Union Electrica, S.A.

Capitan Haya, 53 Madrid - 20, Spain Attention:

Sr. Jorge Martin

Subject:

Zorita Nuclear Plant Diesel Generator System U.E. Order No. 750.008 IPS IWO No. 6049

Reference:

Xotice CFR'-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

)

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUCSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:Jb Attacnment

F

' MORRISON<KNUDSEN CdMPANV, INC.

'r n

" " " " ~

V. Mitchell 7

Ron Kulchak

,a

'May 20, 1986 e

Mill Power Supp'ly Company P.O. Box 32307 Charlotte, Nortn. Carolina 28232 Attention:

Mr. W. L. M::Pharson Subject.:

Oconee Nuclear Stations, Units 1, 2 and 3 Diesel G3nerator ' Sets Mill Power 50pply P.O. E 50338 74 M-K/PSD IWO No. 6022

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electronttive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFP21 notice that relates to a I

material defect.

4 This replaces Notica CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly.

MORRISON4KNUDSEN COMPANY, INC.

PGWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment

a 2

' MORRISON-KNUDSEN COMPANY,INC.

  • * " " " " ~

n V. Mitchell Ron Kulchak m

=g2.

May 20, 1986

'Astinghouse Electric Corporation Parkway Center - Building No. 5 875 Greentree Road P1ttsburgh, PA 15220 Attention:

Mr. Steve Pavick Suoject:

Diesel Generator Sets KRSKO-P.O. 13KRA168JC MK/PSD IWO NO. 6003 Karl II - P.O. 13TDAG1k1 MK/PSD IW0'NO. 6024 Philippines Project - P.O.13PLA325WC MK/PSD IWO NO. 6019

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment

',Mb..RR.!SO,.N, KNUDSEN COMPANY, INC,

~ ^

C ile o.

1m o

.o.

E. Martin Ty'{g*jg"

,a Ron ch TELD 802507 PSO-AYWO May 20, 1986 General Electric Company International Sales Division One River Road Schenectady, NY 12345 Attention:

Mr. Walt CeMichiel

Subject:

Hidroelectrica Cofrentes P.O. No. 247P11814696720 Hidrola Order No. X6459/3 MK/PSD IWO No. 6001

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors

'EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:Jb Attachment

+eM l

cc:

H. Falter ON 10CFR21 File

' MORRISmmo.KNUDSEN COMPANY, INC.

men innu E. Martin k.h gygme Ron u ch May 20, 1986 Power Authority of the State of New York James A. Fitzpatrick Nuclear Power Plant P.O. Box 41 Lycoming, NY 13093 Attention:

Mr. Joe Troia Subject :

Pasny Contract No. AP940 J.A. Fitzpatrick Diesel Generators J.0. No.11825 - MK/PSD IWO NO. 940

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator i

EM:jb Attachment

' MORRISON-KNUDSEN COMPANY, INC.

7bC IFile powen sysnus omsos

[ ESE R$n c

May 20, 1986 Sacramento Municipal Utility District - Rancho Seco 1444 Twin Cities Road Herald, CA 95638-9799

' Attention:

Mr. George Coward Plant Superintendent Subject :

Sacramento Municipal Utility District Rancho Seco Units I and II Contract No. 3463 (M17.1)

Bechtel Joti N0. 6292 MK/PSD IWO NO. 903

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 16CFR21 notice that relates to a material defect.

This replaces Notice CFR4031-N transmitted to ybu on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION 1

M Ed Martin Contracts Administrator EM:jb Attachment

cc:

H. Falter MORRISON-KNUDSEN COMPANY, INC.

10CFR21 File m = asu n = = sica E. Martin 7

gal;" = 'm Ron c

May 20, 1986 Central Nuclear de Almaraz Princesa 3, 4a Planta 28008 Madrid, Spain Attention:

Opto. Garantia de Calidad

Subject:

C.N. Almaraz P.O. 011M2201 MX/PSD IWO No. 38S

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment

cc:

H. Falter 10CFR21 File

' MORRISO.N-KNUDSEN COMPANY, INC.

E. Martin mwen unna om.o V. Mitchell msr emes sex,.

Ron KuIchak aggu,rygg_vemim rnex mw wmo May 20, 1986 Ebasco Services, Inc.

Two World Trade Center New York, NY 10006 Attention:

Cesar Rui z

Subject:

Laguna Verde Project Order No. LV/13049 IPS IWO No. 6020

Reference:

Notice CFR*0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 23, 1986.

Yours very truly, MORRISON-KNtJDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment

' MO.RRISO.N-KNUDSEN COMPANY, INC.

cc:

H. Falter no mnm om.o 10CFR21 File post cues sex im E. Martin gge_mgouy4=ge V. Mitchell r a,x o

Ron Kulchak May 20, 1986 Ebasco Services, Inc.

Two World Trade Center New York, NY 10006 Attention:

Joe Perrone Project Manager Subject :

Taiwan Power Company, Chin Chan Units 1 and 2 Emergency Diesel Generators Contract No. NY906279 MK/PSD IWO.No.115

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMDf.NY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:Jb Attachment

cc:

H. Falter 10CFR21 File MORRISON-KNUDSEN COMPANY, INC.

E. Martin mwen sveron om*ca V. Mitchell Ron Kulchak May 20, 1986 General Electric Company Knolls Atomic Power Laboratory P.O. Box 1072 Schenectady, NY 12301-1072 Attention:

Mr. R. J. Matteo Subject :

Diesel Generator Rehab Project Diesel Generator Rehab Project P.O. No. NPD 83K2302CM P.O. No. NPC83W1622CD MK/PSD IWO No. 6062 MK/PSD IWO No. 6059 Reference :

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:Jb Attachment

cc:

H. Falter 10CFR21 File MORRISON-KNUDSEN COMPANY, INC.

E. Martin mwen sysrums oms o,.

V. Mitche11 Ron Kulchak May 20, 1986 Universal Trading Company P.O. Box 4399 Abu Dhabi, U.A.E.

Attention:

SAHA

Subject:

Universal Trading Company for ABu Dhabi Customer Order L/C 1036/85 Item A-2#1, P/N 8354118 - Upper Connecting Rod Bearing Quantity 50 - Shipped 2/19/86

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment

10CFR21 File E. Martin V. Mitchell MORRISON-KNUDSEN COMPANY, INC.

Ron Kulchak Powest SYSTttes OnneON EX 80250 May 20, 1986 Rosario Resources Corporation AMAX Center Greenwich, CT 06836 Attention:

Sonia Germosen - Genao (Buyer)

Subject:

Rosario Resources Corporation for Honduras P. 0. A25188, Item 1 PSD IWO No. 2098 Quantity of 5 - P/N 83S4118, Upper Connecting Rod Bearing Shipped 4/10/86

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to yo'u on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:Jb Attachment

E 10CFR21 File E. Martin V. Mitchell

. MORRISON-KNUDSEN COMPANY, INC.

Ron Kulchak Powen sysitass osvissoas r

POST CFFICE SCX $928 TWX o

T[5 rna.onor 77soa m May 20, 1986 The Toledo Edison Company P.O. Box 929 Toledo, OH 43652 i

Attention:

Mr. John K. Wood General Supervisor, Facility Engineering

Subject:

Toledo Edison Company - Davis Besse Nuclear Station Unit No.1 - Bechtel Job No. 7749 Emergency Diesel Generators - Specification No. 7749M170 TECO P.O. No. Q1542 - M-K PSD IWO No.157

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 l

Material Defect - 10CFR21 l

Mfg. Electro-Motive Division l

General Motors EMD File 011-0 l

Subject 011 j

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

t l

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb l

l Attachment t

/

10CFR21 File E. Martin

'MORRISON-KNUDSEN COMPANY, INC.

R$n uIc Powen Sysfgest OlvtWON Ox77E%"

May 20, 1986 Arkansas Power and Light Company P.O. Box 608 Russellville, Arkansas 72801 Attention:

Mr. Wesley McDaniel Buyer, Nuclear

Subject:

PSD IWO No. 2072 Arkansas Power & Light P.O. 47105, Item 6 Quantity 20, P/N 8354118, Upper Connecting Rod Bearing' Shipped 3/11/86

Reference:

Notice CFR-0031-N, Revision 1 dated May 19, 1986 Material Defect - 10CFR21 Mfg. Electro-Motive Division General Motors EMD File 011-0 Subject 011

Dear Sir:

Attached is revision 1 to the above 10CFR21 notice that relates to a material defect.

This replaces Notice CFR-0031-N transmitted to you on April 28, 1986.

Yours very truly, MORRISON-KNUDSEN COMPANY, INC.

POWER SYSTEMS DIVISION Ed Martin Contracts Administrator EM:jb Attachment cc:

Ms. Margaret Snow, P.O. Box 551, Little Rock Arkansas 72203