05000348/LER-1985-005, Forwards Results of Testing/Insp of 11 Tendon Anchor Heads, Based on Commitment in 850812 LER 85-005-01 to Conduct Addl Tests & Insps on Tendon Anchor Heads Which Failed Due to Hydrogen Stress Cracking.Anchor Heads Acceptable

From kanterella
Jump to navigation Jump to search
Forwards Results of Testing/Insp of 11 Tendon Anchor Heads, Based on Commitment in 850812 LER 85-005-01 to Conduct Addl Tests & Insps on Tendon Anchor Heads Which Failed Due to Hydrogen Stress Cracking.Anchor Heads Acceptable
ML20137M010
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 01/17/1986
From: Mcdonald R
ALABAMA POWER CO.
To: Rubenstein L
Office of Nuclear Reactor Regulation
Shared Package
ML20137M015 List:
References
NUDOCS 8601280167
Download: ML20137M010 (4)


LER-2085-005, Forwards Results of Testing/Insp of 11 Tendon Anchor Heads, Based on Commitment in 850812 LER 85-005-01 to Conduct Addl Tests & Insps on Tendon Anchor Heads Which Failed Due to Hydrogen Stress Cracking.Anchor Heads Acceptable
Event date:
Report date:
3482085005R00 - NRC Website

text

r Mailing Ad# mss ,

Atabama Pcwer Company 6D3 North 18th Street Post Omce Boi 264t G.rm ngham Atacama 35291 Tele pMne 205 783-6000 R. P. Mcdonald Seneer Vcc Pres dent ner.= e e g \lahamal\)WCf January 17, 1986 Docket Nos. 50-348 50-364 Director, Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Mr. L. S. Rubenstein Joseph M. Farley Nuclear Plant - Units 1 and 2 Containment Tendon Anchorhead Report Gentlemen:

By letter of July 10, 1985, Alabama Power Company provided the NRC with the results of the inryco investigation of the Containment Tendon Anchorhead failures at the Farley Nuclear Plant. This investigation concluded that the tendon anchorheads failed as a result of hydrogen stress cracking. On August 12, 1985 voluntary LER 85-005-01 was submitted to the NRC. This LER concludod that containment structural integrity had been maintained continuo- ly for both units and that additional tests and inspections would be conducted.

Enclosed (two letters, one report) are the results of the testing /

inspection of eleven additional tendon anchorheads. These eleven anchorheads consisted of one anchorhead from each of the heat types currently in use at the Farley fuclear Plant and one heat type from the replacement group of anchorheads. Inryco has found that the strengths and hardnesses of these eleven anchorheads are acceptable. These results are being voluntarily provided for NRC information purposes.

If you have any questions, please advise.

Ve ry t rul 'you r's ,

/1/

0601280167 060117 PDR ADOCK 05000340 --)

h(b)bri '

O PDR ('

R. P. Mcdonald RPM / JAR:ddb-038 jgf Enclosures L o t, cc: See Page 2 l

- - . _ _ ~ _ .- . _ - .

  • c Mr. L. S. Rubenstein January 17, 1986 U. S. Nuclear Regulatory Commission Page 2 cc: Mr. L. B. Long Dr. J. N. Grace Mr. E. A. Reeves fir. W. H. Bradford i.

i 1

I i

i l

~

Conerste Systems Devis.on _

  • 7200 S. Nzertgtnsstt Avsnus . '1 i -.
  • Bsdford Park

. Checago, Hhnois 60638 6087 i 312 585 7300 Chicago

, 312 594 7300 Suburban TLX 721497 BOPA FAX Eat 202 ,

I .!

} h Inryco October 31, 1985 '

1  ;

1 1 i

1 #

Alabama Power Company '

P.O. Box 2641 Birmingham, AL 35219 l

Attention: Mr. D. E. Mansfield i

i 4

SUBJECT:

, Farley Nuclear Plant - Units 1 & 2 -*

i 3 APCO P.O. #40578 ,

F Anchorhead Testing /Innpection

References:

Inryco letter dated 8/29/85 Hendrickson to Hansfield.

a Telecon dated 10/29/85 between Heise and Mansfield.

k, De- Mr. Hansfield:

1 l As equested, inryco has reviewed Inland Steel Company's Operating I Technology Department Laboratory Investigation No. 20617 for the l

eleven anchorheads tested / inspected.

l The hardnesses and strengths of the eleven anchorheads are found to i

be acceptable to meet the intended purpose of the original constru-

{ ction specifications for anchorheads to maintain the stress of a

) tendon. ,

j Very truly yours, '

i

\

I j k.$ 'N w Harry T. Hendrickson pi 84 Project Manager h 4 3

i HTH Igw I N $

cc: J. Heise

! D. Waitkus I ,

l

. . . .,, /

l i

I; -

(

i

en inland steet company

IN;.YCO, Inc .

Cincret Syst:ms Dmsi:n .

7200 S Narragansett Avenue Beaford P;rk Chicago Ilhnois 60638-6087 .

312 585 7300 Chicago 312 594 7300 Suburban TLX 72-1497 BDPK FAX Eit 202 h inryco August 29, 1985 Alabama Power Company 6200 Flintridge Road U.S. Steel Building Fairfield, Alabama 35219 Attention: Mr. Don Mansfield i SUEJECT: Farley Nuclear Plant - Units 1 & 2 APC0 P.O. 440578

Reference:

Anchorhead Investigation

Dear Mr. Mansfield:

As required by Item 6 and 7 of the above sucject purchase order Inryco. Inc. had Inland Steel Company's Operating Technology Departeent perforra testing / inspection of eleven tendon anchor-heads forwarded to us by Alabama Power Company.

Find enclosed as per your request, four copies of Inland Steel Company's Operating Technology Department Metallurgical 1.aboratory Investigation No. 20617 for the testing / inspection performed on the eleven anchorheads.

Very truly yours, v'

liarry F. Hendrickson \p Project Manager g h hsPi liFil:mc g N N& *I hi. closure ,

88 os cc: J. lleiso .cf D. Waitkus '% Ggg en inland Steel company