N b

Alabima Pow:r CompIny -

  • l b

40 Inverness CIntit P:fkncy.

Post Ofhce Dox 1295 Dirmingham Alat,ame 35201 Telephone 205 868-5561 -

g

. W. G. Hairston, til =

+

Senior Vice President' Nuclear Operations -

AlabamaPower-g the 50uthem elecinc system August 15, 1990 10CFR50.55a(g) c

/

4 -

-Dock'et No. 50-364 U. S. Nuclear Regulaton Commission Attention:

Document Control Desk

{

Vashington, D.' C..20555 b

Gentlemen:

Joseph H. Farley Nuclear Plant - Unit 2 Updated Inservice Inspection Program for ASME Code Class 1, 2 and 3 Components o

~

Revision 0 of the Unit'2 updated Inservice Inspection (ISI) Program was submitted to the NRC by letter dated December 16, 1988.. The NRC granted interim approval of certain reliefs by-letter dated March 31, 1989.' As te 3

discussed in letters dated February 8 and March 23, 19G9, approval of the

-o l(

remaining relief' requests was deferred.- ' Alabama Power Company proposed a f

schedule for approval of the remaining reliefs by letter dated June 8, 1989.

L 3

By letter dated. August 3, 1989, the NRC requested that-Alabama Power M

Company provide additional information pertaining to the review of the ISI:

. Program. Alabama Power Company responded to the NRC's Request for Additional-

,f Information-(RAI), 'ay letters' dated October 5 and' December 7,.1989 and l

April 12, 1990.

1' 0, -.

The RAI responses contained commitments to revise.the ISI Program including the

~

L modification'or: deletion of certain relief requests. Revision 1 of'the ISI Program is herewith submitted to incorporate these changes.

9008170229 poosj3 DR ADor:K 05000364 g

voc

' Q

1 U. S. Nuclear Regulatory Commission Page 2 l

It is requested that the NRC's review of the ISI Program including this latest-revision be completed and SER issued with granting of relief requests by September 28, 1990. Granting the remaining relief requests in accordance with this proposed schedule vill provide approximately one year (not including the Code allowed one-year extension) for Alabama Pover Company to complete the required examinations.. This vill also permit proper planning of examinations to be performed during the remaining refueling outage tentatively scheduled to begin October 12, 1990.

If there are any questions or if additional information is needed, please advise.

Respectfully submitted, ALABAMA POVER COMPANY lhc V. G. Hairston, III l

VGil/DEM/ STB i cht-nre.8. 33 Enclosure cci Mr. S. D. Ebneter Mr. S. T. Hoffman I

Mr. G. F. Maxwell Mr. B. Brown f

L L