ML20059J281

From kanterella
Jump to navigation Jump to search
Forwards List of Key Radiation Monitors Which Will Be Used as Inputs to Top Level Radioactivity Status Bar Re Spds.List Identifies Monitors Which Would Provide Concise & Meaningful Info About Radioactivity During Accidents
ML20059J281
Person / Time
Site: Farley  
Issue date: 09/14/1990
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9009190250
Download: ML20059J281 (3)


Text

g.

4..

Q I

  • 1 40 inverness Center Parkway <

Post Offee Box 1295 -

Birmingham, Alabama 3S201 Telephone 205 868 5581; W. G. Heireton, lil '

C Sontor Vice P.esident September 14,1990 gghg g

Nclear operatkns

. the sodhem electrc system Docket Nos' 50-348

.50-364:

1' U.

S.' Nuclear Regulatory Commission-ATTNi i Document-Control Desk Vashington,'D. C. 20555 3

Gentlemen:

I

. Joseph H. Farley Nuclear Plant - Unin i tad 2--

Safety Parameter Display System-(SPOS) Radiout;vity StatusL j

-radioactivity status bar to the~SPDS top level summary display:and a. list

- I

.By letter dated June 26, 1990, Alabama Power Company committed to add'a

~

of radiation monitor readings as a second level display.,_ By letter _ dated Aucust 10, 1990, the NRC-requested specific ~information about the inputs to each of these displays.. Provided'as Attachment 1.ja a list of key-radiation monitors which will be,used as' inputs totthe top level radioactivity status bar. This list attempts.to._ identify _.those monitors

-i which would-provide concisetand meaningful >information about radioactivity-L in areas of interest during an accident.- Provided as Attachment-2 is a complete list of radiation monitors which vill be~ inputs tosthe second level display.

i As previously stated, Alabama Power. Company will implement'the changes to the.SPDS as_ described above by,the end of:the second refueling outage' i

following receipt cf NRC approval _of the proposed resolution.

If there are any questions, please advise.

l l\\

-i Respectfully submitted,-

i

/Y it).b'). );br -,

- 'b

-i L

r V. G. Hairston, III VGE,111/BHV:-e3 23.23 Attachme,a cc: Mr.'S. D. Ebneter Mr.

S..T. Hoffman Mr. G. F. Maxwell hf Qhb l

l l 1

q, m q.

.3.

e

, (-

o 4:,..;

s Attachment l'

. Inputs To The Radioactivity Status Bar'(Top Level):

v Monitor Description 4

R-02/

Containment Area Monitor.

R-07 In-core Instrument Area'Honitor R-11.

Plant' Containment Air Particulate Monitor' R-12:

iPlant Containment, Gas Monitor

' R-14 Plant Vent Stack Gas Monitor.

R-15A.

Condenser Air Ejector Monitor-

~R-15B-Condenser Air Ejector Monitor.

R-150-

' Condenser. Air Ejector Monitor' R-21

Plant-Vent Stack; Air Particulate'Honitor-R-22 Plant Vent Stack Gas Sample Monitor'.,

1

-R-23A-Steam Generator Blowdown Processing ~Ho.iitorl

-1

.R-23B Steam Generator. Blowdown Processing Mo~1 tor-.

)

~

)

R-29B SPING-4 Vent Stack Monitor; R-60A A Steam. Generator Atmospheric Relief Exhaust Monitor.

H R-60B B Stcam Generator Atmospheric Relief Exhaust Monitor' R-60C' C Steam Generator Atmospheric Relief' Exhaust Monitor

.R-60D Auxiliary Feedvater Turbine Exhaust Monitor

-R-70.

N16 Steamline.Honitor:

9 i

U-

.]

ll BHV mgd 23.23 1

.l

i

'l

]j

]

]

}

,l a

d-~iM 4-l' r

' > ;i

,[

lL 4:...s e Attachmenti2'

Inputs to List of Radiation Monitor Readings:(Second Level)

Monitor' oescription

'R-02:

= Containment Area Monitor L'

R-03

. Radiochemistry Lab Monitor.

(

R-04 Charging Pump Room Area: Monitor-R-05.

Spent Fuel Building Area Monitor:

i R-06 Sampling Room l Area. Monitor-R-07 In-core Instrument. Area Monitor-R-08 Drumming: Station Area Monitor R-10 Penetration Room Air Particulate Monitor R-11 Plant Containment: Air Particulate Monitor-l R-12 Plant' Containment Gas Monitor j

~

~R-14 Plant' Vent Stack Gas Monitor R-15A'

.Condonmer Air Ejector' Monitor R-15B Condenser Air Ejector Monitor.

R-15C' Condenser Air Ejector Monitor R-19 Steam. Generators! Liquid Monitor R-20A

. Service Vater Liquid Monitor, R-20B Service Water' Liquid Monitor' R-21 Plant Vent' Stack AirLParticulate Monitor R-22

" Plant' Vent Stack Gas'SamplsLMonitorL R-23A Steam Generator,Blovdown ProcessingiMonitor R-23B Steam Generator Blowdown. Processing Monitor-R-24A Containment Purge Exhaust Monitor:

l R-24B Containment Purge-Exhaust Monitor R-27A

' Containment High' Range Monitor d

R-27B Containment.High Range Monitor R-29B SPING-4 Plant Vent Stack : Monitor 1

-R-35A Control' Room Ventilation IntakeLHonitor j

l~

R-35B Control Room Ventilation. Intake; Monitor-I R-60A A Steam. Generator Atmospheric' Relief ; Exhaust Monitor.

d m

R-60B B Steam; Generator Atmospheric Relief: Exhaust Monitor' R-60C C Steam Generator' Atmospheric Relief Exhaust Monitor R-60D Auxiliary.Feedvater. Turbine Exhaust Monitor R-70 N16 Steamline Monitor:

r 1

4 d

e i

BHV:mgd 23.23 0

t 6

i z..

. 4.

m...