Forwards Proprietary & non-proprietary Responses to NRC RAIs Re W TR WCAP-14750, RCS Flow Verification Using Elbow Taps at W 3-Loop Pwrs. W Proprietary Notice,Affidavit & Copyright Notice,Encl.Proprietary Info Withheld
ML20195F173
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 06/07/1999
From: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20137T089 List:
References
NEL-99-0217, NEL-99-217, NUDOCS 9906140216
Download: ML20195F173 (3)


Text

.

[.

  • D;v)Morey Southern Nuclear 1-

- Vicefiesident Operating Company,Inc.

,;~

farley Project.

Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.5131 SOUTHERN

-June 7, 1999 EnergyroServe %urWorld*

Docket Nos.:

50-348 NEL-99-0217 50-364 ~

' U. S. Nuclear Regulatory Commission A'ITN: Document Control Desk

. Washington, D. C. 20555-0001 Joseph M. Farley Nuc! car Plant Response to-Request for Additional Information Related to WCAP-14750, "RCS Flow Verification Usina Elbow Taos at Westinnhouse 3-Loon PWRs" Ladies and Gentlemen:

By letter dated November 26,19%, Southern Nuclear Operating Company (SNC) submitted a Westinghouse Owners Group (WOG) technical report, WCAP-14750, for NRC Staff review and approval. SNC letters dated October 1,1997 and February 2,1999 responded to NRC Staffrequests for additional information. He attached documents provide the SNC responses to additional questions

. resulting from telephone conferences on March 16 and May 10 and 12,1999.

The attachments also include Westinghouse authorization letter CAW-99-1337 and accompanying affidavit, proprietary information notice, and copyright notice. As "Farley Nuclear Plant (V'estinghouse Owners Group) Responses to NRC Request for Additional Information (RAI #3) Related to YICAP-14750, 'RCS Flow Verification Using Elbow Taps at Westinghouse 3-Loop PWRs'" contains i nformation proprietary to Westinghouse Electric Corporation, it is supported by an aflidavit signed by Westinghouse, the owner of the information. He affidavit sets forth the basis on which the information may be withheld from public disclosure by the Conunission and addresses tne considerations listed in paragraph (b)(4) of

' 10 CFR Section 2.790. Correspondence with respect to the copyright or proprietary aspects of the items listed above or the supporting Westinghouse affidavit should reference lettet CAW-99-1337 and should be addressed to J. S. Galembush, Acting Manager of Regulatory and Licensing Engineering, Westinghouse Electric Company, P. O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

Ecre are no new commitments in this response. If you have any questions, please advise.

Respectfully submitted,

@ 4?fw Dave Morey MGE/mafrestemp9. doc 0l Attachments I.

Westinghouse Letter CAW-99-1337 II.

FNP Responses to NRC RAI - Proprietary Class 2C III. FNP Responses to NRC RAI - Non-Proprietary Class 3

~

9906140216 990607 PDR ADOCK 05000348 -

bbl P

PDR

l Page 2 U. S.. Nuclear Regulatory Commission cc:

Southern Nuclear Operatina Company Mr. L. M. Stinson, General Manager-Farley U. S. Nuclear Regulatory Commission. Washincton. D. C.

- Mr. L. M. Padovan, Licensing Project Manager - Farley U. S. Nuclear Renulatory Commission. Renion 11 Mr. L. A. Reyes, Regional Administrator

.' Mr. T. P. Jolmson, Senior ' Resident Inspector - Farley x

ATTACHMENTI SNC Response To NRC Request For AdditionalInformation On WCAP-14750, "RCS Flow Verification Using Elbow Taps At Westinghouse 3-Loop PWRs,"

Joseph M. Farley Nuclear Plant Units 1 & 2 Westinghouse letter CAW-99-1337, dated May 24,1999, " Application For Withholding Proprietary Information From Public Disclosure," with the following enclosures: Affidavit, Proprietary Information Notice, and Copyright Notice v

1

... - _ _ _ _ _