MONTHYEARML20217M4461999-10-20020 October 1999 Forwards Rev 8 to Sequoyah Nuclear Plant Physical Security/ Contingency Plan, IAW 10CFR50.54(p).Encl Withheld,Per 10CFR73.21 05000327/LER-1999-002, Forwards LER 99-002-00 Re Start of Units 1 & 2 EDGs as Result of Cable Being Damaged During Installation of Thermo- Lag for Kaowool Upgrade Project1999-10-15015 October 1999 Forwards LER 99-002-00 Re Start of Units 1 & 2 EDGs as Result of Cable Being Damaged During Installation of Thermo- Lag for Kaowool Upgrade Project ML20217J4151999-10-15015 October 1999 Forwards Request for Addl Info Re Util 990624 Application for Amend of TSs That Would Revise TS for Weighing of Ice Condenser Ice Baskets ML20217G1141999-10-0707 October 1999 Responds to from P Salas,Providing Response to NRC Risk Determination Associated with 990630 Flooding Event at Sequoyah Facility.Meeting to Discuss Risk Determination Issues Scheduled for 991021 in Atlanta,Ga ML20217B2981999-10-0606 October 1999 Discusses Closeout of GL 92-01,rev 1,suppl 1, Reactor Vessel Integrity, for Sequoyah Nuclear Plant,Units 1 & 2. NRC Also Hereby Solicits Any Written Comments That TVA May Have on Current Rvid Data by 991101 ML20217B8431999-10-0505 October 1999 Requests NRC Review & Approval of ASME Code Relief Requests That Were Identified in Plant Second 10-yr ISI Interval for Both Units.Encl 3 Provides Util Procedure for Calculation of ASME Code Coverage for Section XI Nondestructive Exams ML20217C7101999-10-0101 October 1999 Forwards Response to NRC 990910 RAI Re Sequoyah Nuclear Plant,Units 1 & 2 URI 50-327/98-04-02 & 50-328/98-04-02 Re Ice Weight Representative Sample ML20212J5981999-10-0101 October 1999 Forwards SE Accepting Request for Relief from ASME Boiler & Pressure Vessel Code,Section Xi,Requirements for Certain Inservice Insp at Plnat,Unit 1 ML20212M1081999-09-29029 September 1999 Confirms Intent to Meet with Utils on 991025 in Atlanta,Ga to Discuss Pilot Plants,Shearon Harris & Sequoyah Any Observations & Lessons Learned & Recommendations Re Implementation of Pilot Program ML20217A9451999-09-27027 September 1999 Forwards Insp Repts 50-327/99-05 & 50-328/99-05 on 990718- 0828.One Violation Identified & Being Treated as Non-Cited Violation ML20216J9351999-09-27027 September 1999 Responds to NRC Re Violations Noted in Insp Repts 50-327/99-04 & 50-328/99-04.Corrective Actions:Risk Determination Evaluation Was Performed & Licensee Concluded That Event Is in Green Regulatory Response Band ML20212F0751999-09-23023 September 1999 Forwards SER Granting Util 981021 Request for Relief from ASME Code,Section XI Requirements from Certain Inservice Insp at Sequoyah Nuclear Power Plant,Units 1 & 2 Pursuant to 10CFR50.55a(a)(3)(ii) ML20212F4501999-09-23023 September 1999 Forwards Amends 246 & 237 to Licenses DPR-77 & DPR-79, Respectively & Ser.Amends Approve Request to Revise TSs to Allow Use of Fully Qualified & Tested Spare Inverter in Place of Any of Eight Required Inverters ML20212A1631999-09-13013 September 1999 Forwards W Rept WCAP-15224, Analysis of Capsule Y from TVA Sequoyah Unit 1 Reactor Vessel Radiation Surveillance Program, Rev 0.Errata Sheet Containing Three Correction Pages to WCAP-15224 Also Encl ML20211Q0311999-09-10010 September 1999 Requests Written Documentation from TVA to Provide Technical Assistance to Region II Re TS Compliance & Ice Condenser Maint Practices at Plant ML20216F5441999-09-0707 September 1999 Provides Results of Risk Evaluation of 990630,flooding Event at Sequoyah 1 & 2 Reactor Facilities.Event Was Documented in Insp Rept 50-327/99-04 & 50-328/99-04 & Transmitted in Ltr, ML20211N5681999-09-0101 September 1999 Submits Clarification of Two Issues Raised in Insp Repts 50-327/99-04 & 50-328/99-04,dtd 990813,which Was First Insp Rept Issued for Plant Under NRC Power Reactor Oversight Process Pilot Plant Study ML20211G5881999-08-27027 August 1999 Submits Summary of 990820 Management Meeting Re Plant Performance.List of Attendees & Matl Used in Presentation Enclosed ML20211F8891999-08-25025 August 1999 Forwards Sequoyah Nuclear Plant Unit 1 Cycle 9 Refueling Outage, Re Completed SG Activities,Per TSs 4.4.5.5.b & 4.4.5.5.c ML20211A1851999-08-16016 August 1999 Forwards Proprietary TR WCAP-15128 & non-proprietary Rept WCAP-15129 for NRC Review.Repts Are Provided in Advance of TS Change That Is Being Prepared to Support Cycle 10 Rfo. Proprietary TR Withheld,Per 10CFR2.790 ML20210V1471999-08-13013 August 1999 Forwards Insp Repts 50-327/99-04 & 50-328/99-04 on 990601- 0717.One Potentially Safety Significant Issue Identified.On 990630,inadequate Performance of Storm Drain Sys Caused Water from Heavy Rainfall to Backup & Flood Turbine Bldg ML20211A1921999-08-12012 August 1999 Requests Proprietary TR WCAP-15128, Depth-Based SG Tube Repair Criteria for Axial PWSCC at Dented TSP Intersections, Be Withheld from Public Disclosure Per 10CFR2.790 ML20210Q5011999-08-0505 August 1999 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam on 991006 at Sequoyah Nuclear Plant. Sample Registration Ltr Encl ML20210L4291999-08-0202 August 1999 Forwards Sequoyah Nuclear Plant Unit 2 Cycle 9 12-Month SG Insp Rept & SG-99-07-009, Sequoyah Unit-2 Cycle 10 Voltage-Based Repair Criteria 90-Day Rept. Repts Submitted IAW TS 4.4.5.5.b & TS 4.4.5.5.c ML20210L1611999-07-30030 July 1999 Forwards Request for Relief RV-4 Re ASME Class 1,2 & 3 Prvs, Per First ten-year Inservice Test Time Interval.Review & Approval of RV-4 Is Requested to Support Unit 1 Cycle 10 Refueling Outage,Scheduled to Start 000213 ML20210G5301999-07-28028 July 1999 Forwards Sequoyah Nuclear Plant Unit 2 ISI Summary Rept That Contains Historical Record of Repairs,Replacement & ISI & Augmented Examinations That Were Performed on ASME Code Class 1 & 2 Components from 971104-990511 ML20211B9661999-07-26026 July 1999 Informs That Sequoyah Nuclear Plant Sewage Treatment Plant, NPDES 0026450 Outfall 112,is in Standby Status.Flow Has Been Diverted from Sys Since Jan 1998 ML20210B2521999-07-14014 July 1999 Confirms 990712 Telcon Between J Smith of Licensee Staff & M Shannon of NRC Re semi-annual Mgt Meeting Schedule for 990820 in Atlanta,Ga to Discuss Recent Sequoyah Nuclear Plant Performance ML20210J1091999-07-10010 July 1999 Submits Suggestions & Concerns Re Y2K & Nuclear Power Plants ML20196K0381999-06-30030 June 1999 Provides Written Confirmation of Completed Commitment for Final Implementation of Thermo-Lag 330-1 Fire Barrier Corrective Actions at Snp,Per GL 92-08 ML20209E4071999-06-30030 June 1999 Forwards Insp Repts 50-327/99-03 & 50-328/99-03 on 990328- 0531.Violations Being Treated as Noncited Violations ML20196J8261999-06-28028 June 1999 Forwards Safety Evaluation Authorizing Request for Relief from ASME Boiler & Pressure Vessel Code,Section XI Requirements for Certain Inservice Inspections at Sequoyah Nuclear Plant,Units 1 & 2 ML20196G7881999-06-22022 June 1999 Informs NRC of Changes That Util Incorporated Into TS Bases Sections & Trm.Encl Provides Revised TS Bases Pages & TRM Affected by Listed Revs ML20196G1801999-06-21021 June 1999 Requests Termination of SRO License SOP-20751-1,for Lf Hardin,Effective 990611.Subject Individual Resigned from Position at TVA ML20195G1821999-06-0808 June 1999 Requests NRC Review & Approval of ASME Code Relief for ISI Program.Encl 1 Provides Relief Request 1-ISI-14 That Includes Two Attachments.Encl 2 Provides Copy of Related ASME Code Page ML20195E9521999-06-0707 June 1999 Requests Relief from Specific Requirements of ASME Section Xi,Subsection IWE of 1992 Edition,1992 Addenda.Util Has Determined That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety ML20195E9311999-05-28028 May 1999 Informs of Planned Insp Activities for Licensee to Have Opportunity to Prepare for Insps & Provide NRC with Feedback on Any Planned Insps Which May Conflict with Plant Activities ML20195B3631999-05-21021 May 1999 Requests Termination of SRO License for Tj Van Huis,Per 10CFR50.74(a).TJ Van Huis Retired from Util,Effective 990514 ML20207A5721999-05-20020 May 1999 Forwards Correction to Previously Issued Amend 163 to License DPR-79 Re SR 4.1.1.1.1.d Inadvertently Omitted from Pp 3/4 1-1 of Unit 2 TS ML20206Q8791999-05-13013 May 1999 Forwards L36 9990415 802, COLR for Sequoyah Nuclear Plant Unit 2,Cycle 10, IAW Plant TS 6.9.1.14.c 05000327/LER-1999-001, Forwards LER 99-001-00 Re Condition That Resulted in Granting of Enforcement Discretion,Per Failure of Centrifugal Charging Pump.Condition Being Reported IAW 10CFR50.73(a)(2)(i)(B) & (a)(2)(iv)1999-05-11011 May 1999 Forwards LER 99-001-00 Re Condition That Resulted in Granting of Enforcement Discretion,Per Failure of Centrifugal Charging Pump.Condition Being Reported IAW 10CFR50.73(a)(2)(i)(B) & (a)(2)(iv) ML20206M9341999-05-10010 May 1999 Forwards Rept of SG Tube Plugging During Unit 2 Cycle 9 Refueling Outage,As Required by TS 4.4.5.5.a.ISI of Unit 2 SG Tubes Was Completed on 990503 ML20206K6271999-05-0606 May 1999 Requests Termination of SRO License for MR Taggart,License SOP-21336 Due to Resignation on 990430 ML20206J2061999-05-0404 May 1999 Requests Relief from Specified ISI Requirements in Section XI of ASME B&PV Code.Tva Requests Approval to Use Wire Type Penetrameters in Lieu of Plaque Type Penetrameters for Performing Radiographic Insps.Specific Relief Request,Encl ML20209J0391999-04-27027 April 1999 Forwards Annual Radioactive Effluent Release Rept, Radiological Impact Assessment Rept & Rev 41 to ODCM, for Period of Jan-Dec 1998 ML20206C0841999-04-23023 April 1999 Forwards Insp Repts 50-327/99-02 & 50-328/99-02 on 990214-0327.No Violations Noted ML20206C6541999-04-23023 April 1999 Forwards Response to NRC 990127 RAI Re GL 96-05 for Sequoyah Nuclear Plant,Units 1 & 2 ML20206B9591999-04-20020 April 1999 Responds to 990417 Request That NRC Exercise Discretion Not to Enforce Compliance with Actions Required in Unit 1 TS 3.1.2.2,3.1.2.4 & 3.5.2 & Documents 990417 Telephone Conversation When NRC Orally Issued NOED ML20205S5891999-04-17017 April 1999 Documents Request for Discretionary Enforcement for Unit 1 TS LCOs 3.1.2.2,3.1.2.4 & 3.5.2 to Support Completion of Repairs & Testing for 1B-B Centrifugal Charging Pump (CCP) ML20205M0431999-04-13013 April 1999 Eighth Partial Response to FOIA Request for Records.App Q & R Records Encl & Being Made Available in PDR 1999-09-07
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML20217M4461999-10-20020 October 1999 Forwards Rev 8 to Sequoyah Nuclear Plant Physical Security/ Contingency Plan, IAW 10CFR50.54(p).Encl Withheld,Per 10CFR73.21 05000327/LER-1999-002, Forwards LER 99-002-00 Re Start of Units 1 & 2 EDGs as Result of Cable Being Damaged During Installation of Thermo- Lag for Kaowool Upgrade Project1999-10-15015 October 1999 Forwards LER 99-002-00 Re Start of Units 1 & 2 EDGs as Result of Cable Being Damaged During Installation of Thermo- Lag for Kaowool Upgrade Project ML20217B8431999-10-0505 October 1999 Requests NRC Review & Approval of ASME Code Relief Requests That Were Identified in Plant Second 10-yr ISI Interval for Both Units.Encl 3 Provides Util Procedure for Calculation of ASME Code Coverage for Section XI Nondestructive Exams ML20217C7101999-10-0101 October 1999 Forwards Response to NRC 990910 RAI Re Sequoyah Nuclear Plant,Units 1 & 2 URI 50-327/98-04-02 & 50-328/98-04-02 Re Ice Weight Representative Sample ML20216J9351999-09-27027 September 1999 Responds to NRC Re Violations Noted in Insp Repts 50-327/99-04 & 50-328/99-04.Corrective Actions:Risk Determination Evaluation Was Performed & Licensee Concluded That Event Is in Green Regulatory Response Band ML20212A1631999-09-13013 September 1999 Forwards W Rept WCAP-15224, Analysis of Capsule Y from TVA Sequoyah Unit 1 Reactor Vessel Radiation Surveillance Program, Rev 0.Errata Sheet Containing Three Correction Pages to WCAP-15224 Also Encl ML20211N5681999-09-0101 September 1999 Submits Clarification of Two Issues Raised in Insp Repts 50-327/99-04 & 50-328/99-04,dtd 990813,which Was First Insp Rept Issued for Plant Under NRC Power Reactor Oversight Process Pilot Plant Study ML20211F8891999-08-25025 August 1999 Forwards Sequoyah Nuclear Plant Unit 1 Cycle 9 Refueling Outage, Re Completed SG Activities,Per TSs 4.4.5.5.b & 4.4.5.5.c ML20211A1851999-08-16016 August 1999 Forwards Proprietary TR WCAP-15128 & non-proprietary Rept WCAP-15129 for NRC Review.Repts Are Provided in Advance of TS Change That Is Being Prepared to Support Cycle 10 Rfo. Proprietary TR Withheld,Per 10CFR2.790 ML20211A1921999-08-12012 August 1999 Requests Proprietary TR WCAP-15128, Depth-Based SG Tube Repair Criteria for Axial PWSCC at Dented TSP Intersections, Be Withheld from Public Disclosure Per 10CFR2.790 ML20210L4291999-08-0202 August 1999 Forwards Sequoyah Nuclear Plant Unit 2 Cycle 9 12-Month SG Insp Rept & SG-99-07-009, Sequoyah Unit-2 Cycle 10 Voltage-Based Repair Criteria 90-Day Rept. Repts Submitted IAW TS 4.4.5.5.b & TS 4.4.5.5.c ML20210L1611999-07-30030 July 1999 Forwards Request for Relief RV-4 Re ASME Class 1,2 & 3 Prvs, Per First ten-year Inservice Test Time Interval.Review & Approval of RV-4 Is Requested to Support Unit 1 Cycle 10 Refueling Outage,Scheduled to Start 000213 ML20210G5301999-07-28028 July 1999 Forwards Sequoyah Nuclear Plant Unit 2 ISI Summary Rept That Contains Historical Record of Repairs,Replacement & ISI & Augmented Examinations That Were Performed on ASME Code Class 1 & 2 Components from 971104-990511 ML20210J1091999-07-10010 July 1999 Submits Suggestions & Concerns Re Y2K & Nuclear Power Plants ML20196K0381999-06-30030 June 1999 Provides Written Confirmation of Completed Commitment for Final Implementation of Thermo-Lag 330-1 Fire Barrier Corrective Actions at Snp,Per GL 92-08 ML20196G7881999-06-22022 June 1999 Informs NRC of Changes That Util Incorporated Into TS Bases Sections & Trm.Encl Provides Revised TS Bases Pages & TRM Affected by Listed Revs ML20196G1801999-06-21021 June 1999 Requests Termination of SRO License SOP-20751-1,for Lf Hardin,Effective 990611.Subject Individual Resigned from Position at TVA ML20195G1821999-06-0808 June 1999 Requests NRC Review & Approval of ASME Code Relief for ISI Program.Encl 1 Provides Relief Request 1-ISI-14 That Includes Two Attachments.Encl 2 Provides Copy of Related ASME Code Page ML20195E9521999-06-0707 June 1999 Requests Relief from Specific Requirements of ASME Section Xi,Subsection IWE of 1992 Edition,1992 Addenda.Util Has Determined That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety ML20195B3631999-05-21021 May 1999 Requests Termination of SRO License for Tj Van Huis,Per 10CFR50.74(a).TJ Van Huis Retired from Util,Effective 990514 ML20206Q8791999-05-13013 May 1999 Forwards L36 9990415 802, COLR for Sequoyah Nuclear Plant Unit 2,Cycle 10, IAW Plant TS 6.9.1.14.c 05000327/LER-1999-001, Forwards LER 99-001-00 Re Condition That Resulted in Granting of Enforcement Discretion,Per Failure of Centrifugal Charging Pump.Condition Being Reported IAW 10CFR50.73(a)(2)(i)(B) & (a)(2)(iv)1999-05-11011 May 1999 Forwards LER 99-001-00 Re Condition That Resulted in Granting of Enforcement Discretion,Per Failure of Centrifugal Charging Pump.Condition Being Reported IAW 10CFR50.73(a)(2)(i)(B) & (a)(2)(iv) ML20206M9341999-05-10010 May 1999 Forwards Rept of SG Tube Plugging During Unit 2 Cycle 9 Refueling Outage,As Required by TS 4.4.5.5.a.ISI of Unit 2 SG Tubes Was Completed on 990503 ML20206K6271999-05-0606 May 1999 Requests Termination of SRO License for MR Taggart,License SOP-21336 Due to Resignation on 990430 ML20206J2061999-05-0404 May 1999 Requests Relief from Specified ISI Requirements in Section XI of ASME B&PV Code.Tva Requests Approval to Use Wire Type Penetrameters in Lieu of Plaque Type Penetrameters for Performing Radiographic Insps.Specific Relief Request,Encl ML20209J0391999-04-27027 April 1999 Forwards Annual Radioactive Effluent Release Rept, Radiological Impact Assessment Rept & Rev 41 to ODCM, for Period of Jan-Dec 1998 ML20206C6541999-04-23023 April 1999 Forwards Response to NRC 990127 RAI Re GL 96-05 for Sequoyah Nuclear Plant,Units 1 & 2 ML20205S5891999-04-17017 April 1999 Documents Request for Discretionary Enforcement for Unit 1 TS LCOs 3.1.2.2,3.1.2.4 & 3.5.2 to Support Completion of Repairs & Testing for 1B-B Centrifugal Charging Pump (CCP) ML20205B1091999-03-19019 March 1999 Submits Response to NRC Questions Concerning Lead Test Assembly Matl History,Per Request ML20204H0161999-03-19019 March 1999 Resubmits Util 990302 Response to Violations Noted in Insp Repts 50-327/98-11 & 50-328/98-11.Corrective Actions:Lessons Learned from Event Have Been Provided to Operating Crews ML20204E8251999-03-0505 March 1999 Forwards Sequoyah Nuclear Plant,Four Yr Simulator Test Rept for Period Ending 990321, in Accordance with Requirements of 10CFR55.45 ML20207E6851999-03-0202 March 1999 Responds to NRC Re Violations Noted in Insp Repts 50-327/98-11 & 50-328/98-11.Corrective Actions:Lessons Learned from Event Have Been Provided to Operating Crews ML20207J1171999-01-29029 January 1999 Forwards Copy of Final Exercise Rept for Full Participation Ingestion Pathway Exercise of Offsite Radiological Emergency Response Plans site-specific to Sequoyah NPP ML20202A7141999-01-20020 January 1999 Provides Request for Relief for Delaying Repair on Section of ASME Code Class 3 Piping within Essential Raw Cooling Water Sys 05000327/LER-1997-013-02, Forwards LER 97-013-02 Re Addl Conditions Identified During Performance of Corrective Actions.Details Added to Revs for Two Fuses,Not Included in Surveillance Program1999-01-11011 January 1999 Forwards LER 97-013-02 Re Addl Conditions Identified During Performance of Corrective Actions.Details Added to Revs for Two Fuses,Not Included in Surveillance Program ML20198S7141998-12-29029 December 1998 Forwards Cycle 10 Voltage-Based Repair Criteria 90-Day Rept, Per GL 95-05.Rept Is Submitted IAW License Condition 2.C.(9)(d) 05000327/LER-1998-004, Forwards LER 98-004-00,providing Details Concerning Inability to Complete Surveillance within Required Time Interval1998-12-21021 December 1998 Forwards LER 98-004-00,providing Details Concerning Inability to Complete Surveillance within Required Time Interval ML20198D5471998-12-14014 December 1998 Requests That License OP-20313-2 for Je Wright,Be Terminated IAW 10CFR50.74(a).Individual Retiring ML20197J5541998-12-10010 December 1998 Forwards Unit 1 Cycle 9 90-Day ISI Summary Rept IAW IWA-6220 & IWA-6230 of ASME Code,Section Xi.Request for Relief Will Be Submitted to NRC Timeframe to Support Second 10-year Insp Interval,Per 10CFR50.55a ML20196F9841998-11-25025 November 1998 Provides Changes to Calculated Peak Fuel Cladding Temp, Resulting from Recent Changes to Plant ECCS Evaluation Model ML20195H7891998-11-17017 November 1998 Requests NRC Review & Approval of Five ASME Code Relief Requests Identified in Snp Second ten-year ISI Interval for Units 1 & 2 ML20195E4991998-11-12012 November 1998 Forwards Rev 7 to Physical Security/Contingency Plan.Rev Adds Requirement That Security Personnel Will Assess Search Equipment Alarms & Add Definition of Major Maint.Rev Withheld (Ref 10CFR2.790(d)(1)) ML20195G5701998-11-10010 November 1998 Documents Util Basis for 981110 Telcon Request for Discretionary Enforcement for Plant TS 3.8.2.1,Action B,For 120-VAC Vital Instrument Power Board 1-IV.Licensee Determined That Inverter Failed Due to Component Failure 05000328/LER-1998-002, Forwards LER 98-002-00 Re Automatic Turbine & Reactor Trip, Resulting from Failure of Sudden Pressure Relay on B Phase Main Transformer1998-11-10010 November 1998 Forwards LER 98-002-00 Re Automatic Turbine & Reactor Trip, Resulting from Failure of Sudden Pressure Relay on B Phase Main Transformer ML20155J4031998-11-0505 November 1998 Provides Clarification of Topical Rept Associated with Insertion of Limited Number of Lead Test Assemblies Beginning with Unit 2 Operating Cycle 10 Core ML20154R9581998-10-21021 October 1998 Requests Approval of Encl Request for Relief ISI-3 from ASME Code Requirements Re Integrally Welded Attachments of Supports & Restraints for AFW Piping ML20155B1481998-10-21021 October 1998 Informs That as Result of Discussion of Issues Re Recent Events in Ice Condenser Industry,Ice Condenser Mini-Group (Icmg),Decided to Focus Efforts on Review & Potential Rev of Ice condenser-related TS in Order to Clarify Issues ML20154K1581998-10-13013 October 1998 Forwards Rept Re SG Tube Plugging Which Occurred During Unit 1 Cycle 9 Refueling Outage,Per TS 4.4.5.5.a.ISI of Unit 1 SG Was Completed on 980930 ML20154H6191998-10-0808 October 1998 Forwards Rev 0 to Sequoyah Nuclear Plant Unit 1 Cycle 10 COLR, IAW TS 6.9.1.14.c 05000328/LER-1998-001, Forwards LER 98-001-00 Providing Details Re Automatic Turbine & Reactor Trip Due to Failure of Sudden Pressure Relay on B Phase Main Transformer1998-09-28028 September 1998 Forwards LER 98-001-00 Providing Details Re Automatic Turbine & Reactor Trip Due to Failure of Sudden Pressure Relay on B Phase Main Transformer 1999-09-27
[Table view] Category:UTILITY TO NRC
MONTHYEARML20059K6661990-09-17017 September 1990 Forwards Evaluation That Provides Details of Plug Cracks & Justification for Continued Operation Until 1993 ML20059H4031990-09-10010 September 1990 Discusses Plant Design Baseline & Verification Program Deficiency D.4.3-3 Noted in Insp Repts 50-327/86-27 & 50-328/86-27.Evaluation Concluded That pre-restart Walkdown Data,Loops 1 & 2 Yielded Adequate Design Input ML18033B5031990-08-31031 August 1990 Forwards Financial Info Required to Assure Retrospective Premiums,Per 10CFR140 & 771209 Ltr ML20059H1831990-08-31031 August 1990 Forwards Nonproprietary PFE-F26NP & Proprietary PFE-F26, Sequoyah Nuclear Plan Unit 1,Cycle 5 Restart Physics Test Summary, Re Testing Following Vantage 5H Fuel Assembly installation.PFE-F26 Withheld (Ref 10CFR2.790(b)(4)) ML20059E2881990-08-31031 August 1990 Forwards Addl Info Re Alternate Testing of Reactor Vessel Head & Internals Lifting Rigs,Per NUREG-0612.Based on Listed Hardships,Util Did Not Choose 150% Load Test Option ML20059E1851990-08-31031 August 1990 Responds to NRC Re Violations Noted in Insp Repts 50-327/90-22 & 50-328/90-22.Corrective Actions:Extensive Mgt Focus Being Applied to Improve Overtime Use Controls ML20028G8341990-08-28028 August 1990 Forwards Calculation SCG1S361, Foundation Investigation of ERCW Pumping Station Foundation Cells ML20063Q2471990-08-20020 August 1990 Submits Implementation Schedule for Cable Tray Support Program.Util Proposes Deferral of Portion of Remaining Activities Until After Current Unit 2 Cycle 4 Refueling Outage,Per 900817 Meeting.Tva Presentation Matl Encl ML20056B5181990-08-20020 August 1990 Responds to NRC Re Order Imposing Civil Monetary Penalty & Violations Noted in Insp Repts 50-327/90-01 & 50-328/90-01.Corrective Actions:Organizational Capabilities Reviewed.Payment of Civil Penalty Wired to NRC ML20063Q2461990-08-17017 August 1990 Forwards Cable Test Program Resolution Plan to Resolve Issues Re Pullbys,Jamming & Vertical Supported Cable & TVA- Identified Cable Damage.Tva Commits to Take Actions Prior to Startup to Verify Integrity of safety-related Cables ML20059A5121990-08-15015 August 1990 Provides Clarification of Implementation of Replacement Items Project at Plant for Previously Procured Warehouse Inventory.Util Committed to 100% Dedication of Commercial Grade,Qa,Level Ii,Previous Procurement Warehouse Spare ML20058M2321990-08-0707 August 1990 Forwards Rept of 900709 Fishkill,Per Requirements in App B, Environ Tech Spec,Subsections 4.1.1 & 5.4.2.Sudden Water Temp Increase Killed Approximately 150 Fish in Plant Diffuser Pond ML20058N2361990-08-0707 August 1990 Confirms That Requalification Program Evaluation Ref Matl Delivered to Rd Mcwhorter on 900801.Ref Matl Needed to Support NRC Preparation for Administering Licensed Operator Requalification Exams in Sept 1990 ML20058M0111990-07-27027 July 1990 Forwards Addl Info Re Plant Condition Adverse to Quality Rept Concerning Operability Determination.Probability of Cable Damage During Installation Low.No Programmatic Cable Installation Problems Exist ML20055J3531990-07-27027 July 1990 Forwards Revised Commitment to Resolve EOP Step Deviation Document Review Comments ML20058M4471990-07-27027 July 1990 Responds to Unresolved Items Which Remain Open from Insp Repts 50-327/90-18 & 50-328/90-18.TVA in Agreement W/Nrc on Scope of Work Required to Address Concerns W/Exception of Design Basis Accident & Zero Period Accelaration Effects ML20055J0771990-07-26026 July 1990 Requests Termination of Senior Reactor Operator License SOP-20830 for Jh Sullivan Due to Resignation from Util ML20055G6611990-07-17017 July 1990 Forwards Justification for Continued Operation for safety- Related Cables Installed at Plant,Per 900717 Telcon.No Operability Concern Exists at Plant & No Programmatic Problems Have Been Identified.Summary of Commitments Encl ML20058L7001990-07-16016 July 1990 Forwards Response to SALP Repts 50-327/90-09 & 50-328/90-09 for 890204 - 900305,including Corrective Actions & Improvements Being Implemented ML20055F6151990-07-13013 July 1990 Provides Addl Bases for Util 900320 Proposal to Discontinue Review to Identify Maint Direct Charge molded-case Circuit Breakers Procured Between Aug 1983 & Dec 1984,per NRC Bulletin 88-010.No Significant Assurance Would Be Expected ML20044B2211990-07-12012 July 1990 Forwards Addl Info Clarifying Certain Conclusions & Recommendation in SER Re First 10-yr Interval Inservice Insp Program ML20055D2531990-07-0202 July 1990 Provides Status of Q-list Development at Plant & Revises Completion Date for Effort.Implementation of Q-list Would Cause Unnecessary & Costly Delays in Replanning Maint,Mod, outage-related Activities & Associated Procedure Revs ML20043H9061990-06-21021 June 1990 Responds to Generic Ltr 90-04, Request for Info on Status of Licensee Implementaion of Generic Safety Issues Resolved W/Imposition or Requirements or Corrective Actions. No Commitments Contained in Submittal ML20043H2281990-06-18018 June 1990 Informs of Issue Recently Identified During Startup of Facility from Cycle 4 Refueling Outage & How Issue Addressed to Support Continued Escalation to 100% Power,Per 900613 & 14 Telcons ML20043G4901990-06-14014 June 1990 Forwards Tabs for Apps a & B to Be Inserted Into Util Consolidated Nuclear Power Radiological Emergency Plan ML20043F9301990-06-13013 June 1990 Responds to NRC Re Violations Noted in Insp Repts 50-327/90-17 & 50-328/90-17.Corrective Action:Test Director & Supervisor Involved Given Appropriate Level of Disciplinary Action ML20043F9261990-06-13013 June 1990 Responds to NRC Bulletin 89-002, Stress Corrosion Cracking of High-Hardness Type 410 Stainless Steel Internal Preloaded Bolting in Anchor/Darling Model S3502 Swing Check Valves or Valves of Similar Design ML20043H0361990-06-11011 June 1990 Forwards Supplemental Info Re Unresolved Item 88-12-04 Addressing Concern W/Double Differentiation Technique Used to Generate Containment Design Basis Accident Spectra,Per 900412 Request ML20043D9921990-06-0505 June 1990 Responds to NRC Re Violations Noted in Insp Repts 50-327/90-14 & 50-328/90-14.Corrective Actions:Util Reviewed Issue & Determined That Trains a & B Demonstrated Operable in Jan & Apr,Respectively of 1989 ML20043C0581990-05-29029 May 1990 Forwards Response to NRC 900426 Ltr Re Violations Noted in Insp Repts 50-327/90-15 & 50-328/90-15.Response Withheld (Ref 10CFR73.21) ML20043C2821990-05-29029 May 1990 Requests Relief from ASME Section XI Re Hydrostatic Pressure Test Requirements Involving RCS & Small Section of Connected ECCS Piping for Plant.Replacement & Testing of Check Valve 1-VLV-63-551 Presently Scheduled for Completion on 900530 ML20043B3051990-05-22022 May 1990 Forwards Detailed Scenario for 900711 Radiological Emergency Plan Exercise.W/O Encl ML20043B1201990-05-18018 May 1990 Forwards, Diesel Generator Voltage Response Improvement Rept. Combined Effect of Resetting Exciter Current Transformers to Achieve flat-compounding & Installing Electronic Load Sequence Timers Produced Acceptable Voltage ML20043A6101990-05-15015 May 1990 Forwards Rev 16 to Security Personnel Training & Qualification Plan.Rev Withheld (Ref 10CFR2.790) ML20043A2391990-05-15015 May 1990 Forwards Revised Tech Spec Pages to Support Tech Spec Change 89-27 Re Steam Generator Water Level Adverse Trip Setpoints for Reactor Trip Sys Instrumentation & Esfas. Encl Reflects Ref Leg Heatup Environ Allowance ML20043A0581990-05-11011 May 1990 Forwards Cycle 5 Redesign Peaking Factor Limit Rept for Facility.Unit Redesigned During Refueling Outage Due to Removal & Replacement of Several Fuel Assemblies Found to Contain Leaking Fuel Rods ML20043A0571990-05-10010 May 1990 Forwards List of Commitments to Support NRC Review of Eagle 21 Reactor Protection Sys Function Upgrade,Per 900510 Telcon ML20042G4651990-05-0909 May 1990 Provides Addl Info Re Plant Steam Generator Low Water Level Trip Time Delay & Function of P-8 Reactor Trip Interlock,Per 900430 Telcon.Trip Time Delay Does Not Utilize P-8 Interlock in Any Manner ML20042G4541990-05-0909 May 1990 Provides Notification of Steam Generator Tube Plugging During Unit 1 Cycle 4 Refueling Outage,Per Tech Specs 4.4.5.5.a.Rept of Results of Inservice Insp to Be Submitted by 910427.Summary of Tubes Plugged in Unit 1 Encl ML20042G9771990-05-0909 May 1990 Responds to NRC Re Violations Noted in Insp Repts 50-327/90-01 & 50-328/90-01 & Proposed Imposition of Civil Penalty.Corrective Actions:Rhr Pump 1B-B Handswitch in pull- to-lock Position to Ensure One Train of ECCS Operable ML20042G0441990-05-0808 May 1990 Forwards Nonproprietary WCAP-11896 & WCAP-8587,Suppl 1 & Proprietary WCAP-8687,Suppls 2-E69A & 2-E69B & WCAP-11733 Re Westinghouse Eagle 21 Process Protection Sys Components Equipment Qualification Test Rept.Proprietary Rept Withheld ML20042G1701990-05-0808 May 1990 Provides Addl Info Re Eagle 21 Upgrade to Plant Reactor Protection Sys,Per 900418-20 Audit Meeting.Partial Trip Output Board Design & Operation Proven by Noise,Fault,Surge & Radio Frequency Interference Testing Noted in WCAP-11733 ML20042G1431990-05-0808 May 1990 Forwards WCAP-12588, Sequoyah Eagle 21 Process Protection Sys Replacement Hardware Verification & Validation Final Rept. Info Submitted in Support of Tech Spec Change 89-27 ML20042G1001990-05-0808 May 1990 Forwards Proprietary WCAP 12504 & Nonproprietary WCAP 12548, Summary Rept Process Protection Sys Eagle 21 Upgrade,Rtd Bypass Elimination,New Steam Line Break Sys,Medical Signal Selector .... Proprietary Rept Withheld (Ref 10CFR2.790) ML20042G1231990-05-0707 May 1990 Forwards Detailed Discussion of Util Program & Methodology Used at Plant to Satisfy Intent of Reg Guide 1.97,Rev 2 Re Licensing Position on post-accident Monitoring ML20042F7741990-05-0404 May 1990 Informs of Completion of Eagle 21 Verification & Validation Activities Re Plant Process Protection Sys Upgrade.No Significant Disturbances Noted from NRC Completion Date of 900420 ML20042F1691990-05-0303 May 1990 Responds to NRC Bulletin 88-009, Thimble Tube Thinning in Westinghouse Electric Corporation Reactors. Wear Acceptance Criteria Established & Appropriate Corrective Actions Noted. Criteria & Corresponding Disposition Listed ML20042G1381990-04-26026 April 1990 Forwards Westinghouse to Util Providing Supplemental Info to Address Questions Raised by NRC Re Eagle-21 Process Protection Channels Required for Mode 5 Operation at Facilities ML20042E9641990-04-26026 April 1990 Forwards Rev 24 to Physical Security/Contingency Plan.Rev Withheld (Ref 10CFR73.21) ML20034B5971990-04-24024 April 1990 Requests NRC Approval to Consider Eagle 21 Sys Operable Prior to NRC Approval of Tech Spec Change 89-27 as Change Applies to Several Indication Only Instrument Channels Utilized in Mode 5 1990-09-17
[Table view] |
Text
{{#Wiki_filter:. _ _ . _ _ _ _ _ _ . _ _ _ . _. . _ _.
.e TENNESSEE VALLEY AUTHORITY :
' CH ATTANOOGA. TENNESSEE 37401 SN 157B Lookout Place MAY 221987 U.S. Nuclear Regulatory Comission ATTN: Document Control Desk i Washington, D.C. 20555 Gentlemen:
In the Matter of ) Docket Mos. 50-327 Tennessee Valley Authority ) 50-328 SEQUOYAH NUCLEAR PLANT (SQN) UNITS 1 AND.2 - ENGINEERING CHANGE NOTICE (ECN) CLOSEOUT AND FSAR UPDATES - SUPPLEMENTAL RESPONSE e
This supplemental response to Gary G. Zech's letter to S. A. White dated
-December 18, 1986, regarding the ECN closure effort and_the FSAR discrepancy described in SQ-CAR-86-04-21, is provided in accordance with'a l request from Frank McCoy and Morris Branch during an April. 10, 1987 meeting at SQN. The initial response to Mr. Zech's December 18, 1986 letter was provided in a letter to J. Nelson Grace from J. A. Domer dated i February 3, 1987. Enclosure 1 of this supplemental response provides. '
additional information about the ECN closure effort and enclosure 2 provides additional information about the FSAR corrective actions.
Enclosure 3 contains the list of comitments in enclosures 1 and 2.
~
) If you have any questions, please call M. R. Harding at (615) 870-6422.
1 To the best of my knowledge, I declare the statements contained herein are complete and true.
+
i 1 Very truly yours, TENNESSEE VALLEY AUTHORITY
. d.
)J.A.Domer,AssistantDirector Nuclear Safety and Licensing Enclosures cc: See page 2 i
~
i 4
8706030144 870522 7-PDR ADOCK 0500 P
An Equal Opportunity Employer
U.S. Nuclear _ Regulatory Conunission f hj h[
cc (Enclosures):
Mr. G. G. Zech, Assistant Director for Inspection Programs Office of Special Projects Division of TVA Projects
! U.S. Nuclear Regulatory Commission 1 Region II 101 Marietta Street, NW, Suite 2900-Atlanta, Georgia 30323 Mr. J. A. Zwolinski, Assistant Director
. for Projects Division of TVA Projects Office of Special Projects i U.S. Nuclear Regulatory Commission 4350 East West Highway
. EWW 322 J Bethesda, Maryland 20814.
l Sequoyah Resident Inspector i Sequoyah Nuclear Plant i 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 1
.I
}
r I
4 i'
1 i
t e
i
E
. ENCLOSURE 1
. SUPPLEMENTAL INFORMATION REGARDING THE ECN CLOSURE EFFORT This enclosure provides details about the type and complexity of ECNs -
- which have been closed by the ECM closure effort, compensatory measures taken which address the minor discrepancies identified during the closure -
i
- effort, and the manpower allocations required to support closure of the
- _i ECW backlog at SQN by October 1988 as committed in TVA's original response.
As described in TVA's original response, the ECN closure group has closed
! approximately 100 ECNs (selected at random) from the ECN backlog at SQN.
j Attachment 1 provides a breakdown of the 104 ECNs closed by this effort.
i From the table in attachment 1, it can be seen that this effort affected a cross section of the modification disciplines (principally mechanical and i electrical). Of the 104 ECNs closed, 43 were mechanical (M), 44 were electrical (E), 10 were civil (C), and seven were mixed disciplines..
These ECNs ranged in complexity from affecting one system and no drawings !
I
, to involving three systems and 42 drawings. An average of four to five I drawings and one to three workplans per ECN were closed in this effort, i l Attachment 2 provides a key to the system numbers used in attachment 1.
f As explained in TVA's original response, the types of errors identified by the ECN closure process have been minor in nature. The one area of 4
discrepancy that does appear more often, however, is with the 47W611
} series logic diagrams. This drawing series, because of the number of 4 discrepancies identified, has been removed from the main control room (MCR). The operations personnel instead rely on other MCR drawings (e.g.,
1 flow, control, and single-line diagrams). TVA's current plans involve
- including seven of the principle logic diagrams in the "as constructed"
- drawing program to be verified and corrected before unit 2 restart in I accordance with SQN's previous commitments (letter from R. Gridley to J. Nelson Grace dated December 12, 1986).
i
! The schedule for closure of the ECM backlog at SQN as provided in TVA's original response is to close the approximately 1,200 ECNs by October 15, 1988. Approximately 670 of those are on Critical Structures, Systems, and Components (CSSC). This schedule is based on six full-time .
- individuals working in the closure group and approximately 19 man-hours l
, required to review each ECN for closure. Although not a commitment, SQN's l schedule for completion of the 670 CSSC ECNs is December 1987, with the
- balance of the backlog resolved by October 15, 1988 (as previously j committed). This schedule supports inclusion in the 1989 FSAR update and
- completion of the FSAR corrective actions described in SQN's original response.
I i
i
.i d
1
, _ - .~. .___.-____ ~__ _ _ _ - - . _. . _ _ _ __. . ._ - - - - -
i l
ENCLOSURE 2 SUPPLEMENTAL INFORMATION REGARDING FSAR CORRECTIVE ACTIONS TVA's original response provided the corrective actions planned to resolve i
the FSAR discrepancies. This supplemental response describes SQN's efforts to compensate for the FSAR discrepancies when internal TVA -
reviews / evaluations and NRC review / evaluations involving the FSAR are conducted. Additionally, this response describes how discrepancies identified during the FSAR verification program will be handled.
l On January 28, 1987, the Site Licensing Staff issued a memorandum from-l M. R. Harding to L. M. Nobles (Acting Plant Manager) and D. W. Wilson,
+
Division of Nuclear Engineering.(DNE), concerning 10 CFR 50.59 evaluations. This memorandum stated that, in preparation of Unreviewed Safety Question Determinations (USQD), evaluators are not to rely solely i on the FSAR. . SQN's technical specifications, verified "as-constructed" drawings, verified design criteria, and.other resources should be utilized in addition to the FSAR for USQD evaluations. SQN Standard Practice (SQA)-119. "Unreviewed Safety Question Determination," has been revised to incorporate this polict. Likewise, DNE SQN Project is issuing a memorandum to ensure that the FSAR is not the sole source of information 4 in preparation of USQDs and modification packages and will issue Nuclear Engineering Procedure (NEP)-6.6, " Safety Evaluations," by June 30, 1987, to include this policy.
Because of the deficiencies with the SQN FSAR, TVA will provide a copy of
. critical "as-constructed" drawings to NRC Washington and Region II Incident Response Centers by June 30, 1987. These drawings will include flow, logic, control, and single-line drawings for those systems esstatial to safely operate the plant and are currently included in the FSAR. TVA's plans for periodically updating the drawings provided to NRC's incident response centers will be included in the June 30, 1987 drawing submittal referenced above. This will provide NRC with up-to-date information to assist in responding to and analyzing emergency situations that may-i arise. Furthermore, TVA will provide specific information, in~each I application, as necessary to support technical specification changes by
! supplementing the FSAR where deficiencies exist.
! The FSAR Verification Program (described in TVA's initial response) will l use the established corrective action program (Administrative Instruction j [AI]-19, Part 1, " Conditions Adverse to Quality") to currect design j discrepancies identified during the verification process. This approach
- will ensure that Conditions Adverse To Quality (CAQs) are promptly l identified, documented, evaluated, corrected, and reported to management l in a manner consistent with their importance to safety.
i 1
\
ENCLOSURE S LIST OF COMMITMENTS
- 1. By June 30, 1987, DNE will issue NEP-6.6 to include the policy for not solely relying on the SQN FSAR for 10 CFR 50.59 evaluations.
- 2. By June 30, 1987, provide NRC copies of the critical "as-constructed" drawings for SQN restart'and TVA's plans for periodically updating those drawings. These drawings will include flow, logic, control and-single-line drawings for those systems essential to operate the plant and are currently included in the FSAR.
\
.I i
a 4
i i
1 J
r . , - -. . , . . . ,- , - - - - , _ , . ,- -, _ ., .:.__,,_.., _ . , . , -- -- - - , . , - , - -
Attachm nt 1 ECN SYSTEM DISC tPL/AfE jlll #?c'R "$?Nxb L500 ?. 26 M l 'N lO L 5'0 3 7 87 E I I to L 506 5 M ff l O y Lso70 26 M l l 2 tso7a l7 m a i 27 Lst c2. 2 E / o 15 L sits' 7tf E 2 I /7 Ls/17 t}3 E / / /
<_ s/56 6 e. ' C, E a / '3 L5175 43 E i I 6 LSI84 30 M l l 3 Lstse 30 m I o 7 L S/9 2. 30 M / / tl L520L 90 E l 0 i L 52/2 Jo, 3/c, 45 M a o 3 L 5822 5& E 2 0 3
_LS223 87 E / O e L5224 VArt r ous E 3 o 6 LG228 6s M l c if Ls? 33 90 E */ Q L5238 3
6l M f o O L524I $ 68, 77 E I o G t- 52 43 45 E,M t O 3 Lsc45 3 E / o l L5as 1 96 M / O 2 L527C Sb M y L52'8 l {
31 M i / /
ts284 30 E, An ; e. ty L s 2 c/ 3 2/ 7 'C / o~ /
c530c 67 5 l 6 j g a.5eut i.s fon : vs rem:, 3, cc, 63, 68, 77 e 7
. Attachmsnt 1 2-ECN SYSTEM D/ScIPUME ""l##l,l,; #f#f#" #"lf#l
~
L53/4- 3 E 2. / /2.
L5349 78 M / 0 II L53se G3 E I 2. 9 L5364 77 M / 0 i Ls367 92. E / o /
L 5344 30 ? C Ls370
/ E 4 86 M 3 L54ao 3a
/ //
E / O /
L5430 (- E l 0 f LG456 62 L5463 N1 l 0 3 68 E LS490 / f 6 44 6 C- l ( 2.
LSSI3 3/ 7 E / O e L 55/7 7? C l l Q, LSS41 67 M t SS53
/ Q ?
3/7 M I L5557 249 C O / \
/ e 4 L Ss&7 /, 3 C l L5605 l 0 /gg 26 N\ ?.-
L S608 0 3 l 68 C 2.
ts632 .3 6 O z 2 0 /3 Ls633 ?6 M 2. O 3 LsC72 UT E L5678
/ O 5 SS, 6 2. E I O 7 L 57co 3c E, y j L 5762 f3 j
Q
(, AA L s7/b 24l j c 5-L= l c j L 57/7 T E l 0 3 LG725 7S M / O 3 L5'31 67, 70, ei3 l= l / if L
- Attachment 1 3
ECN sYS TEM DIScIPLtME "$$$laj #lc'n's' "b$bx?s LS734 7tl E l o j L57t/5 3i I o A3 l L5748 bl & l 0 j L5756 3 M j g y LS 757 l
, lH E o l L5740 3 E j e 3 LS76Y 39 /M l '
L s768 t.) ll fe 5 l g z L 5 777 g,- =
j g 3 L S 780 43 5 , , g L G781 3l 5 j g ,
L 5785 70 M j c z L G726 87
'S?S9 4 g a ,
I,3 E z j Ls795 7j 3 p , o z L5797 f3 p j 9 ,
L 5'96 7e *1 l o j L 58*7 88 C e e 4 Lse6 / 27 g j j 7 L 5'!54 ea A1 e i ,
Ls%3 1 m j g ,
L5972 97 M 2 l z LS973 68 prl ,
L5985 74 3 o
& l o q_
L5993 90 5 7 , ,
L5996 303 C j , ,
LG999 4c E L60"
/ o 3 l & f a 2. !
Llo35 260 e , , 7 L LCS'l 4/ A1 l l z l O
, , . - -,, , , - - n.-., -,.,-- , ,
. Attachment 1
- ECN SYSTEM DisctPL/MG "$$fl, *# #fff,' "lllgg*#3 L&os8 l
^
m l l l L 6od3 8a /v\ / o /
L607t/ yy m j j g L6690 IL E l 0 g L 6/c a fg g m j j L6/06 W E l o il L6/a a 70 C / l 4/.
L6 TBS 3 m j y y L6/75 32 E / j j L6/ 95 gc E, p 7 j , i L6/ 98 g z. 5,m j , z Lf228 3 y g ; ;
L6273 qq g j q g LL362 yy y j g g l
1
.: n i 1,
Attachmsnt 2 y '
Standard Practice Page 66 T SQM2 .
Revision 23 f ATTACHMENT.C
< SYSTEM CODES 1 Main Steam System inc1'uding Steam Generator Blowdown 2 Condensate System ..t
._ _. l . c 3 Main,and Aux 111ary Feedwater System ~
I' . 5 Extraction Steam System -
{
,I.?, :
6 Heater Drains and Vents System ~.I; .
f 7 TurbineExtractionTrapsandDra[nsSystem _ f ,, -{:: -
8 Miscellaneous Turbine Connections ,
. . .. _..[.f.z, 9 Misc 511aneousTurbinehentSystems -
~ ..
4 -
12 Aux 111ary Boller Systems 13
,.- Fire Protection i0ther than HPFP and-C02 fire protection) Systems
~
. 14 Condensate emineralizer System '
~
15 Steam Generator Blowdown System I
18 Fuel 011 System ,,
19 Lig5 ting - Off 011 and Air Piping System 20 Central Lubricating 011 System 24 Raw Cooling Hater System 25 Raw Service Hater System' 26 High-Pressure Fire-Protection System .
27 Condenser Circulating Hater System 28 Hater Treatment System 29 Potable Water Olstribution System L
t 30 Ventilation System 0323S/ jaw w
e
- e
. .~
Attachment 2. '
- p. * -
Standard Practice Page 67 .
SQM2 .
Revision 23 ATTACHMENT C (Continued)
SYSTEM CODES -
Heating and Air Conditioning System 31 32 Control Air System .
~
, . 33 S'ervice Air System "
. 34 Vacuum Priming System -
35 Generator Cooling System ..
' ; ~
36 Feedwater Secondary Treatment System -
~
~~ ' ~ ~
37 G1,and Seal Water System ~ ~ - - - ~ ~ ~
38 Insulating 011 System '
39 CO, Storage,. Fire Protection, and Purging System 40 .StitionDrainageSystem 41 Layup Ha'ter Treatment System' 42 Chemical Cleaning System 43 Sampling and Water Control System.
~
44 Bullding Heating System (Instruments and Controls) 46 Feedwater Control System
, 47 Turbogenerator Control System 49 Breathing Air System l l -
50 Hypochlorits System 51 Raw Water Chlorination (Acrolein) System -
~
52 System Test Facility (Instrumentation) 54 Injection Water System ;
1 0323S/dri n
e o
~ ._ .'
e , ;
', Attachment 2 ,
Standard Practice
^
Page 68 t~ SQM2 .' '
Revision 23 ATTACHMENT C (Continued)
, SYSTEM CODES 55 Annunciator and Sequential Events Recording System f 56 Tempe,rature Monitoring System
, 57 Genfrator Associated Electrical System (Including
.. Protection, Excitation, and Voltage Regulation) -
58 Main Generator Bus Cooling System 4 .,
f 59 Demineralized Water'and Cask Decontamination
'e 61 Ice Condenser System -
(',
- l. ,. .
.-n-
- 1. 62 Chemical and Volume Control System ,. , , ,
~
63 Safety Injection Systeiri 64 Ice Condenser Containment System .
65 Emergency Gas Treatment System 67 Essential Raw Cooling Water (ERCH) System 68 Reactor Coolant System 70 Component Cooling System
. 72 Containment Spray System 74 Residual Heat Removal System 77 Waste Disposal System 78 Spent-Fuel-Pit Cooling System (Fuel Holding and Cranes) l s
79 Fuel Handling Tools and Fixtures 80 Primary Containment Cooling System 81 Primary Makeup Hater System
. 0323S/ jaw ,
, Attachment 2 ,
<. '*s M
Standard Practice Page 69 p ,,. SQM2 .',
Revision 23 ATTACHMENT C ,
, (Continued) .
- SYSTEM CODES _.
82 Standby Diesel Generator System '" )
f 83 Hy,drogen Recombination System 2,,
84 ,ffood Mode Boration System- .
[ .. . - ~,
f { 85 Control Rod Drive System .
t ,
86 Diesel Starting Air System #Y, a t:
87 Upper Head Injection System - -
~ ~'
88 -Containment Isolation System - - 7. ' 'i ~ Ci= z
~
l 90 Radiation Monitoring System -
f 92 94 Neutron'Monttoring System
{ ,, _ Incore Flux Detectors
~
, 99 Reactor Protection System
- 114 Plant Equipment - General Support and Minor Maintenance-4
![i Performed in Response to SI-114.1 and SI-114.2 150 _ Measuring and . Test Equipment 4 ,
162 Plant Equipment - General Support and Minor Maintenance i Performed in Response to SI-162.1 and 51-162.2 l 200 Status Monitor System .
! 201 480-V Electrical Boards and MCC
)
202 6900-V Electrical Boards (and Logic Panels)
! 234 Heat Tracing System .
241 Stic' yard n and Transformers 244 Communications Systems 245 Security Systems
- . 0323S/ jaw l
w l
8 p
, Attachment 2 F , i i: Standard Practice Page 70 .
SQM2 .
Revision 23 ATTACHMENT C (Continued)
SYSTEM CODES 247 Lighting Systems I
4 f 250 250,V DC,125-V, DC,120-V AC, Low Voltage Power .
255 Dat[LoggerandAcquisitionSystem
[. ., ...
L 260 Chemical Lab Test Equipment -
~
i
[ 263 Condenser Tube Cleaning System -
a [ ;
, 264 Technical Support System ' -
[ 265 Health Physics Test Lab Equipment ' -7 ' "
"A " '" '-
- 1. . c. , . .
266 Mechanical Test Equipment 268 Permanent Hydrogen Mitigation System
, 282- Fleid Services Facility Electrical System l 283 Low Level Rad Waste Facility ' ' '
- r 301 Computer Systems
. 1 302 Penetrations i
_. s T1 303 Cranes 305 Sewage f 306 Hiscellaneous Office Equipment 307 Elevators -
309 Recirculation Flow Control l 311(31A) Control Building HVAC
~
312(318) Yard and Miscellaneous Mechanical Unit Equipment
; 313(31C) Aux 111ary Building HVAC (Instrument and Valves) i, i
0323S/dr1 4
4
.r .
. . . _ _ . . ~ _ _ _ , . . , _ . __ _ _ , _ , . . . _ . . _ _ . . , - . , _ , _ _ _ _ . . _ _ . . - _ _ _ , . . , _ . . . _ ,
. , l V. ,
. Attachment 2.,
" 6 '
Standard Pract' ice ' Page 71
'- SQM2 '
Revision 23 1
' ATTACHMENT C (Continued)
SYSTEM CODES .
317 Miscellaneous and Power Outlets -
320 Holsts and Platforms 350 IWstrument Hangers l .
352 Instrument Conduit Hangers t .
361 Cables ~ -
362 Cable Trays .
~
i 363 Condutt ,
,- ~.' -- " 1. 2.
Rolling Doors
~
410 ,,
f 500 Instrument Panels, Control Room, and Status Monitor Boards -
928 ,' Makeup Hater Treatment Plant 959 Demineralized Water Storage and Dis 991
- Junction Boxes Some records exist with junction boxes identified as system 360.
u J
I 1
a 0323S/ jaw I
L. .
.-. - _ _ : __ -. . _ - - - - . - . ..}}