Category:OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING
MONTHYEARML20129E3801996-10-14014 October 1996 Application for Amend to License DPR-54,representing Updated Licensing Basis for Operation of Shutdown Rancho Seco Nuclear Facility During Permanently Defueled Mode ML20058L4281993-12-0909 December 1993 Application for Proposed License Amend 187 to DPR-54 Re Changes Needed to Make PDTS Consistent W/New 10CFR20 Regulations.New 10CFR20 Effective 940101 ML20127N3291993-01-19019 January 1993 Application for Amend to License DPR-54,consisting of Proposed Amend 186,changing Organization & Requests Changes to Permanently Defueled Tech Specs Section D6.0 Administrative Controls Pages ML20246F0991989-07-0505 July 1989 Application for Amend to License DPR-54,resubmitting Rev 1 to Proposed Amend 102,deleting Remaining Nonradiological Items Contained in App B of Tech Specs.Shutdown of Facility on 890607 Makes Submittal of Improved Specs Impractical ML20235Y6011989-03-0606 March 1989 Application for Amend to License DPR-54,consisting of Suppl 1 to Proposed Amend 175,Rev 0,for one-time Extension for Certain Surveillances Required by Tech Specs to Be Performed Beginning 890329 ML20245H8851989-02-28028 February 1989 Rev 1 to Proposed Amend 130 to License DPR-54,adding Operating Requirements to Tech Specs Designed to Provide Proper Limitations & Conditions on Reactor Bldg Pressure Equalization Operations During Power Operation ML20195F7641988-11-18018 November 1988 Rev 1 to 881007 Proposed Amend 170,defining Applicability Requirements of Tech Spec 3.4 W/Respect to Auxiliary Feedwater Sys Flow Paths.Rev Deletes Words to the Condenser from Spec 4.8.1 ML20206F2811988-11-15015 November 1988 Suppl 1 to 880930 Application for Amend 166,Rev 1 to License DPR-54 Revising Tech Spec 4.6.4.f to Ensure Equipment Required to Verify Vital 120 Volt Ac Bus Operability ML20205R8631988-11-0404 November 1988 Application for Amend to License DPR-54,consisting of Rev 1 to Proposed Amend 172,withdrawing Request to Delete Reactor Bldg Spray Line Requirements & Justifying Removal of DHR Inlet Lines ML20205M8881988-10-28028 October 1988 Application for Amend 169 to License DPR-54,modifying Nuclear Svc Battery Surveillance Requirements.Fee Paid ML20205L2611988-10-25025 October 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 173,modifying Tech Spec 3.14 to Remove Requirements for Fire Suppression Sys in Fire Zones 75-80. Fee Paid ML20155G2161988-10-0707 October 1988 Application for Amend to License DPR-54,clarifying Operational Mode Applicability of Tech Spec 3.4 & Definition of Auxiliary Feedwater Sys Train.Fee Paid ML20155B8111988-09-30030 September 1988 Application for Rev 1 to Amend 166 to License DPR-54, Revising Tech Specs Re Reactor Protection Sys Trip Setting Limits by Making Editorial Corrections & Technical Changes ML20155B4251988-09-30030 September 1988 Application for Amend to License DPR-54,making Editorial Corrections & Administrative Changes.Fee Paid ML20154J5521988-09-19019 September 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 172,changing Local Leak Rate Test Requirements for Containment Penetrations.Fee Paid ML20154D7531988-09-0808 September 1988 Application for Amend to License DPR-54,consisting of Rev 1 to Amend 168,replacing Organization Charts W/More General Administrative Controls CEO-88-024, Supplemental Application for Amend to License DPR-54, Consisting of Rev 1 to Proposed Amend 102,deleting App B of Tech Specs1988-07-27027 July 1988 Supplemental Application for Amend to License DPR-54, Consisting of Rev 1 to Proposed Amend 102,deleting App B of Tech Specs CEO-88-002, Application for Proposed Amend 130 to License DPR-54,adding Operating Requirements Designed to Provide Proper Limitations & Conditions on Reactor Bldg Pressure Equalization Operations During Power Operation.Fee Paid1988-06-21021 June 1988 Application for Proposed Amend 130 to License DPR-54,adding Operating Requirements Designed to Provide Proper Limitations & Conditions on Reactor Bldg Pressure Equalization Operations During Power Operation.Fee Paid ML20155K0611988-06-14014 June 1988 Rev 0,Suppl 2 to Proposed Amend 159 to License DPR-54,making Minor Corrections to Tech Spec Table 3.5.5-1, Accident Monitoring Instrumentation,Items 5 & 14, & Table 4.1-1, Items 65 & 92 & Adding Second Note to Table 4.1-1,Item 80 ML20195J4561988-06-10010 June 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 67,reducing Count Time Required for prebatch- Release Sample Analysis.Ser & NSHC Analysis Encl.Fee Paid ML20150D1791988-03-17017 March 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 166,modifying Tech Specs to Correct Typos & Make Further Editorial Changes to Those Submitted in Proposed Amend 139.Fee Paid ML20196G5001988-03-0101 March 1988 Application for Amend to License DPR-54,consisting of Suppl 6 to Rev 0 to Amend 164,revising Tech Spec 4.1-1,Item 44.c & Tech Spec 4.10.1.E.2 to State Total Quantity of Gaseous Chlorine in Restricted Area ML20149K8521988-02-12012 February 1988 Suppl 4 to Rev 2 of Proposed Amend 138 to License DPR-54, Revising Tech Spec 6.5.1.6.d to Identify What Items Do Not Require Plant Review Committee Review ML20196D9001988-02-11011 February 1988 Suppl 1 to Rev 2 to Application for Amend 155 to License DPR-54,adding Term Dewatering to Process Control Program. Description of Changes Encl ML20149G1611988-02-0808 February 1988 Application for Amend to License DPR-54,consisting of Rev 0, Suppl 4 to Proposed Amend 164,adding Note to Tech Spec 3.3 to Eliminate Conflict W/Tech Spec 3.2.2.2 ML20196B7981988-02-0101 February 1988 Application for Proposed Amend 138 to License DPR-54.Amend Revises Nuclear Organization Chart,Figure 6.2-2 as Listed ML20148J3461988-01-13013 January 1988 Application to Amend License DPR-54,consisting of Proposed Amend 165,changing Tech Specs to Add Ventilation Radiation Monitor to Interim Onsite Storage Bldg.Fee Paid ML20149E5881988-01-0606 January 1988 Supplemental Application for Amend to License DPR-54, Consolidating Applicability Requirement for Containment Integrity in Tech Spec 3.6 Applicability Statement ML20149E1521987-12-23023 December 1987 Application for Amend to License DPR-54,consisting of Proposed Amend 159 Incorporating Accident Monitoring Instrumentation Recently Installed or Upgraded,Per Rev 3 to Reg Guide 1.97.Supersedes Amends 131 & 132.Fee Paid ML20149E8521987-12-23023 December 1987 Supplemental Application for Amend to License DPR-54, Consisting of Rev 2 to Proposed Amend 155,establishing New Set of Lower Limits of Detection for Prebatch Release & Composite post-release Analyses ML20236W8581987-12-0303 December 1987 Application for Amend to License DPR-54,consisting of Rev 0, Suppl 2 to Proposed Amend 164,combining Tech Specs 3.3.1.E & 3.3.1.F for Nuclear Svc Cooling & Raw Water.Revised Tech Spec Page 3-21 Encl ML20236U3241987-11-25025 November 1987 Suppl 1 to 860922 Application for Amend to License DPR-54, Consisting of Proposed Amend 145,adding Wording to Tech Spec Page 1-2b Re Surveillance of Internal Vent Valves to Cycle 8 Refueling Outage ML20236U0681987-11-25025 November 1987 Suppl 1 to Rev 0 to 871001 Application for Amend to License DPR-54,consisting of Proposed Amend 164.Attachment 1 Consists of Response to NRC Questions & Comments on Subj Proposed Amend & Util 871028 Responses to 34 Concerns ML20236V5821987-11-25025 November 1987 Application for Amend to License DPR-54,consisting of Suppl 2 to Rev 2 to Proposed Amend 138,changing Tech Spec Figures 6.2-1 & 6.2-2 to Assign Nuclear Security Manager & Staff Directly to Nuclear Power Production ML20236S0821987-11-17017 November 1987 Supplemental Application for Amend to License DPR-54, Consisting of Suppl 2 to Rev 2 to Proposed Amend 147, Concerning Diesel Generators ML20236P3411987-11-0606 November 1987 Supplemental Application for Rev 2 to Proposed Amend 152 to License DPR-54,revising Tech Specs Re Limiting Conditions for Operation of Instrumentation Sys ML20236K3761987-11-0202 November 1987 Application for Amend to License DPR-54,consisting of Proposed Amend 138,Rev 2,Suppl 1,adding non-licensed Personnel to Tech Spec Table 6.2-1,limited Representation to Tech Spec 6.5.2.5 & LERs to Tech Spec 6.5.2.6 ML20236D6451987-10-23023 October 1987 Application for Amend to License DPR-54,modifying Tech Specs to Provide Exception to Requirement That key-operated Shutdown Bypass Switch Not Be Used During Reactor Power Operation.Fee Paid ML20235R4051987-10-0303 October 1987 Rev 1 to Proposed Amend 155,revising Radiological Effluent Tech Specs to Incorporate Clarifications & Correct Editorial Errors ML20235Q4781987-10-0101 October 1987 Application for Proposed Amend 164 to License DPR-54, Consisting of Enhancements to Tech Specs to Resolve Certain Comments Resulting from NRC Region V Feb & Mar 1987 Contracted Comparison of Plant Tech Specs to Sts.Fee Paid ML20235F4521987-09-21021 September 1987 Application for Proposed Amend 162 to License DPR-54, Changing Tech Specs Re Concentration of Oxygen in Waste Gas Holdup Sys to Provide for When Sys Free of Potentially Explosive Gases,As for Example,During Maint.Fee Paid ML20195G4201987-09-16016 September 1987 Rev 2 to Proposed Amend 138,revising Tech Specs to Reflect Addl Organizational Changes Due to Need for Addl Mgt Staffing for Present Outage & from Expansion of long-term Mgt Function ML20236M3391987-07-31031 July 1987 Application for Amend to License DPR-54,consisting of Rev 2 to Proposed Amend 152,clarifying Proposed Limiting Conditions of Operation & Addl Surveillance Requirements for Emergency Feedwater Initiation & Control Sys ML20235F7541987-06-30030 June 1987 Application for Amend to License DPR-54,consisting of Amend 155,revising Tech Specs Re Radiological Effluents to Ensure Compliance W/Regulatory Requirements Concerning Effluent Monitoring & Nearby Land Use Identification.Fee Paid ML20235B8011987-06-29029 June 1987 Application for Amend to License DPR-54,revising Tech Specs to Modify Air Flow Rate Through Control Room Technical Support Ctr Essential Filtering Sys Per 10CFR50.91(b)(1).Fee Paid ML20235B6001987-06-29029 June 1987 Application for Amend 160 to License DPR-54,adding Tech Specs for Min Meteorological Instrumentation Required for Emergency Response Purposes Per Suppl 1 NUREG-0737 & Reg Guide 1.97.Fee Paid ML20214E2161987-05-14014 May 1987 Rev 1 to 860228 Application for Proposed Amend 111 to License DPR-54,reevaluating Effect of Containment Purging Coincident W/Loca Using TID Source Terms,Per NRC Request. Safety Analysis Also Encl ML20214D6371987-05-14014 May 1987 Application for Amend to License DPR-54,consisting of Proposed Amend 158,revising Tech Specs to Permit Operation of Combustible Gas Control Sys Using Two Proposed Thermal Hydrogen Recombiners.Fee Paid ML20209A7041987-04-23023 April 1987 Application for Amend to License DPR-54,revising Amend 82 Re Deficiency in Providing for Venting & Surveillance Testing of Low Temp Overpressure Protection Sys & Establishing Flow Rate for Nuclear Svc Electrical Bldg HVAC Unit.Fee Paid ML20206H1281987-04-0101 April 1987 Application for Amend to License DPR-54,revising &/Or Adding Addl Sections to Tech Specs & Addressing Safety Impact of Bringing Tdi Diesel Generators Into Svc. Description of Proposed Changes Encl 1996-10-14
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20211H7881999-08-13013 August 1999 Amend 126 to License DPR-54,changing Permanently Defueled TS (PDTS) D3/4.1, Spent Fuel Pool Level, to Replace Specific Reference to SFP (Sfp)Level Alarm Switches with Generic Ref to SFP Level Instrumentation ML20198G8211997-08-22022 August 1997 Amend 125 to License DPR-54,revising TS to Incorporate Revised 10CFR20, Stds for Protection Against Radiation & Amending Refs from NRC Region V to Region IV ML20129E3801996-10-14014 October 1996 Application for Amend to License DPR-54,representing Updated Licensing Basis for Operation of Shutdown Rancho Seco Nuclear Facility During Permanently Defueled Mode ML20058L4281993-12-0909 December 1993 Application for Proposed License Amend 187 to DPR-54 Re Changes Needed to Make PDTS Consistent W/New 10CFR20 Regulations.New 10CFR20 Effective 940101 ML20127N3291993-01-19019 January 1993 Application for Amend to License DPR-54,consisting of Proposed Amend 186,changing Organization & Requests Changes to Permanently Defueled Tech Specs Section D6.0 Administrative Controls Pages ML20059G9521990-09-10010 September 1990 Amend 115 to License DPR-54,revising License Condition Re Fire Protection Plan,Adding Administrative Controls to Tech Specs in Support of Fire Protection Plan & Relocating Fire Protection Requirements to Fire Protection Plan ML20247B6821989-07-19019 July 1989 Errata to Amends 109,110 & 111 to License DPR-54,correcting Omission of Language ML20247B3461989-07-17017 July 1989 Amend 112 to License DPR-54,revising Tech Specs to Increase Max Closure Time for Selected Containment Isolation Valves & Add 12 Valves to Table 3.6-1 ML20246F0991989-07-0505 July 1989 Application for Amend to License DPR-54,resubmitting Rev 1 to Proposed Amend 102,deleting Remaining Nonradiological Items Contained in App B of Tech Specs.Shutdown of Facility on 890607 Makes Submittal of Improved Specs Impractical ML20245E1101989-06-20020 June 1989 Amend 111 to License DPR-54,revising Section 2.C.(4) to Remove Requirements for Certain Fire Doors & Dampers ML20245A1901989-06-0909 June 1989 Amend 110 to License DPR-54,revising Tech Specs by Removing Tabular Listing of Snubbers as Suggested by Generic Ltr 84-13 ML20248B6171989-06-0505 June 1989 Amend 108 to License DPR-54,modifying Paragraph 2.C.(3) of License to Require Compliance W/Amended Physical Security Plan ML20248B9311989-06-0505 June 1989 Amend 107 to License DPR-54,removing Requirements for Fire Suppression Sys in Fire Zones 75-80 from Tech Spec 3.14 ML20248B9531989-06-0505 June 1989 Amend 109 to License DPR-54,revising Tech Spec 4.17 Steam Generators & Associated Bases & Tables 4.17-2A & 4.17-2B to Permit Repairs of Steam Generator Tubes by Means of Tube Sleeves ML20247K7121989-05-23023 May 1989 Amend 105 to License DPR-54,clarifying Operational Mode of Applicability of Tech Spec 3.4 & Definition of Auxiliary Feedwater Train & Revising Surveillance Requirements & Frequency of Verifying Auxiliary Feedwater Sys Flow Path ML20247M9071989-05-23023 May 1989 Amend 106 to License DPR-54,revising Tech Spec 4.17, Steam Generators, to Provide for More Extensive Insp of Steam Generator Tubes by Defining Special Tube Areas to Complete 100% Insp Where Degradation Expected ML20247K6811989-05-16016 May 1989 Amend 104 to License DPR-54,deleting Tech Specs Re Reactor Vessel Matl Surveillance ML20245F8931989-04-18018 April 1989 Amend 103 to License DPR-54,revising Tech Specs by Changing Air Flow Rate Through Reactor Bldg Purge Valves,Adding Requirement to Test Reactor Bldg Purge Exhaust HEPA Filters ML20248E9221989-03-29029 March 1989 Amend 102 to License DPR-54,changing Tech Specs to Permit one-time Extension for Certain Local Leak Rate Tests to Cycle 8 Refueling Outage & Revising Surveillance Period for Local Leak Rate Tests on DHR Suction Piping ML20235Y6011989-03-0606 March 1989 Application for Amend to License DPR-54,consisting of Suppl 1 to Proposed Amend 175,Rev 0,for one-time Extension for Certain Surveillances Required by Tech Specs to Be Performed Beginning 890329 ML20245H8851989-02-28028 February 1989 Rev 1 to Proposed Amend 130 to License DPR-54,adding Operating Requirements to Tech Specs Designed to Provide Proper Limitations & Conditions on Reactor Bldg Pressure Equalization Operations During Power Operation ML20195F7641988-11-18018 November 1988 Rev 1 to 881007 Proposed Amend 170,defining Applicability Requirements of Tech Spec 3.4 W/Respect to Auxiliary Feedwater Sys Flow Paths.Rev Deletes Words to the Condenser from Spec 4.8.1 ML20206F2811988-11-15015 November 1988 Suppl 1 to 880930 Application for Amend 166,Rev 1 to License DPR-54 Revising Tech Spec 4.6.4.f to Ensure Equipment Required to Verify Vital 120 Volt Ac Bus Operability ML20205R8631988-11-0404 November 1988 Application for Amend to License DPR-54,consisting of Rev 1 to Proposed Amend 172,withdrawing Request to Delete Reactor Bldg Spray Line Requirements & Justifying Removal of DHR Inlet Lines ML20205M8881988-10-28028 October 1988 Application for Amend 169 to License DPR-54,modifying Nuclear Svc Battery Surveillance Requirements.Fee Paid ML20205L2611988-10-25025 October 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 173,modifying Tech Spec 3.14 to Remove Requirements for Fire Suppression Sys in Fire Zones 75-80. Fee Paid ML20155G2161988-10-0707 October 1988 Application for Amend to License DPR-54,clarifying Operational Mode Applicability of Tech Spec 3.4 & Definition of Auxiliary Feedwater Sys Train.Fee Paid ML20155B8111988-09-30030 September 1988 Application for Rev 1 to Amend 166 to License DPR-54, Revising Tech Specs Re Reactor Protection Sys Trip Setting Limits by Making Editorial Corrections & Technical Changes ML20155B4251988-09-30030 September 1988 Application for Amend to License DPR-54,making Editorial Corrections & Administrative Changes.Fee Paid ML20155D3051988-09-28028 September 1988 Amend 100 to License DPR-54,deleting Organizational Charts from Tech Spec Administrative Section ML20154J5521988-09-19019 September 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 172,changing Local Leak Rate Test Requirements for Containment Penetrations.Fee Paid ML20154D7531988-09-0808 September 1988 Application for Amend to License DPR-54,consisting of Rev 1 to Amend 168,replacing Organization Charts W/More General Administrative Controls CEO-88-024, Supplemental Application for Amend to License DPR-54, Consisting of Rev 1 to Proposed Amend 102,deleting App B of Tech Specs1988-07-27027 July 1988 Supplemental Application for Amend to License DPR-54, Consisting of Rev 1 to Proposed Amend 102,deleting App B of Tech Specs ML20151L5331988-07-14014 July 1988 Redistributed Amend 99 to License DPR-54,adding Limiting Conditions of Operation & Surveillance Requirements Re Shunt Trip Attachment Installed at Facility in Response to Generic Ltr 83-28 CEO-88-002, Application for Proposed Amend 130 to License DPR-54,adding Operating Requirements Designed to Provide Proper Limitations & Conditions on Reactor Bldg Pressure Equalization Operations During Power Operation.Fee Paid1988-06-21021 June 1988 Application for Proposed Amend 130 to License DPR-54,adding Operating Requirements Designed to Provide Proper Limitations & Conditions on Reactor Bldg Pressure Equalization Operations During Power Operation.Fee Paid ML20155K0611988-06-14014 June 1988 Rev 0,Suppl 2 to Proposed Amend 159 to License DPR-54,making Minor Corrections to Tech Spec Table 3.5.5-1, Accident Monitoring Instrumentation,Items 5 & 14, & Table 4.1-1, Items 65 & 92 & Adding Second Note to Table 4.1-1,Item 80 ML20195J4561988-06-10010 June 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 67,reducing Count Time Required for prebatch- Release Sample Analysis.Ser & NSHC Analysis Encl.Fee Paid ML20151B3231988-03-30030 March 1988 Errata to Amends 97 & 98 to License DPR-54,correcting Inadvertent Errors in Tech Specs ML20148J8461988-03-17017 March 1988 Amend 98 to License DPR-54,revising Tech Specs by Reducing Limits of Detection for Liquid Radioactive Effluents & Changing Requirements to Address Hardware Changes in Effluent Sys ML20150D1791988-03-17017 March 1988 Application for Amend to License DPR-54,consisting of Proposed Amend 166,modifying Tech Specs to Correct Typos & Make Further Editorial Changes to Those Submitted in Proposed Amend 139.Fee Paid ML20153B2851988-03-15015 March 1988 Amend 97 to License DPR-54,modifying Various Sections of Tech Specs to More Closely Resemble B&W STS ML20196G5001988-03-0101 March 1988 Application for Amend to License DPR-54,consisting of Suppl 6 to Rev 0 to Amend 164,revising Tech Spec 4.1-1,Item 44.c & Tech Spec 4.10.1.E.2 to State Total Quantity of Gaseous Chlorine in Restricted Area ML20149M8541988-02-19019 February 1988 Amend 96 to License DPR-54,revising Administrative Controls Section of Tech Specs to Reflect Changes in Plant Mgt & Organization ML20149L6911988-02-12012 February 1988 Amend 95 to License DPR-54,revising Tech Specs to Reflect Hardware Mods Associated W/Reactor Bldg Combustible Gas Control.Hydrogen Purge Sys Replaced W/Incontainment Hydrogen Recombiner Sys ML20149K8521988-02-12012 February 1988 Suppl 4 to Rev 2 of Proposed Amend 138 to License DPR-54, Revising Tech Spec 6.5.1.6.d to Identify What Items Do Not Require Plant Review Committee Review ML20196D9001988-02-11011 February 1988 Suppl 1 to Rev 2 to Application for Amend 155 to License DPR-54,adding Term Dewatering to Process Control Program. Description of Changes Encl ML20149L2601988-02-0909 February 1988 Amend 94 to License DPR-54,adding Criteria to Tech Specs to Reflect Addition of Two Diesel Generators & Associated Mods to Facility Emergency Electrical Distribution Sys ML20149G1611988-02-0808 February 1988 Application for Amend to License DPR-54,consisting of Rev 0, Suppl 4 to Proposed Amend 164,adding Note to Tech Spec 3.3 to Eliminate Conflict W/Tech Spec 3.2.2.2 ML20196B7981988-02-0101 February 1988 Application for Proposed Amend 138 to License DPR-54.Amend Revises Nuclear Organization Chart,Figure 6.2-2 as Listed ML20148J3461988-01-13013 January 1988 Application to Amend License DPR-54,consisting of Proposed Amend 165,changing Tech Specs to Add Ventilation Radiation Monitor to Interim Onsite Storage Bldg.Fee Paid 1999-08-13
[Table view] |
Text
..
(SMU= SACRAMENTO MUNICIPAL UTILITY DISTRICT : ~ 6201 S Street. P.o. Box 15830. Sacramento CA 95852 1830,(916)452 3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA JEW 86-219 December 12, 1986 DIRECTOR OF NUCLEAR REACTOR REGULATION ATTENTION FRANK J MIRAGLIA DIRECTOR PWR-B DIVISION U S NUCLEAR REGULATORY COMMISSION WASHINGTON DC 20555 DOCKET N0. 50-312 LICENSE NO. DPR-54 PROPOSED AMENDMENT NO. 129 In accordance with 10 CFR 50.90, the Sacramento Municipal Utility District proposes to amend its Operating License DPR-54 for Rancho Seco Nuclear Generating Station Unit No. 1.
Proposed Amendment No. 129 provides clarification in Specification 4.11.1A and the Bases that the air flow rate through the Reactor Building Purge Valves is different with and without conditions of containment integrity.
This proposed amendment also adds Specification 4.11.D.2.(b) which through oversight, was not included in a previous amendment.
Details of this proposed amendment are presented in Attachments I, II and III which are the Safety Analysis, "No Significant Hazards" Evaluation and Description of Proposed Changes, respectively.
Pursuant to 10 CFR 50.91(b)(1), the Radiological Health Branch of the California State Department of Health Services has been informed of this proposed amendment by mailed copy of this submittal.
Enclosed is a check in the amount of $150.00 as required by 10 CFR 170.21,
" Schedule of Fees."
Should you require any further information with respect to this Proposed Amendment, please contact Mr. Ron Colombo at Rancho Seco Nuclear Gen-erating Station Unit No. 1.
/
( M WARD Subscribed and sworn to before me ASSISTANT GENERAL MANAGER this [ day of Decembc(, 1986 NUCLEAR Attachments cc: Region V (2) n (Utlvv1C IP (2) m OFFICIAL SEAL I DAWN DARUNG \g 8612160306 061212 12 PDR ADOCK 050 g{d f/in,iffiOTARyPUBUC
. sAcnavegoCAUFORNIA ceggy ,
I lk
,w P 'g .
g g
ATTAC E NT I SAFETY ANALYSIS Technical Specification 4.11.1A requires that the operational characteristics of the HEPA and charcoal filter banks associated with the Reactor Building Purge System be tested at least once 30 days prior to the start of fuel han-dling in the Reactor Building. Under the present specification, the air flow rate through the filter train is adjusted to maintain 66,700 CFM i 10% during containment integrity conditions with between 2 and 6 inches water gauge pressure drop across the combined HEPA and charcoal filter banks.
In response to the valve manufacturers recommendations (Allis-Chalmers Report A-C,VER0209,12/17/79), the Reactor Building Purge System inboard valves (SFV 53504 and SFV 53605) were modified to limit valve opening positions such that adequate closing torques would be maintained while limiting stresses below recommended operating levels. The inboard purge valves were modified to limit their strcke angle to .c 80* of their full open positions, and the outboard purge valves limited to g 60 of their full open positions.
As a result of these reduced valve stroke angles, the air flow rate of 66,700 cfm i 10% specified in 4.11.1A for flow through the HEPA filter and charcoal absorber train cannot be achieved with the required pressure drop across the combined filter banks. The flow rate of 60,000 cfm i 10% submitted in this proposed amendment has been proven achievable by actual test.
Systems, Subsystems, Components Affected Proposed Amendment No. 129 affects only the Reactor Building Purge Filtering System's ability to be properly tested per specification 4.11.1A. No modif-ications to the existing system, its components or any subsystems are being croposed under this amendment.
Safety Functions Of Affected Systems / Components When in operation, the purge system processes Reactor Building air through the filtration system prior to release to the atmosphere. The discharge is monitored and activates a radiation monitoring system alarm in the event of excessive radioactivity (USAR 9.7.2.1.3). In the event of a postulated Fuel Handling Accident within the Reactor Building during the refueling mode, the purge valves perform a containment isolation function actuating on high radi-ation signal. In the event of a LOCA, closure of the purge valves to isolate the containment is initiated upon SFAS signals (USAR 9.7.2.1.4). However, the purge valves are maintained closed except during cold shutdown and refueling conditions per Technical Specification 3.6.7.
Effects on Safety Functions Surveillance Specification 4.11.1A along with other Section 4.11 specifica-tions demonstrate the required operability of the Reactor Building Purge Filtration system. The use of this system is restricted to the cold shutdown and refueling modes per Technical Specification 3.6.7, consistent with SRP 6.2.4 and BTP CSB 6-4. For the postulated LOCA, the system would not be in operation, with the inboard and outboard purge valves already in a closed
, IC0ft' T. . .
position prior to the LOCA. The proposed decreased filtration air flow rate (66,700 CFM i 10% to 60,000 CFM i 10%) would have no effect on the USAR ana-lysis for the LOCA.
For the postulated Fuel Handling Accident within the Reactor Building, the radiation monitoring system high radiation signal would initiate the closure of the purge valves. With the lower proposed 60,000 CFM i 10% air flow rate prior to the valve closure, residence time within the HEPA and charcoal fil-tration cycle would be longer, therefore potentially reducing radiation levels released to the atmosphere prior to complete isolation.
Analysis of Effects on Safety Functions The proposed reduction for the purge system flow rate specification during surveillance testing has no effect on the isolation function (closure times) of the inboard and outboard purge valves. The valves continue to close within the specified times, consistent with the assumptions of the Chapter 14 Analyses. Due to the reduction of the air flow rate through the systen,, re-sidence time in the filtration cycle is longer, therefore potentially reduc-ing radiation releases to the atmosphere. There are no new failure modes being introduced as a result of the change.
Sunmary The proposed technical specification change affects only the adjustment of the air flow rate of the filtration system during the required surveillance testing. The fil'fation system's ability to process reactor building air is not degraded, nor is the containment isolation function of the purge valves affected by the reduction of flow. The proposed change allows the required surveillance test to be performed, consistent with the capability of the system. Implementation of the proposed amendment to Specification 4.11.1A does not constitute an unreviewed safety question.
On the basis of the above safety analysis, the District concludes that the proposed amendment will have no adverse effect on the safety of the plant, nor will the safety and health of the public be endangered.
i
ATTACl#ENT II
. "N0 SIGNIFICANT HA7.ARDS" EVALUATION
.Pr'oposed Amendment No. 129 consists of two adainistrative changes being made to Specification 4.11.1 of the Rancho Seco Technical Specifications.
The first change introduces a second flow rate (of 60,000 cfm i10%) to the 66,700 cfm i10% presently shown in Specification 4.11.1 that is exhausted from the Reactor Building Purge Valves. The two values represent the flow rate for the two conditions of 1) containment integrity, and 2) without con-tainment integrity. Calculations have confirmed that at either purge flow .
rate, the FSAR analysis for a loss of coolant accident (LOCA) remains valid.
Therefore, this proposed change is considered purely administrative.
lhe second change adds Specification 4.11.10.2.(b) which is identical to Specifications 4.10.1C.2.(b) and 4.12.20.2.(b) but which through oversight was not included in a previous amendment. This change also, is considered purely administrative.
The District has reviewea the proposed changos against each of the criterion of 10 CFR 50.92 and concluded that the clarification made to Specification 4.11.1A and the addition of Specification 4.11.10.2(b) plant operation would not:
- a. involve a significant increase in the probability or consequences of an accident previously evaluated. As stated above, calculations with respect
. to the first change have confirmed that neither the existing nor the proposed exhaust flow rates from the Reactor Building Purge Valves will invalidate the FSAR analysis for a loss of coolant accident. The pro-posed change is judged to be purely administrative, providing clarifica-tion to the Technical Specifications. _
The second change, adding Specification 4.11.10.2.(b), corrects a previous oversight of omission, and is judged also as purely administrative.
As administrative changes, neither of the two proposed are seen as in-volving a significant increase in the probability or consequences of an accident previously evaluated.
- b. create the possibility of a new or different kind of accident from any previcusly analyzed. Neither of the proposed changes introduce new plant designs or affect plant operations._ Therefore, the creation by these
- proposed administrative changes of a new or different accident from any l
previously analyzed is not foreseen.
- c. involve a significant reduction in a margin of safety. As stated in b.)
above, neither of the proposed changes affect plant design or operations.
Consequently, safety margins are not seen as being involved.
Based on the above considerations, the District has concluded that the proposed administrative changes do not constitute a "significant hazard", and that the health and safety of the public will not be endangered by the proposed additions to the Technical Specifications.
ATTAC K NT III DESCRIPTION OF PROPOSED CHANGES
, 1. Specification 4.11.1A., page 4-42: Moved item 1. into Specification 4.ll.1A, changing the air flow rate from 66,700 cpm 110% to 60,000 cfm 110% with clarification that the proposed value is applicable during conditions of containment integrity.
- 2. Specification 4.11.10.2(b), page 4-42b: Added in entirety.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . . _