Suppl 1 to 880930 Application for Amend 166,Rev 1 to License DPR-54 Revising Tech Spec 4.6.4.f to Ensure Equipment Required to Verify Vital 120 Volt Ac Bus Operability
ML20206F281
Person / Time
Site: Rancho Seco
Issue date: 11/15/1988
From: Dewitt R
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Knighton G
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20206F285 List:
References
AGM-NPP-88-567, NUDOCS 8811210078
Download: ML20206F281 (2)


Text

  • *
  • kSMUDSACRAMENTO MUNICIPAL UTIUTY DISTRICT C P. O. Box 15830, Sacramento CA 95852 1830,1916) 452-3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA AGM/NPP 88-567 NOV 15 1988 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Hashington, DC 20555 Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. DPR-54 PROPOSED AMENDHENT NO. 166, REVISION 1, SUPPLEMENT I Attention: George Knighton Based on further review, the District hereby supplements its September 30, 1988 submittal of Proposed Amendment No. 166, Revision 1 (PA 166, Rev. 1).

Attached is revised Technical Snecification 4.6.4.f (page 4-341). This Specification is modified to eeJre the equipment required to verify vital 120 volt AC bus operability is surveilled. The equipment specified in proposed Technical Specifications 3.7.2.H and 3.7.2.1 is directly related to Technical Specification surveillance requirement 4.6.4.f. The wording in Specification 4.6.4.f is modified and equipment is added to ensure the surveillance clearly states the appropriate requirements which verify vital 120 volt AC bus operability.

The Safety Analysis and No Significant Hazards Consideration for the District's September 30, 1988 submittal of PA 166, Rev. I remain valid for this supplement.

Pursuant to 10 CFR 50.91(b)(1), the Radiological Health Branch of the California State Department of Health Services has been informed of this proposed amendment supplement by mailed copy of this submittal.

Since this submittal is a supplement to PA 166, Rev. 1, no additional license fees are required.

Members of your staff with questions requiring additional information or clarification may contact Mr. Richard Hannheimer at (209) 333-2935, extension 4916.

8911210078 081115 0gf PDR ADOCK 05000312 P PDC RANCHO SECO NUCtEAR GENERATINo STATION D 1444o Twin Cities Road, Herald, CA 95638 9799;(209) 333 2935

o . <

,4 . .

George Knighton AGM/NPP 88-567 State of California SS County of Sacramento Russell B. DeWitt, being first duly sworn, deposes ar.d says: that he is Acting Assistant General Manager, Nuclear Power Production of Sacramento Municipal Utility District (SMUD), the licensee herein; that he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute this document on behalf of said licensee, du1Y Russell B. DeWitt W

Acting Assistant General Manager Nuclear Power Production L i Subscribed and affirmed to before me on this /8 (day of NMb,1988.

.e gggg^

I d

ESTHER H. HUGHES

.M. .'.. , NoTARYPUBUCa C AL5oRNfA ggM.k 9 Nf '

gjh, SACRAMENTO CoONTY Esther H. Hughes (/

j u, c.= 9pm oo 21,1959 Notary Public cc w/atch: A. D'Argelo, NRC, Rancho Seco G. Kalman, NRC, Rockville J. B. Hartin, NRC, Halnut Creek J. S. McGurk, State of California HIPC (2) l I

k b

-