Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML20135B5752 December 1996Notice of Violation from Insp on 960922-1102.Violation Noted:Listed Instances Where Written Procedures Not Properly Implemented
ML20135H78212 September 1985Exam Rept 50-458/OL-85-03 on 850729.Exam Results:Two of Five Reactor Operator Candidates & 9 of 12 Senior Reactor Operator Candidates Passed ExamsReactor Vessel Water Level
Half scram
Slow transfer
Overtravel
ML20136E48830 December 1985Insp Rept 50-458/85-67 on 850923.Violations Noted:Failure to Provide Proper Escort,Failure to Control Badge/Key Cards & Failure to Make Timely Notification.Details Withheld (Ref 10CFR73.21)
ML20136G5015 November 1985Notice of Violation from Insp on 851007-11
ML20136G5051 November 1985Insp Rept 50-458/85-71 on 851007-11.Violation Noted: Procedures STP-051-4228 & STP-051-4201 Permitted Trip Setpoint to Be Calibr Outside Tech Spec Limits
ML20136H1491 August 1985Notice of Violation from Insp on 850311-0517
ML20137A25314 November 1985Notice of Violation from Insp on 850930-1004
ML20137A27913 November 1985Insp Rept 50-458/85-66 on 850930-1004.Violations Noted: Failure to Update Procedures After Issuance of Temporary Change Notices & Issuance of Temporary Change Notice After Final ApprovalHydrostatic
ML20137H9478 January 1986Insp Rept 50-458/85-75 on 851022-25.Violation Noted: Inadequate Key Control.Insp Details Withheld (Ref 10CFR73.21)
ML20137J6251 April 1997Insp Rept 50-458/97-01 on 970127-0214.No Violations Noted. Major Areas Inspected:Operations & EngineeringReactor Vessel Water Level
Half scram
Squib
Job Performance Measure
Scram Discharge Volume
Operability Determination
Fire Watch
Grace period
Power change
Unidentified leakage
ML20137T29519 November 1985Insp Rept 50-458/85-69 on 850916-1031.Violation Noted: Improper Use of Field Change Notices & Failure of Document Control ProgramFire Barrier
ML20137T49211 April 1997Notice of Violation from Insp on 970202-0315.Violation Noted:As of 970315,administrative Procedures Not Developed in Sufficient Scope to Implement Requirements of TS 5.2.2.eMissed surveillance
ML20137T51411 April 1997Insp Rept 50-458/97-06 on 970202-0315.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering, Plant Support & Plant StatusHigh Radiation Area
Past operability
Enforcement Discretion
Locked High Radiation Area
Missed surveillance
Systematic Assessment of Licensee Performance
Hourly Fire Watch
ML20137W84130 September 1985Notice of Violation from Insp on 850616-0815
ML20137W89318 September 1985Insp Rept 50-458/85-51 on 850616-0815.Violation Noted: Attachments 1 & 2 for Electrical & Control Board Lineups Not Completed.Deviation Noted:Preoperational Test Procedure 1-PT-210 Did Not Demonstrate RHR Sys Will Inject to VesselStroke time
Nondestructive Examination
ML20138G33721 October 1985Notice of Violation from Insp on 850819-23
ML20140B0527 March 1986Notice of Violation from Insp on 860101-31
ML20140B07020 February 1986Insp Rept 50-458/86-04 on 860101-31.Violation Noted:Failure to Administratively Control Temporary Circuit Alterations & Failure to Schedule Supplemental Audit/Surveillance
ML20140D77029 January 1986Notice of Violation from Insp on 850311-0810
ML20140E27029 January 1986Notice of Violation from Insp on 851201-31
ML20140E28529 January 1986Notice of Deviation from Insp on 851201-31
ML20140E29822 January 1986Insp Rept 50-458/85-81 on 851201-31.Violations Noted:Failure of Document Control Program & Inadequate Retest Following Mods or Repair.Deviation Noted:Failure to Verify Proper Diesel Generator Load Sequencing
ML20140E90118 March 1986Notice of Violation from Insp on 860127-31
ML20140E9146 March 1986Insp Rept 50-458/86-05 on 860127-31.Violation Noted:Failure to Maintain Calibr Records of Gas Chromatograph While Performing Tech Spec Required Surveillance
ML20140H69927 March 1986Insp Rept 50-458/86-14 on 860317-20.Violations Noted: Inadequate Corrective Action,Failure to Perform Maint Per Procedures & Inoperable Div II Diesel GeneratorCoast down
ML20141C2741 April 1986Notice of Violation from Insp on 860127-31Offsite Dose Calculation Manual
ML20141C2861 April 1986Notice of Deviation from Insp on 860127-31
ML20141C3304 March 1986Insp Rept 50-458/86-01 on 860127-31.Violation Noted:High & Low Level Alarms on RMS-RE-126 Were Factor of Two Higher than Values Derived Using Offsite Dose Calculation Manual. Deviation Noted:Failure to Maintain Equipment Per FSARHigh Radiation Area
Offsite Dose Calculation Manual
ML20141E32326 June 1997Notice of Violation from Insp on 970427-0607.Violation Noted:Licensee Failed to Follow Procedure EIP-2-001,in That Licensee Entered TS Limiting Condition for Operation 3.4.5 Upon Determination & Did Not Declare Unusual EventPressure Boundary Leakage
Fire Protection Program
Fire Watch
Hourly Fire Watch
ML20141G57419 May 1997Notice of Violation from Insp on 970316-0426.Violation Noted:Three Examples Identified Where Procedures Were Not Adequately Maintained,Procedures Did Not Require Independent Verification of Activities Prescribed in ANSI 18.7-1976Temporary Modification
ML20147J1823 March 1988Notice of Violation from Insp on 871101-21.Violation Noted: One of Two Channels in One Trip Sys for RPS Initiation & Two of Four Channels for HPCS Initiation Were Inoperable When Instrument Root Valve 1RCS-V122 Closed
ML20148G36315 March 1988Insp Rept 50-458/88-07 on 880222-25.Deficiencies Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise
ML20149D3454 February 1988Notice of Violation from Insp on 871207-10 & 20-23.Violation Noted:Procedures & Emergency Training Deemed Ineffective Due to Listed Weaknesses Being Exhibited During Training Class Sessions
ML20149D3943 February 1988Insp Rept 50-458/87-30 on 871207-10 & 20-23.Violation Noted. Major Areas Inspected:Licensee Notifications,Communications & Emergency Preparedness Training Program
ML20149F5548 August 1994Notice of Violation from Insp on Stated Date.Violation Noted:Maint Work Order E568208 Did Not Include Step for Installation of Jumper to Prevent Interruption of Power Supply Neutral Circuit
ML20149F5705 August 1994Insp Rept 50-458/94-15 on Stated Date.Violations Noted. Major Areas Inspected:Onsite Response to Events,Operational Safety Verification,Maint & Surveillance Observations, Followup Maint & Review of LERReactor Vessel Water Level
High Radiation Area
Half scram
Stroke time
Deep Dose Equivalent
Power-Operated Valves
ML20149H14121 July 1997Partially Withheld Notice of Violation from Insp on 970623-27.Violation Noted:On 970626,inspector Identified That Video Capture Sys Did Not Have Capability of Generating Audible Alarm
ML20149H14421 July 1997Partially Withheld Insp Rept 50-458/97-11 on 970623-27.Major Areas Inspected:Specific Areas of Physical Security Program Including Review of Records & Repts,Testing & Maint,Vital Area Barriers & Detection Aids & Alarm Stations
ML20150B4939 March 1988Notice of Violation from Insp on 880101-0215.Violation Noted:On 880121,specified Corrective Action Had Not Been Completed for Nonconforming Condition Identified by Licensee on 860412
ML20150B5054 March 1988Insp Rept 50-458/88-01 on 880101-0215.Violation Noted.Major Areas Inspected:Nrc Bulletin 87-002,10CFR21 Repts, Surveillance Test Observation,Maint Observation,Safety Sys Walkdown & Operational Safety VerificationScram Discharge Volume
ML20151G09515 July 1988Notice of Violation from Insp on 880501-0630.Violation noted:at-the-controls Operator Not Cognizant as to Why Annunciator P863-75A-CO2, Fuel Bldg Supply Air Low Flow, Was Lit
ML20151G09715 July 1988Insp Rept 50-458/88-13 on 880501-0630.Violation Noted.Major Areas Inspected:Previous Insp Findings,Nrc Bulletins 88-001 & 88-007,NRC Info Notices,Surveillance Test Observation, Maint Observation & Safety Sys WalkdownSquib
Liquid penetrant
Inadvertent Siren Activation
ML20151N05318 December 1985Notice of Violation from Insp on 851021-25
ML20151N07911 December 1985Insp Rept 50-458/85-74 on 851021-25.Violation Noted:Failure to Have Required Records of Standby Liquid Control Sys Explosive Valves
ML20151N66230 December 1985Notice of Violation from Insp on 851028-1101
ML20151N66730 December 1985Notice of Deviation from Insp on 851028-1101
ML20151N6713 December 1985Insp Rept 50-458/85-73 on 851028-1101.Deviation Noted:Senior Radiation Protection Technicians Not Provided W/Proper Training.Violation Noted:Qualification Matrix for Technicians Not Updated for Period in Excess of 8 Months
ML20151R69019 April 1988Notice of Violation from Insp on 871102-06 & 1218.Violation Noted:Equipment Qualification File for T95 & 35 Tape Splices Used in Limitorque Smb/Sb Motor Operators Inside & Outside Containment,Did Not Adequately Support Qualification
ML20151R7165 April 1988Insp Rept 50-458/87-21 on 871102-26 & 1218.Violations Noted. Major Areas Inspected:Licensee Implementation of Program for Establishing & Maintaining Qualification of Electric Equipment within Scope of 10CFR50.49
ML20151X81618 August 1988Exam Rept 50-458/OL-88-01 on 880712-13.Exam Results:Two Candidates Passed All Portions of Exam & Have Been Issued Appropriate License.One Candidate Failed Exam