Notice of Violation from Insp on 871101-21.Violation Noted: One of Two Channels in One Trip Sys for RPS Initiation & Two of Four Channels for HPCS Initiation Were Inoperable When Instrument Root Valve 1RCS-V122 Closed
ML20147J182
Person / Time
Site: River Bend 
Issue date: 03/03/1988
From: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20147J163 List:
References
50-458-87-28, EA-87-229, NUDOCS 8803090200
Download: ML20147J182 (3)


Text

-

NOTICE OF VIOLATION Gulf States Utilities Docket No. 50-458 River Bend Station License No. NPF-47 EA 87-229 During an NRC inspection conducted on November 1-21, 1987, violations of NRC requirements were identified.

In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1987),theviolationsarelistedbelow:

A.

Technical Specifications Limiting Conditions for Operations (LCO) 3.3.1, 3.3.2, and 3.3.3 require that the following minimum channels of Drywell Pressure-High remain operable:

two channels per trip system for reactor protection system (RPS) initiation (operational conditions 1 and 2); two channels per trip system for primary and secondary containment and residualheatremoval(RHR)systemisolation(operationalconditions1}

2, and 3); and four channels for high pressure core spray system (HPCS initiation (operational conditions 1, 2, and 3). With less than the minimum number of channels operable, the associated LC0 action statement requirements include placing the inoperable channel (RPS or isolation actuation) and/or the trip system in the tripped condition within one hour and declaring the HPCS system inoperable.

Contrary to the above, from August 1985 to November 17, 1987 while the plant was operating in conditions 1, 2, or 3, one of two channels in one trip system for RPS initiation, primary and secondary containment isolation, and RHR system isolation were inoperable, and two of four channels for HPCS initiation were inoperable. The channels were inoperable when an instrument root valve (IRCS-V122) for a drywell pressure sensing line was closed, thereby isolating three pressure transmitters, and actions were not taken to meet the action statement requirements.

This is a Severity Level 111 violation (Supplement I).

B.

Technical Specification 6.8.1.d requires that written procedures shall be established, implemented and maintained for surveillance and test activities of safety-related equipment.

Step 7.7.4 of Temporary Procedure (TP) 87-25, "RPV Inservice Leakage Test," Revision 0, which provides instruction for the inservice leakage test on the reactor pressure vessel, requires that the operator secure shutdown cooling by stopping both RHR pumps and closing shutdown cooling isolation valves E12*F053A, E12*F053B, E12*F008 and E12*F009.

Contrary to the above, on November 19, 1987, step 7.7.4 of TP 87-25 was improperly signed off by the responsible shift supervisor due to confusion in the procedures, although the required valve manipulations for E12*F008 and E12*F009, described among other items in step 7.7.4, had not been performed.

This is a Severity Level IV violation (Supplement 1).

8803090200 080304 DR ADOCK 050 0

Notice of Violation C.

Technical Specification, 6.8.1.a requires that procedures shall be established, implemented, and maintained for activities recommended in Appendix A of Regulatory Guide 1.33, Revision 2, February 1978. Paragraph 9 of Appendix A to Regulatory Guide 1.33 delineates procedures for control of modification work.

Pursuant to Regulatory Guide 1.33, Procedure ENG-3-006, "River Bend Station Design and Modification Request Control Plan," requires that if a prompt modification request (PMR) cannot be cancelled (i.e. converted to a modification request or system returned to original configuration) by the date indicated in block 23, a memorandum explaining the need for an extension and the new cancellation date must be prepared, approved and forwarded to document control for permanent retention.

Contrary to the above, on November 17, 1987, it was found during a review of the PMR status log that extension memoranda had not been approved for 16 PMRs that were not cancelled by the due date. Examples include, PMR 86-98(dueSeptember 15, 1987); PMR 86-128 (due October 7, 1987) and PMR 87-35 (due October 23,1987).

This is a Severity Level IV Violation (Supplement 1).

Pursuant to the provisions of 10 CFR 2.201, Gulf States Utilities is hereby required to submit a written statement or explanation to the U.S. Nuclear Regulatory Comission, ATTN: Document Control Desk, Washington, D.C. 20555 with a copy to the Regional Administrator, Region IV, and a copy to the NRC Resident inspector, within 30 days of the date of the letter transmitting this Notice. This reply, should be clearly marked as a "Reply to a Notice of Violation" and should include for each violation:

(1) the reason for the violation if admitted, (2) the corrective steps that have been taken and the results achieved (3) the corrective steps that will be taken to avoid further violations,and(4)thedatewhenfullcompliancewillbeachieved, if an adequate reply is not received within the time specified in this Notice, an order may be issued to show cause why the license should not be modified, suspended, or revoked or why such other action as may be proper should not be taken. Where good cause is shown, consideration will be given to extending the response time.

FOR THE NUCLEAR REGULATORY COMMISSION

/

/

8{

Robert D. Martin Regional Administrator t Arlington, Texas, DatedgdayofMarch1988.

thisy

g p

1 1

P e

N.

+

Gulf States Utilities PAR 4 1988 DISTRIBUTION bec w/ enc 1:

i PDR l-SECY CA JMTaylor, DEDRO TMurley, NRR HThompson, HMSS JLieberman, OE LChandler, OGC Enforcement Officers RI, RII, RIII, RV HDenton, OGPA EJordan, AE00 SConnelly, DIA OE:ES File OE:EA File BSummers,OE(1trhd) tDCS RIV Distribution:

RMartin JCallan EHoller GMadsen JGilliland(ltrhd)

GSanborn DPowers RIV Files MIS Coordinator DChamberlain HScott k %..

en J,,_

?.

"l s A

  • M w/s,J w y R

N 0C D

R Wong RMartin LChandler JLieberman Taylor 2/ M 88 3// /86 2/M88 24y/88 i

y/88

/

L