Forwards First Interim Deficiency Rept Re Lack of Design Consideration for Thermal,Static & SSE Deflections in Variable & Rigid Spring Pipe Supports
ML19241A749
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 06/21/1979
From: Gilleland J
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19241A751 List:
References
NUDOCS 7907090351
Download: ML19241A749 (1)


Text

-

79035-03L/50-327 /,2 h] rY] p

'"W'jb-03L/50-328 TENNESSEE VALLEY AUTHORITY CH A TT ANOOG A. TENN ESSEE 374o1 500C Chestnut Street Tower II .]

June 21, 1979 ._

x _o

_

Mr. James P. O'Reilly, Director '. $

Office of Inspection and Enforce =ent g U.S. Nuclear Regulatory Co=ission m Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303 ,

,

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAP, PLGT UNITS 1 A!;D 2 - PIPE SUPPORT DESIGNERS DID NOT II, SOME CASES CONSIDER THE SUM OF DEFLECTIONS DUE TO THERMAL, STATIC, AND SAFE SHUTDOWN EARTHQUAKE - NCR SWP-79-S FIRST INTR 2 DrDaET The subject deficiency was initially reported to NRC-01E Inspector Bill Cottle on May 22, 1979, in accordance with 10 CFR 50.55(e).

Enclosed is our first interim report. We expect to sub=it our next report by Septe=ber 10, 1979.

If you have any questions concerning this matter, please get in toucn with D. L. La=bert at FTS 85!,-2581 .

Very truly yours, , ,

,

  • Y. k Il 1 J. E. Gilleland Assistant "anager of Power

.

Enclosure i cc: Mr. John C. Davis, Acting Director (Enclosure) e Office of Inspection and Enforcement U.S. Nuclear Regulatory Co=ission .,

(+k p 4 Washington, DC 20555 Q@ %s, . % @W7 4

-

(pl9 5/ 3 216

, 3'.S V a gg 8 6, g.

0 An Eause Ocoortumty Emonover

'790709C/I ;Oc l',qq dp