ML20215B326: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 15: Line 15:
| document type = OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING, TEXT-LICENSE APPLICATIONS & PERMITS
| document type = OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING, TEXT-LICENSE APPLICATIONS & PERMITS
| page count = 4
| page count = 4
| project =
| stage = Request
}}
}}



Latest revision as of 06:27, 7 October 2021

Application for Proposed Amend 132 to License DPR-54, Updating Tech Specs Re Primary & Backup Detectors Installed Per NUREG-0737,Item II.D.3 & Reg Guide 1.97 for Electromagnetically Operated Valve.Fee Paid
ML20215B326
Person / Time
Site: Rancho Seco
Issue date: 09/22/1986
From: Julie Ward
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Miraglia F
Office of Nuclear Reactor Regulation
Shared Package
ML20215B328 List:
References
RTR-NUREG-0737, RTR-NUREG-737, RTR-REGGD-01.097, RTR-REGGD-1.097, TASK-2.D.3, TASK-TM JEW-86-288, NUDOCS 8610060510
Download: ML20215B326 (4)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ . . _ - . _ _ _ . _

e >

esuun SACRAMENTO MUNICIPAL UTIUTY DISTRICT O 6201 S Street, P.O. Box 15830, Sacramento CA 95852-1830,(916) 452-3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA JEW 86-288 September 22, 1986 DIRECTOR OF NUCLEAR REACTOR REGULATION ATTENTION FRANK J MIRAGLIA DIRECTOR PWR-B DIVISION U S NUCLEAR REGULATORY COMMISSION WASHINGTON DC 20555 DOCKET NO. 50-312 LICENSE NO. DPR-54 PROPOSED AMENDMENT N0. 132 In accordance with 10 CFR 50.90, the Sacramento Municipal Utility District proposes to amend its Operating License DPR-54 for Rancho Seco Nuclear Gen-erating Station Unit No. 1.

Proposed Amendment No. 132 updates the Technical Specifications to show the primary and backup detectors installed per NUREG 0737/II.0-3 and Reg. Guide 1.97 requirements for the EMOV Pressurizer Relief Valve Position Indicators.

Additionally, a footnote with respect to the position indicators is reword-ed for clarification from: " Applicable EMOV is OPERABLE" to: " Applicable when EMOV is OPERABLE." These changes are discussed in detail in Attach-ments I, II and III which are the Description of Proposed Changes, Safety Analysis and No Significant Hazards Consideration, respectively.

Pursuant to 10 CFR 50.91(b)(1), the Radiological Health Branch of the Cal-ifornia State Department of Health Services has been informed of this pro-posed amendment by mailed copy of this submittal.

Enclosed is a check in the amount of $150.00 as required by 10 CFR 170.21,

" Schedule of Fees."

Should you require any further information with respect to this Proposed Amendment, please contact Mr. Ron W. Colombo at Rancho Seco Nuclear Gen-erating tation Unit N 1.

0 . WARD Subscribed and sworn to before me DEPUTY GENERAL MANAGER, on this 22. day of $ g , 1986 NUCLEAR l Attachments gn \

O '

Not'ary Public cc: Re on V (2)

Oh 8ll l MIPC (2)

  • ~ fy %.

N DAWN DARUNG p

8610060510 860922 PDR ADOCK 05000312  % %-

- NOTARYPUBUO SACRAMENTO COUNTY CAUFORNfAUI p PDR My coma E@es Jon 12,1990

- _ - _ _ _ _ _ - - )

. ATTAC K NT I DESCRIPTION OF PPOPOSED CHANGES

1. Table 3.5.1-1, Instruments Operating Conditions,~page 3-30: Under Process Instrumentation, changed Item 4 Functional Unit description from: "EMOV Position Indicator (Primary Detector) power indicator ***" to: "EMOV Pressurizer Relief Valve Position Indicator (Primary Detector - Acoustic Flow Monitor)***." Change the Total Number of Channels from: 1/ Valve to:

2, and the Minimum Channels Operable from: 1/ Valve to: 1. Also added Action statement: '"See Section 3.5.1.2."

2. Table 3.5.1-1, Instruments Operating Conditions, page 3-30: Under Process Instrumentation, changed Item 5 Functional Unit description from: "EMOV Position Indicator (Backup Detector) acoustic or T/C***" to: "EMOV Pressurizer Relief Valve Position Indicator (Backup Detector - Mechanical Indicator or T/C)***." Changed the Total Number of Channels Operable from:

1/ Valve to: 2, and the Minimum Channels Operable from: 0 to: 1. Also added Action statement: "See Section 3.5.1.2."

3. Table 3.5.1-1, Instruments Operating Conditions, page 3-30: Changed wording of Footnote *** from: " Applicable EMOV is OPERABLE" to: " Applicable when EMOV is OPERABLE."
4. Table 4.1-1, Instrument Surveillance Requirements, page 4-7b: Changed Channel Description for Item 52 from: "EMOV Power Position Indicator (Primary Detector)" to: "EMOV Pressurizer Relief Valve Acoustic (Primary Sensor) Flow Monitor."
5. Table 4.1-1, Instrument Surveillance Requirements, page 4-7b: Changed Channel Description for Item 53 from: EMOV Position Indicator (Backup Detector) T/C or Acoustic" to: EMOV Pressurizer Relief Valve T/C (Backup Sensor) Flow Monitor."

, ATTACl#ENT II SAFETY ANALYSIS Proposed Amendment No. 132. updates Table 3.5.1-1 (Process Instrumentation Items 4 & 5) and Table 4.1-1 (Items 52 & 53) to show the primary and backup detectors installed for EMOV Pressurizer Relief Valve position indication per NUREG 0737/

II.D-3 and Reg. Guide 1.97 requirements. The primary detectors are two acoustic flow monitors; tha backup detectors are one each mechanical indicator and tailpipe thermocouple. Additionally, it is proposed that the wording of the triple-asterisked footnote for Table 3.5.1-1 be changed for clarity from:

" Applicable EMOV is OPERABLE" to:

" Applicable when EMOV is OPERABLE."

The proposed changes to Tables 3.5.1-1 and 4.1-1 are being made-to reflect the installed upgrading of the EMOV Pressurizer Relief Valve position indication instrumentation meeting NUREG 0737/11.0-3 and Reg. Guide 1.97 requirements for category Type D variables. The acoustic flow monitors (primary detectors) and associated cabling have been upgraded to Class I in compliance with Reg. Guide 1.97.

With the exception.of the wording change in the triple-asterisked footnote for Table 3.5.1-1, the proposed changes are revisions made to reflect the actual EMOV Pressurizer Relief Valve position indication instruments as installed in compliance with federal regulations. All changes are judged to be purely administrative and are considered to have no involvement with or effect on plant safety.

~

. ATTACl#ENT III NO SIGNIFICANT HAZARDS CONSIDERATION Proposed Amendment No. 132 consists of changes to Tables 3.5.1-1 (Items 4 and 5) and 4.1-1 (Items 52 and 53) showing the EMOV Pressurizer Relief Valve leak detection instrumentation installed in compliance with NUREG 0737/II.D-3.

In addition, the wording of the triple-asterisked footnote to Table 3.5.1-1

~is changed from: " Applicable EMOV is OPERABLE" to: " Applicable when EMOV is OPERABLE" to make it clear that there is only one EMOV.

The District has reviewed the proposed changes against each of the criterion of 10 CFR 50.92 and concluded that plant operation with the above administrative changes to the Technical Specifications would not:

a. involve a significant increase in the. probability or consequences of an accident previously evaluated, or
b. create the possibility of a new or different kind of accident from any previously analyzed.

The proposed changes are purely administrative, consisting of updating two tables and clarifying a table footnote. These changes do not affect plant design or operation and thus are judged to have no accident

' potential.

c. involve a significant reduction in a margin of safety. As stated above, the proposed administrative changes have no. affect on plant design or operation. Therefore margins of safety are also judged uraffected.

On the basis of the above, the District concludes that the proposed changes, purely administrative, do not constitute any significant hazards, and in no way endanger the health and safety of the public.