{{#Wiki_filter:}}
{{#Wiki_filter:.-
JUL i 01986 Docket No. 70-1151 License No. SNM-1107 Westingh yase Electric Corporation ATTN: W r. E. P. Loch, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, SC 29250 Gentlemen:
 
==SUBJECT:==
NRC INSPECTION REPORT NO. 70-1151/86-10 This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by J. B. Kahle on June 16-20, 1986. The inspection included a review of activities authorized for your Columbia facility. At the conclusion of the inspection, the findings were discussed with those members of your staff identified in the enclosed inspection report.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel,_ and observation of activities in progress.
Within the scope of the inspection, no violations or deviations were identified.
In accordance with 10 CFR 2.790(a), a copy of this letter, its enclosure, and any reply will be placed in the NRC Public Document Room. If you wish to withhold information contained therein, please notify this office by telephone within ten days of the date of this letter and submit a written application to withhold information contained therein promptly thereafter.      Such application must be consistent with the requirement of 10 CFR 2.790(b)(1). If we do not hear from you in this regard within the period specified above, this letter, its enclosure, and any reply will be made available to the public and be placed in the NRC Public Document Room.
Should you have any questions concerning this letter, please contact us.
Sincerely, 8608110458 860710-PDR    ADOCK 07001151                  Kenneth P. Barr, Chief PDR -.              Nuclear Materials Safety and Safeguards Branch Division of Radiation Safety and Safeguards
 
==Enclosure:==
(See page 2)
I).5207
 
r.
Westinghouse Electric Corporation                                        2                                            JUL 10 986
 
==Enclosure:==
 
NRC Inspection Report c w/o enc 1:
icense Fee Management Branch cument Control Desk
* ate of South Carolina 4
i 4
}
l
~
RII                                  RII JB a 'Ye:er                          EJMc 1p ne 07/ 3 /86                            07/5/86                                                                                                              ,
    . . _ , - - .        . , . . _ . . . _ . . . . . - _ . . . . . _ . . . - _ . , _ ,-_.  . . . . . . . _ . _ _ _ . . _ . _ . . _ _ -          . _ , . - - _ . . _ _ ~ .}}

Latest revision as of 07:52, 30 December 2020

Forwards Insp Rept 70-1151/86-10 on 860616-20.No Violations or Deviations Noted
ML20205A833
Person / Time
Site: Westinghouse
Issue date: 07/10/1986
From: Barr K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Loch E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20205A839 List:
References
NUDOCS 8608110458
Download: ML20205A833 (2)


Text

.-

JUL i 01986 Docket No. 70-1151 License No. SNM-1107 Westingh yase Electric Corporation ATTN: W r. E. P. Loch, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, SC 29250 Gentlemen:

SUBJECT:

NRC INSPECTION REPORT NO. 70-1151/86-10 This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by J. B. Kahle on June 16-20, 1986. The inspection included a review of activities authorized for your Columbia facility. At the conclusion of the inspection, the findings were discussed with those members of your staff identified in the enclosed inspection report.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel,_ and observation of activities in progress.

Within the scope of the inspection, no violations or deviations were identified.

In accordance with 10 CFR 2.790(a), a copy of this letter, its enclosure, and any reply will be placed in the NRC Public Document Room. If you wish to withhold information contained therein, please notify this office by telephone within ten days of the date of this letter and submit a written application to withhold information contained therein promptly thereafter. Such application must be consistent with the requirement of 10 CFR 2.790(b)(1). If we do not hear from you in this regard within the period specified above, this letter, its enclosure, and any reply will be made available to the public and be placed in the NRC Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely, 8608110458 860710-PDR ADOCK 07001151 Kenneth P. Barr, Chief PDR -. Nuclear Materials Safety and Safeguards Branch Division of Radiation Safety and Safeguards

Enclosure:

(See page 2)

I).5207

r.

Westinghouse Electric Corporation 2 JUL 10 986

Enclosure:

NRC Inspection Report c w/o enc 1:

icense Fee Management Branch cument Control Desk