IR 05000302/2016001: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 73: | Line 73: | ||
No reply to this letter is required. Please contact Steve Hammann at 610-337-5399 if you have any questions regarding this matter. | No reply to this letter is required. Please contact Steve Hammann at 610-337-5399 if you have any questions regarding this matter. | ||
Sincerely,/RA/ | Sincerely, | ||
/RA/ | |||
Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety | Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety | ||
Enclosures: | |||
1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001 cc w/encl 1: Distribution via ListServ cc w/encl 2: | 1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001 cc w/encl 1: Distribution via ListServ cc w/encl 2: | ||
T. Hobbs, Decommissioning General Manager ____________________________________________________________________________ | T. Hobbs, Decommissioning General Manager ____________________________________________________________________________ | ||
Line 94: | Line 95: | ||
-337-5399 if you have any questions regarding this matter. | -337-5399 if you have any questions regarding this matter. | ||
Sincerely,/RA/ Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety | Sincerely, | ||
/RA/ Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Enclosures: | |||
1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001 cc w/encl 1: | 1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001 cc w/encl 1: | ||
Distribution via ListServ cc w/encl 2: | Distribution via ListServ cc w/encl 2: |
Revision as of 16:37, 10 May 2019
ML16123A103 | |
Person / Time | |
---|---|
Site: | Crystal River |
Issue date: | 05/02/2016 |
From: | Stephen Hammann NRC/RGN-I/DNMS/NMSB3 |
To: | Hobbs T Duke Energy Florida |
References | |
IR 2016001 | |
Download: ML16123A103 (9) | |
Text
Official Use Only
- Security-Related Information May 2, 2016
May 2, 2016
Docket No.
050003 0 2License No.
DPR-72 Terry Hobbs Decommissioning General Manager Duke Energy Florida, Inc.
Crystal River Nuclear Plant 15760 W. Power Line Road
Crystal River, FL 34428-6708
SUBJECT: NRC INSPECTION REPORT NO. 05000302/2016001, DUKE ENERGY FLORIDA, INC., CRYSTAL RIVER NUCLEAR PLANT, CRYSTAL RIVER, FLORIDA
Dear Mr. Hobbs:
On April 4, 2016, the U.S. Nuclear Regulatory Commission completed an inspection under Inspection Manual Chapter 2561, "Decommissioning Power Reactor Inspection Program," at the permanently shut down Crystal River Nuclear Plant Unit 3 (CR
-3). An on
-site inspection was performed on March 1
-3, 2016 and in
-office reviews of information supplied by Duke Energy Florida, Inc. were also performed. The inspection examined activities conducted under your license as they relate to safety, security, and compliance with the Commission's rules and regulations, and the conditions of your license. The inspection consisted of observations by the inspectors, interviews with personnel, and a review of procedures and records.
The results of the inspection were discussed with you and other members of the CR
-3 staff on April 4, 2016, and are described in the enclosed report. Based on the results of this inspection, the NRC has determined that one Severity Level (SL) IV violation of NRC requirements occurred. This violation is being treated as a Non-Cited Violation (NCV), consistent with Section 2.3.2 of the Enforcement Policy.
The NCV contains security related information and is documented in Enclosure 2 of the subject inspection report.
If you contest the violation or significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555
-0001, with copies to: (1) the Regional Administrator, Region I; (2) the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555
-0001; and (3) the NRC Senior Decommissioning Inspector, Region I.
Official Use Only
- Security-Related Information UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BOULEVARD, SUITE 100 KING OF PRUSSIA, PA 19406
-2713 Enclosure 2 contains Sensitive Unclassified Non
-Safeguards information. When separated from Enclosure 2, the document is decontrolled
. Official Use Only
- Security-Related Information Official Use Only
- Security-Related Information However, the material enclosed in Enclosure 2 contains security
-related information in accordance with 10 CFR 2.390(d)(1), and its disclosure to unauthorized individuals could present a security vulnerability.
Therefore, the material in Enclosure 2 will not be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's ADAMS.
If you choose to provide a response, and security
-related information is necessary to provide an acceptable response, please mark your entire response "Security
-Related Information
- Withhold from Public Disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1), and follow instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Current NRC regulations and guidance are included on the NRC's website at www.nrc.gov
- select Nuclear Materials; Med, Ind, & Academic Uses; then Regulations, Guidance and Communications. The current Enforcement Policy is included on the NRC's website at www.nrc.gov; select About NRC, Organizations & Functions; Office of Enforcement; Enforcement documents; then Enforcement Policy (Under 'Related Information'). You may also obtain these documents by contacting the Government Printing Office (GPO) toll
-free at 1-866-512-1800. The GPO is open from 8:00 a.m. to 5:30 p.m. EST, Monday through Friday (except Federal holidays).
No reply to this letter is required. Please contact Steve Hammann at 610-337-5399 if you have any questions regarding this matter.
Sincerely,
/RA/
Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety
Enclosures:
1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001 cc w/encl 1: Distribution via ListServ cc w/encl 2:
T. Hobbs, Decommissioning General Manager ____________________________________________________________________________
Official Use Only
- Security-Related Information Official Use Only
- Security-Related Information However, the material enclosed in Enclosure 2 contains security
-related information in accordance with 10 CFR 2.390(d)(1), and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in Enclosure 2 will not be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's ADAMS. If you choose to provide a response, and security-related information is necessary to provide an acceptable response, please mark your entire response "Security
-Related Information
- Withhold from Public Disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1), and follow instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Current NRC regulations and guidance are included on the NRC's website at www.nrc.gov
- select Nuclear Materials; Med, Ind, & Academic Uses; then Regulations, Guidance and Communications. The current Enforcement Policy is included on the NRC's website at www.nrc.gov; select About NRC, Organizations &
Functions; Office of Enforcement; Enforcement documents; then Enforcement Policy (Under 'Related Information'). You may also obtain these documents by contacting the Government Printing Office (GPO) toll
-free at 1-866-512-1800. The GPO is open from 8:00 a.m. to 5:30 p.m. EST, Monday through Friday (except Federal holidays).
No reply to this letter is required. Please contact Steve Hammann at 610
-337-5399 if you have any questions regarding this matter.
Sincerely,
/RA/ Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Enclosures:
1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001 cc w/encl 1:
Distribution via ListServ cc w/encl 2:
T. Hobbs, Decommissioning General Manager DOCUMENT NAME:
G:\WordDocs\Current\Insp Letter
\LDPR-72.2016001.doc SUNSI Review Complete:
SHammann ML16123A103 After declaring this document AAn Official Agency Record
@ it will be released to the Public.
To receive a copy of this document, indicate in the box:
A C@ = Copy w/o attach/encl A E@ = Copy w/ attach/encl A N@ = No copy OFFICE DNMS/RI N D RS/RI DNMS/RI NAME SHammann/sth RMcKinley /rm RPowell/rp DATE 4/25/16 4/25/16 5/2/16 OFFICIAL RECORD COPY Official Use Only
- Security-Related Information Enclosure 1 Official Use Only
- Security-Related Information U.S. NUCLEAR REGULATORY COMMISSION REGION I INSPECTION REPORT
Inspection No.
05000302/2016001 Docket No.
05000302 License No.
DPR-72 Licensee: Duke Energy Florida, Inc. (Duke Energy)
Facility: Crystal River Unit 3 (CR
-3) Location: 15760 W. Power Line Road Crystal River, FL 34428
-6708 Inspection Dates:
March 1-3, 2016 Inspectors:
Stephen Hammann, Senior Health Physicist Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Briana DeBoer, Health Physicist Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Approved By:
Raymond Powell, Chi ef Decommissioning and Technical Support Branch Division of Nuclear Materials Safety
Official Use Only
- Security-Related Information ii Enclosure 1 Official Use Only
- Security-Related Information
EXECUTIVE SUMMARY
Duke Energy
Crystal River Nuclear Plant NRC Inspection Report No. 05000302/2016001
An announced CR
-3 decommissioning inspection was completed on April 4, 2016. The inspectors performed an on-site inspection the week of March 1
-3, 2016. In-office reviews of information supplied by Duke Energy were also performed during the inspection. The inspection included a review of management oversight, organization and staffing, spent fuel pool (SFP) safety, and decommissioning performance. The inspection consisted of observations by the inspectors, interviews with Duke Energy personnel, a review of procedures and records, and plant walk-downs. The NRC's program for overseeing the safe operation of a shut-down nuclear power reactor is described in Inspection Manual Chapter (IMC) 2561, "Decommissioning Power Reactor Inspection Program."
Official Use Only- Security-Related Information
Official Use Only- Security-Related Informati on
REPORT DETAILS
1. Background On February 20, 2013, Duke Energy sent a letter [Agency Documentation and Management System (ADAMS) Accession Number: ML13056A005]
to the NRC certifying the permanent cessation of activities and certifying that the fuel had been permanently removed from the reactor. This met the requirements of 10 Code of Federal Regulations (CFR) 50.82(a)(1)(i) and 50.82(a)(1)(ii). Currently, CR
-3 is in the SAFSTOR phase of decommissioning as described in IMC 2561.
2. SAFSTOR Performance and Status Review
a. Inspection Scope
(Inspection Procedures (IPs) 36801, 60801, 71801)
The inspectors performed an on
-site inspection the week of March 1
-3, 2016. In
-office reviews of information supplied by Duke Energy were also performed during the inspection. The inspection consisted of observations by the inspectors, interviews with Duke Energy personnel, a review of procedures and records, and plant walk
-downs.
The inspectors conducted document reviews, performed observations, attended site meetings, and interviewed plant personnel to verify the following:
regulatory requirements were properly implemented with respect to the site organization, staffing and staff qualifications; certified fuel handler and employee training programs were implemented in accordance with Duke Energy procedures and NRC requirements; Duke Energy established procedures and processes to resolve employee safety concerns, disseminate safety information and effectively resolved identified problems; and Duke Energy's decommissioning activities were performed in a manner consistent with the Post Shutdown Decommissioning Activities Report (PSDAR).
The inspectors reviewed CR
-3's programs for the safe wet storage of spent fuel.
The inspectors performed a walk
-down of the SFP and associated support systems to assess material condition, configuration control, and system operation. The inspectors also accompanied chemistry technicians as they sampled and analyzed SFP water, and observed radiation protection technicians performing SFP cleaning activities in order to assess SFP chemistry and cleanliness controls. The inspectors interviewed employees and reviewed work orders, procedures, and water analysis to verify compliance with the technical specifications.
The inspector s observed CR
-3 and Areva, Inc. personnel performing holddown spring removals of spent fuel assemblies. The holddown spring removals
, along with fuel assembly grid repositioning
, are being done to prepare the fuel assemblies for the CR
-3 campaign to move all fuel assemblies from the spent fuel pool and into dry cask storage. The inspectors reviewed the procedures, work plans, radiation work permits, equipment setup, RP coverage of the project, and evaluated CR
-3's adherence to procedures.
Official Use Only
- Security-Related Information Official Use Only
- Security-Related Information
b. Observations and Findings
The inspectors verified that management oversight was adequate for the SAFSTOR phase of decommissioning and that no significant changes had been made to the CR
-3 SAFSTOR organization since the previous inspection. The inspectors determined that training programs were being appropriately implemented by the responsible section managers and reported up to the Decommissioning Manager. The inspectors attended a plant safety meeting and found potential safety hazards were being discussed with the staff.
The inspectors verified spent fuel pool chemistry and cleanliness controls were being adequately implemented.
The inspectors verified the chiller system installed after CR
-3 entered decommissioning to replace the existing SFP cooling system was functioning adequately. The inspectors determined tests had been adequately performed to assess the condition of the carborundum poison material in SFP A.
The inspectors noted that the work being performed on the fuel assemblies is to prepare for placing the fuel assemblies into the dry shielded canisters.
The inspectors noted that Areva personnel were performing the activities with oversight and support from CR
-3 personnel. The inspectors determined that the project to ensure fuel assemblies are acceptable for dry cask storage is on
-going and the next phase will include gauging suspect fuel assemblies to determine if they will fit into cells in the dry shielded canisters.
c. Conclusions
Based on the results of this inspection, no findings of safety significance were identified.
3. Exit Meeting On April 4, 2016, the inspectors presented the inspection results, via teleconference, to Terry Hobbs, Decommissioning General Manager, and other members of Duke Energy's staff. The inspectors confirmed that proprietary information was not removed from the site.
Official Use Only
- Security-Related Information Official Use Only
- Security-Related Information PARTIAL LIST OF PERSONS CONTACTED Licensee B. Akins, Radiation Protection and Chemistry Manager P. Dixon, Decommissioning Technical Support Manager C. Gavin, Nuclear Performance Specialist T. Hobbs, Decommissioning General Manager J. Lane, Systems Engineer P. Rose, Licensing I. Wilson, Operations and Maintenance Manager K. Shelton, RP Supervisor M. Van Sicklen, Licensing P. Worthington, Engineering Supervisor ITEMS OPEN, CLOSED, AND DISCUSSED None LIST OF
DOCUMENTS REVIEWED
Procedures
AI-1806, CR-3 Safety Committee, Rev. 25
AREVA FS-043, MK-B4 Holddown Spring Removal Procedure, Rev. 08
AREVA FS-097, Foreign Material Removal and Retrieval, Rev. 06
AREVA FS-285, Fuel Assembly Grid Positioning, Rev. 01
CH-400A, Nuclear Chemistry Data Sheets, Primary Water Chemistry and Countroom, Rev. 20
CH-513A, Spent Fuel Coolant Sampling (SFP), Rev. 4
CH-513C, Spent Fuel Coolant Filter 3A&3B/Demineralizer Outlet Sampling
(SFDM-1), Rev. 2
CH-572A, FST-1A Sampling, Rev. 3
CH-9000, Spent Fuel Pool Cooling Chilled Water System (ChhE
-4A/B) and Control Complex
Cooling Chilled Water System (CHHE
-4C) Sampling and Chemical Addition, Rev. 3
EHS-PGM-105, Environmental, Health and
Safety Event Reporting and Investigation Program, Rev. 0 FP-204, Auxiliary Building Fuel Handling Operations, Rev. 6
FP-601C, Operation of Spent Fuel Pool Handling Bridge FHCR
-3, Rev. 50
FP-601G, Operation of Spent Fuel Handling Monorail FHCR
-3A, Rev. 5 MNT-0007, Foreign Material Exclusion Program, Rev. 0
MNT-020, Cranes and Hoists, Rev. 0
MP-806, Mobile Crane Control, Rev. 14
OP-421C, Operation of the Auxilliary Building Overhead Crane FHCR
-5, Rev. 44
OP-421D, Operation of the Spent Fuel Pit Missile Shield Crane FHCR
-7, Rev. 26
SP-318, Spent Fuel Pool Boron Concentration Verification, Rev. 3
TAP-403, Conduct of Written Examinations, Rev. 23
TAP-404, Training Documentation and Records, Rev. 10
TAP-408, Development and Conduct of Job Performance Measures, Rev. 11
Official Use Only
- Security-Related Information
Enclosure
Official Use Only
- Security-Related Information
Procedures
(Contd) TAP-413, Conduct of Operator Continuing Training, Rev. 24
TPP-219, Emergency Response Organization Training Program, Rev 7
TPP-901, Certified
Fuel Handler Training and Retraining Program, Rev. 1
TRN-1000, Performance Based Training, Rev. 2
Completed Surveillance Procedures and Surveys
SFP water analysis, 10/06/15
- 3/1/2016 Water sample analysis 10
-Feb-2016-003 and 16
-Feb-2016-003 Miscellane
ous AR 01960787
CR-3 Grid Strip
-HDS-Debris Removal Site Schedule
CR-3 Safety Council Members, October 15, 2015
Maintenance CRC Meeting Minutes, 10
-06-15 Operations CRC Meeting Minutes, September 23, 2015
RWP #1061, Rev. 0
SAF-2176, Job Safety Analysis (JSA)
SAFSTOR CRC Meeting Minutes, September 9, 2015
Station Performance Oversight Committee (SPOC) Meeting Minutes, December 15, 2015
Team Safety
- Top Safety Concerns 2015, 11/09/2015
Work Orders
WO 01929241 01, High Density Rack Poison SAM
WO 20037898 01, Clean the A&B SFP & Cask Loading Area
WO 20037931 01, Spent Fuel Pool Boron Concentration Verification
WO 13535579, Sample Mold in Buildings & Analysis
LIST OF ACRONYMS USED
ADAMS Agency Documentation and Management System CFR Code of Federal Regulations
CR-3 Crystal River Unit 3
Duke Energy
Duke Energy Florida, Inc.
IMC Inspection Manual Chapter
IP Inspection Procedure
NRC U.S. Nuclear Regulatory Commission
PSDAR Post Shutdown Decommissioning Activities Report SAFSTOR Long Term Safe Storage
SFP Spent Fuel Pool