MONTHYEARIR 05000302/20240012024-09-23023 September 2024 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3, NRC Inspection Report No. 05000302/2024001 IR 05000302/20230022024-04-17017 April 2024 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2023002 IR 05000302/20220032023-05-25025 May 2023 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2022003 ML23058A2532023-03-22022 March 2023 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River, Unit 3 - NRC Inspection Report No. 05000302/2022003 IR 05000302/20220022022-08-0909 August 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report 05000302/2022002 IR 05000302/20220012022-05-0303 May 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report 05000302/2022001 ML22116A1752022-04-27027 April 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3- Independent Spent Fuel Storage Installation Security Inspection Report 07201035/2022401 IR 05000302/20210042022-01-24024 January 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2021004 IR 05000302/20210032021-11-0909 November 2021 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report Nos. 05000302/2021003 and 07201035/2021001 IR 05000302/20210012021-08-12012 August 2021 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report Nos. 05000302/2021001 and 05000302/2021002 IR 05000302/20200012020-11-19019 November 2020 NRC Inspection Report No. 05000302/2020001, Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3, Crystal River, Florida ML20080P2952020-03-23023 March 2020 Independent Spent Fuel Storage Installation Security Inspection Report 07201035/2020401 ML20050D0142020-02-19019 February 2020 NRC Independent Spent Fuel Storage Installation Inspection Report No. 07201035/2020001, Duke Energy Florida, LLC, Crystal River Unit 3, Crystal River, Florida IR 05000302/20190022019-11-20020 November 2019 NRC Inspection Report No. 05000302/2019002 and Independent Spent Fuel Storage Installation Inspection Report No. 07201035/2019002, Duke Energy Florida, LLC, Crystal River Unit 3, Crystal River, Florida IR 05000302/20190012019-05-0101 May 2019 NRC Inspection Report No. 05000302/2019001, Duke Energy Florida, LLC, Crystal River Unit 3, Crystal River, Florida IR 05000302/20180022018-08-16016 August 2018 NRC Inspection Report No. 05000302/2018002, Duke Energy Florida, LLC, Crystal River Unit 3, Crystal River, Florida ML18158A4792018-05-17017 May 2018 Independent Spent Fuel Storage Installation Security Inspection Report 07201035/2018401 (Cover Letter Only) IR 05000302/20180012018-05-14014 May 2018 NRC Inspection Report No. 05000302/2018001, Duke Energy Florida, LLC, Crystal River Unit 3, Crystal River, Florida ML17341A7972017-12-0707 December 2017 NRC Inspection Report No. 07201035/2017002, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Florida IR 05000302/20170022017-10-26026 October 2017 NRC Inspection Report No. 05000302/2017002, Duke Energy Florida, LLC, Crystal River Unit 3, Crystal River, Florida IR 05000302/20170012017-07-13013 July 2017 NRC Inspection Report No. 05000302/2017001, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Florida IR 05000302/20174012017-04-18018 April 2017 ISFSI, Inspection Report 05000302/2017401 and 0720135/2017401, (Cover Letter Only) IR 05000302/20160032016-12-0606 December 2016 NRC Inspection Report 05000302/2016003, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Florida IR 05000302/20160022016-08-24024 August 2016 NRC Inspection Report No. 05000302/2016002, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Florida IR 05000302/20160012016-05-0202 May 2016 IR 05000302/2016001, Duke Energy Florida, Inc., Crystal River Nuclear Plant, Crystal River, Fl, Inspection Report, Public IR 05000302/20164012016-02-17017 February 2016 IR 05000302/2016401, Duke Energy Florida, Inc., Crystal River Nuclear Plant, Crystal River, Florida (Letter Only) IR 05000302/20154012015-11-0404 November 2015 IR 05000302/2015401, on 10/05-08/2015, Crystal River Nuclear Plant. Cover Letter IR 05000302/20150092015-10-21021 October 2015 Duke Energy Florida, Inc., Crystal River Unit 3, NRC Inspection Report 05000302/2015009 IR 05000302/20150082015-07-28028 July 2015 IR 05000302/2015008 on 5/4-7/2015, 6/22-25/2015 and 6/30/2015, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Fl IR 05000302/20150072015-04-13013 April 2015 IR 05000302-15-007 on 1/1/15 - 3/31/15, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Fl IR 05000302/20140042015-01-12012 January 2015 IR 05000302/2014004, Duke Energy Florida, Inc., Crystal River Unit 3, Crystal River, Florida IR 05000302/20144032014-12-0404 December 2014 IR 05000302-14-403, Duke Energy Florida, Inc. Crystal River Nuclear Plant, Crystal River, Florida(Pub) IR 05000302/20140032014-10-21021 October 2014 NRC Inspection Report No. 05000302/2014003, Duke Energy Florida, Inc., Crystal River Nuclear Plant, Crystal River, Florida IR 05000302/20140022014-07-16016 July 2014 IR 05000302-14-002 on 06/09-12/14, Crystal River Nuclear Plant, Unit 3 IR 05000302/20140012014-04-29029 April 2014 IR 05000302-14-001, on 02/11/14 - 03/31/14, Duke Energy Florida, Inc., Crystal River Nuclear Plant - Unit 3, NRC Inspection Report IR 05000302/20130082013-11-0606 November 2013 IR 05000302-13-008, on 9/30/13 - 10/3/13, Duke Energy Florida, Inc., Crystal River Nuclear Plant, Crystal River, Fl, Review of Operations, Management Oversight, Maintenance, CAP, Fire Protection and Plant Support Activities IR 05000302/20130032013-08-28028 August 2013 IR 05000302-13-003; 04/01/2013 - 07/31/2013; Crystal River Unit 3; In-Plant Airborne Radioactivity Control and Mitigation IR 05000302/20134042013-07-18018 July 2013 IR 05000302-13-404, on 06/07/13, Crystal River Nuclear Generating Plant, Unit 3 IR 05000302/20130022013-04-24024 April 2013 IR 05000302-13-002, on 01/01/2013-03/31/2013, Crystal River Unit 3, Routine Integrated Report IR 05000302/20120012013-03-0404 March 2013 Annual Assessment Letter for Crystal River Nuclear Plant Unit 3 (IR 05000302-12-001) IR 05000302/20120052013-01-28028 January 2013 IR 05000302-12-005; 10/01/2012 -12/31/2012; Crystal River Unit 3; Routine Integrated Report IR 05000302/20125022012-12-0707 December 2012 IR 05000302-12-502; 11/12/2012 - 11/16/2012; Crystal River Unit 3; Baseline Inspection IR 05000302/20124042012-10-30030 October 2012 Nuclear Generating Plant - U.S. Nuclear Regulatory Commission Security Inspection Report 05000302-12-404 IR 05000302/20120042012-10-24024 October 2012 IR 05000302-12-004, 07/01/2012 - 09/30/2012, Crystal River Unit 3; Routine Integrated Report IR 05000302/20124032012-08-17017 August 2012 IR 05000302-12-403, 7/26/2012, Crystal River Unit 3, Cover Letter IR 05000302/20120032012-07-27027 July 2012 IR 05000302-12-003, on 04/01/2012-06/30/2012, Crystal River Unit 3; Routine Integrated Report IR 05000302/20125032012-06-14014 June 2012 Supplemental IR 05000302-12-503, on 04/30/12 - 05/03/2012, Crystal River, Unit 3 IR 05000302/20110022012-04-19019 April 2012 IR 05000302-11-002, on 01/01/2012-03/31/2012, Crystal River Unit 3, Routine Integrated Report IR 05000302/20120072012-03-0808 March 2012 IR 05000302-12-007, January 17 - 23, 2012, and January 30 - February 2, 2012; Crystal River Unit 3; Biennial Inspection of the Problem Identification and Resolution Program ML1206501972012-03-0505 March 2012 Annual Assessment Letter for Crystal River Nuclear Plant Unit 3 2011007 2024-09-23
[Table view] Category:Letter
MONTHYEARIR 05000302/20240012024-09-23023 September 2024 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3, NRC Inspection Report No. 05000302/2024001 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24226B2392024-08-27027 August 2024 Application for License Amendment Request to Add License Condition to Include License Termination Plan Requirements – Acknowledgement of Withdrawal ML24179A0702024-07-26026 July 2024 SHPO S106 Completion Crystal River Unit 3 ML24205A2192024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3: Muscogee Nation ML24205A2182024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3: Seminole Nation of Oklahoma ML24179A0912024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3: Seminole Tribe of Florida ML24205A2202024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3_Miccosukee Tribe of Florida ML24190A1912024-07-0808 July 2024 Fws Concurrence for Crystal River Unit 3 ML24172A2552024-06-20020 June 2024 Fws to NRC Species List: Florida Ecological Services Field Office 06/20/2024 ML24170A9242024-06-18018 June 2024 024-0023697 Crystal River License Termination Plan Unit 3 ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24114A2262024-04-24024 April 2024 Amended Special Package Authorization for the Cr3 Middle Package (Crystal River 3 Middle Package - Docket No. 71-9393) IR 05000302/20230022024-04-17017 April 2024 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2023002 ML24054A0612024-04-0202 April 2024 Request to Initiate Section 106 Consultation Regarding the License Termination Plan for Crystal River Unit 3 in Citrus County, Florida ML24079A2492024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Johnson, Lewis Johnson ML24054A0582024-04-0202 April 2024 Achp S106 Initiation Crystal River Unit 3 - Letter 1 ML24079A2472024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Cypress, Talbert ML24079A2482024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Hill, David Hill ML24054A0812024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Osceola, Marcellus ML24089A0362024-03-29029 March 2024 Response to Audit Plan in Support of Accelerated Decommissioning Partners and Request to Add License Condition to Include License Termination Plan Requirements. W/Enclosures 1 to 5 ML24073A1922024-03-11011 March 2024 Fws to NRC, List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML24054A6452024-02-29029 February 2024 Letter - Reply to Request for RAI Extension Related to the Crystal River License Termination Plan ML24030A7482024-02-12012 February 2024 Audit Report Cover Letter and Report - Crystal River Unit 3 Nuclear Generating Plant LTP ML23342A0942024-01-0909 January 2024 – Independent Spent Fuel Storage Installation Security Inspection Plan ML23354A0632023-12-22022 December 2023 Cover Letter - Crystal River License Termination Plan Request for Additional Information ML23345A1882023-12-0606 December 2023 Fws to NRC Crystal River Species List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML23320A2592023-11-17017 November 2023 STC-23 077 Notification of the Crystal River Unit 3 Generating Plant License Termination Plan Public Meeting and Federal Register Notice ML23313A1322023-11-15015 November 2023 Request for Additional Information for the Environmental Assessment of the License Termination Plan for Crystal River Unit 3 Nuclear Generating Plant ML23310A0712023-11-0707 November 2023 Audit Plan Cover Letter - Crystal River Unit 3 Nuclear Generating Plant LTP ML23187A1112023-07-25025 July 2023 Acceptance of Requested Licensing Action License Request to Add License Condition to Include License Termination Plan Requirements ML23107A2722023-06-13013 June 2023 Letter Transmitting NRC Survey Results for East Settling Pond ML23160A2962023-06-0909 June 2023 Response to Crystal River, Unit 3 – Supplemental Information Needed for Acceptance on the Application for a License Amendment Regarding Approval of the License Termination Plan ML23107A2732023-06-0707 June 2023 Orise Independent Survey Report Dcn 5366-SR-01-0 IR 05000302/20220032023-05-25025 May 2023 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2022003 ML23103A1902023-04-19019 April 2023 Request for Supplemental Information Cover Letter ML23058A2532023-03-22022 March 2023 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River, Unit 3 - NRC Inspection Report No. 05000302/2022003 ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML22265A0192022-09-26026 September 2022 Nuclear Generating Plant - U.S. Nuclear Regulatory Commissions Analysis of ADP CR3, LLCs Decommissioning Funding Status Report (License No. DPR-72, Docket Nos. 50-302 and 72-1035) IR 05000302/20220022022-08-0909 August 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report 05000302/2022002 IR 05000302/20220012022-05-0303 May 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report 05000302/2022001 ML22116A1752022-04-27027 April 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3- Independent Spent Fuel Storage Installation Security Inspection Report 07201035/2022401 ML22105A3992022-04-18018 April 2022 Nuclear Generating Plant - Change in NRC Project Manager ML22011A1362022-01-31031 January 2022 Independent Spent Fuel Storage Installation Security Inspection Plan ML22024A2142022-01-24024 January 2022 Nuclear Generating Plant - NMFS NRC Letter - Crystal River Energy Complex Biological Opinion Status (License No. DPR-72, Docket Nos. 50-302 and 72-1035) IR 05000302/20210042022-01-24024 January 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2021004 ML21351A0052021-12-20020 December 2021 NRC Analysis of ADP CR3, LLC Decommissioning Funding Status Report for the Crystal River Unit 3 Nuclear Generating Plant (License No. DPR-72, Docket Nos. 50-302 and 72-1035) ML21322A2702021-11-24024 November 2021 Nuclear Generating Plant - Issuance of Amendment No. 260 Approving the Independent Spent Fuel Storage Installation Only Security Plan, Rev 3 IR 05000302/20210032021-11-0909 November 2021 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report Nos. 05000302/2021003 and 07201035/2021001 ML21288A4292021-10-18018 October 2021 Letter - Crystal River Unit 3 Nuclear Generating Plant - Correction to Safety Evaluation Related to the Issuance of Amendment No. 259 Approving the Independent Spent Fuel Storage Installation Only Emergency Plan 2024-09-23
[Table view] |
Text
Official Use Only - Security-Related Information UNITED STATES NUCLEAR REGULATORY COMMISSION
REGION I
May 2, 2016
SUBJECT:
NRC INSPECTION REPORT NO. 05000302/2016001, DUKE ENERGY FLORIDA, INC., CRYSTAL RIVER NUCLEAR PLANT, CRYSTAL RIVER, FLORIDA
Dear Mr. Hobbs:
On April 4, 2016, the U.S. Nuclear Regulatory Commission completed an inspection under Inspection Manual Chapter 2561, Decommissioning Power Reactor Inspection Program," at the permanently shut down Crystal River Nuclear Plant Unit 3 (CR-3). An on-site inspection was performed on March 1-3, 2016 and in-office reviews of information supplied by Duke Energy Florida, Inc. were also performed. The inspection examined activities conducted under your license as they relate to safety, security, and compliance with the Commission's rules and regulations, and the conditions of your license. The inspection consisted of observations by the inspectors, interviews with personnel, and a review of procedures and records. The results of the inspection were discussed with you and other members of the CR-3 staff on April 4, 2016, and are described in the enclosed report.
Based on the results of this inspection, the NRC has determined that one Severity Level (SL) IV violation of NRC requirements occurred. This violation is being treated as a Non-Cited Violation (NCV), consistent with Section 2.3.2 of the Enforcement Policy. The NCV contains security related information and is documented in Enclosure 2 of the subject inspection report. If you contest the violation or significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001, with copies to: (1)
the Regional Administrator, Region I; (2) the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and (3) the NRC Senior Decommissioning Inspector, Region I.
Enclosure 2 contains Sensitive Unclassified Non-Safeguards information.
When separated from Enclosure 2, the document is decontrolled.
Official Use Only - Security-Related Information
Official Use Only - Security-Related Information However, the material enclosed in Enclosure 2 contains security-related information in accordance with 10 CFR 2.390(d)(1), and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in Enclosure 2 will not be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. If you choose to provide a response, and security-related information is necessary to provide an acceptable response, please mark your entire response Security-Related Information - Withhold from Public Disclosure under 10 CFR 2.390 in accordance with 10 CFR 2.390(d)(1), and follow instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Current NRC regulations and guidance are included on the NRC's website at www.nrc.gov; select Nuclear Materials; Med, Ind, & Academic Uses; then Regulations, Guidance and Communications. The current Enforcement Policy is included on the NRC's website at www.nrc.gov; select About NRC, Organizations & Functions; Office of Enforcement; Enforcement documents; then Enforcement Policy (Under 'Related Information'). You may also obtain these documents by contacting the Government Printing Office (GPO) toll-free at 1-866-512-1800. The GPO is open from 8:00 a.m. to 5:30 p.m. EST, Monday through Friday (except Federal holidays).
No reply to this letter is required. Please contact Steve Hammann at 610-337-5399 if you have any questions regarding this matter.
Sincerely,
/RA/
Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety
Enclosures:
1. (Public) Inspection Report 05000302/2016001 2. (Non-Public) Inspection Report 05000302/2016001
REGION I==
INSPECTION REPORT Inspection No. 05000302/2016001 Docket No. 05000302 License No. DPR-72 Licensee: Duke Energy Florida, Inc. (Duke Energy)
Facility: Crystal River Unit 3 (CR-3)
Location: 15760 W. Power Line Road Crystal River, FL 34428-6708 Inspection Dates: March 1-3, 2016 Inspectors: Stephen Hammann, Senior Health Physicist Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Briana DeBoer, Health Physicist Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Approved By: Raymond Powell, Chief Decommissioning and Technical Support Branch Division of Nuclear Materials Safety Official Use Only - Security-Related Information Enclosure 1
Official Use Only - Security-Related Information
EXECUTIVE SUMMARY
Duke Energy
Crystal River Nuclear Plant NRC Inspection Report No. 05000302/2016001 An announced CR-3 decommissioning inspection was completed on April 4, 2016. The inspectors performed an on-site inspection the week of March 1-3, 2016. In-office reviews of information supplied by Duke Energy were also performed during the inspection. The inspection included a review of management oversight, organization and staffing, spent fuel pool (SFP) safety, and decommissioning performance. The inspection consisted of observations by the inspectors, interviews with Duke Energy personnel, a review of procedures and records, and plant walk-downs. The NRC's program for overseeing the safe operation of a shut-down nuclear power reactor is described in Inspection Manual Chapter (IMC) 2561,
Decommissioning Power Reactor Inspection Program."
Official Use Only - Security-Related Information ii
Official Use Only - Security-Related Information
REPORT DETAILS
1. Background
On February 20, 2013, Duke Energy sent a letter [Agency Documentation and Management System (ADAMS) Accession Number: ML13056A005] to the NRC certifying the permanent cessation of activities and certifying that the fuel had been permanently removed from the reactor. This met the requirements of 10 Code of Federal Regulations (CFR) 50.82(a)(1)(i) and 50.82(a)(1)(ii). Currently, CR-3 is in the SAFSTOR phase of decommissioning as described in IMC 2561.
2. SAFSTOR Performance and Status Review
a. Inspection Scope
(Inspection Procedures (IPs) 36801, 60801, 71801)
The inspectors performed an on-site inspection the week of March 1-3, 2016. In-office reviews of information supplied by Duke Energy were also performed during the inspection. The inspection consisted of observations by the inspectors, interviews with Duke Energy personnel, a review of procedures and records, and plant walk-downs.
The inspectors conducted document reviews, performed observations, attended site meetings, and interviewed plant personnel to verify the following: regulatory requirements were properly implemented with respect to the site organization, staffing and staff qualifications; certified fuel handler and employee training programs were implemented in accordance with Duke Energy procedures and NRC requirements; Duke Energy established procedures and processes to resolve employee safety concerns, disseminate safety information and effectively resolved identified problems; and Duke Energys decommissioning activities were performed in a manner consistent with the Post Shutdown Decommissioning Activities Report (PSDAR).
The inspectors reviewed CR-3s programs for the safe wet storage of spent fuel. The inspectors performed a walk-down of the SFP and associated support systems to assess material condition, configuration control, and system operation. The inspectors also accompanied chemistry technicians as they sampled and analyzed SFP water, and observed radiation protection technicians performing SFP cleaning activities in order to assess SFP chemistry and cleanliness controls. The inspectors interviewed employees and reviewed work orders, procedures, and water analysis to verify compliance with the technical specifications.
The inspectors observed CR-3 and Areva, Inc. personnel performing holddown spring removals of spent fuel assemblies. The holddown spring removals, along with fuel assembly grid repositioning, are being done to prepare the fuel assemblies for the CR-3 campaign to move all fuel assemblies from the spent fuel pool and into dry cask storage.
The inspectors reviewed the procedures, work plans, radiation work permits, equipment setup, RP coverage of the project, and evaluated CR-3s adherence to procedures.
Official Use Only - Security-Related Information Official Use Only - Security-Related Information
b. Observations and Findings
The inspectors verified that management oversight was adequate for the SAFSTOR phase of decommissioning and that no significant changes had been made to the CR-3 SAFSTOR organization since the previous inspection. The inspectors determined that training programs were being appropriately implemented by the responsible section managers and reported up to the Decommissioning Manager. The inspectors attended a plant safety meeting and found potential safety hazards were being discussed with the staff.
The inspectors verified spent fuel pool chemistry and cleanliness controls were being adequately implemented. The inspectors verified the chiller system installed after CR-3 entered decommissioning to replace the existing SFP cooling system was functioning adequately. The inspectors determined tests had been adequately performed to assess the condition of the carborundum poison material in SFP A.
The inspectors noted that the work being performed on the fuel assemblies is to prepare for placing the fuel assemblies into the dry shielded canisters. The inspectors noted that Areva personnel were performing the activities with oversight and support from CR-3 personnel. The inspectors determined that the project to ensure fuel assemblies are acceptable for dry cask storage is on-going and the next phase will include gauging suspect fuel assemblies to determine if they will fit into cells in the dry shielded canisters.
c. Conclusions
Based on the results of this inspection, no findings of safety significance were identified.
3. Exit Meeting
On April 4, 2016, the inspectors presented the inspection results, via teleconference, to Terry Hobbs, Decommissioning General Manager, and other members of Duke Energys staff. The inspectors confirmed that proprietary information was not removed from the site.
Official Use Only - Security-Related Information Official Use Only - Security-Related Information PARTIAL LIST OF PERSONS CONTACTED Licensee B. Akins, Radiation Protection and Chemistry Manager P. Dixon, Decommissioning Technical Support Manager C. Gavin, Nuclear Performance Specialist T. Hobbs, Decommissioning General Manager J. Lane, Systems Engineer P. Rose, Licensing I. Wilson, Operations and Maintenance Manager K. Shelton, RP Supervisor M. Van Sicklen, Licensing P. Worthington, Engineering Supervisor ITEMS OPEN, CLOSED, AND DISCUSSED None LIST OF
DOCUMENTS REVIEWED
Procedures
AI-1806, CR-3 Safety Committee, Rev. 25
AREVA FS-043, MK-B4 Holddown Spring Removal Procedure, Rev. 08
AREVA FS-097, Foreign Material Removal and Retrieval, Rev. 06
AREVA FS-285, Fuel Assembly Grid Positioning, Rev. 01
CH-400A, Nuclear Chemistry Data Sheets, Primary Water Chemistry and Countroom, Rev. 20
CH-513A, Spent Fuel Coolant Sampling (SFP), Rev. 4
CH-513C, Spent Fuel Coolant Filter 3A&3B/Demineralizer Outlet Sampling (SFDM-1), Rev. 2
CH-572A, FST-1A Sampling, Rev. 3
CH-9000, Spent Fuel Pool Cooling Chilled Water System (ChhE-4A/B) and Control Complex
Cooling Chilled Water System (CHHE-4C) Sampling and Chemical Addition, Rev. 3
EHS-PGM-105, Environmental, Health and Safety Event Reporting and Investigation Program,
Rev. 0
FP-204, Auxiliary Building Fuel Handling Operations, Rev. 6
FP-601C, Operation of Spent Fuel Pool Handling Bridge FHCR-3, Rev. 50
FP-601G, Operation of Spent Fuel Handling Monorail FHCR-3A, Rev. 5
MNT-0007, Foreign Material Exclusion Program, Rev. 0
MNT-020, Cranes and Hoists, Rev. 0
MP-806, Mobile Crane Control, Rev. 14
OP-421C, Operation of the Auxilliary Building Overhead Crane FHCR-5, Rev. 44
OP-421D, Operation of the Spent Fuel Pit Missile Shield Crane FHCR-7, Rev. 26
SP-318, Spent Fuel Pool Boron Concentration Verification, Rev. 3
TAP-403, Conduct of Written Examinations, Rev. 23
TAP-404, Training Documentation and Records, Rev. 10
TAP-408, Development and Conduct of Job Performance Measures, Rev. 11
Official Use Only - Security-Related Information
Official Use Only - Security-Related Information
Procedures (Contd)
TAP-413, Conduct of Operator Continuing Training, Rev. 24
TPP-219, Emergency Response Organization Training Program, Rev 7
TPP-901, Certified Fuel Handler Training and Retraining Program, Rev. 1
TRN-1000, Performance Based Training, Rev. 2
Completed Surveillance Procedures and Surveys
SFP water analysis, 10/06/15 - 3/1/2016
Water sample analysis 10-Feb-2016-003 and 16-Feb-2016-003
Miscellaneous
AR 01960787
CR-3 Grid Strip-HDS-Debris Removal Site Schedule
CR-3 Safety Council Members, October 15, 2015
Maintenance CRC Meeting Minutes, 10-06-15
Operations CRC Meeting Minutes, September 23, 2015
RWP #1061, Rev. 0
SAF-2176, Job Safety Analysis (JSA)
SAFSTOR CRC Meeting Minutes, September 9, 2015
Station Performance Oversight Committee (SPOC) Meeting Minutes, December 15, 2015
Team Safety - Top Safety Concerns 2015, 11/09/2015
Work Orders
WO 01929241 01, High Density Rack Poison SAM
WO 20037898 01, Clean the A&B SFP & Cask Loading Area
WO 20037931 01, Spent Fuel Pool Boron Concentration Verification
WO 13535579, Sample Mold in Buildings & Analysis
LIST OF ACRONYMS USED
ADAMS Agency Documentation and Management System
CFR Code of Federal Regulations
CR-3 Crystal River Unit 3
Duke Energy Duke Energy Florida, Inc.
IMC Inspection Manual Chapter
IP Inspection Procedure
NRC U.S. Nuclear Regulatory Commission
PSDAR Post Shutdown Decommissioning Activities Report
SAFSTOR Long Term Safe Storage
SFP Spent Fuel Pool
Official Use Only - Security-Related Information
1