TXX-6960, Final Deficiency Rept CP-86-11 Re Component Cooling Water (CCW) Pump Impeller Linear Indications.Initially Reported on 860623.All CCW Pump Impellers Inspected & Corrective Action to Repair Linear Indications Completed

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept CP-86-11 Re Component Cooling Water (CCW) Pump Impeller Linear Indications.Initially Reported on 860623.All CCW Pump Impellers Inspected & Corrective Action to Repair Linear Indications Completed
ML20236R256
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 11/17/1987
From: Counsil W, John Marshall
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-86-11, TXX-6960, NUDOCS 8711230183
Download: ML20236R256 (1)


Text

__

l

)

m

==

l

~

Log # TXX-6960 Fi1e # 10110 909.2 filELECTRIC

" # IU"" * * ('}

j w,,,, g , c,,,,,, November 17, 1987 Esecutne Vwe henient I

U. S. Nuclear Regulatory Commission J ATIN: Document Control Desk Washington, D.C. 20555 1

l

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446-COMPO!1ENT COOLING WATER PUMP IMPELLER LINEAR INDICATION $'

SDAR: CP-86-11 (FINALREPORT) l I l Gentlemen:

On June 23, 1986, we notified you by our letter logged TXX-4871 of a deficiency involving linear indication of impellers for the Component Cooling i Water (CCW) pumps which we deemed reportable under the provisions of

)

10CFR50.55(e). This is a final report submitted to status corrective actions j imple.nented to date. Our last report was logged TXX-6682, dated September 4, l i

1987.

i All CCW pump impellers for units 1 and 2 have been inspected and corrective action to repair the linear indications has been completed. This completes  ;

our corrective action on this issue.

Supporting documentation is available at the CPSES site for your Inspectors'  !

review. J Very truly yours,

[t/, 6, Co u n Sc (

W. G. Counsil By: I J. 5. Marshall i Supervisor, Generic Licensing' l GLB/mgt i

i c - Mr. R. D. Martin, Region IV y .:

Resident Inspectors, CPSES (3) p; '

/ , 1 Q

S 45 I O $

  1. N) Wrth Othe Street . LII HI . . Dallas, Texas 7$20:

L.________-_-__--_ - - - - _ . -