PNO-II-87-040:on 870623,unit Manually Shut Down Following Estimated 40 Gpm Leak in Rcs.Caused by Packing on Reactor Coolant Loop Stop Valve.Licensee Preparing Unit to Go to Mode 5 to Effect Repairs
ML20234C452
Person / Time
Site: Surry Dominion icon.png
Issue date: 06/23/1987
From: Son Ninh
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
PNO-II-87-040, PNO-II-87-40, NUDOCS 8707060478
Download: ML20234C452 (2)


_-_ _ _ - _ _ _ _

  • June 23, 1987 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PN0-II-87-40  :

This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without veriff-cation or evaluation, and is basically all that is.known by the Region 11 staff on this

-date.

FAC CITY: Virginia Electric & Power Company Licensee Emergency Classification:

Surry Unit 1 X Notification of Unusual Event Docket No: 50-280 Alert  !

Surry, Virginia Site Area Emergency i General Emergency Not Applicable

SUBJECT:

UNIT SHUT DOWN TO REPAIR REACTOR COOLANT. SYSTEM LEAK The licensee manually shut down ' Unit 1 on June 23 at 3:32 p.m. (EDT) after experiencing an unidentified leak of an estimated 40 gallons per minute in the Reactor Coolant System' (RCS).

The . location of the leak was subsequently identified as packing on a reactor coolant loop stop valve.

The licensee ' manually backseated all loop stop valves and performed a leak test which determined that the unidentified leak rate had been reduced from 40 gallons per minute to less than a gallon per minute (.88 gpm).

l The unit is currently in Mode 4 and is preparing to go to Mode 5 in order to effect i repairs.

The NRC resident inspector will perform a routine followup.

The Commonwealth of Virginia has been informed. -

Both the licensee and the NRC are prepared to respond to media inquiries should they occur.

l The NRC received initial notification of this event by telephone from the licensee to the I headquarters Incident Response Center at 3:54 p.m. (EDT) on June 23. l This information is current as of-11:00 a.m. (EDT) on June 24.

Contact:

S. Ninh 242-4668 I

DISTRIBUTION:

H. Street MNBB Phillips E/W Willste Mail:

Chairman Zech 'EII6- NRR TT' NMSS ADM:DMB Comm. Roberts PA OIA RES D01: Trans Only Comm. Asselstine MPA AE0D .

Applicable State ,

Comm. Bernth.1 ELD ]

Comm. Carr Air Rights INP0-ig~,K SECY SP NSAC R Regions: " h.N /

B707060478 870623 i PDR I&E t

l PNO-II-87-040 PDR s t- ___ _-= -- _Y?

1 4

Licensee: fhh

!%if%d'!:"i"lM site ([3L-1

_ ________-_-___--a

Licensee: fl.h (ReactorLidensees) l ApplicableResidentSite((3b l

l 1

l' l

l l

l l

i

- - _ _ - _ _ _ _ _ ._ _ .._-________n