ML20094H360

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Oct 1995 for North Anna Power Station
ML20094H360
Person / Time
Site: North Anna  Dominion icon.png
Issue date: 10/31/1995
From: Saunders R, Stall J
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
95-580, NUDOCS 9511140138
Download: ML20094H360 (12)


Text

. _ . - - . . _- . . - , - . = . .

VIRGINIA ELECTRIC AND Powen COMI'ANY

- , RICIIMOND,VIROINIA 200 61 November 8,1995 4

i U. S. Nuclear Regulatory Commission Serial No.95-580 Attention: Document Control Desk NL&OS/JHUCMC Washington, D.C. 20555 Docket Nos. 50-338 50-339 License Nos. NPF-4 NPF-7 .

l Gentlemen: l VIRGINIA ELECTRIC AND POWER COMPANY l NORTH ANNA POWER STATION UNITS 1 AND 2 '

MONTHLY OPERATING REPORT Enclosed is the October 1995 Monthly Operating Report for North Anna Power Station )

Units 1 and 2. l Very truly yours, R. F. Saunders Vice President-Nuclear Operations Enclosure cc: U.S. Nuclear Regulatory Commission Region ll 101 Marietta Street, NW Suite 2900 Atlanta, GA 30323 j

Mr. R. D. McWhorter NRC Senior Resident inspector North Anna Power Station

.<.4 i s i i V '_ e1  ;

951114o138 951031 .

PDR ADOCK 0500o338 /

R PDR l l

_ - . . . . . ~.. . ~ . . . . . . .. - .. . .- .-. .

4 l

i j

i VIRGINIA POWER COMPANY  !

NORTH ANNA POWER STATION  !

MONTHLY OPERATING REPORT l 1

1 MONTH: October YEAR: 1995 1 l l l

1 l ,

I l

l l

I f ,

l Approved:

Oh ELL' -

pT stauon Manager m ----

. OPERATING DATA REPORT

. DOCKET NO.: 50-338 DATE: November 5, 1995 CONTACT: J. A. Stall PHONE: (703) 894-2101 OPERATING STATUS

1. Unit Name:................................ North Anna 1
2. R eport i ng Per i od: . . . . . . . . . . . . . . . . . . . . . . . . 0c t ober 1995
3. Licensed Thermal Power (MWt):............. 2,893
4. Nameplate Rating (Gross MWe):............. 994
5. Design Electrical Rating (Net MWe):....... 907
6. Maximum Dependable capacity (Gross MWe):.. 940
7. Maxiran Dependable Capacity (Net MWe):.... 893
8. If changes occur in capacity Ratings (Items No. 3 thru 7) since last report, give reasons: N/A
9. Power level to which restricted, if any (Net MWe): _N /A
10. Reasons for restrictions, if any: N/A This Month Y t-D Cumulative
11. Hours i n R eport i ng Per i od. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745.0 7,296.0 152,172.0
12. Nunber of Hours Reactor was Cr i t ical . . . . . . . . . . . . . . . . . . . . . . 745.0 7,274.6 115,722.4
13. R: actor Reserve Shutdown Hours............................ 0.0 20.9 6,951.4 it. Hours Generator 0n-Line................................... 745.0 7,269.8 112,723.5
15. Unit Reserve Shutdown Hours............................... 0.0 0.0 0.0
16. Gross Thermal Energy Generated (MWH ) . . . . . . . . . . . . . . . . . . . . . . 2,154,437.2 20,960,264.4 301,145,844.3
17. Gross Electrical Energy Generated (MWH)................... 706,678.0 6,878,827.0 98,954,447.0
18. nit Electrical Energy Generated (MWH)..................... 671,999.0 6,541,165.0 93,743,451.0
19. Unit Service Factor....................................... 100.0% 99.6% 74.1%
20. Unit Availability Factor.................................. 100.0% 99.6% 74.1%
21. Unit Capacity Factor (using MDC Net)...................... 101.0% 99.9% 68.9%
22. Uni t Capaci ty Fact or (using DER Net) . . . . . . . . . . . . . . . . . . . . . . 99.5% 98.8% 67.9%
23. Ftrced Outage Rate........................................ 0.0% 0.4% 9.4%
25. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):_ Refueling Outage Scheduled far February 10, 1995, Duration 34 Days
25. If Shutdown at end of Report Period, estimated time of Startup: _N/A
26. Units in Test Status (Prior to Connercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

l AVERAGE DAILY UNIT POWER LEVEL Docket No.: 50-338 l Unit: NA-1

! Date: November 5, 1995 Contact J. A. Stall Phone: (703) 894-2101 l

l MONTH: October 1995 DAY AVERAGE DAILY POWER DAY AVERAGE DAILY POWER LEVEL (MWe-Net) LEVEL (MWe-Net) t- 1 902 17 904 l 2 902 18 905 l 3 901 19 901 l 4 901 20 902 5 901 21 902 6 901 22 901 7 901 23 901 8 901 24 901 9 902 25 902 10 904 26 901 11 904 27 894 12 904 28 903 13 904 29 902 14 904 30 902 15 905 31 902 16 903 Instructions:

On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt, I

NORTH ANNA POWER STATION I

.. i UNIT NO.s 1 MONTH: October

SUMMARY

OF OPERATING EXPERIENCE Page 1 of 1 ,

Listed below in chronological sequence is a summary of operating i experiences for this month which required load reductions or resulted in significant non-load related incidents.

Date Time Data i I

October 01, 1995 0000 Began month with unit at 100% power, 948 MWe.

October 27, 1995 0918 Commenced power reduction from 100%, 948 MWe for l Turbine Valve Freedom Test (TVFT).

1004 Unit stable at 93% power, 875 MWe for TVFT.

1111 Completed TVFT satisfactorily.

1133 Commenced ramp up to 100% power from 92% power, 873 MWe, 1245 Unit stable at 100% power, 944 MWe.

October 31, 1995 2400 Ended month with unit at 100% power, 947 MWe.

l l

1 i

. Page 1 of __1 i

UNIT SHUTDOWN AND POWER REDUCTIONS i Explanation Sheet I Docket No.: 50-338 Report Month October Unit Name: NA-1 Years 1995 Date: November 5, 1995

Contact:

J. A. Stall

  • No entry this month.

i 1

l l

l i

i I

i l

l l

l.

l i

L 4

~

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.: 50-338 UNIT NAME: NA-1, DATE: November 5, 1995 REPORT MONTH: October 1 1995 CONTACT: J. A. Stall PHONE: (703) 894-2101 1 2 3 4 5 No. Date Type Duration Reason Method of Licensee System Component Cause & Corrective (hrs) Shutting Event Code Code Action to Down Reactor Report # Prevent Recurrence o No Entry This Month 1: Type 2: Reason 3: Method 4:

F= Forced A= Equipment Failure (explain) 1= Manual Exhibit F - Instructions S= Scheduled B= Maintenance or Test 2= Manual Scram for preparation of Data C= Refueling 3= Automatic Scram Entry Sheets for Licensee D= Regulatory Restriction 4= Continuations Event Report (LER) File E= Operator Training & License Examination 5= Load Reduction (NUREG-0161)

F= Administrative 9=Other G= Operational Error 5:

H=Other (explain) Exhibit H - Same Source

. OPERATING DATA REPORT l

.' DOCKET Wo.: 50-339 DATE: November 5,1995 ,

CONTACT: J. A. Stall J PHONE: (703) 894-2101 i

l i

OPERATING STATUS

1. Unit Name:................................ North Anna 2
2. Repor t i ng Per i od: . . . . . . . . . . . . . . . . . . . . . . . . 0ctober 1995
3. Licensed Thermal Power (MWt) ............. 2893
4. Nameplate Rating (Gross MWe):............. 979
5. Design Electrical Rating (Net MWe):....... 907
6. Maximun Dependable Capacity (Gross MWe):.. 944
7. Maximum Dependable Capacity (Net MWe):.... 897 j i

l

8. If changes occur in Capacity Ratings (Items No. 3 thru 7) since last report, give reasons: N/A

)

9. Power level to which restricted, if any (Net MWe): N/A
10. R;csons for restrictions, if any: N/A l

This Month Y-t D Cumulative i

11. Hours i n R eport i ng Per i od. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745.0 7,296.0 130,440.0

- 12. Number of H ours R eactor was Cri t i cal . . . . . . . . . . . . . . . . . . . . . . 745.0 5,685.7 108,619.2 j

13. R actor Reserve Shutdown Hours............................ 0.0 1.3 6,510.2 l
14. H our s Generat or 0n- L i ne. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745.0 5,653.9 107,489.6 l
15. Unit Reserve Sherdown Hours............................... 0.0 0.0 0.0 l
16. Gross The rmal Energy Generat ed (MWH) . . . . . . . . . . . . . . . . . . . . . 2,149,192.2 15,236,340.1 291,852,304.1 '
17. Gross E lectri cal Energy Generat ed (MWH) . . . . . . . . . . . . . . . . . . . 708,837.0 4,993,762.0 95,470,619.0
18. N;t E lect ri cal Energy Generat ed (MWH) . . . . . . . . . . . . . . . . . . . . . 674,144.0 4,735,B81.0 91,275,849.0
19. Unit Service Factor....................................... 100.0% 77.5% 82.4%
20. Unit Availability Factor.................................. 100.0% 77.5% 82.4%
21. Unit Capacity Factor (using MDC Net)...................... 100.9% 72.8% 77.8%
22. Uni t capaci ty Factor (us i ng DER Net ) . . . . . . . . . . . . . . . . . . . . . . 99.8% 71.6% 77.2%
23. Fcreed Outage Rate........................................ 0.0% 0.0% 4.9%
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each): N/A j i

l i

25. If Shutdown at end of Report Period, estimated time of Startup: N/A

]

26. Units in Test Status (Prior to Commercial Operation):  !

Forecast Achieved l INITIAL CRITICALITY ]

INITIAL ELECTRICITY COMMERCIAL OPERATION

__ _ _ . = . . . . _ . ._ .

- t c

AVERAGE DAILY UNIT POWER LEVEL i i

Docket No.: 50-339 Unit: NA-2 L November 5, 1995 l

Dates i

Contact J. A. Stall -

Phone: (703) 894-2101 l l i

I l MONTH: October 1995  ;

f i

f DAY AVERAGE DAILY POWER DAY AVERAGE DAILY POWER LEVEL (MWe-Net) LEVEL (MWe-Net) 1 910 17 906 2 909 18 907 '

3 908 ,

19 909 4 908 20 909 5 908 21 909 ,

6 841 22 909 l

7 884 23 909 l l 8 907 24 909 l 9 906 25 910 10 905 26 909 11 905 27 909 -

12 904 28 910 13 905 29 910 i 14 905 30 910 l

15 906 31 911 l 16 905 i

1 i

Instructions:

On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

4 1

l l

i _ _

, . NORTH ANNA POWER STATION UNIT NO.: 2

. MONTH: October

SUMMARY

OF OPERATING EXPERIENCE

~

Page 1 of 1 Listed below in chronological sequence is a summary of operating experiences for this month which required load reductions or resulted in significant non-load related incidents.

Date Time Data October 01, 1995 0000 Began month with unit stable at 100% power, 954 MWe.

October 06, 1995 0738 Commenced unit ramp down for Turbine Valve Freedom Test (TVFT) from 100% power, 946 MWe.

  • 0809 Unit stable at 90% power, 862 MWe, 0900 Completed TVFT satisfactorily. Holding power ,

at 90% for Condenser Waterbox inspections.  !

October 07, 1995 0418 Commenced unit ramp . following "A" Condenser Waterbox maintenance from 90% power, 854 Mwe. -

One tube was plugged. I i

l 0517 Stopped ramp at 98% power, 924 Mwe for calorimetric. -

l 0625 Commenced ramp to 100% power.

I

! 0647 Unit stable at 100% power, 947 Mwe. j l

l October 31, 1995 2400 Ended month with unit stable at 100% power, l 959 Mwe. l l

l I

1 l

i I

l

. . . . ~ . . . . _ . . . . . _ - . . . . . _ - . . ~.. . . ..

Page 1 of 1 UNIT SHUTDOWN AND POWER REDUCTIONS Explanation Sheet Docket No.: 50-339 Report Month October Unit Names NA-2 Year 1995 Date November 5, 1995

Contact:

J. A. Stall

  • - No Entry This Month F

l t

I r t

e t

i l

L f

i

L' .

DOCKET NO.: 50-339- ' " '

UNIT NAME:  ; N A - 2'. .

DATE: November 5, 1995 REPORT MONTH: October 1 1995 CONTACT: J. A. Stal-1  ;

PHONE: (703) 894-2101' i

1 2 3 4 5 Mo.

Date Type Duration Reason Method of Licensee System- Component Cause & Corrective (hrs) Shutting Event Code Code ' Action-to Down Reactor Report # Prevent Recurrence ONo Entry This Month 1: Type 2: Reason 3: Method. 4: I F= Forced A= Equipment Failure (explain)- 1= Manual Exhibit F - Instructions S= Scheduled B= Maintenance or Test 2= Manual Scram for preparation of Data' 2 C= Refueling 3= Automatic Scram- Entry Sheets for Licensee {

D= Regulatory Restriction 4= Continuations Event Report (LER) File '

E= Operator Training & License Examination 5= Load Reduction (NUREG-0161) '

F= Administrative 9=Other G= Operational Error 5:

H=Other (explain) Exhibit H .Same Source i

_ - - . _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ - - _ _ _ _ - _ _ _ _ _ - - - - _ _ _ - _ - - - - _ _ _ _ _ _ _ - _ _ _ - _ _ - _ _ _ - - _ - _ _ _ _ _ _ _ .