Co Rept 50-219/65-03 on 650930,1022 & 1113.No Items of Noncompliance Noted.Major Areas Inspected:Overpressure Test of Dry Well
ML20086U115
Person / Time
Site: Oyster Creek
Issue date: 11/26/1965
From: Sears J
US ATOMIC ENERGY COMMISSION (AEC)
To:
Shared Package
ML20086U000 List: ... further results
References
FOIA-95-36 50-219-65-03, 50-219-65-3, NUDOCS 9508030276
Download: ML20086U115 (3)


Text

-

=

  • w.w %

sep.+

sent f,,,,,.

.o g

l 7-

W

?A U.

S... ATOMIC ENERGY COMMISSION t

REGION I DIVISION OF COMPLIANCE a

November 26, 1965 j

CO REPORT NO. 219/65-3

+:4 i

1

(

Title:

JERSEY CENTRAL POWER & LIGHT COMPANY i;

fj LICENSE NO.

CPPR-15 l

r-Dates of Visits:

September-30, 1965, October'22,'1965, and November 13, 1965 By J

R. Sea eactor Inspector Z

SUMMARY

An initial visit was made with the President of the Jersey.

Central Power & Light Company.

The overpressure test of the dry well at 71.3 psig was witnessed on November 13, 1965.

{

DETAILS t

I.

Scope of Visits i

Two visits were made by John R. Sears, Reactor Inspector, Region I, Division of Compliance, to the Jersey Central reactor at Oyster Creek, New Jersey, on October 22, 1965, and November

~

13, 1965, to observe the pneumatic overload test, and the prepar-ations ' therefore, of the dry well for this reactor.

l A visit was made by R. T. Carlson, assigned back-up in-spector, J..P. O'Reilly, Senior Reactor Inspector, and J. R.

)'

Sears, Region I, Division of Compliance, on September 30, p 1965, to the offices of the Jersey Central. Power & Light i

j ny in Morristown, New Jersey, to discuss with Mr. -Mac Elwaynb President, and Mr.- Donald Rees, Project Manager, the basic purpose of the compliance Division's program of reactor inspection and management appraisal.

(continued) 9500030276 950227 PDR FOIA DEKOK95-36 PDR

I

, g. o,. :. ~...

_~

t-r f,.

ej[

4 3

"~

./-

,h}

i s

f.

i i

.II. - Results of Visits e

if:-

A.

Pneumatic Overload-Test i

~

3 The downcomers from'the-dry well into the' toroidal i

suppression chamber had been sealed with welded caps.. ' Both -

y+

doors of the airlock were closed.

The airlock was at at-

.[

mospheric pressure.

Pumping of-air'into the dry well had

'}

commenced at 1700 on November ~12, 1965.

The pressure t

reached the? overload pressure of 71.3'psig'at 0550 on November'13, 1965, and was. held there until 0620.

The j

' dry well pressure was then lowered to the design value.of i

62 psig.

The airlock was then pressurized to 71.3 psig and held there for approximately half an hour.

}

i The pressures were indicated on three'O - 100 psig l

Bourdon-tube, Dinagauge pressure gauges.

The_ pressures were also recorded-on a Foxboro' recorder.

The recorder was l

tagged with a Chicago Bridge and Iron' Company calibration tag which reads " Calibrated at Hillside by C.W. Beader -

Range 0 - 100. psi; calibrated at 72, True O PSI gauge l

reads 0; Caution:.Make No Field Adjustments".

The test was witnessed by the following:

i Mr. John R. Sears, Reactor Inspector, ABC Mr. Aba Dunning, GE 6 * 'l - G *t N ~ D 8 8 Mr. Ted Brown, GE Mr. Giles Willis, Burns & Roe

,IM Mr. Walter J. Conegys, Hartford Steam Boiler

'& Insurance Company

' l Mr. Forrest Roberts, Chicago Bridge and Iron Company

[

Mr. Darrel Longlinais, Chicago Bridge and Iron Company Mr. Ivan Finfrock, Jersey Central (continued) 4 l

d'9'"-1rP" T

1

~em-i.er w

,-rk w

-tmerW m-n

-w 1 w y-we

+We-ytwe= + e:rp9 dyJ g w wt y 4 m t * + 'Cr M m-*F W egf P*dD"9"rW*

AQ(!__

L L. s.-

^ =. G*

^

()

L j,

if

. i.

i- '

~~~

1!

u-iT Results of Visits (continued)

)v, i

~:;

g A 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> ' leak rate test _ at-62.psig was scheduled to commence after the overload test.

l

.1 i

fi

- Mr. Roberts stat ed - that - the ' suppression chamber i

would be tested in approximately one month.

I-B.

Airlock-Interlock l

The airlock interlock.was observed.to be a. strictly

?

mechanical device.. There are handwheels'for opening either door inside the airlock and on each end of the airlock.

Defeat of the mechanical interlock requires removal of a cover plate over the interlock mechanism and discon-nection of -a shaft within.