August 27 -1969
-j
(' j; R. T. Carlson,- Senior Reactor Int,pector I'
Region I, Division of. Compliance JERSEY CENTRAL POWER & LIGHT COMPANY (OYSTER CREEK 1)
DOCKET No. 50-219-Attached is my report of a~ visit.to the subject facility on August 13-15, 1969. No items-of. safety significance were identi-fied. One. item of noncompliance.was noted, for which it suggested that a. Form AEC-592 be sent to the licensee for the purpose of obtaining a formal commitment from the licensee on a suitable replacement for the retired Maintenance Supervisor.
i
'i The power ascension information contained in'the' report should
-l be considered of an interim nature since the program has. not yet gotten off the ground. GE-is aware that carry-under may be greater than predicted because of the use of internal steam.
separators and will be accounting for.it in the MCHFR calcu-lations.
Because of delays caused by the air ejector-and. cleanup system flow control' problems, it appears that-the.fifth recirculation pump will be back in service before the reactor is operated at appreciable power levels.
The firing of-the poison injection system explosive valves does not appear significant.
We will continue to monitor activities associated with the secondary containment building leak rate.
R. T. Dodds Reactor. Inspector AUG f 91969 9509070083 950227
-PDR FOIA
'DEKOK95-36 PDR g