MONTHYEARML18107A3441999-06-0101 June 1999 Interim Part 21 Rept Re Premature Over Voltage Protection Actuation in Circuit Specific Application in Dc Power Supply.Testing & Evaluation Activities Will Be Completed on 990716 ML20127K8811993-01-0606 January 1993 Part 21 Rept Re Engine Driven Fuel Oil Pump Being Returned for Proper Configuration Due to Portion of O Ring Missing from Plug ML20128G5101985-05-24024 May 1985 Part 21 Rept Re Heat Numbers to Be Added & Deleted from Sublist Sheet A,Based on Review of NRC ML20096E6611984-08-20020 August 1984 Interim Potential Const Deficiency Rept Re Silicon Controlled Rectifiers in Emergency Diesel Generator Exciters.Initially Reported on 840503.Item Not Reportable Per 10CFR50.55(e) ML20094F5331984-07-18018 July 1984 Interim Part 21/deficiency Rept Re Busses on Colt Industries Diesel Generator Lube Oil Pump Discharge Nozzles.Initially Reported on 840425.Design for Tapered Thread Adapter Changed.Next Rept Expected by 840807 ML20091N9811984-06-0404 June 1984 Interim Part 21 & Const Deficiency Rept Re Ethylene Propylene Seals on Four Gh Bettis Actuators Which May Swell Due to Absorbing Oils from Actuator Lubricant.Initially Reported on 840503.GH Bettis Submitted Part 21 Rept ML20091N8761984-06-0101 June 1984 Interim Part 21 & Deficiency Rept Re Installation of Four Generator Potential Transformer & Basler Electric Exciter Control Panels.Initially Reported on 840503.Problem Subj of Part 21 Rept Submitted to Region III by Basler Electric ML20091N8881984-06-0101 June 1984 Interim Potential Const Deficiency Rept Re 13 Defective GE Hea Relays Due to Malfunction in Trip Force Values.Initially Reported on 840502.Replacement Relays from GE Scheduled for Aug 1984.Next Rept Will Be Submitted by 840921 ML20081D0081984-02-29029 February 1984 Potentially Significant Const Deficiency Rept Re Defective Capstan Springs in Itt Grinnel Shock Arrestors.Initially Reported on 831024.Condition Does Not Warrant Coming Offline to Replace Springs.Next Rept by 840429 ML20080S4111984-02-24024 February 1984 Part 21 Rept Re Reportable Defects on Certain AKR-30 & AKR-50 Low Voltage Power Circuit Breakers Delivered for Use at Facility.Breakers Currently Under Repair,Reinsp & Recertification ML20080A1201984-01-18018 January 1984 Interim Deficiency Rept Re Failure of GE Type AKR-30 Circuit Breakers to Operate Properly.Initially Reported on 831223. Caused by Inadequate Mechanical Loading of Closing Spring. Investigation in Progress.Next Rept by 840321 ML20079R5061984-01-0606 January 1984 Interim Potential Const Deficiency Rept Re Agastat Time Delay Relays.Initially Reported on 831207.Four Defective Relays Identified.Next Rept by 840125 ML20082R0141983-11-23023 November 1983 Significant Const Deficiency Rept Re Defective Capstan Springs in Itt Grinnell Mechanical Shock Arrestors.Initially Reported on 831024.Springs Will Be Removed or Replaced & NDE Performed.Final Rept Expected by 840229 ML20082B7161983-10-28028 October 1983 Interim Const Deficiency Rept Re Altered Expansion Anchors. Initially Reported on 830816.Former Craft Employee Deliberately Circumvented Expansion Anchor Installation Program.Supports Will Be Reworked ML20076F1631983-08-15015 August 1983 Interim Deficiency Rept Re Heat Treatment of Stainless Steel Flanges.Initially Reported on 830601.Test Results Indicate Safe Operation Not Adversely Affected Had Problem Gone Undetected.Item Not Reportable Per 10CFR50.55(e) ML20072N0891983-06-30030 June 1983 Interim Deficiency Rept Re Possible Lack of Heat Treatment on Stainless Steel Flanges Mfg by Tube-Line Corp.Initially Reported on 830601.Affected Flanges Removed from Svc. Bechtel Providing Analysis.Next Rept by 830815 ML20074A2001983-05-0505 May 1983 Interim Significant Const Deficiency Rept Re Mechanical Shock Arrest or Brackets Supplied by Itt Grinnell W/ Potential Interference Problems.Initially Reported on 830413.Affected Parts Returned to Itt Grinnell for Rework ML20073T3201983-05-0202 May 1983 Significant Const Deficiency Rept Re Weld Defects in Class IE Cabinets.Initially Reported on 830125.Bailey Controls Co Reworked All Affected Cabinets ML20073S1741983-04-28028 April 1983 Deficiency Rept Re Scribed Lines on Small Bore Piping Resulting in Sharp Discontinuities.Initially Reported on 830124.Repairs Will Involve Replacing Pipe,Blending Out Scribe Line or Welding.Completion Expected by 830530 ML20073E1741983-03-31031 March 1983 Significant Const Deficiency Rept Re Use of Incorrect Weld Filler Matl by GE in Root of Welds Connecting Control Rod Drive Housing to Reactor Pressure Vessel Stub Tools. Initially Reported Verbally on 821124 ML20072R2151983-03-21021 March 1983 Interim Significant Const Deficiency Rept Re Use of Fiber Shims,Poor Wiring Practices & Use of Unqualified Electrical Components on Limitorque Valve Operators.Initially Reported on 810619.Defects Will Be Reworked Per Procedure SWP/P-E-18 ML20071F0051983-02-28028 February 1983 Interim Deficiency Rept Re Defective Spot Welds in Four Class IE Termination Cabinet Assemblies.Initially Reported on 830125.Defective Cabinets Reworked by Bailey Controls Co.Final Rept Will Be Submitted by 830430 ML20071C9771983-02-24024 February 1983 Interim Deficiency Rept Re Const of Scribed Lines on Small Bore Piping Used in Gauging Socket Weld Locations.Initially Reported on 830124.Investigation Underway.Final Rept to Be Submitted by 830430 ML20071B5791983-02-15015 February 1983 Significant Const Deficiency Rept Re Emergency Diesel Generators.Initially Reported on 821213.Inadvertent Contamination W/Diesel Fuel by Elastomer Seal (O Ring), Resulted in Binding or Malfunction.Elastomer Seals Removed ML20028F4951983-01-18018 January 1983 Interim Deficiency Rept Re Grout Intrusion Into Drywell Airgap.Initially Reported on 820920.Grout Will Be Removed by 830225 ML20028D6611983-01-11011 January 1983 Interim Potential Const Deficiency Rept Re Emergency Diesel Generator O Rings.Initially Reported on 821213.Colt Industries Reported Potential Problem If Cooling Sys Contaminated W/Diesel Fuel.Also Reportable Per Part 21 ML20064F3351982-12-27027 December 1982 Interim Deficiency Rept Re Cracking in Control Rod Driveline Housing Welds Due to Const Error in Root Welds.Initially Reported on 821124.Affected Welds Ground Out,All Weld Metal Removed & Correct Weld Filler Matl Reinstalled ML20069Q2231982-11-29029 November 1982 Deficiency Rept Re Significant Const Deficiency Underestimated Annulus Pressurization Loads.Initially Reported on 821028.Independent Technical Review of Design Calculations Performed ML20065S3161982-10-21021 October 1982 Interim Significant Const Deficiency Rept Re Limitorque Valve Operators.Initially Reported on 810619.Instructions for Operator Insp & Rework Will Be Included in Cable Termination Work Procedure Scheduled for Issuance by 821231 ML20065S2771982-10-20020 October 1982 Interim Deficiency Rept Re Grout Intrusion Into Drywell Airgap.Initially Reported on 820920.Fiberoptics Used for Identification,Map Intrusion & Laitance.Hydrolaser Removal of Grout Intrusions & Other Removal Methods Researched ML20069F6821982-09-15015 September 1982 Final Significant Const Deficiency Rept Re Corrosion Inhibitor Effects on Solder Used to Stake Locking Nuts on Thermostatic Valve Override Assemblies.Initially Reported on 820702.Locking Nuts Fitted W/Swaged Locking by 821126 ML20063B8191982-08-13013 August 1982 Final Significant Const Deficiency Rept Re Torque Values of Stud to Nut Combinations Securing Spider Assembly in Diesel Generator.Initially Reported on 820514.Matter Not Reportable Per 10CFR50.55(e) ML20062H3221982-08-0202 August 1982 Interim Deficiency Rept Re Deleterious Effects Corrosion Inhibitors Have on Solder Used to Stake Locking Nuts on Thermostatic Valve Override Assemblies.Initially Reported on 820702.Final Rept Expected by 820924 ML20058J0401982-07-29029 July 1982 Interim Significant Const Deficiency Rept Re Hpci/Reactor Core Isolation Cooling Exhaust Check Valves.Initially Reported on 811117.Bechtel Analysis Indicates Potential Valve Failure.Next Rept Expected 820915 ML20054J2001982-06-11011 June 1982 Final Deficiency Rept Re Auxiliary Bldg Seismic Analysis. Results of Oct 1981 Auxiliary Bldg Seismic Analysis Inconsistent w/1975 Analysis.Caused by Methodological Difference.Revised Spectra Curves to Be Used for Equipment ML20054J3321982-06-10010 June 1982 Interim Deficiency Rept Re Diesel Generator Bolt Torquing, Initially Reported on 820514.Verification of Requisite Torque Valves on Generator S/N 700510R1 Pending Availability of Manufacturer Representatives ML20054C4691982-04-0101 April 1982 Part 21 Rept Re Hma Relays W/Contact Leads Not Fully Insulated,Initially Reported 810708.No Operating BWRs Utilize Subj Hma Relays.All Potential Problems Will Be Corrected Before Startup ML20040B4391982-01-11011 January 1982 Final Deficiency Rept Re Damaged Bellows Assembly,Initially Reported 811104.Apparently Caused by Electrical Arcing.No Repair or Rework Contemplated Due to Facility Cancellation ML20040B2081981-12-31031 December 1981 Final Deficiency Rept Re Mfg Defects in Lower Subassembly of Biological Shield,Initially Reported on 810915.Conditions Not Considered Reportable Per 10CFR50.55e ML20039C0791981-12-15015 December 1981 Interim Deficiency Rept Re Swing Check Valves in HPCI & Reactor Core Isolation Cooling Turbine Exhaust Lines, Initially Reported 811117.Manufacturer to Supply Hardware for Field Mod of Unit 1 Valves & to Modify Unit 2 Valves ML20038C6991981-12-0202 December 1981 Interim Deficiency Rept Re Damage to Bellows in Primary Containment,Initially Reported 811104.Damaged Bellows Will Be Replaced.Insp of Other Bellows & Investigation Will Be Completed in Early Jan 1982 ML20038B5101981-11-25025 November 1981 Interim Deficiency Rept Re Effect of Recent Seismic Reanalysis Data on Seismic Qualification of Certain Equipment.Bechtel,Eds Nuclear & Util Conducting Addl Tests to Be Completed by 820615 ML20010C9601981-08-10010 August 1981 Final Deficiency Rept Re Potentially Reportable Const Deficiency Involving Acme Embeds,Initially Reported 810422. Item Found Not Reportable Per 10CFR50.55E ML20009D9211981-07-14014 July 1981 Interim Deficiency Rept,Originally Reported on 801030,re Inadequate Nondestructive Exam of Spool Weld Buildup by Supplier.Vendor Has Completed Pipe Repairs.Indications Found to Be Harmless.Problem No Longer Deemed Reportable ML20008G1261981-06-16016 June 1981 Part 21 Rept Re Potential Problem W/Overcurrent Relays ITE-50H & ITE-50D Series Produced from 1976 to Oct 1980. Relays May Not Drop Out Upon Reduction in Current.Company Taking Steps to Notify Relay Users ML20126L7121981-05-26026 May 1981 Interim Deficiency Rept Re Weld Deficiencies on Acme Steel Engineering Co Embeds,Initially Reported on 810422.Embeds Are Being Visually Inspected.Destructive Testing Program Will Be Completed by 810626 ML19350D3691981-04-0606 April 1981 Significant Const Deficiency Rept,Originally Reported on 810305,re 810304 Discovery of Deformations on Inner Surface of Drywell Shell.Caused by Local Overpressurization During Concrete Placement.Concrete Removed ML19347E1651981-03-0404 March 1981 Interim Deficiency Rept Re Spool Weld Buildup Insufficient Exam,Initially Reported on 801010.One Buildup on Diesel Fuel Tank Vent Line,Previously Thought Inaccessible,Located in Const Joint & Successfully Examined ML20003D0941981-01-27027 January 1981 Final Potential Significant Deficiency Rept Re Pipe SA-155 Kc 70,initially Reported on 801009.Pipe Acceptable as Delivered & Not Reportable Per 10CFR50.55e.Pipe Seam Porosity Repaired ML19350B4201981-01-27027 January 1981 Final Deficiency Rept Re Area Noted on Reactor Pressure Vessel 2 Which Included Porosity & Linear Indications Approx one-inch in Diameter,Initially Reported 791213.Investigation Revealed That Item Is Not Significant Deficiency 1999-06-01
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML18107A3441999-06-0101 June 1999 Interim Part 21 Rept Re Premature Over Voltage Protection Actuation in Circuit Specific Application in Dc Power Supply.Testing & Evaluation Activities Will Be Completed on 990716 ML20137M9261996-10-31031 October 1996 Monthly Indicator Rept ML20076K9941994-10-25025 October 1994 Emergency Plan 1994 Hope Creek Graded Exercise H94-06 ML20064H1071994-03-0909 March 1994 Proposed Changes to QA Program Description ML20127K8811993-01-0606 January 1993 Part 21 Rept Re Engine Driven Fuel Oil Pump Being Returned for Proper Configuration Due to Portion of O Ring Missing from Plug ML17223A3531989-10-13013 October 1989 LER 89-005-00:on 890913,turbine & Reactor Trip Occurred Due to Opening of Breaker CB-3 Inside Reactor Protection Sys Cabinet.Caused by Inadequate Work Order Work Description. Sensitive Sys Procedures Reviewed & revised.W/891013 Ltr ML20128G5101985-05-24024 May 1985 Part 21 Rept Re Heat Numbers to Be Added & Deleted from Sublist Sheet A,Based on Review of NRC ML20096E6611984-08-20020 August 1984 Interim Potential Const Deficiency Rept Re Silicon Controlled Rectifiers in Emergency Diesel Generator Exciters.Initially Reported on 840503.Item Not Reportable Per 10CFR50.55(e) ML20094F5331984-07-18018 July 1984 Interim Part 21/deficiency Rept Re Busses on Colt Industries Diesel Generator Lube Oil Pump Discharge Nozzles.Initially Reported on 840425.Design for Tapered Thread Adapter Changed.Next Rept Expected by 840807 ML20091N9811984-06-0404 June 1984 Interim Part 21 & Const Deficiency Rept Re Ethylene Propylene Seals on Four Gh Bettis Actuators Which May Swell Due to Absorbing Oils from Actuator Lubricant.Initially Reported on 840503.GH Bettis Submitted Part 21 Rept ML20091N8761984-06-0101 June 1984 Interim Part 21 & Deficiency Rept Re Installation of Four Generator Potential Transformer & Basler Electric Exciter Control Panels.Initially Reported on 840503.Problem Subj of Part 21 Rept Submitted to Region III by Basler Electric ML20091N8881984-06-0101 June 1984 Interim Potential Const Deficiency Rept Re 13 Defective GE Hea Relays Due to Malfunction in Trip Force Values.Initially Reported on 840502.Replacement Relays from GE Scheduled for Aug 1984.Next Rept Will Be Submitted by 840921 ML20087M7041984-03-15015 March 1984 Monthly Operating Repts for Feb 1984 ML20081D0081984-02-29029 February 1984 Potentially Significant Const Deficiency Rept Re Defective Capstan Springs in Itt Grinnel Shock Arrestors.Initially Reported on 831024.Condition Does Not Warrant Coming Offline to Replace Springs.Next Rept by 840429 ML20080S4111984-02-24024 February 1984 Part 21 Rept Re Reportable Defects on Certain AKR-30 & AKR-50 Low Voltage Power Circuit Breakers Delivered for Use at Facility.Breakers Currently Under Repair,Reinsp & Recertification ML20080A1201984-01-18018 January 1984 Interim Deficiency Rept Re Failure of GE Type AKR-30 Circuit Breakers to Operate Properly.Initially Reported on 831223. Caused by Inadequate Mechanical Loading of Closing Spring. Investigation in Progress.Next Rept by 840321 ML20079R5061984-01-0606 January 1984 Interim Potential Const Deficiency Rept Re Agastat Time Delay Relays.Initially Reported on 831207.Four Defective Relays Identified.Next Rept by 840125 ML20082R0141983-11-23023 November 1983 Significant Const Deficiency Rept Re Defective Capstan Springs in Itt Grinnell Mechanical Shock Arrestors.Initially Reported on 831024.Springs Will Be Removed or Replaced & NDE Performed.Final Rept Expected by 840229 ML20082B7161983-10-28028 October 1983 Interim Const Deficiency Rept Re Altered Expansion Anchors. Initially Reported on 830816.Former Craft Employee Deliberately Circumvented Expansion Anchor Installation Program.Supports Will Be Reworked ML20076F1631983-08-15015 August 1983 Interim Deficiency Rept Re Heat Treatment of Stainless Steel Flanges.Initially Reported on 830601.Test Results Indicate Safe Operation Not Adversely Affected Had Problem Gone Undetected.Item Not Reportable Per 10CFR50.55(e) ML20072N0891983-06-30030 June 1983 Interim Deficiency Rept Re Possible Lack of Heat Treatment on Stainless Steel Flanges Mfg by Tube-Line Corp.Initially Reported on 830601.Affected Flanges Removed from Svc. Bechtel Providing Analysis.Next Rept by 830815 ML20074A2001983-05-0505 May 1983 Interim Significant Const Deficiency Rept Re Mechanical Shock Arrest or Brackets Supplied by Itt Grinnell W/ Potential Interference Problems.Initially Reported on 830413.Affected Parts Returned to Itt Grinnell for Rework ML20073T3201983-05-0202 May 1983 Significant Const Deficiency Rept Re Weld Defects in Class IE Cabinets.Initially Reported on 830125.Bailey Controls Co Reworked All Affected Cabinets ML20073S1741983-04-28028 April 1983 Deficiency Rept Re Scribed Lines on Small Bore Piping Resulting in Sharp Discontinuities.Initially Reported on 830124.Repairs Will Involve Replacing Pipe,Blending Out Scribe Line or Welding.Completion Expected by 830530 ML20073E1741983-03-31031 March 1983 Significant Const Deficiency Rept Re Use of Incorrect Weld Filler Matl by GE in Root of Welds Connecting Control Rod Drive Housing to Reactor Pressure Vessel Stub Tools. Initially Reported Verbally on 821124 ML20072R2151983-03-21021 March 1983 Interim Significant Const Deficiency Rept Re Use of Fiber Shims,Poor Wiring Practices & Use of Unqualified Electrical Components on Limitorque Valve Operators.Initially Reported on 810619.Defects Will Be Reworked Per Procedure SWP/P-E-18 ML20071F0051983-02-28028 February 1983 Interim Deficiency Rept Re Defective Spot Welds in Four Class IE Termination Cabinet Assemblies.Initially Reported on 830125.Defective Cabinets Reworked by Bailey Controls Co.Final Rept Will Be Submitted by 830430 ML20071C9771983-02-24024 February 1983 Interim Deficiency Rept Re Const of Scribed Lines on Small Bore Piping Used in Gauging Socket Weld Locations.Initially Reported on 830124.Investigation Underway.Final Rept to Be Submitted by 830430 ML20071B5791983-02-15015 February 1983 Significant Const Deficiency Rept Re Emergency Diesel Generators.Initially Reported on 821213.Inadvertent Contamination W/Diesel Fuel by Elastomer Seal (O Ring), Resulted in Binding or Malfunction.Elastomer Seals Removed ML20028G4941983-01-31031 January 1983 Monitoring of Liquefied Natural Gas & Liquefied Petroleum Gas Shipping & Const Activities on DE River. ML20028F4951983-01-18018 January 1983 Interim Deficiency Rept Re Grout Intrusion Into Drywell Airgap.Initially Reported on 820920.Grout Will Be Removed by 830225 ML20028D6611983-01-11011 January 1983 Interim Potential Const Deficiency Rept Re Emergency Diesel Generator O Rings.Initially Reported on 821213.Colt Industries Reported Potential Problem If Cooling Sys Contaminated W/Diesel Fuel.Also Reportable Per Part 21 ML20064F3351982-12-27027 December 1982 Interim Deficiency Rept Re Cracking in Control Rod Driveline Housing Welds Due to Const Error in Root Welds.Initially Reported on 821124.Affected Welds Ground Out,All Weld Metal Removed & Correct Weld Filler Matl Reinstalled ML20069Q2231982-11-29029 November 1982 Deficiency Rept Re Significant Const Deficiency Underestimated Annulus Pressurization Loads.Initially Reported on 821028.Independent Technical Review of Design Calculations Performed ML20065S3161982-10-21021 October 1982 Interim Significant Const Deficiency Rept Re Limitorque Valve Operators.Initially Reported on 810619.Instructions for Operator Insp & Rework Will Be Included in Cable Termination Work Procedure Scheduled for Issuance by 821231 ML20065S2771982-10-20020 October 1982 Interim Deficiency Rept Re Grout Intrusion Into Drywell Airgap.Initially Reported on 820920.Fiberoptics Used for Identification,Map Intrusion & Laitance.Hydrolaser Removal of Grout Intrusions & Other Removal Methods Researched ML20069F6821982-09-15015 September 1982 Final Significant Const Deficiency Rept Re Corrosion Inhibitor Effects on Solder Used to Stake Locking Nuts on Thermostatic Valve Override Assemblies.Initially Reported on 820702.Locking Nuts Fitted W/Swaged Locking by 821126 ML20063B8191982-08-13013 August 1982 Final Significant Const Deficiency Rept Re Torque Values of Stud to Nut Combinations Securing Spider Assembly in Diesel Generator.Initially Reported on 820514.Matter Not Reportable Per 10CFR50.55(e) ML20062H3221982-08-0202 August 1982 Interim Deficiency Rept Re Deleterious Effects Corrosion Inhibitors Have on Solder Used to Stake Locking Nuts on Thermostatic Valve Override Assemblies.Initially Reported on 820702.Final Rept Expected by 820924 ML20058J0401982-07-29029 July 1982 Interim Significant Const Deficiency Rept Re Hpci/Reactor Core Isolation Cooling Exhaust Check Valves.Initially Reported on 811117.Bechtel Analysis Indicates Potential Valve Failure.Next Rept Expected 820915 ML20054M1121982-06-15015 June 1982 Monthly Operating Summary Repts for May 1982 ML20054J2001982-06-11011 June 1982 Final Deficiency Rept Re Auxiliary Bldg Seismic Analysis. Results of Oct 1981 Auxiliary Bldg Seismic Analysis Inconsistent w/1975 Analysis.Caused by Methodological Difference.Revised Spectra Curves to Be Used for Equipment ML20054J3321982-06-10010 June 1982 Interim Deficiency Rept Re Diesel Generator Bolt Torquing, Initially Reported on 820514.Verification of Requisite Torque Valves on Generator S/N 700510R1 Pending Availability of Manufacturer Representatives ML20054C4691982-04-0101 April 1982 Part 21 Rept Re Hma Relays W/Contact Leads Not Fully Insulated,Initially Reported 810708.No Operating BWRs Utilize Subj Hma Relays.All Potential Problems Will Be Corrected Before Startup ML20040B4391982-01-11011 January 1982 Final Deficiency Rept Re Damaged Bellows Assembly,Initially Reported 811104.Apparently Caused by Electrical Arcing.No Repair or Rework Contemplated Due to Facility Cancellation ML20040B2081981-12-31031 December 1981 Final Deficiency Rept Re Mfg Defects in Lower Subassembly of Biological Shield,Initially Reported on 810915.Conditions Not Considered Reportable Per 10CFR50.55e ML20039C0791981-12-15015 December 1981 Interim Deficiency Rept Re Swing Check Valves in HPCI & Reactor Core Isolation Cooling Turbine Exhaust Lines, Initially Reported 811117.Manufacturer to Supply Hardware for Field Mod of Unit 1 Valves & to Modify Unit 2 Valves ML20038C6991981-12-0202 December 1981 Interim Deficiency Rept Re Damage to Bellows in Primary Containment,Initially Reported 811104.Damaged Bellows Will Be Replaced.Insp of Other Bellows & Investigation Will Be Completed in Early Jan 1982 ML20038B5101981-11-25025 November 1981 Interim Deficiency Rept Re Effect of Recent Seismic Reanalysis Data on Seismic Qualification of Certain Equipment.Bechtel,Eds Nuclear & Util Conducting Addl Tests to Be Completed by 820615 ML20010C9601981-08-10010 August 1981 Final Deficiency Rept Re Potentially Reportable Const Deficiency Involving Acme Embeds,Initially Reported 810422. Item Found Not Reportable Per 10CFR50.55E 1999-06-01
[Table view] |
Text
.
^
/
Thomas J. Martin Pubhc Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 201/4304316 vice Presdent Mailing Address: P.O. Box 570, Newa rk , N.J. 07101 E ngineering ard Construction December 31, 1981 Mr. R. C. Haynes, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement O Region 1 j{ {f. d[j l, 631 Park Avenue j3 King of Prussia, Pennsylvania 19406 [sp
q qf ,\
i
.p D',L
, \
Dear Mr. Haynes:
e}> d
- v POTENTIAL SIGNIFICANT CONSTRUCTION DEFICIENCY N' BIOLOGICAL SHIELD MANUFACTURING DEFECTS 4 /
NO. 2 UNIT (50-355) ./,'
HOPE CREEK GENERATING STATION
' /
On September 15, 1981, a verbal report was made to Region 1, Office of Inspection and Enforcement representative, M r. S.
Chardha ry , advising of a potential significant construction deficiency concerning manufacturing defects in the lower subassembly of the Unit #2 biological shield. The item was manufactured by PX Engineering Company of Woburn, Ma s sa chu-setts. On October 8, 1981, an interim report was submitted which outlined investigative and corrective steps initiated by PSE&G.
The following are the results of these actions. The infor-mation is correlated to match the description of deficiency in our October 8, 1981 letter. No additional defects were identified by reinspection.
- 1. Engineering Evaluation a) & b) - Undersize fillet welds and insufficient pro-jection of penetration sleeves: It has been
' determined that the existing conditions meet the design requirements because an adequate design margin exists to accommodate the loading.
c) - Shear Tie Bolts Not Stamped: Based on docu-mentation (CMTR's) provided by the Supplier, the shear tie bolts meet specification requirements.
8201250269 811231 PDR ADOCK 05000355 S PDR O
c Mr. R. C. Haynes 12/31/81 d) - Portion of Full Penetration Weld Omitted:
Based on Engineering evaluation, the existing conditions meet the design requirements be-cause an adequate design margin exists to ac-commodate the loading. However, when field welds are to be accomplished on the unit, the vertical weld will be completed to agree with original design configuration.
e) & f) - Linear Indications in the Corners of Anchor Bolt Hole Windows and Added Welds Not Shown on Design Drawings: The welds at the corners of bolt inspection windows are construction aids only to facilitate welding of the closure plates. However, the indications will be re- 1 moved and the welds repaired.
g) - Gaps Between the Inside Surface of tne Outer Shell and the Type III H&V Penetrations:
These gaps have been determined to have an in-significant impact on the structural integrity of the penetrations, because an adequate mar-gin exists to accommodate the loading. How-ever, when field welds are to be acccmplished, the leg size of all fillet welds used on outer shell to H&V penetrations will be increased, which will restore the effective weld leg size to original design.
- 2. Based on Engineering evaluation of the noted deficien-cies, it is concluded that the conditions would not have adversely affected safe operation of the plant had they gone uncorrected. Therefore, none of the conditions are considcred reportable in accordance with 10CFR50.55(e).
Please cancel this item as a potential significant defi-ciency. Should you have any further questions, we will be pleased to discuss them with you.
Very truly yours, lg CC: Office of Inspection and Enforcement Division of Reactor Construction Inspection Washington, D. C.
NRC Resident Inspector - Hope Creek P.O. Box 241 Hancocks Bridge, N.J. 08038