Deficiency Rept Re Significant Const Deficiency Underestimated Annulus Pressurization Loads.Initially Reported on 821028.Independent Technical Review of Design Calculations Performed
ML20069Q223
Person / Time
Site: Hope Creek  PSEG icon.png
Issue date: 11/29/1982
From: Martin T
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8212080502
Download: ML20069Q223 (2)


Text

.

T.':

Thomas J. Martin Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 2J1/4306316 Vice Pradet Engineering ard Construction November 29, 1982 Mr. Ronald C. Haynes, Administrator U.

S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Haynes:

SIGNIFICANT CONSTRUCTION DEFICIENCY l

UNDERESTIMATED ANNULUS PRESSURIZATION LOADS HOPE CREEK GENERATING STATION On October 28, 1982, a vorbal report was made to Region I, Office of Inspection and Enforcement representative, Mr. L. Norrholm, advising of a potentially significant construction deficiency concerning annulus pressurization loads higher than previously calculated.

The following report is'provided in accordance with the requirements of 10CFR50.55 (e).

As a part of the analysis needed to address the NRC's generic concern regarding asymetrical loads on the Reactor Pressure Vessel (RPV) due to pipe breaks at the vessel nozzles, Bechtel in January, 1979 calculated the recirculation outlet line break mass release rate based on a 50/50% (annulus /drywell) flow split.

Thicalcula-s tion also generated the force-time histories which were subsequently l

transmitted to General Electric and used to determine annulus pressurization (AP) response spectra at various locations, to include the RPV and RPV internals.

Using the AP response spectra, GE analyzed the loads imposed on the RPV, RPV internals and GE supplied piping attached to the vessel.

Consequently, several design modifications were implemented l

to accommodate these loads.

During preparation of the Hope Creek FSAR, Bechtel identified an error in the manner in which they had applied the GE methodology for calculating the mass release rate for the recirculation out-let line break in their analysis of January, 1979, which resulted in underestimation of the AP loads.

8212080502 821129 PDR ADOCK 05000354 A,1/q S

PDR

'7

'.. e R.

C.

Haynes 2

11/29/82 If the error had gone undetected and if the postulated AP event occurred, vibratory loads on the RPV, RPV internals and surrounding structures would have been higher and in some cases could have caused stresses to exceed the design parameters.

This could have adversely affected safe shutdown of the plant through possible impairment.to the control rod drive and/or ECCS systems.

This deficiency is therefore determined reportable in accordance with 10CPR50.55(e).

Bechtel is incorporating a design modification to provide a flow diverter for the recirculation system outlet which will only allow 25% cf the flow into the annulus as compared with the 50% assumed in January, 1979.

Correctly applying GE's mass relief rate methodology, Bechtel recalculated the force-time histories based on the 25/75% flow split.

The revised force-time histories and loads were compared with the 1979 histories and loads to ensure that the intended design modification results in lower forces on the RPV and bioshield.

Evaluation of the combined effect shows the forces are lower for the revised loads, except locally at the flow diverter attachment.

Consequently, GE and Bechtel have concluded that the use of the previously generated AP response spectra is conservative for the Hope Creek plant given the flow split of 25/75%.

An independent technical review of design calculations generated by the Engineering Group involved has been performed to ensure that similar errors do not exist.

Based on the results of this review we conclude that this was an isolated occurrence and, consequently, no procedural changes are considered necessary to prevent recurrence.