Text

1

. 6 8 0 0 4 2y03 fl 716 Liney auilding April 24, 1930 Mr. Janam P. O'2ailly, Director U.S. Nuclear Regulatory Cornission Office of Inspection and Enforcanent Region II 101 Ifariatta Strset, Suite 3100 Atlanta, Georgia 303J3

Dear !!r. O'Ra'111y:

TENNESSEE VEI.ET AUTdCRITY - S;QUOTAH UCCLEAR PLXIT UNIT 1 - DCCKET NO.30-327 - 7ACILIrf DPERXIING LICEN33 DF:1 REFCRTA3LE OCCU22INCr.

REPO?.T SqFA-50-327/3028 The enclosed report providea details concerning the nonconformance of main stems proosure transmitters which lack. the environmental qualifications to o;,erate for an extended period of tine following a hi3 n enorgy line braak. This report is sulnaitted in accordance with Sequoyah unit 1 Technical Specification 6.9.1.12.1.

Very truly yours, l

TE:CIESSi2 VALLE7 ETdcaITY l J. R. Calhoun Director of Nuclear Power 1

Enclosure (3) cc (Zaclosure): l Director (3)  :

Office of Management Infor=ation and Program Control I U.S. Nuclear Reguistory Connaission Usshington, DC 20333 Director (40)

Office of Inspection and Enforcement U.S. Uuclear Retulatory Cowfasion

. ashington, DC 20535 Mr. Dill Lavallee Nuclear Safety Analysis Center Palo Alto, Califernia 94303 lir. W. T. Cottle, h2C Inapector, Sequoyah k

.