r rrHe m, o s '.uc t t u. m u t c T o w C; v <w.

LICENSE E L's t.? t _-uT contact atocx []_ l l l

@ P LE ASE F H e N T OR T YPE At L H L Q ulH E D IV O n'.uTIONI

' l~-]

> e <

]D C CjNj2 p 0f0 tur m coot la is 0 0 to se -

0 l 9 ' 0 J - l 0a [0j@l t- x 4 il [1 illlj@[_ wa@

um t T,eE & '

l

,'T y g" l L }g 0 l 5 ] l 0 l 0 l 3 l 1 l 8 l]0 r; l 2 E VENT 0 l 4 l 7 l 9 J@LO 14 IS l 0 ICl ATE 7 l 3hEPLnT 9l@ JU b 60 61 .* . T '. s W E R fL DATE EVENT DESCRIPTION AND PRCB ARLE CONSEQUENCtES h p JT] l At 0540 during the perforrance of routine surveillance testina it was dis- _ ]

g ; covered that the CEA ration inhibit failed to actuate within 7.5 inches _j o , [ deviation between CEA's as required by T.S. 3.1.3.1. All CEA's were fully I

o;3; ; withdrawn and the CEA drive system was maintained in manual or off during l

[o y lthe event. CEA motion inhibit was returned to service at 1410 on February I jol,l l6, 1979. LERs77-100 (U-1) and 78-30 (U-2) describe similar events. 1 I

l f ola i L 80 I

7 8 9

, SYST E M CAUSE C A USE COVP. VALVE CODE CODE SUSCODE COWCNENT CODE SUSCODE SUSCODE o 9 l R l B !@ [E_j@ l A l@ l I l N l S l T l R I U I8 LcJ@ LLJ @

7 8 9 10 11 12 13 18 19 20 t

SE QUE N TI AL OCCUR R[ NC[ HEFJHT R E VISION LE _ EVENT YE AR R E FOR T NO. CODE TYPE N O.

j O ,,g;RgHO 21 7 9] 22 l-l 23 lOl016 24 26 l/

27 1013i 2F 29 30 LI 31

-l Lo_J 32 ACTION FUTURE EFFECT SWUTDOWN ATTACHYENT N P R D-4 FalVE CDYP. COYPONENT 1

TAKEN ACTION ON PL ANT YETHOD HOURS SUBYl T T E D FORMSUB. SUPPLIER M ANUF ACTLRER lA JJ lgl34A lg [5 3

Zj@ W@

36 l0l0l0l 31 l

40 l41 Y l@ lNl@

42 lNl@

43 44 Ml2l8lSl@ 47 CAUSE DESCRIPltON AND CORRECTIVE ACTION 3 h i O lThe CEA motion inhibit failure was due to a t ad K2 relay on the relay card I i i lfor the 8 inch aroun deviation portion of CMI. See attached _shoet for I i , additional details. I 1

3_ l lil_4__] I I i 7 8 9 80 ST s  % PL AER OTHE R ST ATUS SCO i DISCOVERY DE SCRIPTION i s y @ l0l9l8 @l NA l lBl@l Onerator observation l 7 F 9 10 12 Il 44 45 46 80 A C T IVi rY CON T E NT RE ED F AMOUNT O AC Ti t i T Y - L OC ATION OF RE LE ASE 7 8 9 10 11 44 45 BU PERSONNE L f APOSUM ES NLYHE A TYPF OE SCHiP TION 39 r

3 7 8 9 10 10 0l@lzl@l 13 N l 7 11 12 80 FF HSONNE L INJUHIES NueBER Of SCHIPIlON lilsI1010 8 9 0 l@l 12 NA l 7 11 80 t OES OF CH D AVAGE TO F ACILITY .

TvPE DE SCRIP T ION *

[1[9.](ZJ@l 7 b 9 10 NA 80 l

P L!B E iCIT Y NHC USE ONLY te e -( p DE SCHtP T ION l2lOl' '

s  !  ! k 7 8 9 10 68 69 80 %

  • * * * ~

N E OF FHEPARER PHONE-

LER 79-06/3L DOCKET NO. 50-318 EVENT DATE 2/04/79 REPORT DATE 3/01/79 ATTACHMENT CAUSE DESCRIPTIO?, '

CORRECTIVE ACTIONS: (CONTINUED)

The CEA motion inhibit failure was due to a bad K2 relay on the relay card for the 8 inch group deviation portion of CMI. The relay was replaced and CMI returned to service. This was detennired to be a natural end of life failure. For several weeks prior to this event there had been numerous spurious actuations of a faulty reed switch on control rod 21. These resulted spurious group deviation alarms, eventually wearing out the contacts of the -

K2 relay. Rod 21 has been positioned by plant operators so as to minimize these spurious alarms. The reed switch stack for rod 21 will be replaced during the next refueling outage.

\

O