ML19281A270

From kanterella
Jump to navigation Jump to search
Forwards LER 79-006/03L-0
Date released: 10/22/2019 Download: ML19281A270


LER 79-006/03L-0 on 790204:control Element Assembly Motion Inhibit Failed to Actuate within Tech Spec Limits.Caused by Bad K2 Relay on Relay Card.Relay Replaced & Inhibit Returned to Svc
ML19281A272
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 03/01/1979
From: Davis S, Miernicki M
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19281A272 (2)
Forwards LER 79-006/03L-0
ML19281A269
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 03/01/1979
From: Russell L
BALTIMORE GAS & ELECTRIC CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19281A269 (1)