LICENSEE EVENT REPORT

  • CONTROL ULOCK: l l l l l (PLEASE PRINT On TYPE ALL REQUIRED INFORMATION) 7 o i 8 9 inlalejP ls11 l@!0l0101010101010101010l@l4l1l1l1l1l@l 14 15 LICLNSE NUMbLH 26 l

l@

LICE NLEL CODE 26 LICEN5L 1)PE JO b/ LAI bd CON'T lolij 7 8 R

3gO" n 00 Lj@0l5 l 0l -l 0] 219 61 368l@l03 0 l 8LVENTl 2 DATEl 6 ] 7 l 914l@l73 0 l 9REPORT l 1 lDAT 4 El 7 l 980l@

DOCKET NUMUER EVENT DESCRIPTION AND PROB ADLE CONSEQUENCES h o 7 l On Augist 26, 1979 at 0912 the drive belt on the reactor coolant leak detection l g 3 g air sampling system (Panel C-19) was found broken.

l o 4 l l lo isi i l

~

o o I l 1o171 ' -

1 O R l I 7 8 9 80 DE CODE SUDC E COMPONENT CODE SUSC DE SU E loIol 7 8 I cl 1l@ l El@ l x l@ Iz lz Iz l zl zl zlg l z @ l zl@

9 10 11 12 13 18 19 N

,_ SEQUE NTI AL OCCURRENCE REFORT REVISION LE R /RO EVENT YEAR REPORT NO. CODE TYPE NO.

h nEPOni l7 l9 l l-l l0 l3 5l l/l l 0l 3l lLl l- l0 l

_ 26 22 23 24 26 27 28 29 Ju 31 32 AKEN ACT N ON PLANT T4 0 HOUdS SB 1 FOR ib B. SUPPLIE I M/N fACTURER W

33

@(7j @ 34 lzl@

35 Wh 36 l 0 10 l 0 0l 3/ 40 W@

41 d@ Iz @

42 43 l Nl 3l 0l 547 @

44 CAUSE DCtCRIPTION AND CORRECTIVE ACTIONS h i oil The drive system sheares were fot nd misaligned. This caused the drive belt to wear I lil(; j andevenkuallybreak. The sheaves were realigned, e new bel t installed and the I j,;7gl system returned to normal on August 28, 1979. I i a l l i 4 l . I 7 8 9 80 ST S r THER STATUS 15 V RY DISCOVERY DESCRIPTION i 5 8

l l@l0* '

POTR j 0lgl N.A.

l l A lgl Operational Event l

A 11VITY CO TENT RELEASED OF RELE ASE AYOUNT OF ACTIVITY LOCATION OF RELEASC i G l z l @ lz l@l N.A. l l N.A. l PERSONNEL E XPOS ES NUMBER Q O .

[TJT]

l 0 ] 0 l 0 lhlzl TYPE @l DESCRIPTION N.A. QQ] l PERSONNELINJU IES NUMBE R DESCRIPTION ~

i a l0l010lhl N.A. o. k _. _J l

^"

ofSC Pi ON ' ^'" ' " @

7 9, Q g$/

7 8 9 to 80 ISSUf 7

2 o a o I N lhl E CRIPTION N.A. nhillllll lill!I io , /q o.s) to no r, John M. Fulton '~

617-746-7900 .o *-

NAME OF PREPAHER PHONE-

. -