~~Entergy INSERVICE INSPECTION

SUMMARY

REPORT FOR REFUEL OUTAGE 12 AT PILGRIM NUCLEAR POWER STATION MAY 1999 Prepared by A

Date i T TT Reviewed by

/

//

Date 4,9 7 4 Approved by Date

~77 V

g,y2;gg ggg6g3

l s,.

)

l Table of Contents 1.0 Executive Summary 1.1 Tables Table 1 ISI Examinations Performed On-Line Prior to RFO#12 Table 2 ISI Examinations Perfonned During RFO#12 Table 3 RF012 Nonconformance Reports Table 4 Preservice Visual Exams Performed During 1999 Table 5 Miscellaneous Visual Exams Performed During 1999 Table 6 Preservice Visual Exams Performed During 1998 Table 7 Miscellaneous Visual Exams Pefformed During 1998 Table 8 Preservice Visual Exams Performed During 1997 Post RFO#11 Table 9 Miscellaneous Visual Exams Performed During 1997 Post RFO#11 Table 10 RFO#12 Flow-Assisted Corrosion Examinations Table 11 RFO#12 and On-Line ISI Maintenance Requests 2.0 NIS-1 and NIS-2 Code Reports for ASME XI Repairs and Replacements 3.0 Data and Vendor Reports (on file at Pilgrim) l 3.1 General Electric Co. Final Report ofInservice Examinations at Pilgrim l

Station during Refueling Outage 12 (3 volumes) 3.2 General Electric Co. Final Report ofInvessel Examinations at Pilgrim

. Station during Refueling Outage 12 (1 volume) 3.3 Pilgrim Generated Data Reports (1 Volume) page 2 of 20

1.0 EXECUTIVE

SUMMARY

This report documents the inservice inspection (ISI), preservice inspection (PSI) and augmented examinations performed at Pilgrim Nuclear Power Station (PNPS) for the period from the end of Refueling Outage 11 to the end of Refueling Outage 12. The examinations performed for ASME Section XI code categories B-D, B-F, B-J and B-K-1 l

are included in the 'first period of the Third Ten Year Inspection Interval of the PNPS ISI Program. Examinations performed for all cier code categories are included as part of the second period of the third inspection interval.

Pilgrim NPS was owned by Boston Edison Company (BECo) during the performance of j

these examinations. Plant ownership was transferred to Entergy Nuclear Generation Company of Plymouth, Massachusetts on July 13,1999.

Tvnes of examinations nerformed:

ASME XI inservice and preservice visual, surface and volumetric examinations of piping, bolting, valves and supports.

. ASME XI subsection IWE visual and ultrasonic examinations of containment per procedure QA 20.03. The General Visual Walkdown of primary containment per procedure PNPS 2.1.8.7 was also performed.

Augmented ultrasonic (UT) examinations for intergranular stress corrosion cracking (IGSCC) per Generic Letter 88-01.

Augmented UT examinations of high energy piping for flow-assisted corrosion (FAC) per Generic Letter 89-08 and Specification M-577.

Visual and ultrasonic examination ofinvessel Core Spray piping in accordance with

BWRVIP guidelines, in addition to various other invessel visual examinations.

Ultrasonic examination of twenty jet pump beams

.. Augmented UT examinations of Salt Service Water piping spools in accordance with Specification M-591 (Generic Letter 89-13).

Augmented UT examinations of moderate energy piping for flow-assisted corrosion per Specificaton M-619.

System pressure tests for ISI Class 2 and 3 piping for the first period of the Third IntervalISI Program.

page 3 of 20-u

'o Examination Details Piping, bolting and valve examinations were conducted in accordance with ASME Section XI 1989 edition, Code Case N-491 for supports and BECo letters to NRC nos.

l 99.035 and 99.066, and NRC letter to BECo 99.063. Letter 99.035 provided the scope of the on line and RFO#12 examinations. Letter 99.066 provided notification of the deferral l

of two Recirc piping weld examinations to the next refueling outage due to a previously l

undocumented interference. Letter 99.063 granted a reduction ofGeneric Letter 88-01 l

inspection frequency for IGSCC Category D nozzle-to-safe end welds from 50% every l

outage to 25% every outage. Containment examinations were performed in accordance with ASME XI 1992 edition with 1992 Addenda subsection IWE as modified by the Code of Federal Regulations. General Electric Company (GE) was the vendor for examinations performed during the refueling outage, while Boston Edison Quality Control personnel performed the on-line examinations prior to RFO#12.

Regarding BECo letter 99.035," PILGRIM 1999 ON-LINE AND RFO#12 ISI PLAN":

All examinations were completed with the following exceptions:

._lS1 WELD No.

System Comments EB-23-F66 HPCI re-scheduled from RF012 to RFOl3 due to location 2R-NI B-1 RECIRC deleted from RF012 due to GL88-01 HWC relief per letter 99.063 2R-N2D-1 RECIRC deleted from RF012 due to GL88-01 HWC relief per letter 99.063 2R-N2E-1 RECIRC deleted from RFO12 due to GL88-01 HWC reliefper letter 99.063 2R-N2F-1 RECIRC deleted from RF012 due to GL88-01 HWC relief per letter 99.063 2R-N2J-l RECIRC deleted from RF012 due to GL88-01 HWC relief per letter 99.063 2-PN-201 A RECIRC deleted from program due to Recirc pump configuration 2R-NI A-9 RECIRC snubber clamp interference; deferred to RFO#13 per letter 99.066 2R-NIB-11 RECIRC snubber clamp interference; deferred to RFO#13 per letter 99.066 GB-10-18-4C RHR substituted weld GB-10-18-4E due to <90% UT coverage HB-10-F145 RHR substituted weld HB-10-6-3B in ISI Program GB-10 14-3D-I RHR substituted weld GB-10-14-F173 due to UT coverage issue 4

A total of 17 Nonconfonnance Reports were issued and are tabulated in Table 3.

A total of 68 ultrasonic examinations for flow-assisted corrosion effects were performed in accordance with Generic Letter 89-08. One Nonconformance Report and six Problem Reports were written to document reduced wall thickness. All components with reduced wall thickness were analyzed and found acceptable for at least one more cycle of operation.

Ultrasonic wall thickness examinations were performed on eighteen rubber-lined carbon l

steel Salt Service Water (SSW) pipe spools in accordance with Specification M-591 and Generic Letter 8913. Remote visual examination of buried 'A' loop SSW system piping revealed areas with missing and degraded rubber lining as documented on Problem l

page 4 of 20 o

Report 99-9207. The inspection was expanded to include buried 'B' loop piping where similar conditions were detected. All degraded conditions were restored and two buried spools were replaced. A total of 21 pipe spools, including the buried spools, were replaced as part of the SSW Pipe Replacement Project during RFO#12.

Three augmented UT examinations of moderate energy piping for flow-assisted corrosion were performed on-line per Specificaton M-619 prior to RFO#12. No degraded conditions were detected. The remainir.g scope of moderate energy piping examinations will be performed during Cycle 13.

Fifty-two system pressure tests for ISI Class 2 and 3 piping were conducted for the first period of the Third Interval ISI Program.

In Vessel Examinations The report of the activities for in-vessel examinations has been provided to the BWRVIP database maintained by EPRI. A summary of the results is provided here:

All examinations cited in BECo letter 99.035 were completed.

Core Spray P8b welds with reported flaws from RFO 1I were re-inspected and the flaws are now attributed to geometry.

All Core Spray P9 welds were examined with no indications fotmd.

Three Core Spray P5 welds that had reported indications in RFO 11 were re-inspected.

One of these is attributed to geometry, one shows no growth, and one indication grew (NCR 99-91) but was found acceptable, i

The shroud vertical welds were visually examined (EVT-1). The goal to achieve coverage of 50% of total weld length was not achieved by a small margin.

All twenty jet pump beams were ultrasonically examined in accordance with current BWRVIP guidelines.

Thejet pump set screw gaps were measured, compared to RFO 11 values, and documented on NCR 99-88. NCR 99-83 documented lack of contact of the wedge with jet pump #16. The canditions were found to be acceptable for continued operation.

The RPV steam dryer had reported indications of erosion (NCR99-71) which were attributed to a hard crud build-up. The deposits were removed.

page 5 of 20

n q

j Containment Examinations (IWE)

Augmented and program examinations were performed as baseline examinations for the containment IWE examination program in accordance with PNPS procedure QA 20.03 and ASME XI 1992 edition with 1992 Addenda as modified by the Code of Federal Regulations.

The General. Visual Walkdown of primary containment was completed in accordance with PNPS procedure 2.1.8.7 with results documented on Problem Report 99-1145. The l

conditions were found to be acceptable with corrective actions not necessary.

Augmented containment downcomer vent examinations were completed and were the

. subject of NCRs 99-65 and 99-74. Pitting caused by galvanic corrosion which violated minimum wall thickness was reported and evaluated. The evaluation found acceptable thickness remained. Selected areas were recoated to prevent further wall loss. The ~

inspection scope was expanded to include all eight downcomer vents.

- As part of the Augmented Program, the junction of the drywell concrete floor-to-drywell inner surface at the 9 foot elevation was examined for conditions which may allow water i

intrusion (moisture barrier). The examination was documented on NCR 99-50. There is no seal material, nor is a neal specified for the location. As part of the evaluation, three of the areas were selected to have the concrete removed and ultrasonic thickness measurements performed on the drywell wall. In all cases the drywell met originally specified values for wall thickness. The entirejunction was examined completing scope expansion requirements.

. All drywell head bolting was examined and conditions reported on NCR 99-89. The bolting was found acceptable with recommendations for procedural changes regarding lubrication.

Bolting for torus hatch X'-200B was examined and conditions reported on NCR 99-81.

The deformation was not in the area of engagement and was merely a flattening of the i

crowns. No further action was taken.

Examination of the bolting on one of eight Gibbs manways resulted in NCR. 99-73 due to severe thread damage. The Gibbs manways are small, outward-pushing drywell hatches that provide access to the drywell upper stabilizer assemblies. The inspection scope was

)

expanded to include all eight assemblies which revealed further nonconformances, subsequen@ recorded on NCR 99-80. The condition was determined to have been caused

. during original construction and was evaluated as acceptable since the affected bolting is 4

not stressed when the safety function is required.

page 6 of 20

TABLEI ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO#12 by Boston Edison Co.

~

W255mnhviwremf5 M5_=i=ONAN CAMR0lWAWSYSWE

--- - LE!?W l

14-VB-1400-258 VALVE BOLTING B-G 2 CS 1S1-1-14-1 VT-1 13 VB-1301-49 VALVE BOLTING B-G-2 RCIC 1S11131 VT-1 12-VB-120181 VALVE BOLTING B-G 2 RWCU 1S1-1-12-2 VT-1 Ill-14-F4 NOZZLE TO PIPE C-F-2 CS ISI-1-14-2A MT UT HB-23-2 Ill FLANGE TO PIPE C-F-2 HPCI 1S1-I 23 3 MT HB-23-F75 FIPE TO TEE C-F-2 HPCI ISI-I-23-3 MT UT HB 23-F87 REDUCER TO PIPE C-F-2 HPCI ISI1-23-3 MT UT llL-23-F67 PIPE TO NOZZLE C-F-2 HPCI ISI-I-23-3 MT UT HL-13-2-3C ELBOW TO PIPE C-F-2 RCIC 1S1-1-13-3 MT UT GB-10-18-4E PIPE TO REDUCER C-F-2 RHR ISI-1-10-3 A MT UT GB-10-F124 PUMP TO PIPE C-F-2 RHR ISI-I 10-3 A MT UT GB-10-F129R PIPE TO HX C-F-2 RHR ISI-1 10-3 A MT UT GB 10-F167 PUMP TO PIPE C F-2 RHR 1S1-1 10-3B MT UT GB 10-F171 ELBOW TO VALVE C-F-2 RilR 1S1-1-10-3B MT UT GB-10-Fl73 PIPE TO VALVE C-F-2 RHR ISI I 10 3B MT UT GB 10-Fl77 PIPE (HX)TO PIPE C-F-2 RHR ISI I 10-3B MT UT HB-10-6-3 B PIPE TO FLANGE C-F-2 L

ISI 1-10-2B MT UT llL-10-F100 NOZZLE TO PIPE C-F-2 RHR ISI-1 10-2B MT UT HL-10-F136 ELBOW TO VALVE C-F-2 RHR 1S1-1 10-2B MT UT llE-30-130PS STANCHION D-B RBCCW 151-1-30-1S111 VT 3 IIE-30-131PS STANCFIlON D-B RBCCW ISI-1-30-ISH I VT-3 IIE-30-1324HL HANGER LUG D-B RBCCW ISI-I 30-ISHI VT-3 HE-30-l HL llANGER LUG D-B RBCCW ISI-t-30-2SH2 VT-3 ilE-30-285HL HANGER LUG D-B RBCCW ISI-I 30-ISHI VT-3 HE-30-294PS STANCHION D-B RBCCW 1S1-1-3 0-1S111 VT-3 HE-30-30HL HANGER LUG D-B RBCCW ISI-I-30-2SH2 VT-3 HE-30-3611L HANGER LUG D-B RBCCW ISI-I-30-I SH2 VT-3 HE-30-37HL(4)

HANGER LUGS D-B RBCCW ISI-1-30-1SH2 VT-3 HE 30-41HL(4)

HANGER LUGS D-B RBCCW 1S1-I-30-1SH2 VT-3 HE-30-42HL HANGER LUG D-B RBCCW ISI-I-30-ISH2 VT-3 IWE-TORUS-LOWER-B1 AUGMENTED TORUS UT clev.-

E-C CONT ISI lWE-AUG-1 UT lifl 6in BAY l IWE-TORUS-LOWER-Bl3 AUGMENTED TORUS UT clev.-

E-C CONT ISI-!WE-AUG-1 UT lift 6in BAY 13 IWE-TORUS-LOWER-B5 AUGMENTED TORUS UT elev..

E-C CONT ISI-lWE-AUG-1 UT lift 6in BAY 5 IWE-TORUS-LOWER-89 AUGMENTED TORUS UT clev.-

E-C CONT ISI !WE-AUG-1 UT lift 6in BAY 9 IWE-TORUS-MWL-Bl AUGMENTED TORUS UT AT F-C CONT ISI lWE-AUG-1 UT MWL BAY I IWE-TORUS-MWL-Bl 3 AUGMENTED TORUS UT AT EC CONT ISI IWE-AUG-1 UT MWL BAY 1:

IWE-TORUS-MWL-85 AUGMENTED TORUS UT AT E-C CONT ISI lWE AUG-1 U I' MWL BAY $

IWE-TORUS-MWL-B9 AUGMENTED TORUS UT AT E-C CONT ISI-lWE-AUG-1 UT MWL BAY 9 page 7 of 20

l TAllLE I (continued)

ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO#12 by Boston Edison Co.

.--- n_.unanamggggpatramaggggger--mmva--e.gsnunsurrogaxAr 11-45 1-4 SPRING liANGER F-A CACS 1S1-1-50-1 VT-3 Il 50-1 TORUSDAYl3 TORUS SUPPORTS F-A CONT Cl A175SHI & Cl A.

VT-3 62-4 11-3-1-21 SPRING HANGER F-A CRD ISI-t-3-1 VT-3 H 3-1-48 RESTRAINT F-A CRD ISI I-3-1 VT-3 j

H-3-1 -49 RESTRAINT F-A CRD 151-I-3-1 VT-3 H-14-1 20S RESTRAINT F-A CS ISI-l 14-2A VT-3 H 141-22 RIGID SUPPORT F-A CS ISI-I-14-2A VT-3 H 14-1-29 SPRING HANGER F-A CS ISI-1-14-2A VT-3 l

11-1 4-1-4 RIGID liANGER FA CS ISI-I-14-2A VT-3 l

H-23-1-21SA ANCilOR F-A HPCI ISI-I-23 5 VT-3 l

i 5I 23-1 30 RIGID HANGER F-A HPCI 1S1-I-23-5 VT-3 H-23 1-33 SPRING H ANGER F-A IIPCI 1S1-1 23-5 VT-3 11 30-1-131 RIGID HANGER F-A RBCCW ISI-I-30-1 Sill VT-3 H.301-135 RIGID HANGER F-A RBCCW ISI-I-30-2SHI VT-3 I

Il 30-1-40SH SPRING HANGER F-A RBCCW ISI-I-30-1SH2 VT-3 H 301-43Sil RIGID HANGER F-A RBCCW ISI I 30-lSH2 VT-3 l

H 30-1-65 RIGID IIANGER FA RBCCW ISI I-30 2 Sill VT-3 j

H-13-1-27 RIGID SUPPORT F-A RCIC 1S11 13 2 VT-3 i

l-29 RIG lANGER R1 R ISI -1 B HI 11 10 1-144 SPRING HANGER F-A RilR ISI-i 10-3 A VT-3 j

11-10-1-197 SPRING HANGER F-A RHR ISI 1-10-4 ASII2 VT-3 l

H-10-1-21SR LATERAL RESTRAINT F-A RHR ISI 1-10-2 A VT-3 j

11 3

S NG {ANrFR

-A RI 11-1-1 I

li-10-1-48SH RIGID HANGER FA RilR 1S1-1 10-1 A VT-3 l

li 10-1-5SS SPRING SUPPORT F-A RHR ISI-1 10-3 A VT-3 H 12-1-45G RIGID RESTRAINT F-A RWCU IS!-I-12 2 VT-3 H 12-1-SSA ANCilOR F-A RWCU 151-1-12-2 VT-3 H-l l-1-32 GUIDE FA SBLC 1S1-!.11-1 VT-3 i

H 29-1-27 RIGID HANGER F-A SSW ISl-1-29-1SH2 VT-3 H-29-1-5 RIGID HANGER FA SSW ISI t-29 ISHI VT-3 l

H 29-1-863 PIPE RESTRAINT F-A SSW ISI-129.lSHI VT-3 l

i page 8 of 20 I

TABLE 2 ISI EXAMINATIONS PERFORMED DURING RFO#12 by General Electric Co.

RPV Ni A-NIR NOZZLE INNER RADIUS B-D RPV 1S11-54-1 UT RPV-N1 A NV NOZZLE TO VESSEL B-D RPV 1S1154-1 UT RPV-N2A-NIR NOZZLE INNER RADIUS B-D RPV 1S1-1-54-1 UT j

RPV-N2A-NV NOZZLE TO VESSEL B-D RPV 1S1-1541 (Jr RPV-N2D-NIR NOZZLE INNER RADIUS B-D RPV 1S1-1-54-1' UT RPV-N2B-NV NOZZLE TO VESSEL B-D RPV ISI I 54-1 UT RPV-N2C-NIR NOZZLE INNER RADIUS B-D RPV ISI-I-54 1 UT RPV-N2C-NV NOZZLE TO VESSEL B-D RPV ISI-I-54-1 UT RPV-N4A-NIR NOZZLE INNER RADIUS & BORE BD RPV ISlI54-1 UT RPV-N4 A-NV NOZZLE TO VESSEL BD RPV ISI I-54-1 UT RPV-N4B-NIR NOZZLE INNER RADIUS & BORE B-D RPV ISI 1-54 1 UT RPV-N4C-NIR NOZZLE INNER RADIUS & BORE BD RPV ISI-154-1 UT RPV-N4D-N!R NOZZLE INNER RADIUS & BORE B-D RPV 1S1-154-1 LTr RPV N9A-NIR NOZZLE INNER RADIUS BD RPV 1S11541 UT RPV-N9A NV NOZZLE TO VESSEL BD RPV ISI-I-54-1 UT 14-A 10A VALVE TO PIPE B-F CS 1S1-1-14-1 UT 14A3 PIPE TO REDUCER B-F CS 1S1114-1 PT UT AUTO 14-B-10A VALVE TO PIPE BF CS 1S1-1 14-1 PT UT 14-B-3 PIPE TO REDUCER BF CS 1S1114-1 PT UT AUTO 14-A-1 SAFE END TO NOZZLE B-F RPV IS1 I 141 UT AUTO 14-B-1 SAFE END TO NOZZLE B-F RPV 1511-14-1 PT UT AUTO 2R-NI A 1 NOZZLE TO SAFE END BF RPV ISI-I 2R-B PT UT AUTO 2R-N2A-1 SAFE END TO NOZZLE B-F RPV ISI I 2R A PT UT AUTO 2R-N2B-1 SAFE END TO NOZZLE B-F RPV ISI-1-2R-A PT UT AUTO 2R-N2C-1 SAFE END TO NOZZLE B-F RPV ISI12R A PT UT AUTO 3II NOZZLE TO CAP B-F RPV ISI I-3-1 UT 6-N4 A-1 SAFE END TO NOZZLE B-F RPV ISI.1-6 1 MT UT 6-N4B-1 SAFE END TO NOZZLE B-F RPV ISI-1-6-1 MT UT 6-N4C-1 SAFE END TO NOZZLE B-F RPV 1S1-1-6-1 MT UT 6 N4D-1 SAFE END TO NOZZLE B-F RPV ISI-I-6-1 MT UT RPV-N16 A-R-1 NOZZLE TO SAFE END B-F RPV 151-1-54-4 PT RPV-N9A-1 NOZZLE TO SAFE END B-F RPV ISI-I-54 4 PT UT 2-PB-201 A PUMP BOLTING B-G-1 RECIRC ISI-I 2R-A UT 2-PB-201 B PUMP BOLTING B-G-1 RECIRC ISI-1-2R-B UT 14.VB-1400-25 A VALVE BOLTING B-G-2 CS 1S1-1 14-1 VT-1 6-VB-58 A VALVE BOLTING B-G-2 FW ISI l-6-1 VT-1 6-VB-58B VALVE BOLTING B-G-2 FW ISI l-6-1 VT-1 1-VB-203-2C VALVE BOLTING <2' B-G-2 MS 1S11 1 1S1(2 VT 1 l-VB-203 2D VALVE BOLTING <2' B-G 2 MS 1S1-111S112 VT-1 1-VB-203-3 A VALVE BOLTING <2' B-G-2 MS 151-1-1-1S111 VT-1 1 VB-203-38 VALVE BOLTING <2' B-G-2 MS ISI-I t ISill VT-1 page 9 of 20

}

TAllLE 2 (continued)

)

ISI EXAMINATIONS PERFORMED DURING RFO#12 by General Electric Co.

I etsar-=nstamuW =-WinNWFCATEGORMSY6MMMGXM*"BllWBdEXAM i

1-VB-203 3C VALVE BOLTING <2' B-G-2 MS ISI-1-1-ISHI VT-l l-VB-203-3D VALVE BOLTING <2' B-G-2 MS ISI-1-1-ISHI VT-l 1-VB-203-4 A VALVE BOLTING <2' B-G 2 MS ISI-1-1-1Stil VT-1 1-VB-203-4B VALVE BOLTING <2' B-G-2 MS 151-1 1-1S111 VT-l 13 VB-130150 VALVE BOLTING B-G 2 RCIC ISI-I-13-1 VT-1 12 VB 12015 VALVE BOLTING B-G-2 RWCU ISI-I-12-l SH I VT-1 12-VB-1201-85 VALVE BOLTING B-G-2 RWCU ISI-I-12-I SH I VT-l 14-A-19 VALVE TO PIPE BJ CS 1S11-14-1 UT 14R-A 16 PENETRATION TO ELBOW B-J CS ISI-I14-1 PT UT 14R-B-16 PENETRATION TO ELBOW B-J CS 1S1-1-14-1 PT UT 14R B-21 A PIPE TO PIPE B-J CS ISI114-1 UT 6-N4A 7 PIPE TO ELBOW B-J FW ISI-I-6-1 MT UT l-A-15 FLUED HEAD TO PIPE B-J MS ISI-I-1-ISH2 MT UT l-A-7 ELBOW TO ELBOW B-J MS ISI-! I-ISHI MT UT l-A-8 ELBOW TO PIPE B-J MS ISI-I l-ISHI MT UT l-A 9 PIPE TO ELBOW B-J MS ISI-1 1-ISHI MT UT l-BR 1 PIPE TO WELDOLET B-J MS ISI-I 1-ISHI MT UT 2R-NI A-10 PIPE TO VALVE BJ RECIRC ISI-I-2R-B PT UT 2R-Ni A-8 ELBOW TO PUMP B-J RECIRC ISI-I-2R-B PT UT 2R N1B-10 ELBOW TO PUMP BJ RECIRC ISI-I 2R-A PT UT 2R NIB-9BC-1 BR CONN TO ELBOW B-J RECIRC ISI-1-2R-A PT UT 10-I A-14 PIPE TO FLUED HEAD BJ RHR 1S11-10-1 PT UT 10-I A-15 VALVE TO PIPE BJ RHR 1S1-1-10-1 PT UT 10R-IA-12 PENETRATION TO ELBOW B-J RHR 1S11-10-1 PT UT 10R-1B-14 PIPE TO FLUED HEAD B-J RHR 151-1-10-1 PT UT 10 RIB-5 VALVE TO ELBOW B-J RHR ISI-I 10-1 PT UT 10R-O-12 ELBOW TO VALVE B-J RHR 1S1-1-10-1 A PT UT 10R-O-6 45 ELBOW TO PIPE B-J RHR ISI-1 10-1 A PT UT 10R-O-7 PIPE TO VALVE B-J RHR 1S11-10-1 A PT UT 10R-O-8 VALVE TO ELBOW B-J RHR 1S1-1-10-1 A PT UT i

10R-O-9 ELBOW TO PIPE B.J RHR 1S1-1 10-1 A PT UT 12-I-26 ELBOW TO PIPE B-J RWCU 151-112-2 UT 12-1-27 PIPE TO ELBOW B-J RWCU ISI-I12-2 UT 12R-O-l P!PE TO SWEEP-O-LET B-J RWCU ISI-112 ISHI PT UT 12R-0-23 ELBOW TO PENETRATION B-J RWCU ISI-I-12-ISHI PT UT I

B-I l-159 PIPE TO VALVE B.J SBLC ISI-1-ll 1 PT B-l l-320 ELBOW TO PIPE BJ SDLC 1S1I-11-1 PT B 11-321 PIPE TO ELBOW B-J SBLC 1S1-1111 PT B-ll-322 ELBOW TO PIPE BJ SBLC 1S1 1-11-1 PT B-11323 PIPE TO ELBOW BJ SBLC ISIt-11-1 PT l-A-8HLl(8)

SUPPORT LUGS B-K 1 MS ISl-1 1-ISH I MT 2R-NID 14HL2(4) 4 H ANGER LUGS B-K 1 RECIRC ISII 2R A PT page 10 of 20

r l

1 l

l TABLE 2 (continued) l l

ISI EXAMINATIONS PERFORMED DURING RFO#12 l

by General Electric Co.

? m N (NESMW%3DESCRIPTI' N4WidN --dVCSTRfElksgatti%gmiiE@iig%44ge5 O

GB 10-174HLi(2)

SUPPORT LUGS C-C RHR ISI-I-10-3B MT llB-10-8311Ll(4)

SUPPORT LUGS C-C RilR IS.-I 10-1B MT DB/DC-14 3001-4-1 PIPE TO PlPE C-F-1 CS ISI-I 14 2B PT UT DB/DC-14 3002-51 ELBOW TO PIPE C-F-l CS ISI-I-14-2 A PT UT DC-14-Fi PIPE TO VALVE C-F 1 CS ISI-114-1 UT DC-14-F31 PIPE TO VALVE C-F-1 CS ISI-I-14-1 PT UT DB/DC-10-3001-2 1 ELBOW TO PIPE C-F-1 R11R ISI-1-10-4BSH I PT UT DB/DC-10-3002-3 3 PIPE TO PIPE C-F 1 RHR ISI 1 10-4ASil2 PT UT DC-10-F10R PIPE TO VALVE C-F-1 RilR ISI-I 10-4BSill PT UT DC-10-F9 PIPE TO VALVE C-F-1 RIIR ISI-I 10-4ASil2 UT IWE-GVWD-01 GENERAL VISUAL WALKDOWN E-A CONT ISI lWE AUG-1 VISUAL IWE-ANNDRN-080 ANNULUS DRAINS (2) AT 80 AZ.

E-C CONT ISI-lWE-AUG 1 VT-2 j

IWE-ANNDRN 170 ANNULUS DRAINS (2) AT 170 AZ.

E-C CONT ISI-IWE-AUG-1 VT-2 IWE-ANNDRN-260 ANNULUS DRAINS (2) AT 260 AZ.

E-C CONT IS!-IWE-AUG 1 VT-2 IWE-ANNDRN-350 ANNULUS DRAINS (2) AT 350 AZ.

E-C CONT ISI lWE-AUG 1 VT-2 IWE-ANNDRN-POST ANNULUS DRAINS - POST E-C CONT ISI IWE-AUG-1 VT-2 DRAINDOWN IWE-LINERDRAINS LINER DRAINS E-C CONT ISI-lWE-AUG-1 VT-2 IWE-SNDCUSil 125 AUGMENTED DRYWELL UT AT 9 E-C CONT ISI lWE-AUG 1 UT FT 125 AZ.

IWE-SNDCUSH 305 AUGMENTED DRYWELL UT AT 9 E-C CONT ISl-lWE-AUG 1 UT FT 305 AZ.

IWE-UPDW-72-252 AUGMENTED DRYWELL UT AT 72 E-C CONT ISI-lWE AUG 1 UT FT 252 AZ.

I IWE-UPDW-83-252 AUGMENTED DRYWELL UT AT 83 E-C CONT ISt.lWE-AUG-1 UT FT 252 AZ.

IWE-UPDW 83 288 AUGMENTED DRYWELL UT AT 83 E-C CONT ISI !WE-AUG-1 UT FT 288 AZ.

!WE-VENT-157 AUGMENTED VENT PIPE AT 157 E-C CONT ISI-lWE-AUG-1 VT-l (2-Sided)

AZ IWE-VENT-202 AUGMENTED VENT PIPE AT 202 E-C CONT ISI-IWE-AUG-1 VT-1 (2-Sided)

AZ l

IWE-VENT-292 AUGMENTED VENT PIPE AT 292 EC CONT ISI lWE-AUG-1 VT-1 (2-Sided) i AZ IWE-VENT-337 AUGMENTED VENT PIPE AT 337 E-C CONT ISI lWE-AUG 1 VT-1 (2-Sided)

AZ IWE-VENT-022 AUGMENTED VENT PIPE AT 022 EC CONT ISI-lWE-AUG-1 VT-1 (2-Sided)

AZ IWE-VENT-067 AUGMENTED VENT PIPE AT 067 E-C CONT ISI lWE-AUG-1 VT-1 (2 Sided)

AZ IWE-VENT-l l2 AUGMENTED VENT PIPE AT 112 E-C CONT ISI-lWE-AUG-1 VT-1 (2 Sided)

AZ IWE-VENT-247 AUGMENTED VENT PIPE AT 247 E-C CONT ISI lWE-AUG-1 VT-1 (2-Sided)

AZ IWE-MB-DW-09 MOISTURE BARRIER AT E-D CONT ISI-lWE-AUG-1 VT-3 DRYWELL 9 FT IWE-CB-DWHEAD CONTAINMENT BOLTING E-G CONT N/A VT-1 (DRYWELL llEAD)

IWE-CD-GIBS 270 CONTAINMENT. BOLTING E-G CONT N/A VT-1 1

page 1I of 20 I

l

I i

l l

TABLE 2 (continued)

ISI EXAMINATIONS PERFORMED DURING RFO#12 by General Electric Co.

lWE-CB-X2000 CONTAINM ENT BOLTING E-G CONT N/A VT 1 IWE-CB-X203A CONTAINMENT BOLTING E-G CONT N/A VT '

IWE-CB-X203B CONTAINMENT BOLTING E-G CONT N/A VT-1 IWE-CD X203C CONTAINMENT DOLTING E-G CONT N/A VT-1 11-4 5-1-1 RIGID HANGER F-A CACS ISI-I-50-1 VT-3 1150-1-270 GIBS DRYWELL STABILIZER F-A CONT ISI !WE-AUG-1 VT-3 H 14-1-15S SNUBBER FA CS ISI-I-14 1 VT-3 H-23-1 75 RIGID HANGER F-A HPCI ISI-1-23 1 VT-3 11 23-1-86 SNUBBER F-A IIPCI ISI-I-23 3 VT-3 II-l 1-HAl SPRING ilANGER F-A MS ISI-1-1-ISH1 VT-3 il l.1-X7A ANCHOR F-A MS ISI-1-1-ISH2 VT-3 H-13-1-7SS RIGID IIANGER F-A RCIC 1S1-1-13-1 VT-3 II-2-1-H l 8 SPRING HANGER F-A RECIRC ISI-1-2R-A VT-3 H-2 1-SS2 SNUBBER

[*-A RECIRC ISI-I 2R-A VT-3 H 2-1-SS20 SNUBBER F-A RECIRC ISI-I-2R-A VT-3 II-2-1 SS21 SNUBBER F-A RECIRC ISI-1-2R A VT-3 Il 21-SS22 SNUBBER F-A RECIRC ISI-I-2R-A VT-3 11 10 1 177 SPRING HANGER F-A RHR 1S1-110 1A VT-3 11-12-1-14 SPRING ilANGER F-A RWCU ISI-I 12-ISHI VT-3 H ll 1-18 GUIDE FA SBLC ISI-I-ll-1 VT-3 H 11 1-19 RIGID 11 ANGER F-A SBLC ISI-111 l VT-3 H il 1-30 GUIDE F-A SBLC 1S1-I 11-1 VT-3 H-20-1-7 GUIDE F-A-CL4 RWCU ISI-I-12-ISH2 VT3 page 12 of 20

f TABLE 3 RFO12 NONCONFORMANCE REPORTS 1

^

l

_j ; ' _ ll l[' _ j '_ L. l j }.[.[ Q:f'}[MfQ}'.,((. [; [.}'[ - '

1}G{lf NCR#9919 Two loose 2" anchor bolt extensions at torus saddle support between bays Rework 19800428 12 & l3 NCR#99-50 Evidence of an original seal now missing, also missing concrete Accept-as-is 19800428 NCR#99-62 Evidence ofleakage between valve upper and lower mounting bolts Accept-as-is 19702743 NCR#99-63 Evidence ofleakage between valve upper and lower mounting bolts Accept as-is 19702743 NCR#9945 Corroded surfaces on containment downcomer vents Rework Coating 19800428 NCR#99-71 RPV steam dryer indications Accept-as-is 19800749 NCR#99-73 Thread damage to 6 of 16 Gibbs manway cover bolts Rework 19800428 NCR#99-74 Pitting of containment downcomer vents Accept-as-is 19800428 NCR#99-77 Torus shell pitting Rework 19701280 NCR#99 80 Gibbs manway bolting conditions Accept as-is 19800428 NCR#99-81 Deformed threads on north torus hatch Accept-as-is 19800428 NCR#99 83 Jet pump #16 visual discrepancies Accept-as-is 19800749 NCR#99-84 Snubber clamp embedded in 6" line and cold piston setting out of tolerance Repair 19702753 NCR#99 88 Jet pump set screw gaps Accept-as-is 19800749 NCR#99 89 Various drywell head bolting conditions Rework 19800428 NCR#99-91 Invessel Core Spray piping P5 weld indications Accept as-is 19800749 NCR#99 98 Min. wall condition of RilR weld 10R-IB-8 Accept-as-is E9800005 page 13 of 20

i

  • =

TABLE 4 PRESERVICE VISUAL EXAMS PERFORMED DURING 1999 VT-1-99004 SRV203-3A PILOT S/N I16 MS VT-3 05/17/99 1960l059 VT-10-99010 H-10-I-84SA RHR VT-3 05/19/99 E9800088 VT-10-99011 H 10-1-36SR RiiR VT-3 05/19/99 197027l1 l VT 10-99012 CK1001-68B VALVE ilYDRO RIIR VT-2 06/08/99 E9800005 VT-10-99013 10CK-1001-28 VALVE PWT RHR VT 2 06/26/99 E9700056 VT-10-99014 10CK-1001-2D VALVE PWT RHR VT-2 06/26/99 E9700055 VT 13-99004 MOl301-17 PWT RCIC VT-2 07/01/99 19803030 j VT-23-99006 H-23-1-86 IIPCI VT-3 05/27/99 19702753 VT-29-99004 BASELINE OF NEW 'B' LOOP SPOOLS SSW VT-2 06/01/99 19800596 VT-29-99005 BASELINE OF NEW 'A' AUX BAY SPOOLS SSW VT-2 06/02/99 19800821 VT 29-99006 BASELINE OF NEW 'A' LOOP SPOOLS SSW VT-2 05/31/99 19800821 j VT-29-99007 BASELINE OF SPOOLS 2-3,2-4,5-5 SSW VT-2 05/22/99 19803033 VT-29-99008 D ASELINE OF SPOOL JF-29-11-5 SSW VT-2 06/02/99 19900977 VT-29-99009 PWT OF SPOOL JF-29-3-5 SSW VT-2 06/02/99 19902773 VT 29-99010 PWT OF SPOOL JF-29-5-3 SSW VT-2 05/22/99 19900422 VT-29 990ll H-29-l.1045 BASELINE SSW VT-3 05/24/99 19803033 VT 29-99012 H-291-1045 BASELINE SSW VT-3 05/20/99 19803033 VT-29-99013 SPOOL PIECE JF29-6-4 AND CONNECTS. SSW VT-2 06/26/99 19901458 VT-30-99001 SLT RBCCW-1 RBCCW VT 2 01/25/99 19800428 VT-30-99002 H-30-1.E209B RBCCW VT-3 02/10/99 19800428 VT-30-99020 P202A SUCTION STRAINER PWT RBCCW VT-2 05/21/99 19802126 VT-30-99021 30-110-36 VALVE PWT RBCCW VT-2 05/19/99 19900602 l VT-30-99022 P-2028 MECil. SEAL RBCCW VT-2 04/15/99 E9900017 I VT-30-99023 P202B SUCTION STRAINER PWT RBCCW VT-2 04/15/99 19801963 VT-30-99024 H-30-1 E209A BASELINE RBCCW VT-3 03/23/99 E9800098 VT-30-99025 P-202F SUCTION STRAINER PWT RBCCW VT-2 03/09/99 19801960 VT-30-99026 P-202D SUCTION STRAINER PWT RBCCW VT-2 03/02/99 1980196i VT-30-99027 P-202E SUCrlON STRAINER PWT RBCCW VT-2 02/23/99 1980192 l VT-30-99028 H-30-1-E122B RBCCW VT-3 02/17/99 E9800096 l l l I page 14 of 20

l TABLES l MISCELLANEOUS VISUAL EXAMS PERFORMED DURING 1999 f' '23%Q@&T=M=ir.M.M@J#fA10217_.i mudjQaiinit gg@fdr1GegPf%Gpj: l VT-1-99003 SRV 203-3 A PILOT S/N 1208 AS-FOUND MS VT-3 05/16/99 19601059 l VT-1-99005 RV203-41 BOLTINO MS VT-3 06/21/99 19801172 VT-il-99001 H ll-1-32 SDLC VT-3 03/09/99 19702748 { VT-14-99006 1400-25B VALVE INTERNALS CS VT-3 05/26/99 VT-3-99001 H 3-1-21 CRD VT 3 03/01/99 19702741 VT-3-99002 H-3 1-49 CRD VT-3 03/01/99 19702741 VT-30-99019 TBCCW PIPINO FOR STRESS CORROSION TBCCW VT-2 04/23/99 S9705505 ) CRACKINO ( VT-45-99001 H-45-1-4 CACS VT-3 03/16/99 19702770 l VT-50-99004 IWE ANNDRN-080,-170,-260,-350 CONT VT 2 05/12/99 19800428 VT-50-99005 IWE-LINERDRAINS CONT VT-2 05/16/99 19800428 VT-50-99006 IWE-ANNDRN-080,-170,-260,-350 CONT VT-2 05/28/99 19800428 VT-54 99001 CLASS I HYDRO - DRYWELL 9&23' RPV VT-2 06/19/99 19802028 ) VT-54-99002 CLASS I HYDRO DRYWELL 41&51' RPV VT-2 06/19/99 19802028 VT 54-99003 CLASS I HYDRO-DRYWELL 74,83,91' RPV VT-2 06/19/99 19802028 i VT-54-99004 CLASS 1 HYDRO - TORUS ROOM RPV VT 2 06/19/99 19802028 VT-54-99005 CLASS I HYDRO 'A' VALVE ROOM RPV VT-2 06/19/99 19802028 VT-54-99006 CLASS i llYDRO 'B' VALVE ROOM RPV VT-2 06/19/99 19802028 VT-54-99007 CLASS I HYDRO 'B' VALVE ROOM RPV VT 2 06/19/99 19802028 VT-54-99008 CLASS I HYDRO TIP ROOM RPV VT-2 06/19/99 19802028 VT-54 99009 CLASS I HYDRO-RWCU HX ROOM RPV VT-2 06/19/99 19802028 VT-54 99010 CLASS I HYDRO - EAST / WEST CRDs RPV VT-2 06/19/99 19802028 VT-54-990ll CLASS 1 IIYDRO - EAST / WEST SANDBOXES RPV VT-2 06/19/99 19802028 VT-54 99012 CLASS 1 HYDRO RB 51' RPV VT-2 06/19/99 19802028 VT-54 99013 CLASS 1 HYDRO RB 74' RPV VT-2 06/19/99 19802028 VT-54 99014 CLASS 1 HYDRO-CRD REPAIR AREA RPV VT-2 06/19/99 19802028 l TABLE 6 page 15 of 20

o. TABLE 6 PRESERVICE VISUAL EXAMS PERFORMED DURING 1998 .ms#2 nCOMP4NEhlT/ j#6 MsRMhMPE94AB@l0MtUi VT-10-98001 'B' RHR DECON TIE-IN MOD. RHR VT-2 07/29/98 E9800101 VT-10-98002 'A' RilR DECON TIE-IN MOD. RiiR VT-2 08/lI/98 E9800102 VT-29-98001 AV-38007 VALVE AT P 208E PUMP SSW VT-2 02/13/98 E9700182 VT-29 98002 TEMP. SUPPORT SKC-98-01-JAK-01 SSW VT-3 03/02/98 19602271 VT-29 98003 XJ 317 AT P-208B SSW VT-2 01/23/98 19600521 VT-29 98004 P-208B COLUMNS SSW VT 2 01/23/98 19702726 VT-29-98005 TBCCW IIx. E-122A NEW HEADS SSW VT 2 03/09/98 19602271 VT-3-98001 11-3 2 1 CRD VT 3 01/06/98 19601945 TABLE 7 MISCELLANEOUS VISUAL EXAMS PERFORMED DURING 1998 @ATASHEETe @ /COMPONENTW@vidi SYSTEMnnEXAMSYPEe!E*?DATE WdNMRW VT-10-98003 SLT Ri!R 1 RHR VT 2 09/25/98 N/A I VT-14-98001 SLT CS 1 CS VT-2 09/25/98 N/A l VT-23-98001 SLT HPCI-l HPCI VT-2 03/12/98 N/A VT-29-98006 SLT SSW-2 SSW VT-2 09/13/98 N/A VT-29-98007 SLT SSW-3 SSW VT-2 09/13/98 N/A VT-30-98001 SLT RBCCW-8 RBCCW VT-2 03/02/98 N/A VT-45-98001 SLT PASS-1 PASS VT-2 10/08/98 N/A VT-45-98002 SLT PASS-2 PASS VT-2 11/18/98 N/A VT-6-98001 SLT FW-1 FW VT-2 04/18/98 N/A ii l TABLE 8 ) l PRESERVICE VISUAL EXAMS PERFORMED DURING 1997 l POST-RFO#11 l %$1lkMHackFW/E liCOMPONENTdW,WOMSYSTEMiiV&EXAMfTYPEWdDATESW4%MRF VT-l-97009 SRV203 3D LEAK CilECK MS VT 2 12/03/97 19601062 VT-10-97023 Il 10-1-SG16 RilR VT-3 04/09/97 19301461 l J page 16 of 20 4

l 1 TABLE 9 MISCELLANEOUS VISUAI EXAMS PERFORMED DURING 1997 P;ST-RFO#11 M ANIRW4MlMMMIRRE M MMERM VT-10-97026 SLT RilR-5 RHR VT-2 07/28/97 S9704750 l VT-10-97027 SLT RHR-I RHR VT-2 09/03/97 N/A VT-10-97028 SLT RHR-7 RHR VT-2 09/03/97 N/A VT-10-97029 SLT RHR-2 RHR VT-2 10/24/97 N/A VT-10-97030 SLT RHR-1 RHR VT-2 10/24/97 N/A VT.10-9703i SLT RHR-3 RHR VT-2 11/23/97 N/A VT II-97002 SLT SLC-3 SBLC VT-2 08/04/97 N/A VT-1197003 SLT SLC-3 SBLC VT-2 11/12/97 N/A VT-12-97002 SLT RWCU-l RWCU VT-2 10/21/97 N/A VT.I3-97001 SLT RCIC-3 RCIC VT-2 08/20/97 19401497 VT-13 97002 SLT RCIC-2 RCIC VT-2 08/20/97 19401497 f VT-13 97003 SLT RCIC-1 RCIC VT-2 08/20/97 19401497 l VT-13-97004 SLT RCIC-5 RCIC VT-2 08/20/97 19401497 VT-13-97005 SLT RCIC-4 RCIC VT-2 08/20/97 19401497 ) VT-13-97006 SLT RCIC-2 RCIC VT-2 11/12/97 N/A ) VT-13-97007 SLT RCIC-1 RCIC VT-2 11/04/97 N/A j VT 14-97002 SLT CS 1 CS VT-2 10/15/97 N/A VT-14-97003 SLT CS-2 CS VT-2 10/15/97 N/A f VT-14-97004 SLT CS-3 CS VT-2 10/15/97 N/A VT 14 97005 SLT CS-4 CS VT-2 10/15/97 N/A i VT 14 97006 SLT CS-5 CS VT-2 10/15/97 N/A l VT-!4-97007 SLT CS-6 CS VT-2 12/15/97 S9709538 i VT 14-97008 SLT CS-7 CS VT-2 12/15/97 S9709538 i VT-14-97009 SLT CS-8 CS VT-2 12/15/97 S9709538 VT-14-97010 SLT CS-6 CS VT-2 11/18/97 N/A I VT-14-97011 SLT CS-1 CS VT-2 11/18/97 N/A VT-20-97001 SLT RBCCW-5 RBCCW VT-2 08/13/97 N/A VT-23 97005 SLT HPCI-3 HPCI VT-2 06/03/97 N/A VT-23-97006 SLT HPCI 4 HPCI VT-2 11/18/97 N/A VT-23-97007 SLT HPCI-l HPCI VT-2 11/04/97 N/A ) VT-23-97008 SLT HPCI-I HPCI VT 2 1I/18/97 N/A VT 23 97009 SLT HPCI-5 IIPCI VT-2 12/17/97 N/A VT-23-97010 SLT HPCI 2 HPCI VT-2 12/17/97 N/A VT 29-97015 SLT SSW-1 SSW VT-2 05/30/97 N/A VT-29-97016 SLT SSW-1 SSW VT-2 05/29/97 N/A l I VT-29 97017 SLT SSW-2 &3 SSW VT-2 05/29/97 N/A VT 29-97018 SLT SSW-1 SSW VT-2 08/01/97 N/A VT-30-97005 SLT RBCCW-7 RBCCW VT-2 08/01/97 N/A VT-30-97006 SLT RBCCW-6 RBCCW VT-2 08/04/97 N/A VT-30-97007 SLT RBCCW-9 RBCCW VT-2 08/04/97 N/A VT-30-97008 SLT RBCCW-5 RBCCW VT-2 08/13/97 N/A VT-30-97009 SLT RBCCW-5 RBCCW VT-2 08/13/97 N/A page 17 of 20

j =, TABLE 10 RFO#12 FLOW-ASSISTED CORROSION EXAMINATIONS t j .h 15 DE6-7-12 E FW 16 Elbow E-105 A FW to RPV COND. BAY 99 PSI 51 E MS 20 Elbow From Vessel to SV-4 DRYWELL 105 DL6-1-31 T FW 18x12 Tee D/S of Pen X-9A DRYWELL 106 DL6-1-41 R FW 18x12 Reducer D/S of Pen X 9A DRYWELL 107 DL6-5-4-1 T FW 18x12 Tee D/S of Pen X 98 DRYWELL 108 DL6-5-4-1 R FW 18x12 Reducer D/S of Pen X-9B DRYWELL 110 GE18-8-il 1 E COND 14 Elbow Disch Pump P101 A TB 6' 155 HE17-8-3-1 E HVD 6 Elbow E105B to E104B COND. B AY 194 HF16-FSK-1-3 E EXTSTM l.5 Elbow 9th Stg Drn to Cond COND. BAY 205 DE6-8-2-1 R FW 18 Reducer FW E104A to E105 A COND. B AY 208 GE25-1 1-1 E COND V&D 6 Elbow D/S of FE-9231 COND. B AY 212 DL6-6-31 T FW 6 Tee RWCU RCIC Inlet STEAM TUNNEL 213 DE6-14-1-1 T FW 16 Tee FW P103B to Hdr CONDl BAY 217 DL6-1 1 1 T FW 18xl4 Tee FW/HPCI Connection STEAM TUNNEL 219 HF16-8-1-1 E EXTSTM 12 Elbow 8th Stg Extr to E104A COND. BAY 220 HF16-8-I-2 E EXTSTM 12 Elbow 8th Stg Extr to E104A COND. B AY 221 GFI 6-3-1-1 T EXTSTM 42 Tee Cross-Around Piping COND. BAY 225 GFl6-2-21 E EXTSTM I4 Elbow ist Stg to E105A COND. BAY 226 GF16-3-4 2 E EXTSTM 14 Elbow ist Stg to E105B COND. BAY 227 GF16-3 8-l E EXTSTM 14 Elbow ist Stg to E105B COND. B AY 229 GE18151-1 N COND 16 Nonle E103B to P103C COND. BAY 230 GE18-15 2-1 E COND 16 Elbow E103B to P103C COND. BAY 232 GE1815-3-1 E COND 16 Elbow E103B to P103C COND. BAY 234 DE6 5-2-1 N FW 18 Noule E104B to E105B COND. B AY 235 DE6-7-3-1 E FW 16 Elbow E105A to FV-642B COND. BAY 236 DE6-7-4-1 T FW 24x24 Tee E105 A to FV-642B COND. BAY 238 DE6-14-21 T FW 16x16x10 Tee E104B Htr Bypass COND. BAY 239 HEl?-42-1-1 E HVD 12 Elbow E103B to E102B COND. BAY 241 ilE17-2 3-1 E HVD 10 Elbow E104A to E103A COND. B AY 242 DE6 3-1-1 E FW 16 Elbow Htr E105B Disch COND. B AY 243 HE17-10-6-1 E HVD 10 Elbow E104B to Cond COND. BAY 244 IIE17-3-4-1 N l{VD 10 Nonle E104A to E103 A COND. BAY 245 HE17-10-21 E HVD 10 Elbow E104B to E103B COND. BAY 246 HE17-1-4-2 E HVD 6 Elbow El05 A to E104A COND. BAY 247 HEl7-14-3 E HVD 6 Elbow E105A to E104A COND. BAY 248 HEl7-1-3 2 E HVD 6 Elbow E105 A to E104A COND. BAY 249 HE17112 E HVD 6 Elbow E105A to E104A COND. BAY 250 HEl7-I-4-1 N HVD 6 Nonle E105A to E104A COND. BAY 25.1 EE-t-9-2-1 T MS 6x6 Tee U/S of1 HO-106 COND. BAY 252 GE18-12-6-IV P COND 10 Pipe E-108 to Cond COND. B AY page 18 0f 20

TABLE 10 (continued) RFO#12 FLOW ASSISTED CORROSION EXAMINATIONS h bb 253 EE 1-1-4-1 E MS 2 Elbow D/S of PV-9239 COND. BAY 254 EE l.1-4-2 E MS 2 Elbow D/S of PV-9239 COND. BAY 255 EE-t-i-4-1 R MS 4x 1.5 Reducer U/S of PV 9238 COND. BAY 256 EBC(B)-I-1-1 E MS 4 Elbow D/S of MO-9204 COND. BAY 257 GE18-17-7-1 E COND 16 Elbow E102A to E103 A COND. BAY 258 HE-1-1-1-1 E MS 4 Elbow D/S of PV-9238 COND. BAY 259 D/S of RO3460 FW l Pipe P-103B w/u line TB,51' 260 SP EE-1-1-12 E MS I Elbow D/S of PCV-9251 COND. BAY 261 SP eel-1-1 E MS 1.5 Elbow D/S of PCV-9251 COND. BAY 262 SP-eel-1 1 N MS 1.5 Nozzle At E-305A COND. BAY 264 DE16-81 1 N EXTSTM 12 Nonle P-1038 Disch Nonle TB$1' 265 GE18-2-41 E COND 6 Elbow D/S of MO-9272 COND. BAY 266 D/S of RO3470 FW l Pipe P-103C w/u line TB 51' 267 HEl-1 !!-2 E MS 2.5 Elbow D/S of 1 HO-163 COND. BAY 269 SK-2105-1 E MS 4 Elbow D/S o' l-HO-107 COND. BAY 270 HF16-10-1-IN P EXTSTM 30 Pipe 13th Stg Extr to E101 A COND. BAY 271 HFA 16-2 N MS 24 Nonle 9th Stg Extr to E103A COND. BAY 272 HE17-10-2-1 T HVD 10x10 Tee U/S of E-103B (HV&D) COND. BAY 273 HE17-2-4-4 T HVD 10 Tee U/S of E-103 A (HV&D) COND. B AY 274 Nozzle at Pen HVD 12 Nonle D/S of LV 3131 COND. BAY 45 275 Nonle at Pen HVD 10 Nozzle D/S of LV-314 i COND. BAY 46 276 Nozzle at Pen HVD 6 Nozzle D/S of LV 3151 COND. BAY 47 277 Nozzle at Pen HVD 8 Nonle D/S of LV-3008 COND. BAY 48 278 Htt E-103A HVD n/a Her Shell Htr shell at Extr Nozz COND. BAY Shell 279 HEl-1-5-2 E MS 4 Elbow D/S of I-HO-168 COND. BAY I 280 HF16-10-1 1 N EXTSTM 30 Nozzle 13th Extr to E101 A COND. BAY l MSDI MS Drain MS 2 Elbow 2" Elbow D/S of 220-3 COND. BAY MSD2 MS Drain MS 2x3 Tee 2x3" Tee D/S of 220-3 COND. BAY I l l l } ) l I l page 19 of 20

TABLE 11 RFO#12 AND ON-LINE ISI MAINTENANCE REQUESTS 19702749 RWCU 19702748 SBLC 19702744 RECIRC 19702750 RCIC 19702743 MS 19702753 HPCI 19702742 FW i 19702752 CS -- both loops 19702745 RHR - A LOOP & SDC ) 19702746 RHR - B LOOP & SSW X-TIE 19702755 RBCCW - Aloop 19702756 RBCCW - B loop i 19702741 CRD 19702770 CACS 19702771 SSW - A & B loops 19800749 RPV IVVI exams 19702757 RPV nozzles and drywell 19802028 CLASS 1 system leakage test IWE CCNTAINMENT EXAMS 19800428 Augmented IWE exam scope, supports, bolting S9900211 General Visual Walkdown of containment (SMR); PNPS 2.1.8.7 S9900135 Pump out 8, clean 4 vents for IWE visual exam of vents EROSION / CORROSION SPEC. M-577 EXAMS 19801057 Extraction Steam 19801058 Condenser Vents and Drains 19801059 Condensate 19801060 Main Steam 19801061 Heater Vents and Drains 19801062 Feedwater SSW SPEC. M-591 EXAMS 19702754 SSW A loop piping UT and interior visual exams 19702772 SSW B loop piping UT and interior visual exams 19702773 SSW A loop discharge crawler visual exam page 20 of 20

p 1 1 e, FORM NIS-I OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Enterry (N; = ind Address of Owner)
2. Plant Pilgrim Nuclear PoJ3r.hfi3. ' ) Rocky Hill Road. Plymouth. Mass. 02360 (i1xnc and Address of Plant)
3. Plant Unit
  1. 1
4. Owner of Authorization (if required)

N/A

5. Commerical Service Date 12-9-72
6. National Board Number for Unit 20763 i
7. Components Inspected Manufacturer Components or Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No. Board No. Reactor Vessel Pinine Combustion Enr. Bechtel 66107 66207 20763 1 N/A N/A N/A i l l Note: Supplemental sheets la form of lists, sketches, or drawings may be used provided (1) slu is 31/2 in. x 11 in. l (2)Information la items i through 6 on this data report is included on each sheet, and (3) each sheet is numbered l and number of sheets is recorded at the top of this form. 1 1 L

[ ] FORM NIS-1 (Back)

8. Exammation Dates 3-30-97 to 7-8-99
9. Insection Interval from 6-30-95 to 6-30-05
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval See ISI Summary Report i1. Abstract of Conditions Noted.

See ISI Summary Report

12. Abstract of Corrective Measures Recommended and Taken See ISI Summary Report and NIS-2 Forms We certifiy that the statements made in this report are correct and the exatninations and corrective measures taken conform to the rules of the ASME Code, Section XI 9!f 19 N Signed _. Entusv By _

, QA Manager Date C Owner Certificate of Authorization No. (if applicable) N/A Expiration Date CERTIFICATE OF INSERVICE INSPECTION { 1, the undersigned, holding a valid commision issued by the national board of Boiler and Pressure Vessel Inspectors and/or the State or Province of M.A and employed by Factory Mutual Insurance Co. of Walthant MA have inspected the components described in this Owners' Data Report during the period of to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owners' Data Report. Furthermore, neither the Inspector or his empoyer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Date 19 Cornmisions MA 1420 Inspector's Signature National Board, State, Province and No.

a FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Seccion XI

1. Owner Enterav Louisiana. Inc.

Date 1/19/98 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of 2'/ Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19701472 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A

) Name Authorization No. N/A 600 Rockv Hill Road Plymouth. MA 02360 Expiration Date N/A

4. Identification of System Core Sorav
5. (a) Applicable Construction Code 1131.1 1967 Edition Addenda _.

Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 i

6. Identification of Components Repaired or Replaced and Replacement Components ASME Coda
Repaired, Stamped Name of Name of Manufacturer National Other Year Replaced, or (Yes or Component Manufacturer Serial No.

Board No. Identification Built Replacement No) Valve Walworth 1401-25B Repaired

7. Description of Work Replaced Valve Disc /Boltimt
8. Test Conducted: Hydrostatic O Pneumatic 0 Nominai Operatino Pressure 3 Other O Pressure rest Temp.

F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) infennation in items 1 through G on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

l 1 FORM NIS 2 (Back)

9. Remarks All Work Completed in Accordance with MR 19701472 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Renair conforms to the rules of the ASME Code, Section XI.

Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authoriz t No. N/A Expiration Date I /3[4chdA @5 ,19 @k Signed AA~s / W A ' ' Owned or Owr Designae, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the Stdte or Province of Massachusetts and employed by *Arkwright Insurance Co. of Norwood. Massachusetts ' have inspected the components described in this Owner's Report during the period /- / 9-M to 7-8*-99 and state that to be best of my knowledge

and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the' inspection nor his employer makes any warranty, expressed or ir$ plied, concoming the examinations and corrective measures described in this Owner's ' Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a l loss of any kind arisin pom or onnected with this inspection. NA WM l vtl&4 Commissions inspector's Sign'aturf National Board, State, Province, and Endorsements k-3199 / Date

  • Factory Mutual Insurance Co.

) i l (12/82) .p r q

p 1 l l i l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l

1. Owner Enterav Louisiana. Inc.

Date 7/04/99 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of 1 Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19901572 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address 3.. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp __N/A Name Authorization No. N/A 600 Rocky Hill Road. Plymouth. MA 02360 . Expiration Date N/A

4. Identification of System E'
5. (a) Applicable Construction Code ASME Class 1 1974 Edition 1975 kl Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
Repaired, Stamped Name of Name of Manufacturer National Other Year Replaced, or (Yes or Component Manufacturer Serial No.

Board No. Identification Built Replacement No) Valve Anchor Darling E3-112 3 CK-1301-50 1974 Repaired No .s

7. Description of Work Partial Penetration Weld at Hinae Pin CoverNalve Body
8. Test Conducted: Hydrostatic O Pneumatic O.

Nominai Operating Pressure a Other' O Pressure Test Temp. r NOTE: Supplernental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i-

FORM NIS-2 (Back)

9. Remarks ASME Class 1 (Section lii) Valve is Used in a PNPS ASME/ ANSI B31.1 Aoolication oer PNPS FSAR.

Applicable Manufacturer's Data Reports to be attached Valve is not Reauired to be ASME Class 1 Code Stamoed. CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reoair conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorizatio o. N/A Expiration Date Signed Da e 9'd , 19 7 i Owner or Qwner's D'esignae, Title CERTIFICATE OF INSERVICE INSPECTION 1 the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Massachusetts and employed by *Arkwright Insurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period '7- // - 9 9 to 7-F-7 9, and state that to be best of m/ L'owledge and belief, the Owner has performed examinations and taken corrective measures described in this Owwa Report in accordance with the requirements of the ASME Code, Section XI. i By signing this certificat? aeither the inspection nor his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his emp yershall be liable in any manner for any personal injury or property damage or a loss of any kind arisin or c nnected with this inspection. Commissions Nk / dh') Inspector's Signaiure [/" ' ' National Board, State, Province, and Endorsements Date @-319 W ' Factory Mutual Insurance Co. (12/82) i 1

l... *

  • FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I

i

1. Owner Enterav Louisiana. Inc.

Date 5/05/99 Name - 639 Loyola Ave.. New Orleans, LA 70113 Sheet 1 of II-Address

2. Plant ~ Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name LSP010521 cm Rocky Hill Road, Plymouth, MA 02360 Repair Organizatio(P.O. No) Job No., etc. Address Target Rock and

3. Work Performed by Pilarim Nuclear Power StatiSD Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rocky Hill Road. Plvmouth. MA 02360 Expiration Date N/A

4. Identification of System Main Steam i
5. (a) Applicable Construction Code ASME lil CL 1993 Edition SIQ Addenda Code Case t

I (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89

6. Identification of Components Repaired or Replaced and Replacement Components ASME
Repaired, Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No.

Board No. Identification Built Replacement (Yes or No) RV-203-3 Target Rock S/N-1040 Pilot Body 1980 Repaired Yes Corp S/N 43 l

7. Description of Work Pilot seat removed with new seat welded in olace

- 8. Test Conducted: Hydrostatic 8 Pneumatic 0 Nominal Operating Pressure Q Other O Pressure Test Temp.

  • F
  • Following installation. Class I Hydro NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2)

L information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form ' I - (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l I I L ~

FORM NIS 2 (Back) l

9. Remarks The reoaired oilot seat was installed and reworked for oroner leak tiahtness and setooint by avalified Applicable Manuf actJrer's Data Reports to be attached Taroet Rock Field Service Personnel. Certification Testina performed (PWT) at Wyle Labs. Leak tiahtness and nameolate setooint set.

l CERTIFICATE OF COMPLIANCE We certi'/ that the statements made in the report are correct and this Repair conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization No, N/A Expiration Date 1/ f Perdim Tm dltdMef Date %I ,19 % J Sign Owner or Owner's Designae, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned,l'1olding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts and employed by*Arkwright Insurance Co. of Norwood. MaRulchusetts have inspected the components described in this Owner's Report during the period C-f-99 to 7 - P 9 '7 and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. t By signing this certificate neither the inspection nor his employer maker cny warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employershall be liable in any manner for any personal injury or property damage or a le$ig,fr m o connected with this inspection. h-YM loss of any kind ii M4 4 Commissions inspector's Signa re National Board, State, Province, and Endorsements Date h-$19 / C/ C /

  • Factory MutualInsurance Co.

(12/82) i h d

a j FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI ]

1. Owner snigray Louisiana. Inc.

Date 6/01/99 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of // j Address )

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR P9700125 i Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rocky Hill Road. Plvmouth. MA 02360 Expiration Date N!A

4. Identification of System Sundy Llauid control S. (a) Applicable ConstructLin Code B31.1 1967 Edition Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repaltt-or Replacements 19 89 6, Identification of Components Repaired or Replaced and Replacement Components ASME Code
Repaired, Stamped Name of Name of Manufacturer National Other Year Replaced, or (Yes or Component Manufacturer Serial No.

Board No. Identification Built Replacement No) Valve Crosby Shop #53670 PSV-Il05B Repaired Yes

7. Description of Work Machined Valve Seatine Surfaces
8. Test Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressura $

Other O pressure Tesi Temp. F NOTE: _ Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

i FORM NIS 2 (Back)

9. Remarks All work completed in accordance with MR P9700125 Applicable Manufacturer's Data Reports to be attached

~ CERTIFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this Reoair conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date Signed A M CC U 0 d CA A M ate %3 ,19 h Owg or OwnerM Designae, Title CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Massachusetts and employed by*Arkwright Insurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period 4-/- 99 to 7 M and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concerning the examinatios and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his emplo) wrshall be liable in any manner for any personal injury or property damage or a loss of any kind ar' ' rig from o connected with this inspection. M/4J Commissions M/M inspector's Signatp National Board, State, Province, and Endorsements Date

f. 2, j g 9 y
  • Factory Mutual Insurance Co.

(12/82)

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Enterav Louisiana. Inc.

Date 5/27/99 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of // Address

2. Plant ' Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19702753 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rocky Hill Road. Plymouth, MA 02360 Expiration Date N/A

4. Identification of System HPCI
5. (a) Applicable Construction Code B31.1 1967 Edition Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989..
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
Repaired, Stamped Name of Name of Manufacturer National Other Year Replaced, or (Yes or Component Manufacturer Serial No.

Board No. Identification Built Replacement No) Snubber B/P H-23 1-86 Repaired No FRN 99-0157 to remove 1/2" of Material from Corner of

7. Description of Work Snubber Clamo to remove interference.
8. Test Conducted: Hydrostatic O -

Pneumatic O Nominal Operating Pressure O (v13 be.eiine exami Other S Pressure Test Temp.

  • F NOTE: ' Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2)

L Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

l i FORM NIS 2 (Back) 9.' Remarks All Work comoleted in Accordance with MR #19702753. Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Renair conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of uthoriza ' No. N/A Expiration Date M D MIbonTmm et?wAerDate Signed ' Ownerfor Owners Designae, Title 9-1 , 29 W CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Massachusetts and employed by*Arkwright Insurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period <- R 7-99 to 7-F- 9 9 and state that to be best of my knowledge r and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. I By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind aris from r connected with this inspection. f/, V8 Commissions NA. /NM 7 Inspector's Signatu ~~ - National Board, State, Province, and Endorsements Date 9'- 4 19 */ *7 '/

  • Factory Mutual lasurance Co.

(12/82) )

c L FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Enterav Louisiana, Inc.

Date 1/28/99 Name - 639 Loyola Ave., New Orleansi LA 70113 Sheet 1 of f I Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19702038 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rockv Hill Road. P!vmouth. MA 02360 Expiration Date N/A

4. Identification of System Main Steam System
5. (a) Applicable Construction Code ASME 111 1989_ Edition 82 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 l

I

6. Identification of Components Repaired or Replaced and Replacement Components i

ASME

Repaired, Code Name of Name of.

Manufacturer National Other Year Replaced or Stamped Component Mar ufacturer Serial No. Board No. Identification Built Replacement (Yes or No) l l l Valve Atwood & Morrill AO-203 lC 1982 Repaired Yes l l l l l i . 7. Descr'ption of Work Rebuilt and Reolaced BoltvNuts as Reauired IAW MR No. 19702038 l

8. Test Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure @ In-service Leak Test Other O '

Pressure Test Temp.

  • F l

l-NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the asumber of sheets [? Is recorded at the top of this form. 1 (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

f l FORM NIS-2 (Back) 9, Remarks All work comoleted in accordance with MR #19702038 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reoair conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Oate Signed ."2NJAum 7 e M te N ,19 N ' Owner or Dwner's 6esignae, Title CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts and employed by*Arkwright Insurance Co. of Norwood. Massachusetts have inspected the compononts described in this Owner's Report during the period /- SRL 9 ') to 7-R-99 ' and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. I By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concerning th,e examinations and corrective measures described in this Owner's Repoit. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arj ' f omgonnected with this inspection, i,. t$) / Commissions N/l ' /VM i inspector's Signatpe ~ National Board, State, Province, and Endorsements I Date 94197 Cf < /

  • Factory Mutual Insurance Co.

(12/82) ~

I FORM N!S 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code SectioN XI i

1. Owner Enterav Louisiana Inc.

Date 4/02/19 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet-1 of

/ /

Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19702259 i Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code S,mbol Stamp N/A j

Name Authorization No. N/A-600 Rockv Hill RoasL,fjvmouth. MA 02MO Expiration Date N/A

4. Identification of System Recirculation Systeg
5. (a) Applicable Construction Code ASME lil 1980 Edition W81 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989

) 1

6. Identification of Components Repaired or Replaced and Replacement Components l

ASME L Code

Repaired, Stampe i

l Name of ' Name of Manufacturer National Other Year Replaced, or d (Yes I Component Manufacturer Serial No. Board No. Identification Built Replacement or No) Flange Replacement No

7. Description of Work Replaced Decon. Flanne Boltin_g.at ' A' Recire. Pumo
8. Test Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure B Jther O Pressure Test Temp.

'F NOTEf Supplernental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in itemis 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded 61 the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 s

I FORM NIS-2 (Back)

9. Remarks All work completed in accordance with MR No. 19702259 Applicable Manufacturer's Data Reports to be attached i

CERTIFICATE OF COMPLIANCE We certify that the statsraents made in the report are correct and this Reolacerr.ent conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorizati No. N/A Expiration Date M8c(#fo^ 724e / Mot /Ayf Date 7'l ,19 77 Signed ' Owner br Owner's Designee, Title r i ? CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts , and employed by *Adwright Insurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period 9-#-99 to 7-9-99 and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described E this Owrer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures describod in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personalinjury or property damage or a loss of any kind arisin (hm or c nnected with this inspection. I R t/ tc M. Commissions M /kd-t> inspector's Signature National Board, State, Province, and Endorsements Date 9-3199 9 / <

  • Factory Mutual Insurance Co.

(12/82) l l

'\\ . o.o FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

1. Owner Enterav Louisiana. Inc.

Date 5/03/99 Name ,Il 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19703070 Rocky Hill Road, Plymouth, MA 02360. Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rockv Hill Road Plymouth. MA 02360 Expiration Date N/A

4. Identification of System CRD
5. (a) Applicable Construction Code B31.1 1992 Edition Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of

. Name of Manufacturer Board. No. Other Year Replaced, or (Yes or Component - Manufacturer Serial No. Identification Built Replacement No) Flange General Electric Replacement No

7. Des'cription of Work Rrolaced Cao Screws that Connect to the Housing Flanne
8. Test Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure G Inservice Leak Test Other O Pressure Test Temp.

'F (VT-2) During Class l Hydro i NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) l Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (EOOO30) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 1' L

f a

  • FORM NIS-2 (Back)
9. Remarks' All work comoteted in accordance with MR #19703070 Applicable Manufacturer's Data Reports to be attached g,

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp' N/A Certificate of Authorization No. N/A Expiration Date MIM~c^ AM N4lyof Date 9-7 ,19 99 Signed ~ % Ogjer or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION - 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts and employed by*Arkwrimht Insurance Co. of Norwood. Massachusetts - have inspected the components described in this Owner's Report during the period S-3-99' to 7-&-9 9 and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures desciibed in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. t By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector not his employershall be liable in any manner for any personalinjury or property damage or a inss of any kind arisin gr onnected with this inspection. X. Commissions MI //M National Board, State, Province, and Endorsements inspector's Signature. j Date 7-31977

  • Factory Mutual Insurance Co.

' (12/82) -i

1 ..i,

  • e, 1

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Entarav Louisiana. Inc.

Date 2/09/99 Name 639 Loyr!a Ave., New Orleans, LA 70113 Sheet 1 _ ' of __/_j, Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19703075 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job Nc., etc. Address -

3. Work Performed by Pjlarim Nuclear Power Station Type Code Symbol Stamp _ _ N/A Name Authorization No.

N/A 600 Rocky Hill Road. Pfvmouth MA 02360 Expiration Date N/A

4. Identification of System Local Power Ranae Monitors i
5. (a) Appucable Construction Code N/A 19 Edition Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1931_

j

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
Repaired, Stamped Name of Name of -

Manufacturer National Other Year Replaced, or (Yes or Component - Manufacturer Serial No. Board No. Identification Built Replacement No) 20-45,28-13 LPRM 20 General Electric 36-37 Replacement No

7. Description of Work Replace LPRM detector strinas in Reactor Vessel
8. Test Conducted: Hydrostatic O Pneumatic Nominal Operating Pressure O

'Other-@ Pressure 90eratina Test Temp. 'F VT.2 During class #1 Hydro -. NOTE:. Supplemental sheets in form of lists, sketches,' or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 \\

.a FORM NIS 2 (Back)

9. Remarks All Work Comoleted in Accordance with MR #19703075 Applicable Manuf acturr's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI.

Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authori thn No. N/A Expiration Date Signed QMb'flon I& MW Date fN , 19 97 OwrWr or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Massachusetts and employed by *Arkwright Insurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period

,2-9-99 to 7 7 9 and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. t By signing this certificate neither the inspection not his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personalinjury or property damage or a loss of any kind

  • g fr or connected with this inspection.

Commissions NM / M Inspector's Signapre National Board, State, Province, and Endorsements Date f-k19 79 / ' Factory Mutual Insurance Co. (12/82) w. W

I l 6 * ..,a i FORM NIS-2 OWNER'S REPORT FOR REPAIRS /M.? PLACEMENTS l As Required by the Provisions of the ASME Coh Section XI L -1. Owner Enterav Louisiana. Inc. Date 2/01/99 Name l. 639 Loyola Ave., New Orleans, LA 70113 ' Sheet 1 of fl l Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 -- Pilgrim Nuclear Power Station i Name FRN 98-01-14 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A DOO Rocky Hill Road Plvmouth MA 02360 Expiration Date N/A

4. Identification of System __.R9_6Mual Heat Removal '

Thru Wmter

5. (a) Applicable Construction Code ANSI B31.1 1977 Edition 1979 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989..
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code t
Repaired, Stamped 4

l Name of . Name of Manufacturer National Other Year Replaced, or (Yes or Component Manufacturer Serial No. Board No. Identification Built Replacement No) Pipe Support H10-1-36SR Replacement N/A l 7.' LJacription of Work Replaced Anchor Bolts & Baseolate on Support H10-1-36SR - 8. Test Conducted: Hydrostatic 0 Pneumatic 0 Nominai Operatin, Pressure O l Other @ Pressure Test Temp. 'F l (VT-3) !~ NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. j. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I

  • i..

FORM NIS 2 (Back)

9. Remarks All work comoteted in accordance with FRN #98-01-14 Applicable Manufacturer's Data Reports to be attached l

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date Signed < Mbe" tem /w NN Date N , 19 il Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of_ Massachusetts and employed by *Arkwright Insurance Co. of Norwood Massachusetts have inspected the components described in this Owner's Report during the period ,4 -/ - 9 9 to 7-E-9 9 and state that to be best of my knowledge and belief, the Owner hra performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. s By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employershall be fiable in any manner for any personal injury or property damage or a loss of any kin isi fr or connected with this inspection. ~ <de-Commissions A// N/ >-C Inspector's Sipature National Board, State, Province, and Endorsements Date 9-11977 / ' Factory Mutual Insurance Co. I (12/82) l l

..o *

  • FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
1. Owner Enterav Louisiana. Inc.

Date 5/03/99 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of f/ Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR E9800082 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address -

3. Work Performed by Eilarim Nuclear Power Station Type Code Symbol Starnp N/A Name Authorization No.

N/A 600 Rocky Hill Road. Pivmouth. MA 02360 Expiration Date N/A

4. Identification of System Containment Sp_r_av IRHR)
5. (a) Applicable Construction Code _031.1 198R Edition R2 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 6, identification of Components Repaired or Replaced and Replacement Components ASME
Repaired, Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No.

Board No. Identification Built Replacement (Yes or No) Flange Cat. Item Replacement No

7. Description od Work Replaced Flanges and Bolting at Two Locations (see remarks)
8. Test Conducted: Hydrostatic O Pneumatic 0 Nominal Operating Pressure @ inservice Leak Test Other O Pressure Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

i s,, l FOIIM NIS-2 (Back)

9. Remarks Two Locations at 1001-23A & 26A and 1001-238 & 26B Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Roolacement conforms to the rules of the ASME Code, Section XI.

Repair or Replacement ) Type Code Symbol Stamp N/A Certificate of Authoriza ' n No. N/A Expiration Date Signed 7/l/fd'ohonTeAN M A N ,19 97 ate Ownef or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Massachusetts and employed by *Arkwright insurance Co. of Norwood, Massachusetts - have inspected the components described in this Owner's Report during the period C-J C 9 to 7-E-? 9 and state that to be best of my knowledge / _and belief, the Owner has performed examinations and taken corrective measures described in this Owner's j Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither ' the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any k rising i om or connected with this inspection. .. # &/44 - Commissions /fM */4/ O I ~ ' Inspectoi's'Siinature National Board, State, Province, and Endorsements l f-3 197 9 Date

  • Factory Mutual Insurance Co.

l'12/82) (

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Enterav Louisiana, Inc.

Date 8/23/96 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of // Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station i Name MR 19601945 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rocky Hill Road. Plymouth, MA 02360 Expiration Date N/A

4. Identification of System CRD
5. (a) Applicable Construction Code ANSI B31.1 19 77 Edition W-80 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer ~ Board Othor Year Replaced, or (Yes or Component Manufacturer Serial No.

No. Identification Built Replacement No) Support N/A H3-1-21 Replacement N/A

7. Description of Work Reolaced Support H3-1-21. Replaced Soring Can & Attachments
8. Test Conducted: Hydrostatic 0 Pneumatic Q Nominai Operating e, essure Q Other b Pressure Test Temp.

'F VT-3 Baseline Examination NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% In. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks All work comoleted in accordance with MR #19601945 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPl. LANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI.

Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date Signed IM$kC(Afo^ YMM [A M te 9d ,19 79 Owr (er or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts and employed by

  • Arkwright Insurance Co_ of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period R" # ~1 - 9 4 to 7-P- 9 9 and state that to be best of my knowledge

~ and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. i By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershalche liable in any manner for any personal injury or property damage or a j " loss of any kind /af nq&d' J - fjo or connected with this inspection, l Commissions N//Y}D I/( k inspector's' Sign ure National Board, State, Province, and Endorsements Date h-3-197 7 ' Factory Mutual Insurance Co. (12/82)

i i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Enterav Louisiana. Inc.

Date 4/05/99 l Name j l 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of fl 1 l Address l l 2; Plant Entergy Nuclear Generating Co. Unit 1 l Pilgrim Nuclear Power Station. j l Name Mh E9800005 i Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. l Address I l

3. Work Performed by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A I

l i Name. Authorization No. N/A l 600 Rocky Hill Road. Plvmouth. MA 02360 Expiration Date N/A l 4.ldentification of System RHR 1

5. (a) Applicable Construction Code ASME Sect. !!!

1986 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989

6. Identification of Components Repaired or Replaced and Replacement Components ASME l

Code

Repaired, Stamped Name of Name of Manufacturer National Other Year Replaced, or (Yes or i

Component Manufacturer Serial No. Board No. Identification Built Replacement No) ) ? I Valve Anchor Darling 100168B 1999 Replacement Yes l

7. Description of Work Reolaced Cherk Valve 1001-68B
8. Test Conducted: Hydrostatic 0 Pneumatic 0 Nominai Operating pressure O Spec. us9s Other O Pressure Test Temp.

'F l NOTE: Supplemental sheets in form of IIsts, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 j i-l p

r

  • s,.

FORM NIS 2 (Back)

9. Remarks Check Valve Replaced (1001688)

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization N/A Expiration Date Signed h MIM67M D N , 19 [ 9 Owner or Okner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Massachusetts and employed by *Arkwright insurance Co. of Norwood, Massachusetts have inspected the components described in this Owner's Report during d 8 9 9 to 7-W99 and state that to be best of my knowledge the period r and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personalinjury or property damage or a loss of any hii arisin from or connected with this inspection. V. d /- Commissions MA /kM Inspector's nature National Board, State, Province, and Endorsements Date f-3197 ')

  • Factory Mutual Insurance Co.

(12/82)

1 .., e FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Enterav Louisiana. Inc.

Date 5/19/99 Name 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 of If Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station-Name MR 19702552 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address

3. Work Performed by Pilorim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rocky Hill Road. Plymouth, MA 02360 Expiration Date N/A

4. Identification of System. Main Steam
5. (a) Applicable Construction Code B31.1 1967 Edition Addenda Code Case (b) Applicable Edition of Section XI Utilized for Reptirs or Replacements 19 82__
6. Identification of Components Repaired or Replaced and Replacement Components ASME
Repaired, Code Name of Name of Manufacturer National Other Year Rephced, or Stamped Component Manufacturer Serial No.

Board No. Identification Built Replacement (Yes or No) ) Snubber Pacific SN461 SS-1-10-34 Replacement No Scientific -

7. Description of Work SS-1-10-34 Replaced with S/N-40284
8. Test Conducted: Hydrostatic O Pneumatic 0 Nominai Operating Pressure Q Other h Pressure Test Temp.

'F Pre-Service NOTE: Supplemental sheets in form of Psts, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Information in items 1 through 6 on this report is included on each sheet is numbered and the number of sheets is recordad at the top of this form. (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

  • i,..

FORM NIS 2 (Back)

9. Remarks Snubber Scientific SN 461 failed functional. Snubber ie-bome reolaced with new snubber Applicatie Manufacturer's Data Reports to be attached serial number 40284.

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date MC#d^ ~Im /b^') 0 'C d Applicable Manuf acturer's Data Reports to be attached 1 l I i ~ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code, Section XI. Repair or Replacement Type Code Symbol Stamp N/A l Certificate of Author tion No. N/A Expiration Date Sign b 0^ TMA 87AWAYlDate 9I ,19 W OWrier or Own'er's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts and employed by

  • Arkwriaht.Jnsurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period c'? - A h 9 ()

to 7-P-99 and state that to be best of my knowledge and belief, the Owner has ' erformed examinations and taken corrective measures described in this Owner's p Report in accordance with the requirements of the ASME Code, Section XI. l By signing this certificate neither the inspection nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither j the Inspector nor his employershall be liable in any manner for any personalinjury or property damage or a loss of any kind aripjh ) from gr connected with this inspection. U/ MhW-Commissions 'AfA /MP I Inspector's Signat' rp ' National Board, State, Province, and Endorsements ~ i / ( Date 9-419'77 j

  • Factory Mutual Insurance Co.

l i (12/82) l l i )

de c3s i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Enterav Louisiana. Inc.

Date 4/98 Name of M 639 Loyola Ave., New Orleans, LA 70113 Sheet 1 Address

2. Plant Entergy Nuclear Generating Co.

Unit 1 Pilgrim Nuclear Power Station Name MR 19800651 Rocky Hill Road, Plymouth, MA 02360 Repair Organization P.O. No. Job No., etc. Address i

3. Work Performod by Pilarim Nuclear Power Station Type Code Symbol Stamp N/A Name Authorization No.

N/A 600 Rocky Hill Road, Plymouth. MA 02360 Expiration Date N/A j l

4. Identification of System Residual Heat Removal i
5. (a) Applicable Construction Code ANSI B31.1 19 77 Edition W-80 Addenda Code Case (b) Applicable Edition of Section XI Utilized for Repalts or Replacements 19 89
6. Identificailon of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No. Identification Built Replacement (Yes or No) i t Pipe Support H 10-1-84-SA Repaired No l l l 1 i

7. Description of Work Welded Brace frM 98-06) from VAC-204A/B Framine to Baseolate of Pioe Sucoort lil01-84-S.A Pneumatic O Nominal Operating Pressure O l
8. Test Conducted: Ilydrostatic O Other a Pressure Tesi Temp.

P I VT-3 - NOTE: ' Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. s 11 in.,(2) Information la items I through 6 on this report is included on each sheet is numbered and the number of stects is recorded at the top of ) this form. I (12/82) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 L.

~ % o,. e FORM NIS 2 (Back)

9. Remarks All work completeo in accordance with MR #19800651

) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Renair conforms to the rules of the ASME Code, Section XI. Repair or Replacement 9 Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date Signed' b MNCCM WAM D e N ,19 9$ Ownir or Owrfer's Designae, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Massachusetts and employed by*Arkwright Insurance Co. of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period 4//99 to > 5'- 9 9 and state that to be best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. f By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concoming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector not his employershall be liable in any manner for any personalinjury or property damage or a loss of any/prjd,44g/. Commissions NA / r/,1-n arisi from or connected with this inspection. I K1 inspector # Signaturb National Boar'd, State, Province, and Endorsements Date Y-3 19 @7

  • Factory Mutual Insurance Co.

(12/82) m}}