05000293/LER-1983-002-01, /01T-0:on 830116,flow Ref off-normal Alarm Received.Average Power Range Monitor Flux Scram Trip Settings Affected.Cause Under Investigation.Flow Inputs Monitored & Amplifier B Recalibr

From kanterella
(Redirected from ML20028G159)
Jump to navigation Jump to search
/01T-0:on 830116,flow Ref off-normal Alarm Received.Average Power Range Monitor Flux Scram Trip Settings Affected.Cause Under Investigation.Flow Inputs Monitored & Amplifier B Recalibr
ML20028G159
Person / Time
Site: Pilgrim
Issue date: 01/28/1983
From: Whitney G
BOSTON EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20028G157 List:
References
LER-83-002-01T, LER-83-2-1T, NUDOCS 8302070467
Download: ML20028G159 (1)


LER-1983-002, /01T-0:on 830116,flow Ref off-normal Alarm Received.Average Power Range Monitor Flux Scram Trip Settings Affected.Cause Under Investigation.Flow Inputs Monitored & Amplifier B Recalibr
Event date:
Report date:
2931983002R01 - NRC Website

text

U. S. NUCLEAR REGULATORY COMMISSION lyRC EOR,M 386 (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l

lh

. (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

lo lil lMI Al Pl Pl Sl 1l@l0l0l-l0l0l0l OI nl _l nl nl@l 4 l 1 l 1 l 1 l l@l l

l@

V 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO

$7 CAT 68 CON'T lol11 l L @l 0] Sl Ol -l Ol 2l 9l 3hl 0 l1 l1 l6l8l1l@lnliI9]nlRI9l@

"E 0R o 9C F

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 1 o l a l l On 1/16/83, while increasing power, a flow reference off-normal alarm was received. l 4

lo lal l It was determined that both A&B proportional amplifiers had drifted in a non-l l o 141 l conservative direction. The APRM flux scram trip settings were therefore l

l o I s l I af fected and T.S. section 2.1. A.1.a requirements were not met.

"A" channel was l

1o is l l found at 104 percent flow and "B" channel was at 91 percent flow, with an actual i

10171 l core flow of 81%. No cha11ence to the APRM scram settinns occurred durine this i

1ot8l l event: therefore. nublic health was not threatened.

l 80 7

8 9 E

CODE SUSCO E COMPONENT CODE SUSCODE SU E

l0l9l l Il Al@ W@ l Gl@ lIl Nl S l T j Rl Ul@ l Xl@ @ @

7 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION EV ENT YE AR REPORT NO.

CODE TYPE N O.

h y"LER/ROl 8l 3l l-l l0l0l2l y

l0l1l lTl

[ -J l0 l uMg

,21 22 23 24 26 27 28 29 30 31 32 EN AC O O P NT ME HOURS S8 1 FOR B.

SUPPLIER MA UF C RER l El@l Xl@

lZl@

[Zl@

l 0 l 0l 0l 0l W@

l Nl@ {@

l G l 0 l 8 l 0 l@

33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l i l o l l While a search for probable ' ause continues, monitoring of the AP101 flow inputs I

c ml will be continued daily during steady state condition as well as prior to and I

iii2l l during planned power maneuvers.

"B" amplifier was calibrated successfully.

"A" l

lil3l l amplifier output was found to be non-linear, but was reset 3 percent conservative i

l i 141 I wi thin T.S.

limits. The amplifiers are CEMAC tYne 563-02.

I 7

8 9 80 S

S

% POWER OTHER STATUS DlS O RY DISCOVERY DESCRIPTION l1 15 l W@ l 0l 8l 1'@l NA l

l A l@l Alarm Notification l

ACTIVITY CONTENT AMOUNT OF ACTIVITY LOCATION OF RELEASE RELE ASED@OF RELE ASE l NA l

l NA l

lt l6l 7

8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

l t l 71 l 010 l 0 lhl Zlhl l

PERSONNE L INJU IES NUMBER

DESCRIPTION

y l0]0l0l@l l

7 8 9 11 12 80 LOSS OF OR OAMAGE TO FACILITY TYPE

DESCRIPTION

I'I'I b!

8302050467 830128 PDR ADOCK 05000293 PUBL1 TY NRc usE ONLY 45 PDQ f.

ISSUED

DESCRIPTION

W hl NA l

lllllll))llll$

2 o 7

8 9 to 68 69 80 5 NAME OF PREPARER PHONE: