ML18019A613

From kanterella
Jump to navigation Jump to search
Westinghouse Hematite Decommissioning Project - Final Status Survey Final Report Volume 3, Chapter 16, Survey Area Release Record for Land Survey Area 05, Survey Units 01, 02, 03 and 04, Revision 1, LSA 05-03 Fssde Worksheets Uniform
ML18019A613
Person / Time
Site: 07000036
(SNM-0033)
Issue date: 01/09/2018
From:
Westinghouse
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18019A532 List: ... further results
References
HEM-18-2
Download: ML18019A613 (9)


Text

Survey Area:

==

Description:==

Survey Unit:

==

Description:==

Survey Type:

Classification:

Surface or CSM Type Start Elevation*

End Elevation*

Uniform S

434.9 431.7 Uniform S

431.7 431.2 Uniform S

435.9 432.5 Uniform S

432.5 432.0 Uniform S

434.6 433.9 Uniform S

433.9 433.4 Uniform S

435.7 433.7 Uniform S

433.7 433.2 Uniform S

434.7 434.2 Uniform S

434.2 433.7 Uniform S

435.6 434.6 Uniform S

434.6 434.1 Uniform S

438.1 437.3 Uniform S

437.3 436.8 Uniform S

435.1 433.9 Uniform S

433.9 433.4 Uniform S

435.5 433.9 Uniform S

433.9 433.4 Uniform S

439.1 437.0 Uniform S

437.0 436.5 Uniform S

436.6 435.1 Uniform S

435.1 434.6 Uniform Q

432.5 432.0 Uniform B

434.6 434.1 Uniform B

434.8 434.3 Uniform B

434.7 434.2 Uniform B

432.8 432.3 Uniform B

431.2 430.7 Uniform B

435.8 435.3 Uniform B

432.8 432.3 Uniform B

431.2 430.7 Uniform B

435.8 435.3 Uniform B

430.1 429.6 Uniform B

431.9 431.4 Uniform B

432.9 432.4

  • Elevations are in feet above mean sea level.
    • Missouri - East State Plane Coordinates [North American Datum (NAD) 1983]

Surface: Floor = F; Wall = W; Ceiling = C; Roof = R CSM: Three-Layer (Surface-Root-Excavation) or Uniform DCGLs used Type: Systematic = S, Biased = B; QC =Q; Investigation = I Quality Record Green shaded samples are the samples at each sample location, for use in WRS test.

L050350PUB00 864783.4 826701.3 Biased 6-in Grab L050351PUB00 864809.5 826704.5 Biased 6-in Grab L050348PUB00 864825.9 826699.6 Biased 6-in Grab L050349PUB00 864765.2 826730.7 Biased 6-in Grab L050346PUB00 864811.5 826707.6 Biased 6-in Grab L050347PUB00 864780.1 826739.2 Biased 6-in Grab L050344PUB00 864780.1 826739.2 Biased 6-in Grab L050345PUB00 864825.9 826699.6 Biased 6-in Grab L050325PUB00 864907.2 826827.6 Biased 6-in Grab L050343PUB00 864811.5 826707.6 Biased 6-in Grab L050323PUB00 864823.3 826718.4 Biased 6-in Grab L050324PUB00 864891.7 826783.8 Biased 6-in Grab L050322PES00 826826.7 864904.8 Excavation 6-in Grab L050304PEQ00 826706.5 864784.6 QA Duplicate Sample L050320PES00 826755.6 864885.7 Excavation 6-in Grab L050321PRS00 826826.7 864904.8 Root Zone Composite L050318PES00 826796.7 864874.7 Excavation 6-in Grab L050319PRS00 826755.6 864885.7 Root Zone Composite L050316PES00 826837.7 864863.7 Excavation 6-in Grab L050317PRS00 826796.7 864874.7 Root Zone Composite L050314PES00 826725.6 864855.7 Excavation 6-in Grab L050315PRS00 826837.7 864863.7 Root Zone Composite L050312PES00 826776.6 864844.7 Excavation 6-in Grab L050313PRS00 826725.6 864855.7 Root Zone Composite L050310PES00 826807.7 864833.7 Excavation 6-in Grab L050311PRS00 826776.6 864844.7 Root Zone Composite L050308PES00 826736.6 864814.6 Excavation 6-in Grab L050309PRS00 826807.7 864833.7 Root Zone Composite L050306PES00 826777.6 864803.6 Excavation 6-in Grab L050307PRS00 826736.6 864814.6 Root Zone Composite L050304PES00 826706.5 864784.6 Excavation 6-in Grab L050305PRS00 826777.6 864803.6 Root Zone Composite L050302PES00 826747.6 864773.6 Excavation 6-in Grab L050303PRS00 826706.5 864784.6 Root Zone Composite L050301PRS00 826747.6 864773.6 Root Zone Composite FSS SAMPLE & MEASUREMENT LOCATIONS & COORDINATES LSA 05 Barns and Cistern Open Land Area 03 Red Barn Area FSS Class 1 Hematite Decommissioning Project Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Revision: 10 Appendix P-4, Page 1 of 1 APPENDIX P-4 Measurement or Sample ID Northing**

(Y Axis)

Easting**

(X Axis)

Remarks / Notes

HDP-PR-FSS-721 Final Status Survey Data Evaluation Steps 8.3 Preliminary Data Review and 8.4 Calculation of the Sum-of-Fractions (SOF)

LSA 05-03 FSSDE Worksheets Uniform.xlsx/Ingrowth Data Eval 01/16/2018 Page 2 of 9 Enr.

SOFN Step 8.4.3 Result Uncertainty MDC Qualifier Net Result*

Corrected Result Result Corrected Result Uncertainty MDC Qualifier Result Uncertainty MDC Qualifier Net Result**

Corrected Result Result Uncertainty MDC Qualifier Result Uncertainty MDC Qualifier Result Uncertainty MDC Qualifier Enrichment

(%)

SOFN Step 8.4.3 Is Sample in the Root Stratum?

Is ROOT Sample SOF >

0.5?

root count excavation count surface count L050301PRS00 2.20 S

1.060 0.173 0.096 NA

-0.010 0.000

-0.040 0.000 0.024 0.240 U

1.370 0.216 0.184 NA 0.370 0.370 2.595 NA NA NA 0.14 0.190 1.240 U

1.11 0.483 1.240 U

2.0 0.21 ROOT good 1

L050302PES00 2.70 S

1.240 0.179 0.082 NA 0.170 0.170

-0.048 0.000 0.021 0.240 U

1.240 0.204 0.109 NA 0.240 0.240 2.615 NA NA NA 0.14 0.154 1.050 U

1.5 0.891 1.050 NA 1.5 0.23 ROOT good 1

L050303PRS00 3.88 S

1.110 0.160 0.078 NA 0.040 0.040

-0.064 0.000 0.072 0.231 U

1.140 0.180 0.143 NA 0.140 0.140 1.087 NA NA NA 0.05 0.156 0.995 U

0.926 0.390 0.995 U

0.9 0.10 ROOT good 1

L050304PES00 4.38 S

1.440 0.213 0.096 NA 0.370 0.370

-0.062 0.000 0.090 0.260 U

1.180 0.223 0.180 NA 0.180 0.180 7.242 NA NA NA 0.40 0.233 1.110 U

2.02 0.922 1.110 NA 3.0 0.34 ROOT good 1

L050305PRS00 0.65 S

1.060 0.152 0.074 NA

-0.010 0.000

-0.036 0.000 0.064 0.240 U

1.170 0.197 0.133 NA 0.170 0.170 3.187 NA NA NA 0.17 0.146 0.903 U

1.62 0.734 0.903 NA 1.7 0.11 ROOT good 1

L050306PES00 1.15 S

1.060 0.156 0.075 NA

-0.010 0.000 0.139 0.139 0.068 0.242 U

1.120 0.160 0.101 NA 0.120 0.120 0.836 NA NA NA 0.04 0.071 0.883 U

1.29 0.675 0.883 NA 0.5 0.08 ROOT good 1

L050307PRS00 2.74 S

1.200 0.183 0.081 NA 0.130 0.130 0.034 0.034 0.074 0.256 U

1.080 0.190 0.156 NA 0.080 0.080 3.453 NA NA NA 0.19 0.158 1.100 U

1.57 0.938 1.100 NA 1.8 0.14 ROOT good 1

L050308PES00 3.24 S

1.140 0.161 0.064 NA 0.070 0.070

-0.044 0.000 0.081 0.243 U

1.120 0.208 0.126 NA 0.120 0.120 2.056 NA NA NA 0.11 0.142 0.853 U

1.32 0.640 0.853 NA 1.3 0.12 ROOT good 1

L050309PRS00 0.29 S

0.969 0.141 0.067 NA

-0.101 0.000

-0.050 0.000 0.060 0.236 U

0.991 0.195 0.122 NA

-0.009 0.000 0.835 NA NA NA 0.03 0.123 0.818 U

1.44 0.637 0.818 NA 0.4 0.01 SURFACE good 1

L050310PES00 0.79 S

1.120 0.184 0.096 NA 0.050 0.050

-0.063 0.000 0.073 0.235 U

1.080 0.188 0.130 NA 0.080 0.080 1.885 NA NA NA 0.10 0.169 1.200 U

0.869 0.391 1.200 U

1.8 0.08 ROOT good 1

L050311PRS00 1.78 S

1.150 0.169 0.089 NA 0.080 0.080

-0.069 0.000 0.040 0.258 U

1.080 0.195 0.131 NA 0.080 0.080 2.945 NA NA NA 0.16 0.157 0.914 U

0.812 0.368 0.914 U

3.1 0.11 ROOT good 1

L050312PES00 2.28 S

1.100 0.153 0.078 NA 0.030 0.030

-0.082 0.000 0.032 0.249 U

1.150 0.184 0.115 NA 0.150 0.150 2.856 NA NA NA 0.15 0.149 0.920 U

1.35 0.736 0.920 NA 1.8 0.12 ROOT good 1

L050313PRS00 1.62 S

1.160 0.162 0.067 NA 0.090 0.090

-0.042 0.000 0.052 0.239 U

1.000 0.194 0.102 NA 0.000 0.000 3.095 NA NA NA 0.17 0.163 0.859 U

1.33 0.657 0.859 NA 2.0 0.07 ROOT good 1

L050314PES00 2.12 S

1.100 0.174 0.075 NA 0.030 0.030

-0.071 0.000 0.088 0.250 U

1.140 0.220 0.191 NA 0.140 0.140 3.718 NA NA NA 0.20 0.153 1.020 U

1.25 0.790 1.020 NA 2.5 0.12 ROOT good 1

L050315PRS00 0.58 S

1.040 0.149 0.063 NA

-0.030 0.000

-0.050 0.000 0.048 0.259 U

1.170 0.173 0.107 NA 0.170 0.170 2.364 NA NA NA 0.12 0.159 0.960 U

1.47 0.804 0.960 NA 1.3 0.11 ROOT good 1

L050316PES00 1.08 S

1.130 0.159 0.076 NA 0.060 0.060

-0.025 0.000 0.070 0.231 U

1.270 0.209 0.120 NA 0.270 0.270 0.634 NA NA NA 0.03 0.133 1.010 U

0.894 0.396 1.010 U

0.5 0.18 ROOT good 1

L050317PRS00 2.54 S

1.140 0.163 0.080 NA 0.070 0.070

-0.057 0.000 0.022 0.244 U

1.210 0.178 0.093 NA 0.210 0.210 0.922 NA NA NA 0.05 0.103 0.977 U

0.867 0.392 0.977 U

0.9 0.15 ROOT good 1

L050318PES00 3.04 S

1.030 0.148 0.061 NA

-0.040 0.000

-0.049 0.000 0.019 0.241 U

1.020 0.163 0.091 NA 0.020 0.020 2.078 NA NA NA 0.11 0.141 0.919 U

1.58 0.762 0.919 NA 1.1 0.03 ROOT good 1

L050319PRS00 1.59 S

1.170 0.168 0.079 NA 0.100 0.100

-0.056 0.000 0.083 0.224 U

1.100 0.175 0.138 NA 0.100 0.100 0.880 NA NA NA 0.04 0.140 0.961 U

0.86 0.380 0.961 U

0.8 0.11 ROOT good 1

L050320PES00 2.09 S

1.270 0.279 0.194 NA 0.200 0.200

-0.058 0.000 0.069 0.231 U

0.795 0.266 0.276 NA

-0.205 0.000 4.780 NA NA NA 0.26 0.299 2.240 U

2.35 1.760 2.240 NA 1.7 0.15 ROOT good 1

L050321PRS00 1.47 S

1.040 0.164 0.081 NA

-0.030 0.000 0.003 0.003 0.087 0.238 U

1.010 0.173 0.156 NA 0.010 0.010 1.528 NA NA NA 0.07 0.086 1.030 U

1.54 0.830 1.030 NA 0.8 0.02 ROOT good 1

L050322PES00 1.97 S

1.080 0.168 0.073 NA 0.010 0.010 0.001 0.001 0.068 0.236 U

1.070 0.180 0.051 NA 0.070 0.070 1.815 NA NA NA 0.09 0.170 1.110 U

1.36 0.900 1.110 NA 1.1 0.06 ROOT good 1

L050304PEQ00 4.38 Q

1.260 0.179 0.083 NA 0.190 0.190

-0.088 0.000 0.012 0.245 U

1.270 0.205 0.127 NA 0.270 0.270 1.737 NA NA NA 0.09 0.174 0.813 U

0.956 0.328 0.813 NA 1.5 0.25 good L050323PUB00 3.32 B

1.060 0.161 0.085 NA

-0.010 0.000 0.004 0.004 0.020 0.231 U

1.200 0.188 0.116 NA 0.200 0.200 3.973 NA NA NA 0.22 0.146 0.886 U

1.56 0.688 0.886 NA 2.1 0.13 good L050324PUB00 2.79 B

1.080 0.158 0.075 NA 0.010 0.010

-0.033 0.000 0.045 0.232 U

1.230 0.188 0.039 NA 0.230 0.230 1.214 NA NA NA 0.06 0.107 1.110 U

1.29 0.926 1.110 NA 0.7 0.14 good L050325PUB00 2.05 B

1.120 0.165 0.087 NA 0.050 0.050

-0.036 0.000 0.034 0.249 U

1.190 0.193 0.125 NA 0.190 0.190 2.303 NA NA NA 0.12 0.169 0.958 U

1.89 0.820 0.958 NA 1.0 0.15 good L050343PUB00 5.12 B

1.230 0.181 0.086 NA 0.160 0.160

-0.041 0.000 0.028 0.230 U

0.987 0.165 0.175 NA

-0.013 0.000 2.097 NA NA NA 0.10 0.160 0.948 U

2.02 0.794 0.948 NA 0.8 0.11 good L050344PUB00 3.92 B

1.070 0.174 0.101 NA 0.000 0.000

-0.042 0.000 0.072 0.238 U

1.160 0.205 0.124 NA 0.160 0.160 2.283 NA NA NA 0.12 0.177 0.986 U

1.78 0.827 0.986 NA 1.0 0.10 good L050345PUB00 3.10 B

1.240 0.166 0.060 NA 0.170 0.170

-0.043 0.000 0.061 0.253 U

0.882 0.140 0.144 NA

-0.118 0.000 5.971 NA NA NA 0.33 0.144 0.838 U

2.01 0.461 0.838 NA 2.5 0.14 good L050346PUB00 5.12 B

1.170 0.170 0.085 NA 0.100 0.100

-0.039 0.000 0.092 0.235 U

0.939 0.174 0.139 NA

-0.061 0.000 2.422 NA NA NA 0.12 0.130 0.925 U

1.97 0.786 0.925 NA 1.0 0.08 good L050347PUB00 3.92 B

1.240 0.173 0.070 NA 0.170 0.170

-0.029 0.000 0.061 0.233 U

1.100 0.186 0.116 NA 0.100 0.100 3.468 NA NA NA 0.19 0.137 0.862 U

0.888 0.343 0.862 NA 3.3 0.17 good L050348PUB00 3.10 B

1.070 0.171 0.094 NA 0.000 0.000 0.005 0.005 0.047 0.232 U

1.110 0.189 0.100 NA 0.110 0.110 5.203 NA NA NA 0.28 0.153 1.040 U

1.88 0.887 1.040 NA 2.3 0.10 good L050349PUB00 4.04 B

1.120 0.156 0.068 NA 0.050 0.050

-0.008 0.000 0.017 0.224 U

0.903 0.164 0.094 NA

-0.097 0.000 3.243 NA NA NA 0.18 0.152 0.808 U

1.37 0.612 0.808 NA 2.0 0.05 good L050350PUB00 5.11 B

1.280 0.175 0.073 NA 0.210 0.210

-0.048 0.000 0.019 0.231 U

1.160 0.183 0.095 NA 0.160 0.160 2.288 NA NA NA 0.12 0.158 0.928 U

1.54 0.753 0.928 NA 1.2 0.21 good L050351PUB00 5.02 B

1.170 0.160 0.068 NA 0.100 0.100

-0.042 0.000 0.021 0.212 U

1.180 0.191 0.106 NA 0.180 0.180 2.899 NA NA NA 0.15 0.163 0.976 U

1.79 0.850 0.976 NA 1.4 0.17 good 1.5 0.01 0.34 22 21 0

1 0.12 count tot 0.11 0.07 With ingrowth, use Ra226 bkg =

1.07 Th232 bkg =

1.0 Gross results in units of pCi/g

  • Background with ingrowth (1.07 pCi/g) subtracted from gross result U Qualifier: Result is less than the sample detection limit.

All uncertainty values are reported at the 2-sigma confidence level.

Sample ID Sample Start Depth (ft)

Type (Systematic, Bias, QC)

TestAmerica Analytical Results Step 8.3.2 Root Stratum SOF Verification (unexcavated/not backfilled only) Step 8.4.4a.1 Ra-226 Tc-99 Th-232 Inferred U-234 U-235 U-238 Systematic Median 0.398 Systematic Minimum 0.000 0.000 0.000 0.634 0.028 0.812 Systematic Maximum 0.370 0.139 0.370 7.242 NOTES:

    • Background (1.0 pCi/g) subtracted from gross result 0.045 0.000 0.120 0.095 2.221 0.115 1.340 0.387 Average Enrichme nt (%)

0.124 2.428 0.128 1.333 2.350 Systematic Mean 0.068 0.008 Systematic Standard Deviation 0.088 0.030 1.535 0.086

HDP-PR-FSS-721 Final Status Survey Data Evaluation Steps 8.3 Preliminary Data Review and 8.4 Calculation of the Sum-of-Fractions (SOF)

LSA 05-03 FSSDE Worksheets Uniform.xlsx/Ingrowth Data Eval 01/16/2018 Page 3 of 9 Use corrected net results for all DE calcs 721 Sec. 8.4.2 MDC SOF Step 8.1.1.c U-238/U235 Ratio U-234/U235 Ratio U-234 Enrichment 0.30 Step 8.4.1 DCLGW, Measure Tc-99, All SEAs 7.9 18.5 2.6 2.0 22.98 0.24 Uniform 10.9 18.9 2.6 1.5 19.89 0.25 U-234 195.4 17.2 20.2 1.1 0.9 20.06 0.28 U-235 51.6 5.1 18.2 7.2 3.0 20.20 0.22 U-238 168.8 9.5 18.7 3.2 1.7 16.93 0.22 Tc-99 25.1 35.1 22.7 0.8 0.5 20.07 0.26 Th-232 2.0 8.5 18.7 3.5 1.8 20.53 0.21 Ra-226 1.9 12.3 19.2 2.1 1.3 16.39 0.23 41.7 24.2 0.8 0.4 19.79 0.27 8.6 18.7 1.9 1.8 22.40 0.23 Step 8.4.5b 5.0 18.2 2.9 3.1 16.62 0.22 weighted SOFMEAN 0.12 8.8 18.7 2.9 1.8 17.17 0.20 SS RS ES 8.0 18.5 3.1 2.0 15.92 0.27 fractions 0.045454545 0.954545455 0

6.2 18.3 3.7 2.5 18.68 0.22 12.0 19.2 2.4 1.3 18.45 0.25 32.0 22.7 0.6 0.5 22.96 0.22 Step 8.4.5c SOFMEAN Re-use Backfill Material 19.0 20.2 0.9 0.9 19.70 0.20 0

Offsite borrow (No contribution) 14.9 19.6 2.1 1.1 18.01 0.24 20.1 20.6 0.9 0.8 19.76 0.52 9.2 18.7 4.8 1.7 41.99 0.26 Step 8.4.5e SOFMEAN Groundwater 20.7 20.6 1.5 0.8 21.18 0.21 0.16 14.7 19.6 1.8 1.1 21.76 0.22 10.4 18.9 1.7 1.5 15.40 0.22 7.3 18.5 4.0 2.1 16.37 0.22 Step 8.4.5g (<=1) 22.4 21.1 1.2 0.7 23.39 0.24 16.3 19.9 2.3 1.0 19.02 0.27 SOFMEAN, SU 0.28 PASS 19.8 20.6 2.1 0.8 19.49 0.25 15.5 19.9 2.3 1.0 19.58 0.21 6.2 18.3 6.0 2.5 15.35 0.24 16.1 19.9 2.4 1.0 18.36 0.21 4.6 18.2 3.5 3.3 15.65 0.23 6.6 18.4 5.2 2.3 19.12 0.19 7.8 18.5 3.2 2.0 14.97 0.21 13.1 19.4 2.3 1.2 18.00 0.22 11.8 19.1 2.9 1.4 18.61 Average Enrichment (%)

1.48 7.0 Infer U234 Step 8.3.4 Infer U-234 MDC using U-235 MDC

  • ratio of U-234:U-235

@ that sample's enrichment mrem Step 8.4.6 Calculate the dose contribution for the SU by multiplying SOFMEAN,SU (including contribution from Re-use backfill and Groundwater) by 25 mrem.

HDP-PR-FSS-721 Final Status Survey Data Evaluation Steps 8.3 Preliminary Data Review and 8.4 Calculation of the Sum-of-Fractions (SOF)

LSA 05-03 FSSDE Worksheets Uniform.xlsx/Ingrowth Data Eval 01/16/2018 Page 4 of 9 Ave Conc. Ra-226, SS Ave Conc. Tc-99, SS Ave Conc. Th-232, SS Ave Conc. U-234, SS Ave Conc. U-235, SS Ave Conc. U-238, SS 0.000 0.000 0.000 0.835 0.035 1.440 0.000 0.000 0.000 0.000 0.000 0.000 Ave Conc. Ra-226, RS Ave Conc. Tc-99, RS Ave Conc. Th-232, RS Ave Conc. U-234, RS Ave Conc. U-235, RS Ave Conc. U-238, RS 0.000 0.000 0.370 2.595 0.140 1.110 0.170 0.000 0.240 2.615 0.138 1.500 0.040 0.000 0.140 1.087 0.054 0.926 0.370 0.000 0.180 7.242 0.398 2.020 0.000 0.000 0.170 3.187 0.170 1.620 0.000 0.139 0.120 0.836 0.037 1.290 0.130 0.034 0.080 3.453 0.185 1.570 0.070 0.000 0.120 2.056 0.107 1.320 0.050 0.000 0.080 1.885 0.101 0.869 0.080 0.000 0.080 2.945 0.162 0.812 0.030 0.000 0.150 2.856 0.153 1.350 0.090 0.000 0.000 3.095 0.167 1.330 0.030 0.000 0.140 3.718 0.203 1.250 0.000 0.000 0.170 2.364 0.123 1.470 0.060 0.000 0.270 0.634 0.028 0.894 0.070 0.000 0.210 0.922 0.046 0.867 0.000 0.000 0.020 2.078 0.106 1.580 0.100 0.000 0.100 0.880 0.043 0.860 0.200 0.000 0.000 4.780 0.255 2.350 0.000 0.003 0.010 1.528 0.074 1.540 0.010 0.001 0.070 1.815 0.093 1.360 0.071 0.008 0.130 2.503 0.132 1.328 Ave Conc. Ra-226, ES Ave Conc. Tc-99, ES Ave Conc. Th-232, ES Ave Conc. U-234, ES Ave Conc. U-235, ES Ave Conc. U-238, ES 0.000 0.000 0.000 0.000 0.000 0.000

HDP-PR-FSS-721 Final Status Survey Data Evaluation Step 8.5 Performance of Statistical Tests LSA 05-03 FSSDE Worksheets Uniform.xlsx/Step 8.5.3 WRS Test 01/16/2018 Page 5 of 9 SAMPLE ID AREA (Reference, Survey Unit)

Gross SOF (Xi,ref, Yi,SU,gross) Step 8.5.3a ADJUSTED SOF (Zi) Step 8.5.3b RANKS Step 8.5.3d REFERENCE AREA RANKS 9574-SS-140910-01-01 Reference 1.31 2.310 52 52 9574-SS-140910-01-02 Reference 1.18 2.179 43 43 9574-SS-140910-01-03 Reference 1.06 2.064 38 38 9574-SS-140910-01-04 Reference 1.10 2.101 39 39 9574-SS-140910-01-05 Reference 1.29 2.293 51 51 9574-SS-140910-01-07 Reference 1.34 2.339 53 53 9574-SS-140910-01-08 Reference 1.15 2.154 42 42 9574-SS-140910-01-09 Reference 1.18 2.182 44 44 9574-SS-140910-01-10 Reference 1.23 2.227 49 49 9574-SS-140910-01-11 Reference 1.38 2.380 54 54 9574-SS-140910-01-12 Reference 1.05 2.055 37 37 9574-SS-140910-01-13 Reference 0.94 1.941 27 27 9574-SS-140910-01-14 Reference 1.12 2.119 40 40 9574-SS-140910-01-15 Reference 1.15 2.152 41 41 9574-SS-140910-01-16 Reference 1.03 2.028 34 34 9574-SS-140910-01-17 Reference 0.44 1.443 23 23 9574-SS-140910-01-18 Reference 1.19 2.188 46 46 9574-SS-140910-01-20 Reference 0.76 1.757 24 24 9574-SS-140910-01-21 Reference 1.02 2.023 33 33 9574-SS-140910-01-22 Reference 1.02 2.018 32 32 9574-SS-140910-01-23 Reference 1.00 2.002 29 29 9574-SS-140910-01-24 Reference 0.87 1.873 26 26 9574-SS-140910-01-25 Reference 1.04 2.040 36 36 9574-SS-140910-01-26 Reference 0.96 1.959 28 28 9574-SS-140910-01-27 Reference 1.20 2.204 47 47 9574-SS-140910-01-28 Reference 1.01 2.007 31 31 9574-SS-140910-01-29 Reference 1.22 2.223 48 48 9574-SS-140910-01-30 Reference 1.03 2.035 35 35 9574-SS-140910-01-31 Reference 1.00 2.005 30 30 9574-SS-140910-01-32 Reference 0.86 1.865 25 25 9574-SS-140910-01-33 Reference 1.24 2.238 50 50 Min adjusted bkg SOF:

9574-SS-140910-01-34 Reference 1.19 2.185 45 45 1.44 L050301PRS00 Survey Unit 1.26 1.264 20 0

No WRS test necessary L050302PES00 Survey Unit 1.30 1.296 21 0

No WRS test necessary L050303PRS00 Survey Unit 1.16 1.164 10 0

No WRS test necessary L050304PES00 Survey Unit 1.40 1.402 22 0

No WRS test necessary L050305PRS00 Survey Unit 1.17 1.171 12 0

No WRS test necessary L050306PES00 Survey Unit 1.14 1.136 7

0 No WRS test necessary L050307PRS00 Survey Unit 1.20 1.203 17 0

No WRS test necessary L050308PES00 Survey Unit 1.18 1.179 16 0

No WRS test necessary L050309PRS00 Survey Unit 1.02 1.017 1

0 No WRS test necessary L050310PES00 Survey Unit 1.14 1.144 8

0 No WRS test necessary L050311PRS00 Survey Unit 1.17 1.166 11 0

No WRS test necessary L050312PES00 Survey Unit 1.18 1.176 14 0

No WRS test necessary L050313PRS00 Survey Unit 1.14 1.136 6

0 No WRS test necessary L050314PES00 Survey Unit 1.18 1.176 15 0

No WRS test necessary L050315PRS00 Survey Unit 1.15 1.154 9

0 No WRS test necessary L050316PES00 Survey Unit 1.24 1.238 19 0

No WRS test necessary L050317PRS00 Survey Unit 1.21 1.213 18 0

No WRS test necessary L050318PES00 Survey Unit 1.07 1.072 3

0 No WRS test necessary L050319PRS00 Survey Unit 1.17 1.174 13 0

No WRS test necessary L050320PES00 Survey Unit 1.11 1.107 4

0 No WRS test necessary L050321PRS00 Survey Unit 1.07 1.071 2

0 No WRS test necessary L050322PES00 Survey Unit 1.12 1.123 5

0 No WRS test necessary Rank Sums 1485 1232 Wr Step 8.5.3e

  1. Reference Area Measurements m

32

  1. Survey Unit Measurements n

22 Total Number of Measurements Step 8.5.3c N

54

) percentile of a standard normal distribution (MARSSIM Pg. I-10) z 1.645 WRS Critical Value (MARSSIM Pg. I-10, Eq. I.1)

CV 974

= 0.05 TEST:

PASS Step 8.5.3f WRS TEST

HDP-PR-FSS-701 Final Status Survey Plan Development Appendix P-1 Step 8. Calculate the Number of Samples in the Statistical Survey Population LSA 05-03 FSSDE Worksheets Uniform.xlsx/Retrospective Sample Size 01/16/2018 Page 6 of 9 MARSSIM Table 5.1 MARSSIM Table 5.2, = 0.05, = 0.10

/

Pr (or )

Z1- (or Z1-)

0.1 0.528182 0.005 2.576 0.2 0.556223 0.01 2.326 0.3 0.583985 0.015 2.241 0.4 0.611335 0.025 1.960 0.5 0.638143 0.05 1.645

0.6 0.664290 0.10 1.282

0.7 0.689665 0.15 1.036 0.8 0.714167 0.2 0.842 0.9 0.737710 0.25 0.674 1.0 0.760217 0.30 0.524 1.1 0.781627 1.2 0.801892 1.3 0.820978 1.4 0.838864 1.5 0.855541 1.6 0.871014 1.7 0.885299 1.8 0.898420 1.9 0.910413 2.0 0.921319 2.25 0.944167 2.5 0.961428 2.75 0.974067 3.0 0.983039 3.5 0.993329 4.0 0.997658 4.01 1.000000 Uniform DCGL Criteria Evaluation N/2 Value Verification Isotope(s)

SOF (Ra/Tc/Th/Iso U)

St. Dev.

0.07 DCGLSOF 1

LBGR (Mean) 0.12 Shift 0.88 Relative Shift (/)

11.97 MARSSIM Table 5.1 (Pr) 1.000000 N

12 Verification Check SUFFICIENT MEASUREMENTS "N/2" Corresponds to the number of survey unit measurement locations required for the WRS Test N + 20%

14.4 N/2 8

FSS N/2 11

Survey Unit No.:

Activity (xi)

MDC Activity (xi)

MDC L050304PES00 L050304PEQ00 Ra-226 1.44 0.0964 1.26 0.0828 1.35 1.9 0.18 0.269 0.403 N

L050304PES00 L050304PEQ00 Tc-99

-0.0618 0.26

-0.0875 0.245

-0.07465 25.1 NA 3.552 5.321 NA L050304PES00 L050304PEQ00 Th-232 1.18 0.18 1.27 0.127 1.225 2.0 0.090 0.283 0.424 N

L050304PES00 L050304PEQ00 U-2341 7.242 NA 1.737 NA 4.490 195.4 5.505 27.649 41.425 N

L050304PES00 L050304PEQ00 U-235 0.40 1.11 0.09 0.813 0.245 51.6 NA 7.301 10.939 NA L050304PES00 L050304PEQ00 U-238 2.02 1.11 0.956 0.813 1.488 168.8 1.064 23.885 35.786 N

Comments:

1. U-234 is inferred, no MDC available.
2. Duplicate assessment is not necessary if the result of either sample is < MDC.

Performed by: Thomas Yardy Reviewed by: Clark Evers Date:

Date:

Quality Record Survey Unit

Description:

LSA 05-03 Red Barn Area FORM HDP-PR-FSS-703-1 FIELD DUPLICATE SAMPLE ASSESSMENT Statistic2 Warning Limit Control Limit Statistic Exceeds Limit?

(Y/N)

Average Activity ( )

(pCi/g)

Nuclide DCGL (pCi/g)

Sample ID Field Duplicate Sample ID Radionuclide Sample (pCi/g)

Field Duplicate Sample (pCi/g)

Revision: 2 Page 1 of 1 Hematite Decommissioning Project Procedure: HDP-PR-FSS-703, Final Status Survey Quality Control

LSA 05-03 Sys SOF 0.2 0.2 0.1 0.3 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.0 0.1 0.1 0.0 0.1

v4.65.2 Last updated 8 March 2017 at 15:51 by W. Clark Evers Descriptives N

22

Mean 95% CI Mean SE SD Variance Skewness Kurtosis LSA 05-03 Sys SOF 0.12 0.09 to 0.15 0.016 0.07 0.01 1.3 2.87

Minimum 1st quartile Median 98.31% CI 3rd quartile Maximum IQR LSA 05-03 Sys SOF 0.01 0.08 0.11 0.08 to 0.15 0.15 0.3 0.07 Distribution: LSA 05-03 Sys SOF SOFn Only A1:A23 0

2 4

6 8

10 12 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Frequency LSA 05-03 Sys SOF 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

LSA 05-03 Sys SOF