ANALYTICAL REPORT TestAmerica Laboratories, Inc.
TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-16779-2 Client Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
For:
Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Mr. Martin Swanson Authorized for release by:
4/28/2016 12:42:25 PM Ivan Vania, Project Manager II (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.
Results relate only to the items tested and the sample(s) as received by the laboratory.
1 2
3 4
5 6
7 8
9 10 11
Table of Contents Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
TestAmerica Job ID: 160-16779-2 Page 2 of 15 Cover Page..............................................
1 Table of Contents.........................................
2 Case Narrative...........................................
3 Chain of Custody..........................................
4 Receipt Checklists.........................................
5 Definitions/Glossary.......................................
6 Method Summary.........................................
7 Sample Summary.........................................
8 Client Sample Results......................................
9 QC Sample Results........................................
13 QC Association Summary...................................
15 1
2 3
4 5
6 7
8 9
10 11
Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-16779-2 Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Job ID: 160-16779-2 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: HDP RFP-CBA-022 (7 DAY TAT)
Report Number: 160-16779-2 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.
TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.
The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.
Calculations are performed before rounding to avoid round-off errors in calculated results.
All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.
All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %
solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.
This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.
RECEIPT The samples were received on 4/4/2016 11:00 AM; the samples arrived in good condition, properly preserved and, where required, on ice.
The temperature of the cooler at receipt was 20.0º C.
RADIUM-226 BY GAMMA SPEC (21 DAY INGROWTH)
Samples L05-04-14-T-S-S-00 (160-16779-1), L05-04-15-T-R-S-00 (160-16779-2), L05-04-17-T-S-S-00 (160-16779-3),
L05-04-18-T-R-S-00 (160-16779-4), L05-04-20-T-S-S-00 (160-16779-5), L05-04-21-T-R-S-00 (160-16779-6), L05-04-22-T-E-S-00 (160-16779-7) and L05-04-22-T-E-Q-00 (160-16779-8) were analyzed for Radium-226 by gamma spec (21 day ingrowth) in accordance with EPA GA_01_R. The samples were leached on 04/04/2016, prepared on 04/06/2016 and analyzed on 04/27/2016.
No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
TestAmerica St. Louis Page 3 of 15 1
2 3
4 5
6 7
8 9
10 11
Page 4 of 15 1
2 3
4 5
6 7
8 9
10 11 Procedure HDP-PR-Q~ -006, Chain of Custody Hematite Decommissioning Project !Revision: 4
]
I Page 14 Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a perlon from each organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified I
before the sample is released for use or analysis and send the completed CoC to HDP.
l Chain of Cutody ID No_ I F-040116-02 Page 1/1 Project Name:
Westinghouse Electric Company Contact Person:
Clark Evers Phone Number:
314-810-3336 Sampler Name Mike Dekeyser Sample ID L05-04-14-T-S-S-OO L05-04-15-T-R-S-OO L05-04-l 7-T-S-S-OO L05-04-l 8-T-R-S-OO L05-04-20-T-S-S-OO LOS-04-21-T-R-S-OO LOS-04-22-T-E-S-OO L05-04-22-T-E-Q-OO CompanyName: t,,Jf;L Received by:
Company Name:
Date 4/1/2016 4/1/2016 4/1 /2016 4/1/2016 4/1/2016 4/1/2016 4/1/2016 4/1/2016 Time 9:10 14:00 9:15 14:55 9:25 9:40 10:10 10:10 Date/Time q-'-f.rJ (...
oqot)
Date/Time Date/Time
'"t-+- l<e 1 *.,~
Matrix s
s s
s s
s s
s Date/Time
,.._ - 'f- (f.
O~l1N Date/Time Laborato Name:
TA-MO Laboratory Address:
13715 Rider Trail North
~
"§ Phone No.
,::; 314-298-8566 0 u
]l Laboratory Contact Person:
~ Ivan Vania Phone No-708-870-8453 Tum Around Time Rush (7 days)
Remarks LSA05-04 1 LSA 05-04 1 LSA 05-04 1 LSA 05-04 1 LSA 05-04 1 LSA 05-04 LSA 05-04 1 ILSA 05-04 Cooler Temperature:
Total 8 I
Ambient Cooler ID: !Shipper and Number:
401-02 Comments: NIA V eri:fied By:
--r7>*= /.,, /~.K t/---3-4
-0 0
co
()
0 C
.s;;;
()
CD........
<O 6
~
~ ~ --.:.__:_:__-....!...!...__:_.:._______:' *i-------
Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-16779-2 Login Number: 16779 Question Answer Comment Creator: Dedner, Connie L List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.
True The cooler's custody seal, if present, is intact.
N/A Sample custody seals, if present, are intact.
True The cooler or samples do not appear to have been compromised or tampered with.
N/A Samples were received on ice.
True Cooler Temperature is acceptable.
True Cooler Temperature is recorded.
True COC is present.
True COC is filled out in ink and legible.
True COC is filled out with all pertinent information.
True Is the Field Sampler's name present on COC?
True There are no discrepancies between the containers received and the COC.
True Samples are received within Holding Time (excluding tests with immediate HTs)
True Sample containers have legible labels.
True Containers are not broken or leaking.
True Sample collection date/times are provided.
True Appropriate sample containers are used.
True Sample bottles are completely filled.
True Sample Preservation Verified.
True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is
<6mm (1/4").
True Multiphasic samples are not present.
True Samples do not require splitting or compositing.
N/A Residual Chlorine Checked.
TestAmerica St. Louis Page 5 of 15 1
2 3
4 5
6 7
8 9
10 11
Definitions/Glossary TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Qualifiers Rad Qualifier Description U
Result is less than the sample detection limit.
Qualifier Glossary These commonly used abbreviations may or may not be present in this report.
Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation
%R Percent Recovery CFL Contains Free Liquid CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)
Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)
NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown)
PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
TestAmerica St. Louis Page 6 of 15 1
2 3
4 5
6 7
8 9
10 11
Method Summary TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method Method Description Laboratory Protocol DOE GA-01-R Radium-226 & Other Gamma Emitters (GS)
TAL SL Protocol
References:
DOE = U.S. Department of Energy Laboratory
References:
TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 7 of 15 1
2 3
4 5
6 7
8 9
10 11
Sample Summary TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID Client Sample ID Received Collected Matrix 160-16779-1 L05-04-14-T-S-S-00 Solid 04/01/16 09:10 04/04/16 11:00 160-16779-2 L05-04-15-T-R-S-00 Solid 04/01/16 14:00 04/04/16 11:00 160-16779-3 L05-04-17-T-S-S-00 Solid 04/01/16 09:15 04/04/16 11:00 160-16779-4 L05-04-18-T-R-S-00 Solid 04/01/16 14:55 04/04/16 11:00 160-16779-5 L05-04-20-T-S-S-00 Solid 04/01/16 09:25 04/04/16 11:00 160-16779-6 L05-04-21-T-R-S-00 Solid 04/01/16 09:40 04/04/16 11:00 160-16779-7 L05-04-22-T-E-S-00 Solid 04/01/16 10:10 04/04/16 11:00 160-16779-8 L05-04-22-T-E-Q-00 Solid 04/01/16 10:10 04/04/16 11:00 TestAmerica St. Louis Page 8 of 15 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID: 160-16779-1 Client Sample ID: L05-04-14-T-S-S-00 Matrix: Solid Date Collected: 04/01/16 09:10 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.01 (2+/-)
0.146 (2+/-)
1 04/27/16 13:40 04/06/16 10:29 pCi/g 0.0834 RL MDC 0.104 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.342 0.415 0.396 1.19 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0691 0.130 0.0959 0.838 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0615 0.140 0.0717 0.929 Lead 212 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0604 0.130 0.0826 0.965 Lead 214 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.441 2.10 1.08 17.6 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 13:40 1
1.05 0.221 0.214 U
0.496 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0691 1.00 0.130 0.0959 0.838 Radium 226 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0834 0.146 0.104 1.01 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.773 0.277 0.266 U
0.740 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.176 0.113 0.109 0.293 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0914 0.0541 0.0541 U
-0.000986 Americium 241 pCi/g 04/06/16 10:29 04/27/16 13:40 1
4.10 2.34 2.32 U
2.64 Protactinium 234m Tl-208 0.273 0.0399 0.0490 0.0326 pCi/g 04/06/16 10:29 04/27/16 13:40 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
Lab Sample ID: 160-16779-2 Client Sample ID: L05-04-15-T-R-S-00 Matrix: Solid Date Collected: 04/01/16 14:00 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.14 (2+/-)
0.201 (2+/-)
1 04/27/16 13:41 04/06/16 10:29 pCi/g 0.157 RL MDC 0.164 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.450 0.505 0.482 1.46 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.0750 0.174 0.125 1.16 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.0800 0.162 0.0916 1.03 Lead 212 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.0823 0.175 0.119 1.23 Lead 214 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.402 2.45 1.41 19.5 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.910 0.581 0.578 U
0.603 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.0750 1.00 0.174 0.125 1.16 Radium 226 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.157 0.201 0.164 1.14 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.871 0.319 0.306 U
0.867 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.261 0.126 0.126 U
0.0758 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 13:41 1
0.122 0.0730 0.0729 U
-0.0264 Americium 241 pCi/g 04/06/16 10:29 04/27/16 13:41 1
6.29 3.72 3.72 U
2.09 Protactinium 234m Pb-210 1.63 0.647 0.675 0.816 pCi/g 04/06/16 10:29 04/27/16 13:41 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
Tl-208 0.384 0.0524 0.0659 0.0360 pCi/g 04/06/16 10:29 04/27/16 13:41 1
TestAmerica St. Louis Page 9 of 15 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID: 160-16779-3 Client Sample ID: L05-04-17-T-S-S-00 Matrix: Solid Date Collected: 04/01/16 09:15 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 0.228 (2+/-)
0.0675 (2+/-)
1 04/27/16 13:40 04/06/16 10:29 pCi/g 0.0402 RL MDC 0.0633 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.179 0.179 0.175 0.350 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0317 0.0596 0.0494 0.320 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0386 0.0482 0.0398 0.210 Lead 212 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0371 0.0602 0.0498 0.326 Lead 214 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.174 0.805 0.576 5.49 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.583 0.162 0.161 U
0.171 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0317 1.00 0.0596 0.0494 0.320 Radium 226 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0402 0.0675 0.0633 0.228 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.470 0.331 0.315 0.985 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.128 0.103 0.0967 0.339 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 13:40 1
0.0530 0.0321 0.0320 U
0.0229 Americium 241 pCi/g 04/06/16 10:29 04/27/16 13:40 1
2.49 1.32 1.32 U
0.138 Protactinium 234m Pb-210 0.850 0.342 0.356 0.428 pCi/g 04/06/16 10:29 04/27/16 13:40 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
Tl-208 0.0964 0.0243 0.0262 0.0208 pCi/g 04/06/16 10:29 04/27/16 13:40 1
Lab Sample ID: 160-16779-4 Client Sample ID: L05-04-18-T-R-S-00 Matrix: Solid Date Collected: 04/01/16 14:55 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 0.920 (2+/-)
0.215 (2+/-)
1 04/27/16 14:14 04/06/16 10:29 pCi/g 0.156 RL MDC 0.194 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.349 0.500 0.464 1.77 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.0879 0.167 0.131 0.998 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.0904 0.171 0.103 1.05 Lead 212 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.0968 0.191 0.134 1.31 Lead 214 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.361 2.21 1.32 17.4 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.993 0.591 0.590 U
0.315 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.0879 1.00 0.167 0.131 0.998 Radium 226 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.156 0.215 0.194 0.920 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.939 0.609 0.593 1.32 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.272 0.226 0.226 U
-0.0985 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 14:14 1
0.112 0.0662 0.0662 U
0.00134 Americium 241 pCi/g 04/06/16 10:29 04/27/16 14:14 1
6.79 3.77 3.77 U
0.689 Protactinium 234m Tl-208 0.400 0.0555 0.0692 0.0379 pCi/g 04/06/16 10:29 04/27/16 14:14 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
TestAmerica St. Louis Page 10 of 15 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID: 160-16779-5 Client Sample ID: L05-04-20-T-S-S-00 Matrix: Solid Date Collected: 04/01/16 09:25 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 0.702 (2+/-)
0.124 (2+/-)
1 04/27/16 14:15 04/06/16 10:29 pCi/g 0.0751 RL MDC 0.101 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.215 0.260 0.250 0.677 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0557 0.107 0.0800 0.683 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0539 0.109 0.0640 0.677 Lead 212 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0650 0.116 0.0777 0.825 Lead 214 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.309 1.43 0.851 11.3 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.916 0.246 0.244 U
0.291 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0557 1.00 0.107 0.0800 0.683 Radium 226 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0751 0.124 0.101 0.702 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.637 0.272 0.241 1.22 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.178 0.120 0.115 0.325 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0827 0.0491 0.0491 U
0.00866 Americium 241 pCi/g 04/06/16 10:29 04/27/16 14:15 1
3.88 2.25 2.21 4.22 Protactinium 234m Tl-208 0.188 0.0377 0.0424 0.0304 pCi/g 04/06/16 10:29 04/27/16 14:15 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
Lab Sample ID: 160-16779-6 Client Sample ID: L05-04-21-T-R-S-00 Matrix: Solid Date Collected: 04/01/16 09:40 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.04 (2+/-)
0.177 (2+/-)
1 04/27/16 14:15 04/06/16 10:29 pCi/g 0.118 RL MDC 0.143 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.470 0.362 0.347 0.987 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0674 0.142 0.102 0.956 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0617 0.145 0.0740 0.967 Lead 212 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0694 0.130 0.0827 0.962 Lead 214 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.283 2.02 1.09 16.7 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.997 0.275 0.271 U
0.443 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0674 1.00 0.142 0.102 0.956 Radium 226 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.118 0.177 0.143 1.04 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.672 0.263 0.246 0.883 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.222 0.120 0.120 U
0.0687 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 14:15 1
0.0764 0.0450 0.0450 U
0.00168 Americium 241 pCi/g 04/06/16 10:29 04/27/16 14:15 1
4.76 2.72 2.72 U
0.761 Protactinium 234m Tl-208 0.302 0.0457 0.0554 0.0349 pCi/g 04/06/16 10:29 04/27/16 14:15 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
TestAmerica St. Louis Page 11 of 15 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Lab Sample ID: 160-16779-7 Client Sample ID: L05-04-22-T-E-S-00 Matrix: Solid Date Collected: 04/01/16 10:10 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 0.882 (2+/-)
0.143 (2+/-)
1 04/27/16 15:23 04/06/16 10:29 pCi/g 0.106 RL MDC 0.111 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.385 0.454 0.432 1.34 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.0730 0.133 0.100 0.846 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.0684 0.151 0.0818 0.978 Lead 212 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.0640 0.120 0.0714 0.925 Lead 214 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.194 1.99 1.02 16.7 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 15:23 1
1.07 0.228 0.223 U
0.435 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.0730 1.00 0.133 0.100 0.846 Radium 226 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.106 0.143 0.111 0.882 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.799 0.277 0.267 U
0.705 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.243 0.144 0.144 U
0.0487 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 15:23 1
0.0964 0.0578 0.0577 U
0.0244 Americium 241 pCi/g 04/06/16 10:29 04/27/16 15:23 1
4.60 2.02 1.99 U
3.19 Protactinium 234m Tl-208 0.299 0.0455 0.0551 0.0339 pCi/g 04/06/16 10:29 04/27/16 15:23 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
Lab Sample ID: 160-16779-8 Client Sample ID: L05-04-22-T-E-Q-00 Matrix: Solid Date Collected: 04/01/16 10:10 Date Received: 04/04/16 11:00 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 0.972 (2+/-)
0.187 (2+/-)
1 04/27/16 15:22 04/06/16 10:29 pCi/g 0.113 RL MDC 0.159 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.296 0.364 0.342 1.20 Bismuth 212 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.0834 0.150 0.117 0.912 Bismuth 214 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.0683 0.152 0.0807 0.991 Lead 212 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.0671 0.147 0.0978 1.06 Lead 214 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.220 2.05 1.13 16.8 Potassium 40 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.872 0.414 0.407 U
0.712 Protactinium 231 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.0834 1.00 0.150 0.117 0.912 Radium 226 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.113 0.187 0.159 0.972 Thorium 232 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.794 0.278 0.271 U
0.619 Thorium 234 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.229 0.137 0.137 U
0.0717 Uranium 235 pCi/g 04/06/16 10:29 04/27/16 15:22 1
0.0976 0.0583 0.0583 U
0.0187 Americium 241 pCi/g 04/06/16 10:29 04/27/16 15:22 1
4.69 3.45 3.40 5.68 Protactinium 234m Pb-210 1.62 0.626 0.654 0.777 pCi/g 04/06/16 10:29 04/27/16 15:22 1
(2+/-)
(2+/-)
MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.
Uncert.
Tl-208 0.356 0.0477 0.0603 0.0347 pCi/g 04/06/16 10:29 04/27/16 15:22 1
TestAmerica St. Louis Page 12 of 15 1
2 3
4 5
6 7
8 9
10 11
QC Sample Results TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Client Sample ID: Method Blank Lab Sample ID: MB 160-244684/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 248012 Prep Batch: 244684 Actinium 228 Analyte U
1 04/27/16 15:56 04/06/16 10:29 pCi/g 0.0444 MDC RL 0.0254 0.0253 (2+/-)
(2+/-)
MB 0.01339 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.
Count Uncert.
Total 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.130 0.0749 0.0748 U
0.04229 Bismuth 212 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0335 0.0200 0.0200 U
0.002566 Bismuth 214 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0231 0.0263 0.0263 U
-0.003714 Lead 212 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0299 0.0470 0.0470 U
-0.006331 Lead 214 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.164 2.28 2.28 U
-0.05688 Potassium 40 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.292 0.155 0.155 U
-0.0009372 Protactinium 231 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0335 1.00 0.0200 0.0200 U
0.002566 Radium 226 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0444 0.0254 0.0253 U
0.01339 Thorium 232 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.274 0.0209 0.0209 U
0.01415 Thorium 234 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0593 0.000605 0.000605 U
-0.0001865 Uranium 235 1
04/27/16 15:56 04/06/16 10:29 pCi/g 0.0221 0.0125 0.0125 U
0.002849 Americium 241 1
04/27/16 15:56 04/06/16 10:29 pCi/g 2.35 13.7 13.7 U
-0.3414 Protactinium 234m Other Detected Radionuclide None MB (2+/-)
(2+/-)
MDC RL pCi/g 04/06/16 10:29 04/27/16 15:56 1
MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.
Count Uncert.
Total Radionuclides Other Detected Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-244684/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 248014 Prep Batch: 244684 Americium 241 Analyte 116 87 101 101.9 101 10.6 0.502 RL MDC (2+/-)
LCS LCS pCi/g Unit Result Qual
%Rec Added Spike Limits
%Rec.
Uncert.
Total Cesium 137 34.0 34.06 3.57 0.172 pCi/g 100 87 - 120 Cobalt 60 31.4 31.15 3.15 0.104 pCi/g 99 87 - 115 Client Sample ID: Duplicate Lab Sample ID: 160-16778-A-1-G DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 248009 Prep Batch: 244684 Actinium 228 Analyte 1
0.28 1.169 1.07 0.195 0.159 RL MDC (2+/-)
DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.
Total RER RER Bismuth 212 1.36 1.533 0.531 0.450 pCi/g 0.17 1
Bismuth 214 1.27 1.065 0.177 0.0932 pCi/g 0.58 1
Lead 212 1.07 1.040 0.170 0.0917 pCi/g 0.08 1
Lead 214 1.33 1.299 0.184 0.0866 pCi/g 0.09 1
Potassium 40 18.9 18.49 2.36 0.512 pCi/g 0.08 1
Protactinium 231 0.606 U 0.5927 U 0.254 1.33 pCi/g 0.03 1
Radium 226 1.27 1.065 0.177 1.00 0.0932 pCi/g 0.58 1
Thorium 232 1.07 1.169 0.195 0.159 pCi/g 0.28 1
Thorium 234 1.05 1.105 0.353 0.944 pCi/g 0.08 1
Uranium 235 0.307 0.2470 0.195 0.245 pCi/g 0.17 1
Americium 241 0.0181 U
-0.00127 9
U 0.0724 0.122 pCi/g 0.15 1
TestAmerica St. Louis Page 13 of 15 1
2 3
4 5
6 7
8 9
10 11
QC Sample Results TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)
Client Sample ID: Duplicate Lab Sample ID: 160-16778-A-1-G DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 248009 Prep Batch: 244684 Protactinium 234m Analyte 1
0.54 U
1.984 6.09 3.88 6.59 RL MDC (2+/-)
DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.
Total RER RER Tl-208 1
0.08 0.3591 0.349 0.0683 0.0441 RL MDC (2+/-)
DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.
RER RER Total Other Detected Radionuclides TestAmerica St. Louis Page 14 of 15 1
2 3
4 5
6 7
8 9
10 11
QC Association Summary TestAmerica Job ID: 160-16779-2 Client: Westinghouse Electric Company LLC Project/Site: HDP RFP-CBA-022 (7 DAY TAT)
Rad Leach Batch: 244065 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-16778-A-1-G DU Duplicate Total/NA Solid Dry and Grind 160-16779-1 L05-04-14-T-S-S-00 Total/NA Solid Dry and Grind 160-16779-2 L05-04-15-T-R-S-00 Total/NA Solid Dry and Grind 160-16779-3 L05-04-17-T-S-S-00 Total/NA Solid Dry and Grind 160-16779-4 L05-04-18-T-R-S-00 Total/NA Solid Dry and Grind 160-16779-5 L05-04-20-T-S-S-00 Total/NA Solid Dry and Grind 160-16779-6 L05-04-21-T-R-S-00 Total/NA Solid Dry and Grind 160-16779-7 L05-04-22-T-E-S-00 Total/NA Solid Dry and Grind 160-16779-8 L05-04-22-T-E-Q-00 Total/NA Prep Batch: 244684 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-21 244065 160-16778-A-1-G DU Duplicate Total/NA Solid Fill_Geo-21 244065 160-16779-1 L05-04-14-T-S-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-2 L05-04-15-T-R-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-3 L05-04-17-T-S-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-4 L05-04-18-T-R-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-5 L05-04-20-T-S-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-6 L05-04-21-T-R-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-7 L05-04-22-T-E-S-00 Total/NA Solid Fill_Geo-21 244065 160-16779-8 L05-04-22-T-E-Q-00 Total/NA Solid Fill_Geo-21 LCS 160-244684/2-A Lab Control Sample Total/NA Solid Fill_Geo-21 MB 160-244684/1-A Method Blank Total/NA TestAmerica St. Louis Page 15 of 15 1
2 3
4 5
6 7
8 9
10 11