ML18019A711

From kanterella
Jump to navigation Jump to search
Westinghouse Hematite Decommissioning Project - Final Status Survey Final Report Volume 3, Chapter 16, Survey Area Release Record for Land Survey Area 05, Survey Units 01, 02, 03 and 04, Revision 1, J4091-1 Uds Level 2 Report Final Report
ML18019A711
Person / Time
Site: 07000036
(SNM-0033)
Issue date: 10/18/2013
From: Vania I
TestAmerica Labs - St. Louis, Westinghouse
To: Swanson M
Office of Nuclear Material Safety and Safeguards, Westinghouse
Shared Package
ML18019A532 List: ... further results
References
HEM-18-2 160-4091-1
Download: ML18019A711 (21)


Text

ANALYTICAL REPORT TestAmerica Laboratories, Inc.

TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-4091-1 Client Project/Site: RFP-CBA-022 (7 DAY TAT)

For:

Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by:

10/18/2013 2:48:43 PM Ivan Vania, Project Manager I (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.

Results relate only to the items tested and the sample(s) as received by the laboratory.

1 2

3 4

5 6

7 8

9 10 11 12

Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

TestAmerica Job ID: 160-4091-1 Page 2 of 21 Cover Page..............................................

1 Table of Contents.........................................

2 Case Narrative...........................................

3 Chain of Custody..........................................

5 Receipt Checklists.........................................

6 Definitions/Glossary.......................................

7 Method Summary.........................................

8 Sample Summary.........................................

9 Client Sample Results......................................

10 QC Sample Results........................................

15 QC Association Summary...................................

19 Tracer Carrier Summary....................................

21 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4091-1 Project/Site: RFP-CBA-022 (7 DAY TAT)

Job ID: 160-4091-1 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (7 DAY TAT)

Report Number: 160-4091-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.

TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.

The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.

Calculations are performed before rounding to avoid round-off errors in calculated results.

All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.

All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %

solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.

This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.

RECEIPT The samples were received on 10/11/2013; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 2.0 C.

TECHNETIUM-99 (ICPMS)

Samples L050343PUB00 (160-4091-1), L050344PUB00 (160-4091-2), L050345PUB00 (160-4091-3), L050346PUB00 (160-4091-4),

L050347PUB00 (160-4091-5) and L050348PUB00 (160-4091-6) were analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A. The samples were prepared on 10/15/2013 and 10/16/2013 and analyzed on 10/15/2013 and 10/17/2013.

No difficulties were encountered during the Tc-99 analysis. All quality control parameters were within the acceptance limits.

PERCENT SOLIDS Samples L050343PUB00 (160-4091-1), L050344PUB00 (160-4091-2), L050345PUB00 (160-4091-3), L050346PUB00 (160-4091-4),

L050347PUB00 (160-4091-5) and L050348PUB00 (160-4091-6) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 10/14/2013.

TestAmerica St. Louis Page 3 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4091-1 Project/Site: RFP-CBA-022 (7 DAY TAT)

Job ID: 160-4091-1 (Continued)

Laboratory: TestAmerica St. Louis (Continued)

No difficulties were encountered during the % solids analysis. All quality control parameters were within the acceptance limits.

CESIUM-137 & OTHER GAMMA EMITTERS (GS)

Samples L050343PUB00 (160-4091-1), L050344PUB00 (160-4091-2), L050345PUB00 (160-4091-3), L050346PUB00 (160-4091-4),

L050347PUB00 (160-4091-5) and L050348PUB00 (160-4091-6) were analyzed for Cesium-137 & Other Gamma Emitters (GS) in accordance with DOE GA-01-R. The samples were leached on 10/14/2013, and prepared and analyzed on 10/16/2013.

Preparation Batch 79170:

The reporting limit for thorium-234 was not met due to insufficient sample weight available for analysis. Analytical results are reported with the MDC achieved. L050346PUB00 (160-4091-4)

Radium-226 is reported in these samples at the clients request. Radium-226 is reported from the 609.31 keV line of bismuth-214.

Because the samples have not had a 21-day ingrowth, the activity for radium-226 is an estimated value and may be biased low. This bias is caused by the disruption of secular equilibrium between radium-226 and bismuth-214 by the loss of radon-222 during sample preparation. (160-4091-1 DU), (LCS 160-79170/2-A), (MB 160-79170/1-A), L050343PUB00 (160-4091-1), L050344PUB00 (160-4091-2),

L050345PUB00 (160-4091-3), L050346PUB00 (160-4091-4), L050347PUB00 (160-4091-5), L050348PUB00 (160-4091-6)

No other difficulties were encountered during the Gamma spec analysis. All other quality control parameters were within the acceptance limits.

TestAmerica St. Louis Page 4 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Page 5 of 21 1

2 3

4 5

6 7

8 9

10 11 12 Procedure HDP-PR-QA-006, Chain o(Cu.stody Hematite Decommissioning Project Revision: 3 I

Page I ofl Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP.

Chain of Cutodv ID No_

F-101013-01 Pa2:e 1/1 Reauested Analysis Laborato.-v Name:

Project Name:

TA-MO

\\0 Westinghouse Electric Company N

N Contact Person:

-* : ~

Laboratory Address:

Gerald Rood

'8 13715 Rider Trail North

~

0 C

Phone Number:

  • ea Phone No_

I bJJ E

314-810-3382

.s 0

314-298-8566

~

u Sampler Name

'El Laboratory Contact Person:

"O I Andrew Schooley

§:

E

~ Joe Walker

~

l

~

Phone No_

u.* g I

g d

ll.)

708-870-8453 0

Q.

Q.

00..

00 Turn Around Time Q I>

u c,j "f -O'i: E Rush (7 days)

0.

"O\\ ]

Sample ID Date Time

.Matrix s

0 "c)',

Remarks 0

C::,..

~ t-'< *,

u L050343PUBOO 10/9/2013 16:05 s

C X

X X

1 LSA-o<- 0~

{<., ;Q' L050344PUBOO 10/9/2013 16:15 s

C X

X X

1

'J

L050345PUBOO 10/9/2013 16:25 s

C X

X X

1 I

L050346PUBOO 10/9/2013 16:10 s

C X

X X

1 L050347PUBOO 10/9/2013 16:20 s

C X

X X

1

\\.V L050348PUBOO 10/9/2013 16:30 s

C X

X X

1 L.SA-oS-, n3

(<. '-ti <:.

Relinquished by: C...

~

Date/Time Receiv~y:

/?~

Date/Time Total Cooler Temperature:

~ [ 0-/f--t 3

,/"",t.,,., :, - --

-~

~

6 Amhie,nt Comoany Name: W CL--

( (,..6 (

,, Company Name:

ifj.,.v,<o\\O Cooler ID: Shipper and Number:

Cross 4> ads-1 OJ 0-01 Received bv:

Date/Time

~~dby:/d D,ate/Time Comments: Please re-analyze samples after 21-day ingrowth

- ~u'"t,bc~ period.

Company Name:

.,, Company N~~

(-

i/7'""9.

\\

\\ l Relinquished by:

Date/Time

~t;ive~~

Date/Time

, --~,

c'-'-<<-r s Verified By:

Company Name:

Co~a:ny Name:

c,:.<r5 /

~

'~°"

~

()

~

Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-4091-1 Login Number: 4091 Question Answer Comment Creator: Daniels, Brian J List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.

True The cooler's custody seal, if present, is intact.

N/A Sample custody seals, if present, are intact.

True The cooler or samples do not appear to have been compromised or tampered with.

True Samples were received on ice.

True Cooler Temperature is acceptable.

True Cooler Temperature is recorded.

True COC is present.

True COC is filled out in ink and legible.

True COC is filled out with all pertinent information.

True Is the Field Sampler's name present on COC?

True There are no discrepancies between the containers received and the COC.

True Samples are received within Holding Time.

True Sample containers have legible labels.

True Containers are not broken or leaking.

True Sample collection date/times are provided.

True Appropriate sample containers are used.

True Sample bottles are completely filled.

True Sample Preservation Verified.

True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is

<6mm (1/4").

True Multiphasic samples are not present.

True Samples do not require splitting or compositing.

N/A Residual Chlorine Checked.

TestAmerica St. Louis Page 6 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Definitions/Glossary TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Qualifiers Rad Qualifier Description U

Indicates the analyte was analyzed for but not detected.

Qualifier Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation

%R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)

Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)

NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown)

PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)

RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)

TEQ Toxicity Equivalent Quotient (Dioxin)

TestAmerica St. Louis Page 7 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Method Summary TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method Method Description Laboratory Protocol SW846 6020A Metals (ICP/MS), Tc-99 TAL SL EPA Moisture Percent Moisture TAL SL SW846 6020A Metals (ICP/MS), Tc-99 in Activity TAL SL DOE GA-01-R Cesium-137 & Other Gamma Emitters (GS)

TAL SL Protocol

References:

DOE = U.S. Department of Energy EPA = US Environmental Protection Agency SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.

Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 8 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Sample Summary TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID Client Sample ID Received Collected Matrix 160-4091-1 L050343PUB00 Solid 10/09/13 16:05 10/11/13 17:45 160-4091-2 L050344PUB00 Solid 10/09/13 16:15 10/11/13 17:45 160-4091-3 L050345PUB00 Solid 10/09/13 16:25 10/11/13 17:45 160-4091-4 L050346PUB00 Solid 10/09/13 16:10 10/11/13 17:45 160-4091-5 L050347PUB00 Solid 10/09/13 16:20 10/11/13 17:45 160-4091-6 L050348PUB00 Solid 10/09/13 16:30 10/11/13 17:45 TestAmerica St. Louis Page 9 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4091-1 Client Sample ID: L050343PUB00 Matrix: Solid Date Collected: 10/09/13 16:05 Percent Solids: 85.6 Date Received: 10/11/13 17:45 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000067 0.000020 mg/Kg

10/15/13 09:15 10/15/13 17:56 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0412 U

(2+/-)

0.0275 (2+/-)

1 10/15/13 17:56 10/15/13 09:15 pCi/g 0.230 1.35 RL MDC

-0.0236 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 09:15 10/15/13 17:56 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 87 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.14 (2+/-)

0.182 (2+/-)

1 10/16/13 21:38 10/16/13 11:32 pCi/g 0.0839 RL MDC 0.140 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.101 0.0600 0.0600 U

0.00335 Americium 241 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.321 0.331 0.320 0.830 Bismuth 212 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.0676 0.118 0.0927 0.704 Bismuth 214 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.0534 0.160 0.0712 1.11 Lead 212 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.0726 0.131 0.0905 0.908 Lead 214 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.267 2.49 1.18 21.4 Potassium 40 pCi/g 10/16/13 11:32 10/16/13 21:38 1

1.15 0.211 0.207 U

0.380 Protactinium 231 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.0676 1.00 0.118 0.0927 0.704 Radium 226 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.768 1.00 0.620 0.594 1.71 Thorium 234 pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.244 0.150 0.149 U

0.129 Uranium 235 pCi/g 10/16/13 11:32 10/16/13 21:38 1

4.76 2.87 2.86 U

2.03 Protactinium 234m pCi/g 10/16/13 11:32 10/16/13 21:38 1

0.0839 0.182 0.140 1.14 Thorium 232 Tl-208 0.369 0.0418 0.0567 0.0261 pCi/g 10/16/13 11:32 10/16/13 21:38 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-4091-2 Client Sample ID: L050344PUB00 Matrix: Solid Date Collected: 10/09/13 16:15 Percent Solids: 82.2 Date Received: 10/11/13 17:45 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000069 0.000021 mg/Kg

10/15/13 09:15 10/15/13 18:15 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0416 U

(2+/-)

0.0721 (2+/-)

1 10/15/13 18:15 10/15/13 09:15 pCi/g 0.238 1.39 RL MDC

-0.0629 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 09:15 10/15/13 18:15 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 87 TestAmerica St. Louis Page 10 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4091-2 Client Sample ID: L050344PUB00 Matrix: Solid Date Collected: 10/09/13 16:15 Date Received: 10/11/13 17:45 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.12 (2+/-)

0.158 (2+/-)

1 10/16/13 18:38 10/16/13 11:32 pCi/g 0.0836 RL MDC 0.109 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.0951 0.0566 0.0566 U

-0.0107 Americium 241 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.339 0.415 0.385 1.51 Bismuth 212 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.0709 0.123 0.0951 0.753 Bismuth 214 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.0554 0.160 0.0704 1.11 Lead 212 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.0660 0.115 0.0690 0.890 Lead 214 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.377 2.38 1.17 20.2 Potassium 40 pCi/g 10/16/13 11:32 10/16/13 18:38 1

1.05 0.645 0.642 U

-0.570 Protactinium 231 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.0709 1.00 0.123 0.0951 0.753 Radium 226 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.785 1.00 0.652 0.620 1.91 Thorium 234 pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.182 0.142 0.142 U

0.156 Uranium 235 pCi/g 10/16/13 11:32 10/16/13 18:38 1

4.59 2.67 2.67 U

1.05 Protactinium 234m pCi/g 10/16/13 11:32 10/16/13 18:38 1

0.0836 0.158 0.109 1.12 Thorium 232 Tl-208 0.374 0.0440 0.0586 0.0294 pCi/g 10/16/13 11:32 10/16/13 18:38 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-4091-3 Client Sample ID: L050345PUB00 Matrix: Solid Date Collected: 10/09/13 16:25 Percent Solids: 83.8 Date Received: 10/11/13 17:45 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000074 0.000022 mg/Kg

10/15/13 09:15 10/15/13 18:19 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0433 U

(2+/-)

0.0609 (2+/-)

1 10/15/13 18:19 10/15/13 09:15 pCi/g 0.253 1.48 RL MDC

-0.0492 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 09:15 10/15/13 18:19 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 81 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.04 (2+/-)

0.179 (2+/-)

1 10/16/13 19:27 10/16/13 11:32 pCi/g 0.0917 RL MDC 0.144 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.0985 0.0591 0.0590 U

0.0326 Americium 241 pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.403 0.453 0.431 1.35 Bismuth 212 pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.0728 0.127 0.101 0.738 Bismuth 214 pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.0576 0.152 0.0734 1.03 Lead 212 pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.0598 0.118 0.0837 0.794 Lead 214 pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.370 2.45 1.31 20.2 Potassium 40 pCi/g 10/16/13 11:32 10/16/13 19:27 1

1.06 0.225 0.221 U

0.389 Protactinium 231 pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.0728 1.00 0.127 0.101 0.738 Radium 226 TestAmerica St. Louis Page 11 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4091-3 Client Sample ID: L050345PUB00 Matrix: Solid Date Collected: 10/09/13 16:25 Date Received: 10/11/13 17:45 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)

Analyte Thorium 234 1.85 (2+/-)

0.725 (2+/-)

1 10/16/13 19:27 10/16/13 11:32 pCi/g 0.888 1.00 RL MDC 0.699 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.236 0.151 0.150 U

0.204 Uranium 235 pCi/g 10/16/13 11:32 10/16/13 19:27 1

5.30 3.15 3.14 U

1.89 Protactinium 234m pCi/g 10/16/13 11:32 10/16/13 19:27 1

0.0917 0.179 0.144 1.04 Thorium 232 Tl-208 0.347 0.0495 0.0612 0.0366 pCi/g 10/16/13 11:32 10/16/13 19:27 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-4091-4 Client Sample ID: L050346PUB00 Matrix: Solid Date Collected: 10/09/13 16:10 Percent Solids: 83.8 Date Received: 10/11/13 17:45 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000069 0.000021 mg/Kg

10/15/13 09:15 10/15/13 18:23 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0392 U

(2+/-)

0.0916 (2+/-)

1 10/15/13 18:23 10/15/13 09:15 pCi/g 0.235 1.37 RL MDC

-0.0799 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 09:15 10/15/13 18:23 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 87 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.05 (2+/-)

0.201 (2+/-)

1 10/16/13 19:26 10/16/13 11:32 pCi/g 0.212 RL MDC 0.170 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.120 0.0715 0.0714 U

0.0239 Americium 241 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.473 0.478 0.463 1.17 Bismuth 212 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.0791 0.136 0.111 0.764 Bismuth 214 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.0696 0.161 0.0839 1.06 Lead 212 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.0870 0.138 0.0973 0.935 Lead 214 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.306 2.53 1.44 20.4 Potassium 40 pCi/g 10/16/13 11:32 10/16/13 19:26 1

1.35 0.376 0.368 U

0.701 Protactinium 231 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.0791 1.00 0.136 0.111 0.764 Radium 226 pCi/g 10/16/13 11:32 10/16/13 19:26 1

1.12 1.00 0.356 0.347 U

0.771 Thorium 234 pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.277 0.165 0.165 U

0.0576 Uranium 235 pCi/g 10/16/13 11:32 10/16/13 19:26 1

6.32 3.74 3.74 U

2.18 Protactinium 234m pCi/g 10/16/13 11:32 10/16/13 19:26 1

0.212 0.201 0.170 1.05 Thorium 232 Tl-208 0.342 0.0557 0.0661 0.0427 pCi/g 10/16/13 11:32 10/16/13 19:26 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

TestAmerica St. Louis Page 12 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4091-5 Client Sample ID: L050347PUB00 Matrix: Solid Date Collected: 10/09/13 16:20 Percent Solids: 83.6 Date Received: 10/11/13 17:45 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000068 0.000020 mg/Kg

10/15/13 09:15 10/15/13 18:27 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0294 U

(2+/-)

0.0609 (2+/-)

1 10/15/13 18:27 10/15/13 09:15 pCi/g 0.233 1.36 RL MDC

-0.0537 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 09:15 10/15/13 18:27 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 88 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.11 (2+/-)

0.158 (2+/-)

1 10/16/13 19:28 10/16/13 11:32 pCi/g 0.0728 RL MDC 0.109 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.0928 0.0550 0.0550 U

0.00139 Americium 241 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.347 0.337 0.308 1.31 Bismuth 212 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.0600 0.116 0.0836 0.779 Bismuth 214 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.0527 0.157 0.0671 1.10 Lead 212 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.0662 0.115 0.0704 0.869 Lead 214 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.199 2.38 1.09 20.6 Potassium 40 pCi/g 10/16/13 11:32 10/16/13 19:28 1

1.06 0.657 0.653 U

-0.677 Protactinium 231 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.0600 1.00 0.116 0.0836 0.779 Radium 226 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.799 1.00 0.649 0.632 1.42 Thorium 234 pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.211 0.132 0.129 0.272 Uranium 235 pCi/g 10/16/13 11:32 10/16/13 19:28 1

4.89 2.79 2.79 U

0.777 Protactinium 234m pCi/g 10/16/13 11:32 10/16/13 19:28 1

0.0728 0.158 0.109 1.11 Thorium 232 Tl-208 0.372 0.0458 0.0599 0.0333 pCi/g 10/16/13 11:32 10/16/13 19:28 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-4091-6 Client Sample ID: L050348PUB00 Matrix: Solid Date Collected: 10/09/13 16:30 Percent Solids: 82.7 Date Received: 10/11/13 17:45 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000068 0.000020 mg/Kg

10/16/13 13:42 10/17/13 11:30 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.00487 U

(2+/-)

0.0472 (2+/-)

1 10/17/13 11:30 10/16/13 13:42 pCi/g 0.232 1.36 RL MDC 0.0424 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/16/13 13:42 10/17/13 11:30 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 TestAmerica St. Louis Page 13 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4091-6 Client Sample ID: L050348PUB00 Matrix: Solid Date Collected: 10/09/13 16:30 Date Received: 10/11/13 17:45 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.01 (2+/-)

0.157 (2+/-)

1 10/16/13 21:36 10/16/13 11:32 pCi/g 0.113 RL MDC 0.119 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.100 0.0597 0.0597 U

-0.00475 Americium 241 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.351 0.457 0.429 1.49 Bismuth 212 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.0661 0.119 0.0891 0.753 Bismuth 214 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.0761 0.141 0.0722 0.937 Lead 212 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.0681 0.124 0.0875 0.845 Lead 214 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.342 2.37 1.14 20.3 Potassium 40 pCi/g 10/16/13 11:32 10/16/13 21:36 1

1.15 0.703 0.699 U

-0.623 Protactinium 231 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.0661 1.00 0.119 0.0891 0.753 Radium 226 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.865 1.00 0.710 0.690 1.60 Thorium 234 pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.207 0.148 0.146 0.229 Uranium 235 pCi/g 10/16/13 11:32 10/16/13 21:36 1

4.25 1.97 1.96 U

1.02 Protactinium 234m pCi/g 10/16/13 11:32 10/16/13 21:36 1

0.113 0.157 0.119 1.01 Thorium 232 Tl-208 0.317 0.0401 0.0518 0.0278 pCi/g 10/16/13 11:32 10/16/13 21:36 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

TestAmerica St. Louis Page 14 of 21 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 Client Sample ID: Method Blank Lab Sample ID: MB 160-79001/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 79001 RL MDL Technetium 99 ND 0.000052 0.000016 mg/Kg 10/15/13 09:15 10/15/13 17:48 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79001/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 79001 Technetium 99 0.00234 0.00222 mg/Kg 95 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: L050343PUB00 Lab Sample ID: 160-4091-1 MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 79001 Technetium 99 ND 0.00272 0.00271 mg/Kg 100 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: L050343PUB00 Lab Sample ID: 160-4091-1 MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 79001 Technetium 99 ND 0.00272 0.00263 mg/Kg 97 75 - 125 3

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD Client Sample ID: Method Blank Lab Sample ID: MB 160-79104/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79515 Prep Batch: 79104 RL MDL Technetium 99 ND 0.000051 0.000015 mg/Kg 10/16/13 08:57 10/17/13 09:46 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79104/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79515 Prep Batch: 79104 Technetium 99 0.00235 0.00232 mg/Kg 99 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: Matrix Spike Lab Sample ID: 160-4122-A-21-B MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 79515 Prep Batch: 79104 Technetium 99 0.00025 0.00269 0.00294 mg/Kg 100 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4122-A-21-C MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 79515 Prep Batch: 79104 Technetium 99 0.00025 0.00270 0.00285 mg/Kg 96 75 - 125 3

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD TestAmerica St. Louis Page 15 of 21 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Client Sample ID: Method Blank Lab Sample ID: MB 160-79001/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 79001 Technetium 99 Analyte U

1 10/15/13 17:48 10/15/13 09:15 pCi/g 0.179 MDC 1.05 RL 0.00682

-0.00540 (2+/-)

(2+/-)

MB

-0.03949 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Carrier Re 30 - 110 10/15/13 09:15 10/15/13 17:48 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 95 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79001/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 79001 Technetium 99 Analyte 120 80 95 37.96 40.1 3.87 1.06 0.182 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 94 LCS Client Sample ID: L050343PUB00 Lab Sample ID: 160-4091-1 MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 79001 Technetium 99 Analyte 125 75 100 46.44 46.5

-0.0412 U

5.43 1.39 0.237 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 84 MS Client Sample ID: L050343PUB00 Lab Sample ID: 160-4091-1 MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 79001 Technetium 99 Analyte 1

0.14 125 75 97 45.03 46.6

-0.0412 U

5.00 1.37 0.235 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 85 MSD Client Sample ID: Method Blank Lab Sample ID: MB 160-79104/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79516 Prep Batch: 79104 Technetium 99 Analyte U

1 10/17/13 09:46 10/16/13 08:57 pCi/g 0.174 MDC 1.01 RL 0.0225 0.0223 (2+/-)

(2+/-)

MB 0.02084 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total TestAmerica St. Louis Page 16 of 21 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued)

Client Sample ID: Method Blank Lab Sample ID: MB 160-79104/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79516 Prep Batch: 79104 Carrier Re 30 - 110 10/16/13 08:57 10/17/13 09:46 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 99 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79104/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79516 Prep Batch: 79104 Technetium 99 Analyte 120 80 99 39.77 40.2 4.25 1.04 0.178 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 96 LCS Client Sample ID: Matrix Spike Lab Sample ID: 160-4122-A-21-B MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 79516 Prep Batch: 79104 Technetium 99 Analyte 125 75 100 50.32 46.1 4.35 6.36 1.28 0.219 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 90 MS Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4122-A-21-C MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 79516 Prep Batch: 79104 Technetium 99 Analyte 1

0.11 125 75 96 48.87 46.2 4.35 6.94 1.28 0.219 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 90 MSD Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Client Sample ID: Method Blank Lab Sample ID: MB 160-79170/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79141 Prep Batch: 79170 Actinium 228 Analyte U

1 10/16/13 18:39 10/16/13 11:32 pCi/g 0.0587 MDC RL 0.00331 0.00331 (2+/-)

(2+/-)

MB 0.001732 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.0216 0.0127 0.0126 U

0.006589 Americium 241 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.160 0.0707 0.0707 U

0.0000 Bismuth 212 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.0378 0.0308 0.0308 U

-0.004299 Bismuth 214 TestAmerica St. Louis Page 17 of 21 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)

Client Sample ID: Method Blank Lab Sample ID: MB 160-79170/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79141 Prep Batch: 79170 Lead 212 Analyte U

1 10/16/13 18:39 10/16/13 11:32 pCi/g 0.0240 MDC RL 0.0229 0.0229 (2+/-)

(2+/-)

MB

-0.004602 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.0321 0.0102 0.0102 U

-0.001444 Lead 214 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.190 3.30 3.30 U

-0.08250 Potassium 40 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.309 0.175 0.175 U

-0.06497 Protactinium 231 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.0378 1.00 0.0308 0.0308 U

-0.004299 Radium 226 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.260 1.00 0.132 0.132 U

0.003917 Thorium 234 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.0670 0.0240 0.0240 U

0.008918 Uranium 235 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.888 0.618 0.618 U

0.1758 Protactinium 234m 1

10/16/13 18:39 10/16/13 11:32 pCi/g 0.0587 0.00331 0.00331 U

0.001732 Thorium 232 Other Detected Radionuclide None MB (2+/-)

(2+/-)

MDC RL pCi/g 10/16/13 11:32 10/16/13 18:39 1

MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Radionuclides Other Detected Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79170/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79152 Prep Batch: 79170 Americium 241 Analyte 116 87 96 94.24 97.7 9.80 0.462 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Cesium 137 31.6 30.95 3.24 0.200 0.139 pCi/g 98 87 - 120 Cobalt 60 24.3 23.45 2.37 0.0807 pCi/g 96 87 - 115 Client Sample ID: L050343PUB00 Lab Sample ID: 160-4091-1 DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 79141 Prep Batch: 79170 Actinium 228 Analyte 1

0.04 1.132 1.14 0.192 0.0912 RL MDC (2+/-)

DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.

Total RER RER Americium 241 0.00335 U

-0.01618 U

0.0643 0.108 pCi/g 0.16 1

Bismuth 212 0.830 1.320 0.362 0.288 pCi/g 0.71 1

Bismuth 214 0.704 0.7608 0.121 0.0703 pCi/g 0.24 1

Lead 212 1.11 0.9921 0.148 0.0771 pCi/g 0.38 1

Lead 214 0.908 0.8289 0.131 0.0832 pCi/g 0.30 1

Potassium 40 21.4 21.33 2.50 0.434 pCi/g 0.02 1

Protactinium 231 0.380 U

0.3719 U

0.330 0.864 pCi/g 0.02 1

Radium 226 0.704 0.7608 0.121 1.00 0.0703 pCi/g 0.24 1

Thorium 234 1.71 1.534 0.763 1.00 0.900 pCi/g 0.12 1

Uranium 235 0.129 U

0.07760 U

0.0901 0.168 pCi/g 0.22 1

Protactinium 234m 2.03 U

3.540 U

2.01 4.82 pCi/g 0.31 1

Thorium 232 1.14 1.132 0.192 0.0912 pCi/g 0.04 1

TestAmerica St. Louis Page 18 of 21 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Metals Prep Batch: 79001 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4091-1 L050343PUB00 Total/NA Solid None 160-4091-1 MS L050343PUB00 Total/NA Solid None 160-4091-1 MSD L050343PUB00 Total/NA Solid None 160-4091-2 L050344PUB00 Total/NA Solid None 160-4091-3 L050345PUB00 Total/NA Solid None 160-4091-4 L050346PUB00 Total/NA Solid None 160-4091-5 L050347PUB00 Total/NA Solid None LCS 160-79001/2-A Lab Control Sample Total/NA Solid None MB 160-79001/1-A Method Blank Total/NA Prep Batch: 79104 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4091-6 L050348PUB00 Total/NA Solid None 160-4122-A-21-B MS Matrix Spike Total/NA Solid None 160-4122-A-21-C MSD Matrix Spike Duplicate Total/NA Solid None LCS 160-79104/2-A Lab Control Sample Total/NA Solid None MB 160-79104/1-A Method Blank Total/NA Analysis Batch: 79106 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 79001 160-4091-1 L050343PUB00 Total/NA Solid 6020A 79001 160-4091-1 MS L050343PUB00 Total/NA Solid 6020A 79001 160-4091-1 MSD L050343PUB00 Total/NA Solid 6020A 79001 160-4091-2 L050344PUB00 Total/NA Solid 6020A 79001 160-4091-3 L050345PUB00 Total/NA Solid 6020A 79001 160-4091-4 L050346PUB00 Total/NA Solid 6020A 79001 160-4091-5 L050347PUB00 Total/NA Solid 6020A 79001 LCS 160-79001/2-A Lab Control Sample Total/NA Solid 6020A 79001 MB 160-79001/1-A Method Blank Total/NA Analysis Batch: 79515 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 79104 160-4091-6 L050348PUB00 Total/NA Solid 6020A 79104 160-4122-A-21-B MS Matrix Spike Total/NA Solid 6020A 79104 160-4122-A-21-C MSD Matrix Spike Duplicate Total/NA Solid 6020A 79104 LCS 160-79104/2-A Lab Control Sample Total/NA Solid 6020A 79104 MB 160-79104/1-A Method Blank Total/NA General Chemistry Analysis Batch: 78648 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Moisture 160-4086-A-1 DU Duplicate Total/NA Solid Moisture 160-4091-1 L050343PUB00 Total/NA Solid Moisture 160-4091-2 L050344PUB00 Total/NA Solid Moisture 160-4091-3 L050345PUB00 Total/NA Solid Moisture 160-4091-4 L050346PUB00 Total/NA Solid Moisture 160-4091-5 L050347PUB00 Total/NA Solid Moisture 160-4091-6 L050348PUB00 Total/NA TestAmerica St. Louis Page 19 of 21 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Rad Leach Batch: 78661 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-4091-1 L050343PUB00 Total/NA Solid Dry and Grind 160-4091-1 DU L050343PUB00 Total/NA Solid Dry and Grind 160-4091-2 L050344PUB00 Total/NA Solid Dry and Grind 160-4091-3 L050345PUB00 Total/NA Solid Dry and Grind 160-4091-4 L050346PUB00 Total/NA Solid Dry and Grind 160-4091-5 L050347PUB00 Total/NA Solid Dry and Grind 160-4091-6 L050348PUB00 Total/NA Prep Batch: 79001 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4091-1 L050343PUB00 Total/NA Solid None 160-4091-1 MS L050343PUB00 Total/NA Solid None 160-4091-1 MSD L050343PUB00 Total/NA Solid None 160-4091-2 L050344PUB00 Total/NA Solid None 160-4091-3 L050345PUB00 Total/NA Solid None 160-4091-4 L050346PUB00 Total/NA Solid None 160-4091-5 L050347PUB00 Total/NA Solid None LCS 160-79001/2-A Lab Control Sample Total/NA Solid None MB 160-79001/1-A Method Blank Total/NA Prep Batch: 79104 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4091-6 L050348PUB00 Total/NA Solid None 160-4122-A-21-B MS Matrix Spike Total/NA Solid None 160-4122-A-21-C MSD Matrix Spike Duplicate Total/NA Solid None LCS 160-79104/2-A Lab Control Sample Total/NA Solid None MB 160-79104/1-A Method Blank Total/NA Prep Batch: 79170 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-0 78661 160-4091-1 L050343PUB00 Total/NA Solid Fill_Geo-0 78661 160-4091-1 DU L050343PUB00 Total/NA Solid Fill_Geo-0 78661 160-4091-2 L050344PUB00 Total/NA Solid Fill_Geo-0 78661 160-4091-3 L050345PUB00 Total/NA Solid Fill_Geo-0 78661 160-4091-4 L050346PUB00 Total/NA Solid Fill_Geo-0 78661 160-4091-5 L050347PUB00 Total/NA Solid Fill_Geo-0 78661 160-4091-6 L050348PUB00 Total/NA Solid Fill_Geo-0 LCS 160-79170/2-A Lab Control Sample Total/NA Solid Fill_Geo-0 MB 160-79170/1-A Method Blank Total/NA TestAmerica St. Louis Page 20 of 21 1

2 3

4 5

6 7

8 9

10 11 12

Tracer/Carrier Summary TestAmerica Job ID: 160-4091-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Prep Type: Total/NA Matrix: Solid Lab Sample ID Client Sample ID (30-110)

Re 87 160-4091-1 Percent Yield (Acceptance Limits)

L050343PUB00 84 160-4091-1 MS L050343PUB00 85 160-4091-1 MSD L050343PUB00 87 160-4091-2 L050344PUB00 81 160-4091-3 L050345PUB00 87 160-4091-4 L050346PUB00 88 160-4091-5 L050347PUB00 90 160-4091-6 L050348PUB00 90 160-4122-A-21-B MS Matrix Spike 90 160-4122-A-21-C MSD Matrix Spike Duplicate 94 LCS 160-79001/2-A Lab Control Sample 96 LCS 160-79104/2-A Lab Control Sample 95 MB 160-79001/1-A Method Blank 99 MB 160-79104/1-A Method Blank Tracer/Carrier Legend Re = Re TestAmerica St. Louis Page 21 of 21 1

2 3

4 5

6 7

8 9

10 11 12