ML18019A689

From kanterella
Jump to navigation Jump to search
Westinghouse Hematite Decommissioning Project - Final Status Survey Final Report Volume 3, Chapter 16, Survey Area Release Record for Land Survey Area 05, Survey Units 01, 02, 03 and 04, Revision 1, J4164-1 Uds Level 2 Report Final Report
ML18019A689
Person / Time
Site: 07000036
(SNM-0033)
Issue date: 10/22/2013
From: Vania I
TestAmerica Labs - St. Louis, Westinghouse
To: Swanson M
Office of Nuclear Material Safety and Safeguards, Westinghouse
Shared Package
ML18019A532 List: ... further results
References
HEM-18-2 60-4164-1
Download: ML18019A689 (14)


Text

{{#Wiki_filter:ANALYTICAL REPORT TestAmerica Laboratories, Inc. TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-4164-1 Client Project/Site: RFP-CBA-022 (7 DAY TAT) For: Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by: 10/22/2013 3:59:07 PM Ivan Vania, Project Manager I (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature. Results relate only to the items tested and the sample(s) as received by the laboratory. 1 2 3 4 5 6 7 8 9 10 11 12

Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) TestAmerica Job ID: 160-4164-1 Page 2 of 14 Cover Page.............................................. 1 Table of Contents......................................... 2 Case Narrative........................................... 3 Chain of Custody.......................................... 5 Receipt Checklists......................................... 6 Definitions/Glossary....................................... 7 Method Summary......................................... 8 Sample Summary......................................... 9 Client Sample Results...................................... 10 QC Sample Results........................................ 11 QC Association Summary................................... 13 Tracer Carrier Summary.................................... 14 1 2 3 4 5 6 7 8 9 10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4164-1 Project/Site: RFP-CBA-022 (7 DAY TAT) Job ID: 160-4164-1 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (7 DAY TAT) Report Number: 160-4164-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required. TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below. The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory. Calculations are performed before rounding to avoid round-off errors in calculated results. All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below. All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a % solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client. This laboratory report is confidential and is intended for the sole use of TestAmerica and its client. RECEIPT The samples were received on 10/18/2013; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 3.0 C. TECHNETIUM-99 (ICPMS) Samples L0501119TUB0 (160-4164-1) and L0501120TUB0 (160-4164-2) were analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A. The samples were prepared and analyzed on 10/21/2013. No difficulties were encountered during the Tc-99 analysis. All quality control parameters were within the acceptance limits. its. PERCENT SOLIDS Samples L0501119TUB0 (160-4164-1) and L0501120TUB0 (160-4164-2) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 10/21/2013. TestAmerica St. Louis Page 3 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4164-1 Project/Site: RFP-CBA-022 (7 DAY TAT) Job ID: 160-4164-1 (Continued) Laboratory: TestAmerica St. Louis (Continued) No difficulties were encountered during the % solids analysis. All quality control parameters were within the acceptance limits. TestAmerica St. Louis Page 4 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Page 5 of 14 1 2 3 4 5 6 7 8 9 10 11 12 Procedure BDP-PR-QA-006, Chain of Custody Hematite Decommissioning Project Revision: 3 I Page 1 ofl Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP. ~ Chain of Cutodv ID No_ F-101813-01 Pa2e 1/1

  • i'*':"

Ri =ested.Analvsis ~- --'.. Laboratory Name: Project Name: ~,,, ~ ir***** 1*,,, ~;;:* TA-MO Westinghouse Electric Company ~i 07" '! A~ 1:;~ {*i~* Contact Person: ~I ~ i>1 ~J~ Laboratory Address: Gerald Rood c8 'i 13715 Rider Trail North ni,, ~~j ~ Phone Number: l'c ~

  • .; Phone No.

314-810-3382 ~ .r

:\\*<

E 314-298-8566 E i. !~ 0 u Sampler Name ~ Laboratory Contact Person: Andrew Schooley s f1!~hi ~,'~ ~ Joe Walker ~ Phone No. ~\\~ g k ~- j~ 708-870-8453 .. ~~ 0 Turn Arount'I Time Q Rush t/..J;l <4ay37 3", do...'i<.

0. ~l £

,, E. or Sample ID Date Time Matrix s ~.§ f:J~t c3 :,,;,h W' -* Remarks 0 '~~ ~L< u °"' ~ L0501119TUBO 10/18/2013 10:50 C z,z4r I'){ ~J*... - 1 L.s A -t>~- r, f fl.,;-a.s L0501120TUBO 10/18/2013 10:55 C 5 -x-1 WA - ~, n I ~.'d..S c("

  • c.*.I\\
,I' I* -

1--**** rt:=,;. ,~ ~f,< r* l'i'\\- .. {,Ji t~~i~. 1~!:';'=1"" ~;{-'" t'.),;f ~ P.fi,, -,.\\ Relinquished by: Date/Time ~i~.l /2/.L.,, J Date/Time Total Cooler Temperature: c__..:-- __. lO*[g,(3 < to / 2 AmhiPnt Company Name:Lt) Cl- ~?rn~any N~~: \\i;;\\,r,rp} Cooler ID: Shipper and Number: d Id) I

  • (i -~~*

10)7-01 Received by: Date/rime ~~Jed~/.,; Date/Time 0 ..,\\f:b :{~0 Company Name: Company t:~,.:t C fC;Sc=-t::.. \\0 \\ \\ Relinquished by: Date/Time ~~1~ Date/Time v,-~ ( e) -£8'..-{.J Verified By: Company Name: Co~: ( 7; ;..,-- T .*,t:4

*~~~

Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-4164-1 Login Number: 4164 Question Answer Comment Creator: Clarke, Jill C List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter. True The cooler's custody seal, if present, is intact. N/A Sample custody seals, if present, are intact. True The cooler or samples do not appear to have been compromised or tampered with. True Samples were received on ice. True Cooler Temperature is acceptable. True Cooler Temperature is recorded. True COC is present. True COC is filled out in ink and legible. True COC is filled out with all pertinent information. True Is the Field Sampler's name present on COC? True There are no discrepancies between the containers received and the COC. True Samples are received within Holding Time. True Sample containers have legible labels. True Containers are not broken or leaking. True Sample collection date/times are provided. True Appropriate sample containers are used. True Sample bottles are completely filled. True Sample Preservation Verified. True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is <6mm (1/4"). True Multiphasic samples are not present. True Samples do not require splitting or compositing. N/A Residual Chlorine Checked. TestAmerica St. Louis Page 6 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Definitions/Glossary TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Qualifiers Metals Qualifier Description J Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value. Qualifier Rad Qualifier Description U Indicates the analyte was analyzed for but not detected. Qualifier Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation %R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference) Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin) NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown) PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry) RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin) TEQ Toxicity Equivalent Quotient (Dioxin) TestAmerica St. Louis Page 7 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Method Summary TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Method Method Description Laboratory Protocol SW846 6020A Metals (ICP/MS), Tc-99 TAL SL EPA Moisture Percent Moisture TAL SL SW846 6020A Metals (ICP/MS), Tc-99 in Activity TAL SL Protocol

References:

EPA = US Environmental Protection Agency SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates. Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 8 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Sample Summary TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Lab Sample ID Client Sample ID Received Collected Matrix 160-4164-1 L0501119TUB0 Solid 10/18/13 10:50 10/18/13 18:30 160-4164-2 L0501120TUB0 Solid 10/18/13 10:55 10/18/13 18:30 TestAmerica St. Louis Page 9 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Client Sample Results TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Lab Sample ID: 160-4164-1 Client Sample ID: L0501119TUB0 Matrix: Solid Date Collected: 10/18/13 10:50 Percent Solids: 80.8 Date Received: 10/18/13 18:30 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000070 0.000021 mg/Kg

10/21/13 09:17 10/21/13 20:12 1 Analyte Dil Fac Analyzed Prepared Unit D Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.331 (2+/-) 0.0571 (2+/-) 1 10/21/13 20:12 10/21/13 09:17 pCi/g 0.238 1.39 RL MDC 0.0412 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. Re 30 - 110 Carrier 10/21/13 09:17 10/21/13 20:12 1 Dil Fac Analyzed Prepared Qualifier Limits %Yield 90 Lab Sample ID: 160-4164-2 Client Sample ID: L0501120TUB0 Matrix: Solid Date Collected: 10/18/13 10:55 Percent Solids: 79.1 Date Received: 10/18/13 18:30 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000026 J 0.000068 0.000020 mg/Kg

10/21/13 09:17 10/21/13 20:16 1 Analyte Dil Fac Analyzed Prepared Unit D Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.450 (2+/-) 0.0958 (2+/-) 1 10/21/13 20:16 10/21/13 09:17 pCi/g 0.234 1.37 RL MDC 0.0791 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. Re 30 - 110 Carrier 10/21/13 09:17 10/21/13 20:16 1 Dil Fac Analyzed Prepared Qualifier Limits %Yield 93 TestAmerica St. Louis Page 10 of 14 1 2 3 4 5 6 7 8 9 10 11 12

QC Sample Results TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Method: 6020A - Metals (ICP/MS), Tc-99 Client Sample ID: Method Blank Lab Sample ID: MB 160-79762/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 80367 Prep Batch: 79762 RL MDL Technetium 99 ND 0.000053 0.000016 mg/Kg 10/18/13 14:54 10/21/13 19:06 1 MB MB Analyte Dil Fac Analyzed Prepared D Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79762/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 80367 Prep Batch: 79762 Technetium 99 0.00232 0.00232 mg/Kg 100 80 - 120 Analyte LCS LCS D Unit Result Qualifier %Rec Spike Added %Rec. Limits Client Sample ID: Matrix Spike Lab Sample ID: 160-4137-A-41-D MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 80367 Prep Batch: 79762 Technetium 99 ND 0.00282 0.00278 mg/Kg 99 75 - 125

Analyte MS MS D Unit Result Qualifier %Rec Spike Added Sample Result Sample Qualifier %Rec. Limits Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4137-A-41-E MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 80367 Prep Batch: 79762 Technetium 99 ND 0.00281 0.00281 mg/Kg 100 75 - 125 1 30

Analyte MSD MSD D Unit Result Qualifier %Rec Spike Added Sample Result Sample Qualifier %Rec. Limits Limit RPD RPD Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Client Sample ID: Method Blank Lab Sample ID: MB 160-79762/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 80368 Prep Batch: 79762 Technetium 99 Analyte U 1 10/21/13 19:06 10/18/13 14:54 pCi/g 0.183 MDC 1.07 RL 0.0280 0.0263 (2+/-) (2+/-) MB 0.001826 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert. Count Uncert. Total Carrier Re 30 - 110 10/18/13 14:54 10/21/13 19:06 1 Dil Fac Prepared Analyzed Qualifier Limits %Yield 94 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79762/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 80368 Prep Batch: 79762 Technetium 99 Analyte 120 80 100 39.64 39.7 4.00 1.04 0.179 RL MDC (2+/-) LCS LCS pCi/g Unit Result Qual %Rec Added Spike Limits %Rec. Uncert. Total Re Carrier 30 - 110 LCS Qualifier Limits %Yield 95 LCS TestAmerica St. Louis Page 11 of 14 1 2 3 4 5 6 7 8 9 10 11 12

QC Sample Results TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued) Client Sample ID: Matrix Spike Lab Sample ID: 160-4137-A-41-D MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 80368 Prep Batch: 79762 Technetium 99 Analyte 125 75 99 47.64 48.3 0.0346 U 5.64 1.38 0.236 RL MDC (2+/-) MS MS pCi/g Unit Result Qual %Rec Added Spike Result Sample Sample Qual Limits %Rec. Uncert. Total Re Carrier 30 - 110 MS Qualifier Limits %Yield 88 MS Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4137-A-41-E MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 80368 Prep Batch: 79762 Technetium 99 Analyte 1 0.05 125 75 100 48.16 48.1 0.0346 U 5.68 1.39 0.238 RL MDC (2+/-) MSD MSD pCi/g Unit Result Qual %Rec Limit Added Spike Result Sample Sample Qual Limits %Rec. Uncert. Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits %Yield 86 MSD TestAmerica St. Louis Page 12 of 14 1 2 3 4 5 6 7 8 9 10 11 12

QC Association Summary TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Metals Prep Batch: 79762 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4137-A-41-D MS Matrix Spike Total/NA Solid None 160-4137-A-41-E MSD Matrix Spike Duplicate Total/NA Solid None 160-4164-1 L0501119TUB0 Total/NA Solid None 160-4164-2 L0501120TUB0 Total/NA Solid None LCS 160-79762/2-A Lab Control Sample Total/NA Solid None MB 160-79762/1-A Method Blank Total/NA Analysis Batch: 80367 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 79762 160-4137-A-41-D MS Matrix Spike Total/NA Solid 6020A 79762 160-4137-A-41-E MSD Matrix Spike Duplicate Total/NA Solid 6020A 79762 160-4164-1 L0501119TUB0 Total/NA Solid 6020A 79762 160-4164-2 L0501120TUB0 Total/NA Solid 6020A 79762 LCS 160-79762/2-A Lab Control Sample Total/NA Solid 6020A 79762 MB 160-79762/1-A Method Blank Total/NA General Chemistry Analysis Batch: 79909 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Moisture 160-4164-1 L0501119TUB0 Total/NA Solid Moisture 160-4164-2 L0501120TUB0 Total/NA Solid Moisture 160-4164-2 DU L0501120TUB0 Total/NA Rad Prep Batch: 79762 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4137-A-41-D MS Matrix Spike Total/NA Solid None 160-4137-A-41-E MSD Matrix Spike Duplicate Total/NA Solid None 160-4164-1 L0501119TUB0 Total/NA Solid None 160-4164-2 L0501120TUB0 Total/NA Solid None LCS 160-79762/2-A Lab Control Sample Total/NA Solid None MB 160-79762/1-A Method Blank Total/NA TestAmerica St. Louis Page 13 of 14 1 2 3 4 5 6 7 8 9 10 11 12

Tracer/Carrier Summary TestAmerica Job ID: 160-4164-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT) Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Prep Type: Total/NA Matrix: Solid Lab Sample ID Client Sample ID (30-110) Re 88 160-4137-A-41-D MS Percent Yield (Acceptance Limits) Matrix Spike 86 160-4137-A-41-E MSD Matrix Spike Duplicate 90 160-4164-1 L0501119TUB0 93 160-4164-2 L0501120TUB0 95 LCS 160-79762/2-A Lab Control Sample 94 MB 160-79762/1-A Method Blank Tracer/Carrier Legend Re = Re TestAmerica St. Louis Page 14 of 14 1 2 3 4 5 6 7 8 9 10 11 12}}