ML18019A706
Text
ANALYTICAL REPORT TestAmerica Laboratories, Inc.
TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-3504-2 Client Project/Site: RFP-CBA-022 (21 DAY TAT)
For:
Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by:
9/22/2013 7:47:37 PM Ivan Vania, Project Manager I ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.
Results relate only to the items tested and the sample(s) as received by the laboratory.
1 2
3 4
5 6
7 8
9 10 11
Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
TestAmerica Job ID: 160-3504-2 Page 2 of 14 Cover Page..............................................
1 Table of Contents.........................................
2 Case Narrative...........................................
3 Chain of Custody..........................................
4 Receipt Checklists.........................................
5 Definitions/Glossary.......................................
6 Method Summary.........................................
7 Sample Summary.........................................
8 Client Sample Results......................................
9 QC Sample Results........................................
13 QC Association Summary...................................
14 1
2 3
4 5
6 7
8 9
10 11
Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-3504-2 Project/Site: RFP-CBA-022 (21 DAY TAT)
Job ID: 160-3504-2 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (21 DAY TAT)
Report Number: 160-3504-2 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.
TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.
The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.
Calculations are performed before rounding to avoid round-off errors in calculated results.
All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.
All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %
solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.
This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.
RECEIPT The samples were received on 08/23/2013; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 18.0 C.
RADIUM-226 BY GAMMA SPEC (21 DAY INGROWTH)
Samples L050333PUB00 (160-3504-1), L050334PUB00 (160-3504-2), L050335PUB00 (160-3504-3), L050336PUB00 (160-3504-4),
L050337PUB00 (160-3504-5), L050338PUB00 (160-3504-6), L050339PUB00 (160-3504-7) and L050340PUB00 (160-3504-8) were analyzed for Radium-226 by gamma spec (21 day ingrowth) in accordance with EPA GA_01_R. The samples were leached on 08/26/2013, prepared on 08/28/2013 and analyzed on 09/18/2013.
No other difficulties were encountered during the Radium 226 analysis. All other quality control parameters were within the acceptance limits.
TestAmerica St. Louis Page 3 of 14 1
2 3
4 5
6 7
8 9
10 11
Page 4 of 14 1
2 3
4 5
6 7
8 9
10 11 IProcedure HDP-PR-QA-006, Chain of Custody Page 1 ofl Hematite Decommissioning Project !Revision: 3 I
I Westinghouse Non-Proprietruy Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the con1ainer is transferred to another organization, a person from each organization should sign the Coe. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP.
Chain of Cutody ID No. I F-082313-01 Page 1/1 Project Name:
Westinghouse Electric Company Contact Person:
Gerald Rood Phone Number:
314-810-3382 Sampler Name Scott Jenkins Sample ID L050333PUBOO L050334PUBOO L050335PUBOO L050336PUBOO L050337PUBOO L050338PUBOO L050339PUBOO L050340PUBOO Company Na.me:
Received by:
Company Name:
Relinquished by:
Comoany Name:
Date Time 8/22/2013 11:20 8/22/2013 11:25 8/22/2013 11:33 8/22/2013 11:40 8/22/2013 11:45 8/23/2013 8:20 8/23/2013 8:25 8/23/2013 8:30 Date/Time g-z:;-11 _
/(d)S Date/Time Date/Time Matrix s
s s
s s
s s
s Rece~by:
Comp~y Name:
el Laboratory Name:
TA-MO Laboratory Address:
13715 Rider Trail North
~!----------------------!
-~ PhoneNo.
8 314-298-8566
~ Laboratory Contact Person:
e-Joe Walker Phone No.
708-870-8453 Turn Around Time Rush (7 days)
Remarks LSA 05-03 Bias LSA 05-03 Bias LSA 05-03 Bias LSA 05-03 Bias LSA 05-03 Bias LSA 05-03 Bias LSA 05-03 Bias LSA 05-03 Bias Cooler Temperature:
Cooler ID: jShipper and Number:
21-Date/Time I Comments: Please re-analyze samples after 21-day ingrowth j""Z 'S
!SD period.
Verified By:
<A
~
~
Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-3504-2 Login Number: 3504 Question Answer Comment Creator: Clarke, Jill C List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.
True The cooler's custody seal, if present, is intact.
N/A Sample custody seals, if present, are intact.
True The cooler or samples do not appear to have been compromised or tampered with.
False Samples were received on ice.
True Cooler Temperature is acceptable.
True Cooler Temperature is recorded.
True COC is present.
True COC is filled out in ink and legible.
True COC is filled out with all pertinent information.
True Is the Field Sampler's name present on COC?
True There are no discrepancies between the containers received and the COC.
True Samples are received within Holding Time.
True Sample containers have legible labels.
True Containers are not broken or leaking.
True Sample collection date/times are provided.
True Appropriate sample containers are used.
True Sample bottles are completely filled.
True Sample Preservation Verified.
True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is
<6mm (1/4").
True Multiphasic samples are not present.
True Samples do not require splitting or compositing.
N/A Residual Chlorine Checked.
TestAmerica St. Louis Page 5 of 14 1
2 3
4 5
6 7
8 9
10 11
Definitions/Glossary TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Qualifiers Rad Qualifier Description U
Indicates the analyte was analyzed for but not detected.
Qualifier Glossary These commonly used abbreviations may or may not be present in this report.
Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation
%R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)
Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)
NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown)
PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
TestAmerica St. Louis Page 6 of 14 1
2 3
4 5
6 7
8 9
10 11
Method Summary TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Method Method Description Laboratory Protocol DOE GA-01-R Radium-226 & Other Gamma Emitters (GS)
TAL SL Protocol
References:
DOE = U.S. Department of Energy Laboratory
References:
TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 7 of 14 1
2 3
4 5
6 7
8 9
10 11
Sample Summary TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Lab Sample ID Client Sample ID Received Collected Matrix 160-3504-1 L050333PUB00 Solid 08/22/13 11:20 08/23/13 17:50 160-3504-2 L050334PUB00 Solid 08/22/13 11:25 08/23/13 17:50 160-3504-3 L050335PUB00 Solid 08/22/13 11:33 08/23/13 17:50 160-3504-4 L050336PUB00 Solid 08/22/13 11:40 08/23/13 17:50 160-3504-5 L050337PUB00 Solid 08/22/13 11:45 08/23/13 17:50 160-3504-6 L050338PUB00 Solid 08/23/13 08:20 08/23/13 17:50 160-3504-7 L050339PUB00 Solid 08/23/13 08:25 08/23/13 17:50 160-3504-8 L050340PUB00 Solid 08/23/13 08:30 08/23/13 17:50 TestAmerica St. Louis Page 8 of 14 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Lab Sample ID: 160-3504-1 Client Sample ID: L050333PUB00 Matrix: Solid Date Collected: 08/22/13 11:20 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 0.628 (2+/-)
0.127 (2+/-)
1 09/18/13 17:50 08/28/13 15:38 pCi/g 0.113 RL MDC 0.109 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.377 0.379 0.370 0.784 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.0671 0.142 0.101 0.961 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.0510 0.127 0.0630 0.848 Lead 212 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.0590 0.142 0.0865 1.09 Lead 214 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.207 2.05 1.06 17.2 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.659 0.276 0.271 U
0.480 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.0671 1.00 0.142 0.101 0.961 Radium 226 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.113 0.127 0.109 0.628 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 17:50 1
1.06 1.11 0.961 5.39 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.223 0.234 0.201 1.18 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 17:50 1
0.119 0.0717 0.0716 U
-0.0422 Americium 241 pCi/g 08/28/13 15:38 09/18/13 17:50 1
3.09 3.69 3.52 10.8 Protactinium 234m Lab Sample ID: 160-3504-2 Client Sample ID: L050334PUB00 Matrix: Solid Date Collected: 08/22/13 11:25 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.24 (2+/-)
0.219 (2+/-)
1 09/18/13 18:46 08/28/13 15:38 pCi/g 0.211 RL MDC 0.179 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.460 0.509 0.491 1.32 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.0876 0.183 0.139 1.14 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.0818 0.165 0.0903 1.06 Lead 212 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.110 0.204 0.145 1.38 Lead 214 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.210 2.76 1.58 22.1 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:46 1
1.58 0.263 0.259 U
0.401 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.0876 1.00 0.183 0.139 1.14 Radium 226 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.211 0.219 0.179 1.24 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 18:46 1
1.92 3.10 1.89 23.5 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.421 0.603 0.378 4.61 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:46 1
0.165 0.102 0.101 U
0.110 Americium 241 pCi/g 08/28/13 15:38 09/18/13 18:46 1
5.73 8.87 8.19 33.7 Protactinium 234m Lab Sample ID: 160-3504-3 Client Sample ID: L050335PUB00 Matrix: Solid Date Collected: 08/22/13 11:33 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.21 (2+/-)
0.207 (2+/-)
1 09/18/13 18:44 08/28/13 15:38 pCi/g 0.0827 RL MDC 0.167 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.450 0.507 0.489 1.29 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0745 0.167 0.116 1.16 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0606 0.164 0.0768 1.12 Lead 212 TestAmerica St. Louis Page 9 of 14 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Lab Sample ID: 160-3504-3 Client Sample ID: L050335PUB00 Matrix: Solid Date Collected: 08/22/13 11:33 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)
Analyte Lead 214 1.42 (2+/-)
0.181 (2+/-)
1 09/18/13 18:44 08/28/13 15:38 pCi/g 0.0759 RL MDC 0.106 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.402 2.64 1.31 22.4 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:44 1
1.26 0.246 0.244 U
0.347 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0745 1.00 0.167 0.116 1.16 Radium 226 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0827 0.207 0.167 1.21 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 18:44 1
1.11 1.25 1.02 6.90 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.274 0.277 0.236 1.42 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.137 0.0824 0.0823 U
0.0362 Americium 241 pCi/g 08/28/13 15:38 09/18/13 18:44 1
6.26 4.19 4.12 7.40 Protactinium 234m Lab Sample ID: 160-3504-4 Client Sample ID: L050336PUB00 Matrix: Solid Date Collected: 08/22/13 11:40 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.08 (2+/-)
0.197 (2+/-)
1 09/18/13 18:43 08/28/13 15:38 pCi/g 0.131 RL MDC 0.164 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.386 0.414 0.396 1.18 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0729 0.163 0.111 1.15 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0871 0.154 0.0816 1.01 Lead 212 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0845 0.172 0.113 1.25 Lead 214 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.400 2.46 1.24 20.8 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:43 1
1.25 0.759 0.757 U
-0.587 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0729 1.00 0.163 0.111 1.15 Radium 226 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.131 0.197 0.164 1.08 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 18:43 1
1.06 1.07 0.952 4.70 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.264 0.171 0.170 U
0.197 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.125 0.0751 0.0751 U
0.0318 Americium 241 pCi/g 08/28/13 15:38 09/18/13 18:43 1
5.08 3.46 3.39 6.72 Protactinium 234m Lab Sample ID: 160-3504-5 Client Sample ID: L050337PUB00 Matrix: Solid Date Collected: 08/22/13 11:45 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.08 (2+/-)
0.180 (2+/-)
1 09/18/13 18:44 08/28/13 15:38 pCi/g 0.123 RL MDC 0.143 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.566 0.577 0.563 1.22 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0978 0.178 0.136 1.11 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0681 0.183 0.0870 1.24 Lead 212 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0823 0.171 0.102 1.33 Lead 214 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.294 2.47 1.37 20.0 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:44 1
1.28 0.297 0.291 U
0.508 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.0978 1.00 0.178 0.136 1.11 Radium 226 TestAmerica St. Louis Page 10 of 14 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Lab Sample ID: 160-3504-5 Client Sample ID: L050337PUB00 Matrix: Solid Date Collected: 08/22/13 11:45 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)
Analyte Thorium 232 1.08 (2+/-)
0.180 (2+/-)
1 09/18/13 18:44 08/28/13 15:38 pCi/g 0.123 RL MDC 0.143 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:44 1
1.04 0.946 0.871 3.53 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.217 0.161 0.159 U
0.214 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:44 1
0.104 0.0612 0.0612 U
0.00629 Americium 241 pCi/g 08/28/13 15:38 09/18/13 18:44 1
7.23 4.13 4.12 U
3.50 Protactinium 234m Lab Sample ID: 160-3504-6 Client Sample ID: L050338PUB00 Matrix: Solid Date Collected: 08/23/13 08:20 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.16 (2+/-)
0.203 (2+/-)
1 09/18/13 18:45 08/28/13 15:38 pCi/g 0.117 RL MDC 0.165 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.396 0.469 0.447 1.37 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.105 0.189 0.135 1.27 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.0829 0.169 0.0922 1.10 Lead 212 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.0937 0.194 0.127 1.41 Lead 214 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.339 2.62 1.53 20.8 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:45 1
1.70 1.03 1.03 U
-0.764 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.105 1.00 0.189 0.135 1.27 Radium 226 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.117 0.203 0.165 1.16 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 18:45 1
1.39 1.68 1.31 10.1 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.336 0.370 0.325 1.73 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:45 1
0.175 0.105 0.105 U
-0.0228 Americium 241 pCi/g 08/28/13 15:38 09/18/13 18:45 1
4.08 5.62 5.29 18.5 Protactinium 234m Lab Sample ID: 160-3504-7 Client Sample ID: L050339PUB00 Matrix: Solid Date Collected: 08/23/13 08:25 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.21 (2+/-)
0.184 (2+/-)
1 09/18/13 18:43 08/28/13 15:38 pCi/g 0.155 RL MDC 0.142 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.554 0.624 0.606 1.50 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0889 0.174 0.128 1.20 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0741 0.162 0.0881 1.27 Lead 212 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0966 0.178 0.110 1.44 Lead 214 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.444 2.59 1.41 22.6 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:43 1
1.31 0.486 0.478 U
0.868 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0889 1.00 0.174 0.128 1.20 Radium 226 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.155 0.184 0.142 1.21 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 18:43 1
1.31 1.64 1.24 11.0 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.367 0.409 0.325 2.57 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.162 1.65 1.65 U
-0.0289 Americium 241 TestAmerica St. Louis Page 11 of 14 1
2 3
4 5
6 7
8 9
10 11
Client Sample Results TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Lab Sample ID: 160-3504-7 Client Sample ID: L050339PUB00 Matrix: Solid Date Collected: 08/23/13 08:25 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)
Analyte Protactinium 234m 21.5 (2+/-)
6.98 (2+/-)
1 09/18/13 18:43 08/28/13 15:38 pCi/g 5.03 RL MDC 6.67 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
Lab Sample ID: 160-3504-8 Client Sample ID: L050340PUB00 Matrix: Solid Date Collected: 08/23/13 08:30 Date Received: 08/23/13 17:50 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Analyte Actinium 228 1.08 (2+/-)
0.175 (2+/-)
1 09/18/13 18:43 08/28/13 15:38 pCi/g 0.117 RL MDC 0.135 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.
Uncert.
pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.511 0.582 0.562 1.44 Bismuth 212 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0793 0.181 0.125 1.27 Bismuth 214 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0713 0.170 0.0821 1.15 Lead 212 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0795 0.179 0.105 1.40 Lead 214 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.473 2.66 1.37 22.3 Potassium 40 pCi/g 08/28/13 15:38 09/18/13 18:43 1
1.34 0.286 0.281 U
0.465 Protactinium 231 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.0793 1.00 0.181 0.125 1.27 Radium 226 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.117 0.175 0.135 1.08 Thorium 232 pCi/g 08/28/13 15:38 09/18/13 18:43 1
1.22 1.77 1.17 12.7 Thorium 234 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.332 0.366 0.265 2.48 Uranium 235 pCi/g 08/28/13 15:38 09/18/13 18:43 1
0.152 0.0911 0.0911 U
-0.0156 Americium 241 pCi/g 08/28/13 15:38 09/18/13 18:43 1
5.80 4.76 4.62 11.6 Protactinium 234m TestAmerica St. Louis Page 12 of 14 1
2 3
4 5
6 7
8 9
10 11
QC Sample Results TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)
Client Sample ID: Method Blank Lab Sample ID: MB 160-69157/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 73103 Prep Batch: 69157 Actinium 228 Analyte U
1 09/18/13 20:43 08/28/13 15:38 pCi/g 0.0422 MDC RL 0.0264 0.0264 (2+/-)
(2+/-)
MB 0.01526 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.
Count Uncert.
Total 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.276 0.0703 0.0703 U
0.0000 Bismuth 212 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0387 0.0209 0.0209 U
0.006060 Bismuth 214 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0291 0.0344 0.0344 U
-0.003530 Lead 212 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0360 8.71 8.71 U
-0.007280 Lead 214 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.307 0.168 0.168 U
0.07050 Potassium 40 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.402 0.209 0.209 U
0.001341 Protactinium 231 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0387 1.00 0.0209 0.0209 U
0.006060 Radium 226 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0422 0.0264 0.0264 U
0.01526 Thorium 232 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.286 0.261 0.261 U
-0.07160 Thorium 234 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0690 0.0376 0.0376 U
-0.005515 Uranium 235 1
09/18/13 20:43 08/28/13 15:38 pCi/g 0.0223 0.0122 0.0122 U
0.002366 Americium 241 1
09/18/13 20:43 08/28/13 15:38 pCi/g 5.04 1.04 1.04 U
0.0000 Protactinium 234m Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-69157/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 73116 Prep Batch: 69157 Americium 241 Analyte 116 87 90 87.98 97.7 9.16 0.563 RL MDC (2+/-)
LCS LCS pCi/g Unit Result Qual
%Rec Added Spike Limits
%Rec.
Uncert.
Total Cesium 137 31.6 29.82 3.13 0.161 pCi/g 94 87 - 120 Cobalt 60 24.6 23.17 2.35 0.104 pCi/g 94 87 - 115 Client Sample ID: L050333PUB00 Lab Sample ID: 160-3504-1 DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 73103 Prep Batch: 69157 Actinium 228 Analyte 1
0.72 0.8294 0.628 0.152 0.113 RL MDC (2+/-)
DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.
Total RER RER Bismuth 212 0.784 0.9735 0.402 0.501 pCi/g 0.24 1
Bismuth 214 0.961 0.9842 0.151 0.0472 pCi/g 0.08 1
Lead 212 0.848 0.7594 0.124 0.0711 pCi/g 0.35 1
Lead 214 1.09 1.026 0.159 0.0853 pCi/g 0.21 1
Potassium 40 17.2 17.25 2.26 0.387 pCi/g 0.01 1
Protactinium 231 0.480 U
0.4221 U
0.280 1.43 pCi/g 0.10 1
Radium 226 0.961 0.9842 0.151 1.00 0.0472 pCi/g 0.08 1
Thorium 232 0.628 0.8294 0.152 0.113 pCi/g 0.72 1
Thorium 234 5.39 6.371 1.17 1.07 pCi/g 0.43 1
Uranium 235 1.18 1.087 0.247 0.261 pCi/g 0.18 1
-0.0422 U
-0.01350 U
0.0801 0.135 pCi/g 0.19 1
Protactinium 234m 10.8 7.599 5.01 7.13 pCi/g 0.36 1
TestAmerica St. Louis Page 13 of 14 1
2 3
4 5
6 7
8 9
10 11
QC Association Summary TestAmerica Job ID: 160-3504-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)
Rad Leach Batch: 68464 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-3504-1 L050333PUB00 Total/NA Solid Dry and Grind 160-3504-1 DU L050333PUB00 Total/NA Solid Dry and Grind 160-3504-2 L050334PUB00 Total/NA Solid Dry and Grind 160-3504-3 L050335PUB00 Total/NA Solid Dry and Grind 160-3504-4 L050336PUB00 Total/NA Solid Dry and Grind 160-3504-5 L050337PUB00 Total/NA Solid Dry and Grind 160-3504-6 L050338PUB00 Total/NA Solid Dry and Grind 160-3504-7 L050339PUB00 Total/NA Solid Dry and Grind 160-3504-8 L050340PUB00 Total/NA Prep Batch: 69157 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-21 68464 160-3504-1 L050333PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-1 DU L050333PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-2 L050334PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-3 L050335PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-4 L050336PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-5 L050337PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-6 L050338PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-7 L050339PUB00 Total/NA Solid Fill_Geo-21 68464 160-3504-8 L050340PUB00 Total/NA Solid Fill_Geo-21 LCS 160-69157/2-A Lab Control Sample Total/NA Solid Fill_Geo-21 MB 160-69157/1-A Method Blank Total/NA TestAmerica St. Louis Page 14 of 14 1
2 3
4 5
6 7
8 9
10 11