Westinghouse Hematite Decommissioning Project - Final Status Survey Final Report Volume 3, Chapter 16, Survey Area Release Record for Land Survey Area 05, Survey Units 01, 02, 03 and 04, Revision 1, J1974-1 Uds Level 2 Report Final Report
ML18019A669
Person / Time
Site: 07000036
Issue date: 04/30/2013
From: Vania I
TestAmerica Labs - St. Louis, Westinghouse
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18019A532 List: ... further results
References
HEM-18-2
Download: ML18019A669 (19)


Text

ANALYTICAL REPORT TestAmerica Laboratories, Inc.

TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-1974-1 Client Project/Site: RFP-CBA-022 (21 DAY TAT)

For:

Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by:

4/30/2013 3:49:24 PM Ivan Vania Project Manager I ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.

Results relate only to the items tested and the sample(s) as received by the laboratory.

1 2

3 4

5 6

7 8

9 10 11 12

Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

TestAmerica Job ID: 160-1974-1 Page 2 of 19 Cover Page..............................................

1 Table of Contents.........................................

2 Case Narrative...........................................

3 Chain of Custody..........................................

5 Receipt Checklists.........................................

6 Definitions/Glossary.......................................

7 Method Summary.........................................

8 Sample Summary.........................................

9 Client Sample Results......................................

10 QC Sample Results........................................

14 QC Association Summary...................................

17 Tracer Carrier Summary....................................

19 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-1974-1 Project/Site: RFP-CBA-022 (21 DAY TAT)

Job ID: 160-1974-1 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (21 DAY TAT)

Report Number: 160-1974-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.

TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.

The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.

Calculations are performed before rounding to avoid round-off errors in calculated results.

All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.

All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %

solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.

This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.

RECEIPT The samples were received on 04/03/2013; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 19.0°C.

TECHNETIUM-99 (ICPMS)

Samples L050103TUB00 (160-1974-1), L050104TUB00 (160-1974-2), L050176TUB00 (160-1974-3), L050177TUB00 (160-1974-4),

L050186TUB00 (160-1974-5) and L050187TUB00 (160-1974-6) were analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A. The samples were prepared on 04/24/2013 and analyzed on 04/25/2013.

No difficulties were encountered during the Tc-99 analyses. All quality control parameters were within the acceptance limits.

PERCENT SOLIDS Samples L050103TUB00 (160-1974-1), L050104TUB00 (160-1974-2), L050176TUB00 (160-1974-3), L050177TUB00 (160-1974-4),

L050186TUB00 (160-1974-5) and L050187TUB00 (160-1974-6) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 04/04/2013.

TestAmerica St. Louis Page 3 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-1974-1 Project/Site: RFP-CBA-022 (21 DAY TAT)

Job ID: 160-1974-1 (Continued)

Laboratory: TestAmerica St. Louis (Continued)

No difficulties were encountered during the % solids analyses. All quality control parameters were within the acceptance limits.

RADIUM-226 BY GAMMA SPEC (21 DAY INGROWTH)

Samples L050103TUB00 (160-1974-1), L050104TUB00 (160-1974-2), L050176TUB00 (160-1974-3), L050177TUB00 (160-1974-4),

L050186TUB00 (160-1974-5) and L050187TUB00 (160-1974-6) were analyzed for Radium-226 by gamma spec (21 day ingrowth) in accordance with EPA GA_01_R. The samples were leached on 04/04/2013, prepared on 04/08/2013 and analyzed on 04/29/2013.

Americium 241, Cobalt 60 and Protactinium 234m exceeded the rpd limit for the duplicate of sample 160-1973-1; however, the RER was within QC limits.

Refer to the QC report for details. No other difficulties were encountered during the Radium 226 analyses. All other quality control parameters were within the acceptance limits.

TestAmerica St. Louis Page 4 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Page 5 of 19 1

2 3

4 5

6 7

8 9

10 11 12 Procedure HDP-PR-QA-006, Chain of Custody Hematite Decommissioning Project Revision: 3 I

Page I of!

Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP.

Chain of Cutody ID No.

F-040313-01 Page 1/1 Requested Analysis Laboratory Name:

Project Name:

1*..*

TA-MO

[.- - -,-;*

Westinghouse Electric Company

. '° N

. N Contact Person:

di

  • . " ~-****

Laboratory Address:

Gerald Rood

~

13715 Rider Trail North

<2

~

Phone Number:

g Phone No.

0 Is 8

314-810-3382 00 314-298-8566

.s Sampler Name

.; Laboratory Contact Person:

c;j

  • ,' 0 Josh Bushman

§:.

-0 b

Joe Walker a

~

Phone No.

e 0.

  • a

{)

0 Q)

Q) 708-870-8453 5

.* i:,.

. ;:i i:,.

r:n r:n Turn Around Time s

. *.o:s

{)

c;j...

a

  • 5. *'°'

~

Normal (21 days)

0. a

.8 C'\\

~

Sample ID Date Time Matrix

:,ro 0

.*Q "'

Remarks O * ~ E-<

0 L050I03TUBOO 3/26/2013 11:45 s

G X

X 1

L050I04TUBOO 3/26/2013 11:50 s

G X

X 1

L050176TUBOO 3/26/2013 11:45 s

G X,

X 1

L050177TUBOO 3/26/2013 11:40 s G x X

1 L050186TUBOO 3/26/2013 11:30 s G

  • )f'. '

X 1

L050187TUBOO 3/26/2013 11:35 s G

X X

1 I,

Relinquisted b~

'-\\J ~~~ime /

l~ivedl ~ J

,t

!/Jate/Time Total Cooler Temperature:

J.

13 6

Ambient Company Name~~(_

Company Jame:

Cooler ID: Shipper and Number:

,~*.rs

'ii 14-~'75 0326-04 Received by:

Date/Time Relinquished by:

Date/Time 0

Company Name:

Company Name:

Relinquished by:

Date/Time Received by:

Date/Time Verified By:

Company Name:

Company Name:

r

  • --.c:,

-...i

-+--

Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-1974-1 Login Number: 1974 Question Answer Comment Creator: Clarke, Jill List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.

True The cooler's custody seal, if present, is intact.

True Sample custody seals, if present, are intact.

True The cooler or samples do not appear to have been compromised or tampered with.

False Samples were received on ice.

True Cooler Temperature is acceptable.

True Cooler Temperature is recorded.

True COC is present.

True COC is filled out in ink and legible.

True COC is filled out with all pertinent information.

True Is the Field Sampler's name present on COC?

True There are no discrepancies between the containers received and the COC.

True Samples are received within Holding Time.

True Sample containers have legible labels.

True Containers are not broken or leaking.

True Sample collection date/times are provided.

True Appropriate sample containers are used.

True Sample bottles are completely filled.

True Sample Preservation Verified.

True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is

<6mm (1/4").

True Multiphasic samples are not present.

True Samples do not require splitting or compositing.

N/A Residual Chlorine Checked.

TestAmerica St. Louis Page 6 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Definitions/Glossary TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Qualifiers Metals Qualifier Description J

Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value.

Qualifier Rad Qualifier Description F

Duplicate RPD exceeds the control limit Qualifier U

Indicates the analyte was analyzed for but not detected.

Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation

%R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)

DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)

ND Not detected at the reporting limit (or MDL or EDL if shown)

PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)

RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)

TEQ Toxicity Equivalent Quotient (Dioxin)

TestAmerica St. Louis Page 7 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Method Summary TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Method Method Description Laboratory Protocol SW846 6020A Metals (ICP/MS), Tc-99 TAL SL EPA Moisture Percent Moisture TAL SL SW846 6020A Metals (ICP/MS), Tc-99 in Activity TAL SL DOE GA-01-R Radium-226 & Other Gamma Emitters (GS)

TAL SL Protocol

References:

DOE = U.S. Department of Energy EPA = US Environmental Protection Agency SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.

Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 8 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Sample Summary TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Lab Sample ID Client Sample ID Received Collected Matrix 160-1974-1 L050103TUB00 Solid 03/26/13 11:45 04/03/13 14:55 160-1974-2 L050104TUB00 Solid 03/26/13 11:50 04/03/13 14:55 160-1974-3 L050176TUB00 Solid 03/26/13 11:45 04/03/13 14:55 160-1974-4 L050177TUB00 Solid 03/26/13 11:40 04/03/13 14:55 160-1974-5 L050186TUB00 Solid 03/26/13 11:30 04/03/13 14:55 160-1974-6 L050187TUB00 Solid 03/26/13 11:35 04/03/13 14:55 TestAmerica St. Louis Page 9 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Lab Sample ID: 160-1974-1 Client Sample ID: L050103TUB00 Matrix: Solid Date Collected: 03/26/13 11:45 Percent Solids: 78.7 Date Received: 04/03/13 14:55 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.00016 J

0.00070 0.000021 mg/Kg

04/24/13 09:40 04/25/13 16:52 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 2.76 (2+/-)

0.363 (2+/-)

1 04/25/13 16:52 04/24/13 09:40 pCi/g 0.241 1.41 RL MDC 0.206 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 04/24/13 09:40 04/25/13 16:52 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Analyte Actinium 228 0.604 (2+/-)

0.0989 (2+/-)

1 04/29/13 18:49 04/08/13 10:44 pCi/g 0.0527 RL MDC 0.0774 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.197 0.284 0.267 0.925 Bismuth 212 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.0577 0.101 0.0790 0.609 Bismuth 214 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.0507 0.0889 0.0526 0.554 Lead 212 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.0584 0.108 0.0790 0.712 Lead 214 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.322 1.44 0.860 11.3 Potassium 40 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.804 0.194 0.191 U

0.295 Protactinium 231 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.0577 1.00 0.101 0.0790 0.609 Radium 226 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.0527 0.0989 0.0774 0.604 Thorium 232 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.664 0.511 0.504 0.801 Thorium 234 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.191 0.135 0.135 U

0.0564 Uranium 235 pCi/g 04/08/13 10:44 04/29/13 18:49 1

0.0842 0.0499 0.0499 U

-0.00680 Americium 241 pCi/g 04/08/13 10:44 04/29/13 18:49 1

3.44 11.6 11.6 U

-0.429 Protactinium 234m Lab Sample ID: 160-1974-2 Client Sample ID: L050104TUB00 Matrix: Solid Date Collected: 03/26/13 11:50 Percent Solids: 76.7 Date Received: 04/03/13 14:55 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.00012 J

0.00072 0.000022 mg/Kg

04/24/13 10:41 04/25/13 17:29 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 2.08 (2+/-)

0.331 (2+/-)

1 04/25/13 17:29 04/24/13 10:41 pCi/g 0.246 1.44 RL MDC 0.230 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 04/24/13 10:41 04/25/13 17:29 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.28 (2+/-)

0.215 (2+/-)

1 04/29/13 13:16 04/08/13 10:44 pCi/g 0.104 RL MDC 0.176 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

TestAmerica St. Louis Page 10 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Lab Sample ID: 160-1974-2 Client Sample ID: L050104TUB00 Matrix: Solid Date Collected: 03/26/13 11:50 Date Received: 04/03/13 14:55 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)

Analyte Bismuth 212 1.47 (2+/-)

0.591 (2+/-)

1 04/29/13 13:16 04/08/13 10:44 pCi/g 0.510 RL MDC 0.573 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.0897 0.191 0.139 1.34 Bismuth 214 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.0768 0.167 0.0900 1.31 Lead 212 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.0684 0.198 0.124 1.59 Lead 214 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.554 2.47 1.40 21.1 Potassium 40 pCi/g 04/08/13 10:44 04/29/13 13:16 1

1.41 0.357 0.348 U

0.807 Protactinium 231 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.0897 1.00 0.191 0.139 1.34 Radium 226 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.104 0.215 0.176 1.28 Thorium 232 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.967 0.813 0.790 1.95 Thorium 234 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.241 0.153 0.151 U

0.225 Uranium 235 pCi/g 04/08/13 10:44 04/29/13 13:16 1

0.120 0.808 0.808 U

-0.107 Americium 241 pCi/g 04/08/13 10:44 04/29/13 13:16 1

6.33 3.63 3.63 U

0.951 Protactinium 234m Lab Sample ID: 160-1974-3 Client Sample ID: L050176TUB00 Matrix: Solid Date Collected: 03/26/13 11:45 Percent Solids: 75.4 Date Received: 04/03/13 14:55 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000033 J

0.00072 0.000022 mg/Kg

04/24/13 11:01 04/25/13 17:36 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.568 (2+/-)

0.177 (2+/-)

1 04/25/13 17:36 04/24/13 11:01 pCi/g 0.245 1.43 RL MDC 0.155 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 04/24/13 11:01 04/25/13 17:36 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 93 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.16 (2+/-)

0.180 (2+/-)

1 04/29/13 18:50 04/08/13 10:44 pCi/g 0.0863 RL MDC 0.136 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.426 0.485 0.460 1.49 Bismuth 212 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.0769 0.174 0.122 1.19 Bismuth 214 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.0578 0.169 0.0789 1.16 Lead 212 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.0806 0.159 0.0953 1.22 Lead 214 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.432 2.23 1.28 17.8 Potassium 40 pCi/g 04/08/13 10:44 04/29/13 18:50 1

1.14 0.241 0.232 U

0.601 Protactinium 231 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.0769 1.00 0.174 0.122 1.19 Radium 226 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.0863 0.180 0.136 1.16 Thorium 232 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.817 0.619 0.604 1.28 Thorium 234 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.248 0.147 0.146 U

0.127 Uranium 235 pCi/g 04/08/13 10:44 04/29/13 18:50 1

0.104 0.119 0.119 U

-0.0310 Americium 241 pCi/g 04/08/13 10:44 04/29/13 18:50 1

5.79 3.26 3.26 U

-0.514 Protactinium 234m TestAmerica St. Louis Page 11 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Lab Sample ID: 160-1974-4 Client Sample ID: L050177TUB00 Matrix: Solid Date Collected: 03/26/13 11:40 Percent Solids: 77.8 Date Received: 04/03/13 14:55 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000088 J

0.00073 0.000022 mg/Kg

04/24/13 11:22 04/25/13 17:44 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 1.51 (2+/-)

0.196 (2+/-)

1 04/25/13 17:44 04/24/13 11:22 pCi/g 0.251 1.46 RL MDC 0.100 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 04/24/13 11:22 04/25/13 17:44 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 87 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.16 (2+/-)

0.219 (2+/-)

1 04/29/13 19:04 04/08/13 10:44 pCi/g 0.170 RL MDC 0.188 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.807 0.518 0.514 U

0.634 Bismuth 212 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.103 0.199 0.158 1.24 Bismuth 214 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.160 0.189 0.164 0.874 Lead 212 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.127 0.203 0.165 1.23 Lead 214 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.594 2.53 1.67 19.7 Potassium 40 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.922 0.600 0.595 U

0.773 Protactinium 231 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.103 1.00 0.199 0.158 1.24 Radium 226 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.170 0.219 0.188 1.16 Thorium 232 pCi/g 04/08/13 10:44 04/29/13 19:04 1

1.34 0.506 0.504 U

0.510 Thorium 234 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.331 0.213 0.212 U

0.121 Uranium 235 pCi/g 04/08/13 10:44 04/29/13 19:04 1

0.134 0.0799 0.0799 U

0.0220 Americium 241 pCi/g 04/08/13 10:44 04/29/13 19:04 1

8.28 4.62 4.62 U

0.629 Protactinium 234m Lab Sample ID: 160-1974-5 Client Sample ID: L050186TUB00 Matrix: Solid Date Collected: 03/26/13 11:30 Percent Solids: 80.1 Date Received: 04/03/13 14:55 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000063 J

0.00069 0.000021 mg/Kg

04/24/13 11:42 04/25/13 17:51 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 1.08 (2+/-)

0.164 (2+/-)

1 04/25/13 17:51 04/24/13 11:42 pCi/g 0.236 1.38 RL MDC 0.109 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 04/24/13 11:42 04/25/13 17:51 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Analyte Actinium 228 0.677 (2+/-)

0.116 (2+/-)

1 04/29/13 20:12 04/08/13 10:44 pCi/g 0.0958 RL MDC 0.0928 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

TestAmerica St. Louis Page 12 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Lab Sample ID: 160-1974-5 Client Sample ID: L050186TUB00 Matrix: Solid Date Collected: 03/26/13 11:30 Date Received: 04/03/13 14:55 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)

Analyte Bismuth 212 0.747 (2+/-)

0.286 (2+/-)

1 04/29/13 20:12 04/08/13 10:44 pCi/g 0.251 RL MDC 0.275 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.0550 0.120 0.0865 0.798 Bismuth 214 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.0557 0.110 0.0608 0.706 Lead 212 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.0627 0.118 0.0784 0.846 Lead 214 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.209 1.55 0.900 12.4 Potassium 40 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.759 0.287 0.285 U

0.308 Protactinium 231 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.0550 1.00 0.120 0.0865 0.798 Radium 226 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.0958 0.116 0.0928 0.677 Thorium 232 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.788 0.306 0.295 U

0.778 Thorium 234 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.204 0.119 0.119 U

0.121 Uranium 235 pCi/g 04/08/13 10:44 04/29/13 20:12 1

0.0836 0.0494 0.0494 U

-0.00388 Americium 241 pCi/g 04/08/13 10:44 04/29/13 20:12 1

5.31 1.48 1.47 U

1.86 Protactinium 234m Lab Sample ID: 160-1974-6 Client Sample ID: L050187TUB00 Matrix: Solid Date Collected: 03/26/13 11:35 Percent Solids: 78.2 Date Received: 04/03/13 14:55 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000092 J

0.00072 0.000021 mg/Kg

04/24/13 12:02 04/25/13 17:59 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 1.57 (2+/-)

0.193 (2+/-)

1 04/25/13 17:59 04/24/13 12:02 pCi/g 0.245 1.43 RL MDC 0.0929 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 04/24/13 12:02 04/25/13 17:59 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 89 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Analyte Actinium 228 0.805 (2+/-)

0.130 (2+/-)

1 04/29/13 20:11 04/08/13 10:44 pCi/g 0.101 RL MDC 0.101 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.479 0.336 0.328 0.671 Bismuth 212 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.0699 0.118 0.0852 0.780 Bismuth 214 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.0541 0.125 0.0648 0.828 Lead 212 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.0632 0.145 0.0916 1.08 Lead 214 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.355 1.70 0.983 13.6 Potassium 40 pCi/g 04/08/13 10:44 04/29/13 20:11 1

1.01 0.179 0.178 U

0.217 Protactinium 231 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.0699 1.00 0.118 0.0852 0.780 Radium 226 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.101 0.130 0.101 0.805 Thorium 232 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.799 0.663 0.647 1.38 Thorium 234 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.173 0.132 0.130 0.227 Uranium 235 pCi/g 04/08/13 10:44 04/29/13 20:11 1

0.0997 0.0590 0.0590 U

0.00332 Americium 241 pCi/g 04/08/13 10:44 04/29/13 20:11 1

4.58 2.61 2.61 U

1.04 Protactinium 234m TestAmerica St. Louis Page 13 of 19 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 Client Sample ID: Method Blank Lab Sample ID: MB 160-46432/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 47954 Prep Batch: 46432 RL MDL Technetium 99 ND 0.00051 0.000015 mg/Kg 04/24/13 09:00 04/25/13 16:37 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-46432/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 47954 Prep Batch: 46432 Technetium 99 0.0123 0.0120 mg/Kg 97 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: L050103TUB00 Lab Sample ID: 160-1974-1 MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 47954 Prep Batch: 46432 Technetium 99 0.00016 J

0.0163 0.0151 mg/Kg 92 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: L050103TUB00 Lab Sample ID: 160-1974-1 MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 47954 Prep Batch: 46432 Technetium 99 0.00016 J

0.0166 0.0152 mg/Kg 90 75 - 125 1

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Client Sample ID: Method Blank Lab Sample ID: MB 160-46432/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 47955 Prep Batch: 46432 Technetium 99 Analyte U

1 04/25/13 16:37 04/24/13 09:00 pCi/g 0.176 MDC 1.03 RL 0.0311 0.0300 (2+/-)

(2+/-)

MB 0.05072 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Carrier Re 30 - 110 04/24/13 09:00 04/25/13 16:37 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 98 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-46432/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 47955 Prep Batch: 46432 Technetium 99 Analyte 120 80 97 204.9 211 20.0 1.03 0.176 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 97 LCS TestAmerica St. Louis Page 14 of 19 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued)

Client Sample ID: L050103TUB00 Lab Sample ID: 160-1974-1 MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 47955 Prep Batch: 46432 Technetium 99 Analyte 125 75 92 258.6 279 2.76 26.6 1.36 0.233 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 93 MS Client Sample ID: L050103TUB00 Lab Sample ID: 160-1974-1 MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 47955 Prep Batch: 46432 Technetium 99 Analyte 30 1

125 75 90 260.1 285 2.76 27.9 1.39 0.237 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RPD RPD Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 92 MSD Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS)

Client Sample ID: Method Blank Lab Sample ID: MB 160-44755/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 48156 Prep Batch: 44755 Actinium 228 Analyte U

1 04/29/13 20:09 04/08/13 10:44 pCi/g 0.0919 MDC RL 0.0486 0.0485 (2+/-)

(2+/-)

MB 0.008513 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.282 0.153 0.153 U

0.04528 Bismuth 212 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0392 0.0206 0.0206 U

0.003745 Bismuth 214 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0227 0.0377 0.0377 U

-0.005785 Lead 212 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0342 0.0190 0.0190 U

0.005287 Lead 214 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.251 0.153 0.153 U

0.1108 Potassium 40 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.489 0.135 0.135 U

0.0000 Protactinium 231 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0392 1.00 0.0206 0.0206 U

0.003745 Radium 226 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0919 0.0486 0.0485 U

0.008513 Thorium 232 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.297 0.216 0.216 U

-0.04186 Thorium 234 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0654 0.0366 0.0365 U

0.02972 Uranium 235 1

04/29/13 20:09 04/08/13 10:44 pCi/g 0.0219 0.0125 0.0125 U

0.005776 Americium 241 1

04/29/13 20:09 04/08/13 10:44 pCi/g 3.73 0.424 0.424 U

0.0000 Protactinium 234m Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-44755/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 48157 Prep Batch: 44755 Americium 241 Analyte 116 87 100 97.85 97.8 10.2 0.955 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Cesium 137 31.9 31.49 3.31 0.194 pCi/g 99 87 - 120 TestAmerica St. Louis Page 15 of 19 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued)

Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-44755/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 48157 Prep Batch: 44755 Cobalt 60 Analyte 115 87 97 25.22 25.9 2.55 0.108 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Client Sample ID: Duplicate Lab Sample ID: 160-1973-A-1-D DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 48161 Prep Batch: 44755 Actinium 228 Analyte 40 4

0.8787 0.911 0.139 0.124 RL MDC (2+/-)

DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.

Total RPD RPD Bismuth 212 1.27 0.8676 0.317 0.402 pCi/g 38 40 Bismuth 214 1.17 1.053 0.149 0.0625 pCi/g 10 40 Lead 212 1.08 0.9931 0.146 0.0605 pCi/g 8

40 Lead 214 1.34 1.135 0.143 0.0758 pCi/g 16 40 Potassium 40 18.5 17.42 2.09 0.366 pCi/g 6

40 Protactinium 231 0.573 U

0.4713 U

0.324 1.04 pCi/g 20 40 Radium 226 1.17 1.053 0.149 1.00 0.0625 pCi/g 10 40 Thorium 232 0.911 0.8787 0.139 0.124 pCi/g 4

40 Thorium 234 4.32 3.967 1.11 1.13 pCi/g 9

40 Uranium 235 0.758 0.9068 0.220 0.244 pCi/g 18 40 Americium 241 0.0133 U

0.006286 U F 0.0699 0.117 pCi/g 72 40 Protactinium 234m 1.41 U

4.480 U F 3.48 5.52 pCi/g 104 40 TestAmerica St. Louis Page 16 of 19 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Metals Prep Batch: 46432 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-1974-1 L050103TUB00 Total/NA Solid None 160-1974-1 MS L050103TUB00 Total/NA Solid None 160-1974-1 MSD L050103TUB00 Total/NA Solid None 160-1974-2 L050104TUB00 Total/NA Solid None 160-1974-3 L050176TUB00 Total/NA Solid None 160-1974-4 L050177TUB00 Total/NA Solid None 160-1974-5 L050186TUB00 Total/NA Solid None 160-1974-6 L050187TUB00 Total/NA Solid None LCS 160-46432/2-A Lab Control Sample Total/NA Solid None MB 160-46432/1-A Method Blank Total/NA Analysis Batch: 47954 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 46432 160-1974-1 L050103TUB00 Total/NA Solid 6020A 46432 160-1974-1 MS L050103TUB00 Total/NA Solid 6020A 46432 160-1974-1 MSD L050103TUB00 Total/NA Solid 6020A 46432 160-1974-2 L050104TUB00 Total/NA Solid 6020A 46432 160-1974-3 L050176TUB00 Total/NA Solid 6020A 46432 160-1974-4 L050177TUB00 Total/NA Solid 6020A 46432 160-1974-5 L050186TUB00 Total/NA Solid 6020A 46432 160-1974-6 L050187TUB00 Total/NA Solid 6020A 46432 LCS 160-46432/2-A Lab Control Sample Total/NA Solid 6020A 46432 MB 160-46432/1-A Method Blank Total/NA General Chemistry Analysis Batch: 44123 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Moisture 160-1974-1 L050103TUB00 Total/NA Solid Moisture 160-1974-2 L050104TUB00 Total/NA Solid Moisture 160-1974-3 L050176TUB00 Total/NA Solid Moisture 160-1974-4 L050177TUB00 Total/NA Solid Moisture 160-1974-5 L050186TUB00 Total/NA Solid Moisture 160-1974-6 L050187TUB00 Total/NA Solid Moisture 160-1974-6 DU L050187TUB00 Total/NA Rad Leach Batch: 44137 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-1973-A-1-D DU Duplicate Total/NA Leach Batch: 44155 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-1974-1 L050103TUB00 Total/NA Solid Dry and Grind 160-1974-2 L050104TUB00 Total/NA Solid Dry and Grind 160-1974-3 L050176TUB00 Total/NA Solid Dry and Grind 160-1974-4 L050177TUB00 Total/NA Solid Dry and Grind 160-1974-5 L050186TUB00 Total/NA Solid Dry and Grind 160-1974-6 L050187TUB00 Total/NA TestAmerica St. Louis Page 17 of 19 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Rad (Continued)

Prep Batch: 44755 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-21 44137 160-1973-A-1-D DU Duplicate Total/NA Solid Fill_Geo-21 44155 160-1974-1 L050103TUB00 Total/NA Solid Fill_Geo-21 44155 160-1974-2 L050104TUB00 Total/NA Solid Fill_Geo-21 44155 160-1974-3 L050176TUB00 Total/NA Solid Fill_Geo-21 44155 160-1974-4 L050177TUB00 Total/NA Solid Fill_Geo-21 44155 160-1974-5 L050186TUB00 Total/NA Solid Fill_Geo-21 44155 160-1974-6 L050187TUB00 Total/NA Solid Fill_Geo-21 LCS 160-44755/2-A Lab Control Sample Total/NA Solid Fill_Geo-21 MB 160-44755/1-A Method Blank Total/NA Prep Batch: 46432 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-1974-1 L050103TUB00 Total/NA Solid None 160-1974-1 MS L050103TUB00 Total/NA Solid None 160-1974-1 MSD L050103TUB00 Total/NA Solid None 160-1974-2 L050104TUB00 Total/NA Solid None 160-1974-3 L050176TUB00 Total/NA Solid None 160-1974-4 L050177TUB00 Total/NA Solid None 160-1974-5 L050186TUB00 Total/NA Solid None 160-1974-6 L050187TUB00 Total/NA Solid None LCS 160-46432/2-A Lab Control Sample Total/NA Solid None MB 160-46432/1-A Method Blank Total/NA TestAmerica St. Louis Page 18 of 19 1

2 3

4 5

6 7

8 9

10 11 12

Tracer/Carrier Summary TestAmerica Job ID: 160-1974-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Prep Type: Total/NA Matrix: Solid Lab Sample ID Client Sample ID (30-110)

Re 90 160-1974-1 Percent Yield (Acceptance Limits)

L050103TUB00 93 160-1974-1 MS L050103TUB00 92 160-1974-1 MSD L050103TUB00 90 160-1974-2 L050104TUB00 93 160-1974-3 L050176TUB00 87 160-1974-4 L050177TUB00 90 160-1974-5 L050186TUB00 89 160-1974-6 L050187TUB00 97 LCS 160-46432/2-A Lab Control Sample 98 MB 160-46432/1-A Method Blank Tracer/Carrier Legend Re = Re TestAmerica St. Louis Page 19 of 19 1