ANALYTICAL REPORT TestAmerica Laboratories, Inc.

TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-4106-1 Client Project/Site: RFP-CBA-022 (7 DAY TAT)

For:

Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by:

10/18/2013 3:22:27 PM Ivan Vania, Project Manager I (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.

Results relate only to the items tested and the sample(s) as received by the laboratory.

1 2

3 4

5 6

7 8

9 10 11 12

Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

TestAmerica Job ID: 160-4106-1 Page 2 of 18 Cover Page..............................................

1 Table of Contents.........................................

2 Case Narrative...........................................

3 Chain of Custody..........................................

5 Receipt Checklists.........................................

6 Definitions/Glossary.......................................

7 Method Summary.........................................

8 Sample Summary.........................................

9 Client Sample Results......................................

10 QC Sample Results........................................

13 QC Association Summary...................................

16 Tracer Carrier Summary....................................

18 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4106-1 Project/Site: RFP-CBA-022 (7 DAY TAT)

Job ID: 160-4106-1 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (7 DAY TAT)

Report Number: 160-4106-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.

TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.

The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.

Calculations are performed before rounding to avoid round-off errors in calculated results.

All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.

All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %

solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.

This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.

RECEIPT The samples were received on 10/14/2013; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 4.0 C.

TECHNETIUM-99 (ICPMS)

Samples L050349PUB00 (160-4106-1), L050350PUB00 (160-4106-2) and L050351PUB00 (160-4106-3) were analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A. The samples were prepared and analyzed on 10/15/2013.

No difficulties were encountered during the Tc-99 analysis. All quality control parameters were within the acceptance limits.

PERCENT SOLIDS Samples L050349PUB00 (160-4106-1), L050350PUB00 (160-4106-2) and L050351PUB00 (160-4106-3) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 10/15/2013.

No difficulties were encountered during the % solids analysis. All quality control parameters were within the acceptance limits.

TestAmerica St. Louis Page 3 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4106-1 Project/Site: RFP-CBA-022 (7 DAY TAT)

Job ID: 160-4106-1 (Continued)

Laboratory: TestAmerica St. Louis (Continued)

CESIUM-137 & OTHER GAMMA EMITTERS (GS)

Samples L050349PUB00 (160-4106-1), L050350PUB00 (160-4106-2) and L050351PUB00 (160-4106-3) were analyzed for Cesium-137

& Other Gamma Emitters (GS) in accordance with DOE GA-01-R. The samples were leached on 10/15/2013, and prepared and analyzed on 10/17/2013.

Preparation Batch 79501:

Radium-226 is reported in these samples at the clients request. Radium-226 is reported from the 609.31 keV line of bismuth-214.

Because the samples have not had a 21-day ingrowth, the activity for radium-226 is an estimated value and may be biased low. This bias is caused by the disruption of secular equilibrium between radium-226 and bismuth-214 by the loss of radon-222 during sample preparation. (160-4106-1 DU), (LCS 160-79501/2-A), (MB 160-79501/1-A), L050349PUB00 (160-4106-1), L050350PUB00 (160-4106-2),

L050351PUB00 (160-4106-3)

No other difficulties were encountered during the Gamma spec analysis. All other quality control parameters were within the acceptance limits.

TestAmerica St. Louis Page 4 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Page 5 of 18 1

2 3

4 5

6 7

8 9

10 11 12

!Procedure HDP-PR-QA-006, Chain of Custody Page 1 ofl Hematite Decommissioning Project !Revision: 3 I

I Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAlN OF CUSTODY Instructions: &lch time the container is transferred to another organization, a person from each Organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP.

CbainofCutodvlDNo. I F-101113-01 Pa2:e 1/1 Project Name:

Westinghouse Electric Company Contact Person:

Gerald Rood Phone Number:

314-810-3382 Sampler Name Jeff Hoffinan Sample ID L050349PUBOO L050350PUBOO L050351PUBOO Relinauished bz__::-

Company Name:

Date

)Time (Matrix 1011112013 I 15:201 s 10/11/2013 I 15:321 s 10/11/2013 I 15:391 s Date/Time

/rJ--llf-I 3

~

Total Laboratory Name:

TA-MO Laboratory Address:

13715 Rider Trail North

~ e:1---------------------1

  • B PhoneNo.

8 314-298-8566 1ii Laboratory Contact Person:

,::! Joe Walker Phone No.

708-870-8_453 Turn Around Time_

Rush (7 days)

Remarks l ILSA 05-03 Bias 1 ILSA 05-03 Bias l ILSA 05-03 Bias Cooler Temperature:

ill Cooler ID: I Shipper and Number:

Received bv:

Company Name:

Date/Timei1) !Comments: Please re-analyze samples after 21-days ingrowth

\\ 0<_ a" '?:J period.

tr" \\'o' Relinquished by:

Date/Time Date/Time

- --1,,

I

~ r /' J CompanY.Nam_e:' -/ -

1-e/~

{B'**J,;;,

Verified By:

Company Name:

~

~

~

~

1*1-----

Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-4106-1 Login Number: 4106 Question Answer Comment Creator: Clarke, Jill C List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.

True The cooler's custody seal, if present, is intact.

N/A Sample custody seals, if present, are intact.

True The cooler or samples do not appear to have been compromised or tampered with.

False Samples were received on ice.

True Cooler Temperature is acceptable.

True Cooler Temperature is recorded.

True COC is present.

True COC is filled out in ink and legible.

True COC is filled out with all pertinent information.

True Is the Field Sampler's name present on COC?

True There are no discrepancies between the containers received and the COC.

True Samples are received within Holding Time.

True Sample containers have legible labels.

True Containers are not broken or leaking.

True Sample collection date/times are provided.

True Appropriate sample containers are used.

True Sample bottles are completely filled.

True Sample Preservation Verified.

True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is

<6mm (1/4").

True Multiphasic samples are not present.

True Samples do not require splitting or compositing.

N/A Residual Chlorine Checked.

TestAmerica St. Louis Page 6 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Definitions/Glossary TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Qualifiers Rad Qualifier Description U

Indicates the analyte was analyzed for but not detected.

Qualifier Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation

%R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)

Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)

NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown)

PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)

RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)

TEQ Toxicity Equivalent Quotient (Dioxin)

TestAmerica St. Louis Page 7 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Method Summary TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method Method Description Laboratory Protocol SW846 6020A Metals (ICP/MS), Tc-99 TAL SL EPA Moisture Percent Moisture TAL SL SW846 6020A Metals (ICP/MS), Tc-99 in Activity TAL SL DOE GA-01-R Cesium-137 & Other Gamma Emitters (GS)

TAL SL Protocol

References:

DOE = U.S. Department of Energy EPA = US Environmental Protection Agency SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.

Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 8 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Sample Summary TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID Client Sample ID Received Collected Matrix 160-4106-1 L050349PUB00 Solid 10/11/13 15:20 10/14/13 18:30 160-4106-2 L050350PUB00 Solid 10/11/13 15:32 10/14/13 18:30 160-4106-3 L050351PUB00 Solid 10/11/13 15:39 10/14/13 18:30 TestAmerica St. Louis Page 9 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4106-1 Client Sample ID: L050349PUB00 Matrix: Solid Date Collected: 10/11/13 15:20 Percent Solids: 85.5 Date Received: 10/14/13 18:30 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000065 0.000020 mg/Kg

10/15/13 08:48 10/15/13 19:14 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.00761 U

(2+/-)

0.0170 (2+/-)

1 10/15/13 19:14 10/15/13 08:48 pCi/g 0.224 1.31 RL MDC

-0.0152 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 08:48 10/15/13 19:14 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.13 (2+/-)

0.166 (2+/-)

1 10/17/13 18:26 10/17/13 11:12 pCi/g 0.0962 RL MDC 0.120 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.101 0.0610 0.0609 U

0.0404 Americium 241 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.373 0.429 0.408 1.28 Bismuth 212 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.0631 0.123 0.0905 0.808 Bismuth 214 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.0778 0.159 0.0765 1.07 Lead 212 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.0773 0.137 0.0987 0.921 Lead 214 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.450 2.41 1.20 20.4 Potassium 40 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.737 0.448 0.447 U

0.347 Protactinium 231 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.0631 1.00 0.123 0.0905 0.808 Radium 226 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.821 1.00 0.685 0.661 1.73 Thorium 234 pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.226 0.129 0.128 U

0.154 Uranium 235 pCi/g 10/17/13 11:12 10/17/13 18:26 1

4.52 3.06 3.03 U

3.65 Protactinium 234m pCi/g 10/17/13 11:12 10/17/13 18:26 1

0.0962 0.166 0.120 1.13 Thorium 232 Tl-208 0.358 0.0482 0.0608 0.0348 pCi/g 10/17/13 11:12 10/17/13 18:26 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-4106-2 Client Sample ID: L050350PUB00 Matrix: Solid Date Collected: 10/11/13 15:32 Percent Solids: 85.6 Date Received: 10/14/13 18:30 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000067 0.000020 mg/Kg

10/15/13 08:48 10/15/13 19:17 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0475 U

(2+/-)

0.0187 (2+/-)

1 10/15/13 19:17 10/15/13 08:48 pCi/g 0.231 1.35 RL MDC

-0.0156 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 08:48 10/15/13 19:17 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 87 TestAmerica St. Louis Page 10 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4106-2 Client Sample ID: L050350PUB00 Matrix: Solid Date Collected: 10/11/13 15:32 Date Received: 10/14/13 18:30 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.20 (2+/-)

0.193 (2+/-)

1 10/17/13 18:27 10/17/13 11:12 pCi/g 0.117 RL MDC 0.149 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.107 1.37 1.37 U

-0.00613 Americium 241 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.431 0.470 0.450 1.29 Bismuth 212 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.0745 0.130 0.102 0.772 Bismuth 214 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.0608 0.175 0.0812 1.20 Lead 212 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.0710 0.138 0.0964 0.951 Lead 214 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.269 2.61 1.36 21.8 Potassium 40 pCi/g 10/17/13 11:12 10/17/13 18:27 1

1.22 0.264 0.257 U

0.521 Protactinium 231 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.0745 1.00 0.130 0.102 0.772 Radium 226 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.866 1.00 0.341 0.331 U

0.771 Thorium 234 pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.228 0.146 0.145 U

0.152 Uranium 235 pCi/g 10/17/13 11:12 10/17/13 18:27 1

5.79 3.45 3.41 U

5.20 Protactinium 234m pCi/g 10/17/13 11:12 10/17/13 18:27 1

0.117 0.193 0.149 1.20 Thorium 232 Tl-208 0.401 0.0517 0.0664 0.0349 pCi/g 10/17/13 11:12 10/17/13 18:27 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-4106-3 Client Sample ID: L050351PUB00 Matrix: Solid Date Collected: 10/11/13 15:39 Percent Solids: 89.8 Date Received: 10/14/13 18:30 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000062 0.000019 mg/Kg

10/15/13 08:48 10/15/13 19:21 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0418 U

(2+/-)

0.0210 (2+/-)

1 10/15/13 19:21 10/15/13 08:48 pCi/g 0.212 1.24 RL MDC

-0.0184 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 10/15/13 08:48 10/15/13 19:21 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.03 (2+/-)

0.181 (2+/-)

1 10/17/13 18:28 10/17/13 11:12 pCi/g 0.134 RL MDC 0.147 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.124 0.0746 0.0745 U

-0.0375 Americium 241 pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.349 0.423 0.402 1.27 Bismuth 212 pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.0660 0.131 0.101 0.795 Bismuth 214 pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.0655 0.158 0.0807 1.05 Lead 212 pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.0771 0.130 0.0900 0.903 Lead 214 pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.486 2.47 1.43 19.7 Potassium 40 pCi/g 10/17/13 11:12 10/17/13 18:28 1

1.34 0.810 0.807 U

-0.582 Protactinium 231 pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.0660 1.00 0.131 0.101 0.795 Radium 226 TestAmerica St. Louis Page 11 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4106-3 Client Sample ID: L050351PUB00 Matrix: Solid Date Collected: 10/11/13 15:39 Date Received: 10/14/13 18:30 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)

Analyte Thorium 234 1.09 (2+/-)

0.394 (2+/-)

1 10/17/13 18:28 10/17/13 11:12 pCi/g 0.952 1.00 RL MDC 0.378 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.275 0.167 0.166 U

0.199 Uranium 235 pCi/g 10/17/13 11:12 10/17/13 18:28 1

5.81 3.56 3.55 U

2.95 Protactinium 234m pCi/g 10/17/13 11:12 10/17/13 18:28 1

0.134 0.181 0.147 1.03 Thorium 232 Tl-208 0.340 0.0563 0.0664 0.0434 pCi/g 10/17/13 11:12 10/17/13 18:28 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

TestAmerica St. Louis Page 12 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 Client Sample ID: Method Blank Lab Sample ID: MB 160-78991/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 78991 RL MDL Technetium 99 ND 0.000054 0.000016 mg/Kg 10/15/13 08:48 10/15/13 18:35 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-78991/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 78991 Technetium 99 0.00234 0.00222 mg/Kg 95 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: Matrix Spike Lab Sample ID: 160-4070-A-1-D MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 78991 Technetium 99 ND 0.00304 0.00277 mg/Kg 91 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4070-A-1-E MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 79106 Prep Batch: 78991 Technetium 99 ND 0.00304 0.00294 mg/Kg 97 75 - 125 6

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Client Sample ID: Method Blank Lab Sample ID: MB 160-78991/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 78991 Technetium 99 Analyte U

1 10/15/13 18:35 10/15/13 08:48 pCi/g 0.186 MDC 1.08 RL 0.00895

-0.00720 (2+/-)

(2+/-)

MB

-0.04511 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Carrier Re 30 - 110 10/15/13 08:48 10/15/13 18:35 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 93 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-78991/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 78991 Technetium 99 Analyte 120 80 95 38.03 40.1 3.73 1.04 0.178 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 97 LCS TestAmerica St. Louis Page 13 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued)

Client Sample ID: Matrix Spike Lab Sample ID: 160-4070-A-1-D MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 78991 Technetium 99 Analyte 125 75 91 47.43 52.1

-0.0493 U

5.05 1.41 0.241 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 93 MS Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4070-A-1-E MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 79107 Prep Batch: 78991 Technetium 99 Analyte 1

0.28 125 75 97 50.27 52.0

-0.0493 U

5.12 1.42 0.243 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 91 MSD Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Client Sample ID: Method Blank Lab Sample ID: MB 160-79501/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79554 Prep Batch: 79501 Actinium 228 Analyte U

1 10/17/13 18:20 10/17/13 11:12 pCi/g 0.0414 MDC RL 0.0159 0.0159 (2+/-)

(2+/-)

MB 0.001687 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0235 0.0129 0.0129 U

0.002547 Americium 241 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.130 0.0352 0.0352 U

0.0000 Bismuth 212 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0322 0.488 0.488 U

-0.01219 Bismuth 214 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0267 0.0426 0.0426 U

-0.004140 Lead 212 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0286 0.0146 0.0146 U

0.001151 Lead 214 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.560 3.47 3.47 U

-0.08670 Potassium 40 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.386 0.199 0.199 U

-0.002253 Protactinium 231 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0322 1.00 0.488 0.488 U

-0.01219 Radium 226 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.311 1.00 2.62 2.62 U

-0.1788 Thorium 234 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0498 0.0344 0.0341 U

0.04254 Uranium 235 1

10/17/13 18:20 10/17/13 11:12 pCi/g 2.04 1.32 1.31 U

1.093 Protactinium 234m 1

10/17/13 18:20 10/17/13 11:12 pCi/g 0.0414 0.0159 0.0159 U

0.001687 Thorium 232 Other Detected Radionuclide None MB (2+/-)

(2+/-)

MDC RL pCi/g 10/17/13 11:12 10/17/13 18:20 1

MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Radionuclides Other Detected TestAmerica St. Louis Page 14 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)

Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-79501/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 79494 Prep Batch: 79501 Americium 241 Analyte 116 87 93 90.52 97.7 9.42 0.477 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Cesium 137 31.6 30.08 3.15 0.200 0.117 pCi/g 95 87 - 120 Cobalt 60 24.3 22.72 2.29 0.0516 pCi/g 93 87 - 115 Client Sample ID: L050349PUB00 Lab Sample ID: 160-4106-1 DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 79494 Prep Batch: 79501 Actinium 228 Analyte 1

0.20 1.199 1.13 0.196 0.0776 RL MDC (2+/-)

DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.

Total RER RER Americium 241 0.0404 U

0.02742 U

0.0616 0.102 pCi/g 0.11 1

Bismuth 212 1.28 1.597 0.479 0.371 pCi/g 0.35 1

Bismuth 214 0.808 0.7293 0.118 0.0669 pCi/g 0.32 1

Lead 212 1.07 1.148 0.165 0.0549 pCi/g 0.23 1

Lead 214 0.921 0.8624 0.125 0.0743 pCi/g 0.22 1

Potassium 40 20.4 20.83 2.43 0.265 pCi/g 0.09 1

Protactinium 231 0.347 U

0.3749 U

0.463 0.759 pCi/g 0.03 1

Radium 226 0.808 0.7293 0.118 1.00 0.0669 pCi/g 0.32 1

Thorium 234 1.73 1.839 0.756 1.00 0.892 pCi/g 0.07 1

Uranium 235 0.154 U

0.1226 U

0.152 0.254 pCi/g 0.11 1

Protactinium 234m 3.65 U

5.942 3.23 4.78 pCi/g 0.36 1

Thorium 232 1.13 1.199 0.196 0.0776 pCi/g 0.20 1

TestAmerica St. Louis Page 15 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Metals Prep Batch: 78991 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4070-A-1-D MS Matrix Spike Total/NA Solid None 160-4070-A-1-E MSD Matrix Spike Duplicate Total/NA Solid None 160-4106-1 L050349PUB00 Total/NA Solid None 160-4106-2 L050350PUB00 Total/NA Solid None 160-4106-3 L050351PUB00 Total/NA Solid None LCS 160-78991/2-A Lab Control Sample Total/NA Solid None MB 160-78991/1-A Method Blank Total/NA Analysis Batch: 79106 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 78991 160-4070-A-1-D MS Matrix Spike Total/NA Solid 6020A 78991 160-4070-A-1-E MSD Matrix Spike Duplicate Total/NA Solid 6020A 78991 160-4106-1 L050349PUB00 Total/NA Solid 6020A 78991 160-4106-2 L050350PUB00 Total/NA Solid 6020A 78991 160-4106-3 L050351PUB00 Total/NA Solid 6020A 78991 LCS 160-78991/2-A Lab Control Sample Total/NA Solid 6020A 78991 MB 160-78991/1-A Method Blank Total/NA General Chemistry Analysis Batch: 78976 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Moisture 160-4105-A-1 DU Duplicate Total/NA Solid Moisture 160-4106-1 L050349PUB00 Total/NA Solid Moisture 160-4106-2 L050350PUB00 Total/NA Solid Moisture 160-4106-3 L050351PUB00 Total/NA Rad Prep Batch: 78991 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4070-A-1-D MS Matrix Spike Total/NA Solid None 160-4070-A-1-E MSD Matrix Spike Duplicate Total/NA Solid None 160-4106-1 L050349PUB00 Total/NA Solid None 160-4106-2 L050350PUB00 Total/NA Solid None 160-4106-3 L050351PUB00 Total/NA Solid None LCS 160-78991/2-A Lab Control Sample Total/NA Solid None MB 160-78991/1-A Method Blank Total/NA Leach Batch: 79041 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-4106-1 L050349PUB00 Total/NA Solid Dry and Grind 160-4106-1 DU L050349PUB00 Total/NA Solid Dry and Grind 160-4106-2 L050350PUB00 Total/NA Solid Dry and Grind 160-4106-3 L050351PUB00 Total/NA Prep Batch: 79501 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-0 79041 160-4106-1 L050349PUB00 Total/NA Solid Fill_Geo-0 79041 160-4106-1 DU L050349PUB00 Total/NA TestAmerica St. Louis Page 16 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Rad (Continued)

Prep Batch: 79501 (Continued)

Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-0 79041 160-4106-2 L050350PUB00 Total/NA Solid Fill_Geo-0 79041 160-4106-3 L050351PUB00 Total/NA Solid Fill_Geo-0 LCS 160-79501/2-A Lab Control Sample Total/NA Solid Fill_Geo-0 MB 160-79501/1-A Method Blank Total/NA TestAmerica St. Louis Page 17 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Tracer/Carrier Summary TestAmerica Job ID: 160-4106-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Prep Type: Total/NA Matrix: Solid Lab Sample ID Client Sample ID (30-110)

Re 93 160-4070-A-1-D MS Percent Yield (Acceptance Limits)

Matrix Spike 91 160-4070-A-1-E MSD Matrix Spike Duplicate 90 160-4106-1 L050349PUB00 87 160-4106-2 L050350PUB00 90 160-4106-3 L050351PUB00 97 LCS 160-78991/2-A Lab Control Sample 93 MB 160-78991/1-A Method Blank Tracer/Carrier Legend Re = Re TestAmerica St. Louis Page 18 of 18 1

2 3

4 5

6 7

8 9

10 11 12