Request for Additional Information for the Review of the Browns Ferry Nuclear Plant, Units 1, 2 and 3, License Renewal Application
ML043500508
Person / Time
Site: Browns Ferry  
(DPR-033, DPR-052, DPR-068)
Issue date: 12/14/2004
From: Yoira Diaz-Sanabria
NRC/NRR/DRIP/RLEP
To: Singer K
Tennessee Valley Authority
Subbaratnam R, NRR/DRIP/RLEP, 415-14
References
TAC MC1704, TAC MC1705, TAC MC1706
Download: ML043500508 (6)


Text

December 14, 2004 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE BROWNS FERRY NUCLEAR PLANT, UNITS 1, 2, AND 3, LICENSE RENEWAL APPLICATION (TAC NOS. MC1704, MC1705, AND MC1706)

Dear Mr. Singer:

By letter dated December 31, 2003, Tennessee Valley Authority (TVA) submitted an application pursuant to 10 CFR Part 54, to renew the operating licenses for the Browns Ferry Nuclear Plant, Units 1, 2, and 3, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified areas where additional information is needed to complete the review.

Specifically, the enclosed request for additional information (RAI) is related to the time-limited aging analysis (TLAA) for the reactor building crane load cycles, Section 4.7.1.

Based on discussions with Ken Brune of your staff, a mutually agreeable date for your response to the RAIs is within 30 days from the date of this letter. If you have any questions regarding this letter or if circumstances result in your need to revise the response date, please contact me at 301-415-1594 or by e-mail at yks@nrc.gov.

Sincerely,

/RA/

Yoira K. Diaz Sanabria, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-259, 50-260, and 50-296

Enclosure:

As stated cc w/encl: See next page

December 14, 2004 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE BROWNS FERRY NUCLEAR PLANT, UNITS 1, 2, AND 3, LICENSE RENEWAL APPLICATION (TAC NOS. MC1704, MC1705, AND MC1706)

Dear Mr. Singer:

By letter dated December 31, 2003, Tennessee Valley Authority (TVA) submitted an application pursuant to 10 CFR Part 54, to renew the operating licenses for the Browns Ferry Nuclear Plant, Units 1, 2, and 3, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified areas where additional information is needed to complete the review.

Specifically, the enclosed request for additional information (RAI) is related to the time-limited aging analysis (TLAA) for the reactor building crane load cycles, Section 4.7.1.

Based on discussions with Ken Brune of your staff, a mutually agreeable date for your response to the RAIs is within 30 days from the date of this letter. If you have any questions regarding this letter or if circumstances result in your need to revise the response date, please contact me at 301-415-1594 or by e-mail at yks@nrc.gov.

Sincerely,

/RA/

Yoira K. Diaz Sanabria, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-259, 50-260, and 50-296

Enclosure:

As stated cc w/encl: See next page ADAMS accession no.: ML043500508 DISTRIBUTION: See next page Document Name: E:\\Filenet\\ML043500508.wpd OFFICE PM:RLEP PM:RLEP LA:RLEP SC:DE SC:RLEP NAME YDiaz-Sanabria RSubbaratnam YEdmonds KManoly SLee DATE 12/14/04 12/14/04 12/13/04 8/31/04 12/14/04 OFFICIAL RECORD ONLY

DISTRIBUTION: Ltr to K. Singer, TVA, RAI Re: Browns Ferry Nuclear Plant, Units 1, 2 and 3, Dated: December 14, 2004, Accession No: ML043500508 HARD COPY:

RLEP RF Yoira Diaz-Sanabria (PM)

Ram Subbaratnam (PM)

E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti K. Naidu C. Li M. Itzkowitz (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff K. Jabbour C. Julian (RII)

S. Cahill (RII)

A. Hodgdon C. Carpenter D. Coe E. Kleeh A. Howe R. McNally

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION SECTION 4.7.1 RAI 4.7.1-1 Reactor Building Crane Load Cycles Section 4.7.1 of the LRA, describes the analysis of the reactor building crane. This section states that the total number of expected cycles for this crane over the entire life including construction, is 60 years of operation for all three units. This includes decommissioning which is conservatively estimated at less than 21,000 loading cycles. LRA aging management program (AMP), B.2.1.20, includes an evaluation of the reactor building crane fatigue. It states that the disposition of the time-limited aging analysis (TLAA) is that the analyses are valid through the period of extended operation because the 60 year, 7,500 cycle estimate remains a small fraction of the 100,000 cycle design. TVA letter to the NRC dated September 28, 1982, in response to NUREG-0612, states that the structural and rotating parts of the crane were designed for infinite life. Clarify if infinite life is still valid or explain the derivation for the total number of loading cycles estimated for the reactor building crane. Also, explain the difference between the 21,000 cycles estimated in LRA Section 4.7.1 and the 7,500 cycles estimated in LRA Section B.2.1.20. If the crane design does not provide for infinite life, clarify if additional loading cycles caused by vibration during crane operation are considered in the analysis or the basis for not including loading cycles induced by vibration.

Enclosure

Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT cc:

Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Ashok S. Bhatnagar, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Michael J. Lorek, General Manager Nuclear Engineering Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Michael D. Skaggs, Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. John C. Fornicola, Manager Nuclear Assurance and Licensing Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Kurt L. Krueger, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Jon R. Rupert, Vice President Browns Ferry Unit 1 Restart Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Robert G. Jones Browns Ferry Unit 1 Plant Restart Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Fredrick C. Mashburn, Senior Program Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Timothy E. Abney, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Bobby L. Holbrook Senior Resident Inspector U.S. Nuclear Regulatory Commission Browns Ferry Nuclear Plant 10833 Shaw Road Athens, AL 35611-6970

Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT cc:

State Health Officer Alabama Dept. of Public Health RSA Tower - Administration Suite 1552 P.O. Box 303017 Montgomery, AL 36130-3017 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611 Mr. Fred Emerson Nuclear Energy Institute 1776 I St., NW, Suite 400 Washington, DC 20006-2708 Ken Brune, Manager Browns Ferry License Renewal Project Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801