Text

November 1, 2004 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE BROWNS FERRY NUCLEAR PLANT, UNITS 1, 2 AND 3, LICENSE RENEWAL APPLICATION (TAC NOS. MC1704, MC1705 AND MC1706)

Dear Mr. Singer:

By letter dated December 31, 2003, Tennessee Valley Authority (TVA) submitted an application pursuant to 10 CFR Part 54, to renew the operating licenses for the Browns Ferry Nuclear Plant, Units 1, 2 and 3, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified areas where additional information is needed to complete the review.

Specifically, the enclosed requests for additional information (RAIs) are related to the Electrical and Instrumentation & Control Systems (I&C), Section 2.5.

Based on discussions with Ken Brune of your staff, a mutually agreeable date for your response to the RAIs is within 30 days from the date of this letter. If you have any questions regarding this letter or if circumstances result in your need to revise the response date, please contact me at 301-415-1594 or by e-mail at yks@nrc.gov.

Sincerely,

/RA/

Yoira K. Diaz-Sanabria, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-259, 50-260 and 50-296

Enclosure:

As stated cc w/encl: See next page

November 1, 2004 Mr. Karl W. Singer Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE BROWNS FERRY NUCLEAR PLANT, UNITS 1, 2 AND 3, LICENSE RENEWAL APPLICATION (TAC NOS. MC1704, MC1705 AND MC1706)

Dear Mr. Singer:

By letter dated December 31, 2003, Tennessee Valley Authority (TVA) submitted an application pursuant to 10 CFR Part 54, to renew the operating licenses for the Browns Ferry Nuclear Plant, Units 1, 2 and 3, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified areas where additional information is needed to complete the review.

Specifically, the enclosed requests for additional information (RAIs) are related to the Electrical and Instrumentation & Control Systems (I&C), Section 2.5.

Based on discussions with Ken Brune of your staff, a mutually agreeable date for your response to the RAIs is within 30 days from the date of this letter. If you have any questions regarding this letter or if circumstances result in your need to revise the response date, please contact me at 301-415-1594 or by e-mail at yks@nrc.gov.

Sincerely,

/RA/

Yoira K. Diaz-Sanabria, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-259, 50-260 and 50-296

Enclosure:

As stated cc w/encl: See next page ADAMS Accession no. ML043060492 DISTRIBUTION: See next page

  • Input provided by memo Document Name: E:\\Filenet\\ML043060492.wpd OFFICE PM:RLEP PM:RLEP LA:RLEP SC:EEIB SC:RLEP NAME YDiaz-Sanabria RSubbaratnam YEdmonds RJenkins*

SLee DATE 10/29/04 10/29/04 10/29/04 9/27/04 11/1/04 OFFICIAL RECORD ONLY

DISTRIBUTION: Dated: November 1, 2004 Accession No.: ML043060492 HARD COPY:

RLEP RF Yoira Diaz-Sanabria (PM)

Ram Subbaratnam (PM)

E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti K. Naidu C. Li M. Itzkowitz (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff K. Jabbour C. Julian (RII)

S. Cahill (RII)

A. Hodgdon C. Carpenter D. Coe E. Kleeh A. Howe A. Pal J. Lazevnick

Enclosure BROWNS FERRY NUCLEAR, UNITS 1, 2 AND 3 LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION (RAI)

ELECTRICAL AND INSTRUMENTATION AND CONTROL SYSTEMS SECTION 2.5 RAI 2.5-1 Section 2.5.1 of the LRA states that scoping and screening of electrical and I&C components was performed using the spaces approach described in Section 2.1. Were all plant spaces evaluated under this methodology? If any spaces were excluded from evaluation identify those spaces that were excluded and provide the reason why each space was excluded.

RAI 2.5-2 Section 2.5.1 of the LRA states that if a component in a commodity group existed in an area where the area conditions exceeded the commodity groups limiting environmental parameters, a further evaluation could be performed to determine if the component was required for an in-scope systems intended function. Identify all the components that were excluded from the scope of license renewal as a result of these further evaluations and provide the basis used for excluding each component.

RAI 2.5-3 On the three license renewal drawings identified in LRA Section 2.5.1 that depict the recovery path for station blackout (SBO), identify the location of each commodity group component in the recovery path circuit. Do the SBO recovery path circuits include the control circuit wiring that is associated with the power circuits shown on the drawings? If not, why? Are there any underground power circuits used in the SBO recovery paths? If so, were they identified as requiring an AMR? If not, why?

RAI 2.5-4 During a telephone conference held on July 28, 2004, in response to draft request for additional information, D-RAI 3.6-3, the applicant stated that in 1997 a XLPE insulated CCWP capacitor bank cable failed in-service at BFN. Why were these cables not included within the scope of license renewal and identified as a component that requires an AMR?

Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT cc:

Mr. Ashok S. Bhatnagar, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. James E. Maddox, Vice President Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Michael D. Skaggs, Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. John C. Fornicola, Manager Nuclear Assurance and Licensing Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Kurt L. Krueger, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Jon R. Rupert, Vice President Browns Ferry Unit 1 Restart Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Robert G. Jones Browns Ferry Unit 1 Plant Restart Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Timothy E. Abney, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Bobby L. Holbrook Senior Resident Inspector U.S. Nuclear Regulatory Commission Browns Ferry Nuclear Plant 10833 Shaw Road Athens, AL 35611-6970 State Health Officer Alabama Dept. of Public Health RSA Tower - Administration Suite 1552 P.O. Box 303017 Montgomery, AL 36130-3017 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611 Mr. Fred Emerson Nuclear Energy Institute 1776 I St., NW, Suite 400 Washington, DC 20006-2708