S Duke Duke Energy Corporation McGuire Nuclear Station AD E12700 Hagers Ferry Road Huntersville, NC 28078-9340 H. B. Barron (704) 875-4800 OFFICE Vice President (704) 875-4809 FAX February 26, 2002 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Re:
McGuire Nuclear Station Unit 1 Docket No.
50-369 McGuire Nuclear Station Unit 2 Docket No.
50-370 Changes to Emergency Plan Implementing Procedures Attached to this letter is a revised Emergency Plan Implementing Procedure (EPIP) Index and revised Emergency Plan Implementing Procedures.
The procedure changes were evaluated pursuant to the requirements of 10 CFR 50.54 (q).
These changes do not constitute a reduction in the effectiveness of the emergency plan and the plan continues to meet the requirements of 10 CFR 50.47 (b) and 10 CFR 50 Appendix E.
Duke implemented these changes on February 5, 2002.
A copy is also being sent to the NRC Office of Nuclear Material Safety and Safeguards as per 10 CFR 72.44 (f).
Revision bars in the procedures indicate the procedure changes.
The following index and procedure changes have been implemented:
EPIP Index Page 1 HP/0/B/1009/022 Rev.
003 EPIP Index Page 2 HP/O/B/1009/023 Rev.
004 EPIP Index Page 3 PT/0/A/4600/088 Rev.
007 There are no new regulatory commitments in this document.
Duke is also supplying two copies of this submittal to the Regional Administrator of Region II.
Questions on this document should be directed to Kevin Murray at (704) 875-4672.
Very truly yours, H.
B.
Barron HBB:jcm Attachments
&0
U.S. Nuclear Regulatory Commission February 26, 2002 Page 2 xc:
(w/attachment)
Mr.
Luis Reyes, Regional Administrator U.S. Nuclear Regulatory Commission Region II 61 Forsyth St.,
SW, Suite 23T85 Atlanta, Georgia 30303 (w/attachment)
Mr. Martin J.
Virgilio, Director Office of Nuclear Material Safety and Safeguards Mail Stop T-8A23 Washington, D.C. 20555-0001 (w/o attachment)
NRC Resident Inspector R.
E. Martin, USNRC Mike Wilder (ECO50)
Electronic Licensing Library (EC050)
EP File 111
DUKE McGUIRE NUCLEAR SITE EMERGENCY PLAN IMPLEMENTING PROCEDURES APPROVED:
S4*Y SSURANCE MANAGER DATE APPROVED z4 A.o I-EPIP Index Page EPIP Index Page EPIP Index Page HP/0/B/1009/022 HP/0/B/1009/023 PT/0/A/4600/088 1
2 3
Dated Dated Dated Dated Dated Dated 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
RP/0/A15700/000 RP/0/A/5700/001 RP/0/A/5700/002 RP/0/A/5700/003 RP/0/A/5700/004 RP/O/A15700/05 RP/0/A/5700/006 RP/O/A/5700/007 RP/O/A15700/008 RP/O/A15700/009 RP/0/A/5700/010 RP/0/A/5700/011 RP/O/A/5700/012 RP/0/A/5700/013 RP/O/A/5700/14 RP/0/A/5700/015 RP/0/A15700/16 RP/O/A15700/17 RP/0/A/5700/018 RP/0/A/5700/019 RP/O/A/5700/020 RP/0/A/5700/21 RP/O/A15700/022 RP/O/A/5700/024 RP/O/A15700/026 RP/0/B/5700/023 OP/0/B/6200/090 TITLE Classification of Emergency Notification of Unusual Event Alert Site Area Emergency General Emergency Care and Transportation of Contaminated Injured Individual(s) From Site to Offsite Medical Facility Natural Disasters Earthquake Release of Toxic or Flammable Gases Collisions/Explosions NRC Immediate Notification Requirements Conducting a Site Assembly, Site Evacuation or Containment Evacuation Activation of the Technical Support Center (TSC)
Activation of the Emergency Operations Facility (EOF)
Emergency Telephone Directory Notifications to the State and Counties from the EOF EOF Commodities and Facilities Procedure Emergency Data Transmittal System Access Notifications to the State and Counties from the TSC Core Damage Assessment Activation of the Operations Support Center (OSC)
EOF Access Control Spill Response Procedure Recovery and Reentry Procedure Operations/Engineering Technical Evaluations in the Technical Support Center (TSC)
Community Relations Emergency Response Plan PALSS Operation for Accident Sampling February 5, 2002 Rev. 25 REVISION NUMBER Rev. 008 Rev. 016 Rev. 016 Rev. 016 Rev. 016 DELETE Rev. 009 Rev. 007 Rev. 004 Rev. 001 Rev. 013 Rev. 005 Rev. 019 DELETE DELETE DELETE DELETE DELETE Rev. 010 Rev. 003 Rev. 011 DELETE Rev. 009 Rev. 002 Rev. 002 Rev. 002 Rev. 010 I
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
HP/O/B/1009/002 HP/0/B/1009/003 HP/O/B/1009/05 HP/0/B/1009/006 HP/O/B/1009/010 HP/1/B/1009/015 HP/2/B/1009/015 HP/O/B/1009/016 HP/0/B/1009/020 HP/0/BI/1009/021 HP/0/B/1009/022 HP/0/B/1009/023 HP/0/B/1009/024 HP/O/B/1009/029 SHIO/B/2005/001 SH/0/B/2005/002 SR/O/B/2000/01 SR/0/B/2000/002 SR/0/B/2000/003 SR/O/B/2000/004 TITLE Alternative Method for Determining Dose Rate Within the Reactor Building Recovery Plan Initial Evaluation of Protective Action Guides Due to Abnormal Plant Conditions Procedure for Quantifying High Level Radioactivity Releases During Accident Conditions Releases of Radioactive Effluents Exceeding Selected Licensee Commitments Unit 1 Nuclear Post-Accident Containment Air Sampling System Operating Procedure Unit 2 Nuclear Post-Accident Containment Air Sampling System Operating Procedure Distribution of Potassium Iodide Tablets in the Event of a Radioiodine Release Manual Procedure for Offsite Dose Projections Estimating Food Chain Doses Under Post-Accident Conditions Accident and Emergency Response Environmental Monitoring for Emergency Conditions Personnel Monitoring for Emergency Conditions Initial Response On-Shift Dose Assessment Emergency Response Offsite Dose Projections Protocol for the Field Monitoring Coordinator During Emergency Conditions Standard Procedure for Public Affairs Response to the Emergency Operations Facility Standard Procedure for EOF Commodities and Facilities Activation of the Emergency Operations Facility Notification to States and Counties from the Emergency Operations Facility February 5, 2002 Rev. 25 REVISION NUMBER Rev. 002 Rev. 003 DELETED Rev. 005 Rev. 006 Rev. 003 Rev. 003 Rev. 002 DELETED Rev. 001 Rev. 003 Rev. 004 Rev. 001 Rev. 005 Rev. 001 Rev. 001 Rev. 003 Rev. 002 Rev. 008 Rev. 004 2
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
McGuire Site Directive 280 EP Group Manual MNS RP Manual:
PT/O/A/4600/088 TITLE Site Assembly/Accountability and Evacuation/Containment Evacuation Section 1.1 Emergency Organization Section 18.1 Accident and Emergency Response Section 18.2 Environmental Monitoring for Emergency Conditions Section 18.3 Personnel Monitoring for Emergency Conditions Section 18.4 Planned Emergency Exposure Functional Check of Emergency Vehicle and Equipment February 5, 2002 Rev. 25 REVISION NUMBER DELETED Rev. 017 DELETED DELETED DELETED DELETED Rev. 007 3
(R04-01)
Duke Power Company PROCEDURE PROCESS RECORD (1) ID No. HP/O/B/1009/022 Revision No.
003 PREPARATION (2) Station (3) Procedure Title McGuire Nuclear Station Accident and Emergency Response (4) Prepared By Gary Terrell A.&4Aý-
(5) Requires NSD 228 Applicability Determination?
0 Yes (New procedure or revision with major changes)
L1 No (Revision with minor changes)
F1 No (To incorporat previously approved changes)
(6) Reviewed By (OR)
Cross-Disciplinary Review By (OR) NA Reactivity Mgmt. Review By (OR) NA Mgmt. Involvement Review By (OPS Supt.) N A
(7) Additional Reviews Reviewed Bye, Reviewed By Date January 23, 2002 Date f-Z3-0Z_
Date I-F3-0 Date 1-23-oz Date 1-73-0z Date/316"2 Date (8) Temporary Approval (if necessary)
By By (9) Approved By (OSM) Date (OR) Date Date___________
PERFORMANCE (Compare with Control Copy every 14 calendar days while work is being performed.)
(10) Compared with Control Copy Date Compared with Control Copy Date Compared with Control Copy Date (11) Date(s) Performed Work Order Number (WO#)
COMPLETION (12) Procedure Completion Verification EL Yes El NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?
[I Yes 0I NA Required enclosures attached?
E] Yes EL NA Data sheets attached, completed, dated and signed?
EL Yes EL NA Charts, graphs, etc. attached, dated, identified, and marked?
[] Yes EL NA Procedure requirements met?
Verified By Date (13) Procedure Completion Approved Date_
(14) Remarks (Attach additional pages, if necessary.)
Form based on NSD 703 App D (Procedure Process Record)
A
Duke Power Company McGuire Nuclear Station Accident and Emergency Response Information Use Procedure No.
HP/O/B/ 1009/022 Revision No.
003 Electronic Reference No.
MC0095LX
HP/O/B/1009/022 Page 2 of 10 Accident and Emergency Response
- 1. Purpose This procedure describes the actions to be taken by personnel to effectively and efficiently cope with a variety of accident conditions. Responses for the following accidents are included in this procedure:
1.1 Spills 1.2 Airborne releases 1.3 Personnel injury involving contamination 1.4 Fires in the Restricted Area 1.5 New Fuel Storage - Inadvertent Criticality Event 1.6 Kr-85 Hazard following a spent fuel accident The level of use for this procedure is Reference Use.
- 2. References 2.1 SH/0/B/2001/003, Investigation of Skin and Clothing Contaminations 2.2 HP/O/B/1008/010, Airborne Radioactivity Control and Accountability 2.3 HP/0/B/1009/023, Environmental Monitoring for Emergency Conditions 2.4 Radiation Protection Policy Manual, Policy Number 11-02, Planned Special Exposures and Emergency Dose Limits for Occupationally Exposed Personnel 2.5 Radiation Protection Policy Manual, Policy Number IU-01, Occupational Dose Limits 2.6 SIH0/B/2000/005, Posting of Radiation Control Zones 2.7 Nuclear System Directive 112, Fire Brigade Organization, Training Responsibilities 2.8 SH/0/B/2000/004, Taking, Counting, and Recording Surveys 2.9 HP/0/B/1009/003, Recovery Plan 2.10 SH/O/B/2001/004, Investigation of Unusual Radiological Occurrences
HP/0/B/1l009/022 Page 3 of 10
- 3. Limits and Precautions 3.1 The Station Radiation Protection Manager (RPM) or his designee shall determine the need for high range personnel and/or extremity dosimetry and respiratory protection prior to any recovery personnel entering the plant after an accident/incident.
3.2 In accident conditions where exposure in excess of normal quarterly limits is anticipated, i.e., planned emergency exposure, refer to Radiation Protection Policy Manual Policy Number 11-02 (Reference 2.4).
3.3 Personnel decontamination shall NOT take precedence over proper medical/surgical care.
3.4 The Station Radiation Protection Manager is to be notified as soon as possible of all incidents involving radioactive materials (spills, leaks, source breakage, loss, etc.) and of all radiation accidents, accidental releases, or injuries to personnel (wounds, contamination, overexposure, ingestion or inhalation of radioactive material).
4.1.1.1 Stop the spill - by righting the container; isolating the system, if possible.
4.1.1.2 Warn others - notify other personnel in the area or who may be affected by the spill and Radiation Protection.
4.1.1.3 Isolate the area - through the use of barricades, signs, etc.
4.1.1.4 Minimize exposure and contamination spread - using only those personnel necessary for cleanup and utilizing absorbent material at the outer edges.
4.1.1.5 Secure unfiltered exhaust and all supply ventilation in cases where airborne contamination may be a problem.
4.1.2 Major Spills 4.1.2.1 Handle as in 4.1.1.
4.1.2.2 Notify the Operations Shift Manager/Designee of the circumstances.
HP/0/B/1009/022 Page 4 of 10 4.1.2.3 IF the spill is uncontrollable or CANNOT be contained inside the RCA notify the Station Radiation Protection Manager as soon as possible.
4.1.2.4 IF the spill is uncontrollable and CANNOT be completely decontaminated, maintain documentation as required by Reference 2.10.
4.2 Inadvertent release of radioactive particulates and/or iodines within the Radiation Control Area.
4.2.1 Notify all persons to vacate the room or immediate areas at once, and to proceed to the nearest safe location, taking care NOT to spread contamination unnecessarily.
4.2.2 Notify the Operations Shift Manager/Designee immediately.
4.2.3 Notify Radiation Protection Supervision immediately and report all known or suspected inhalation of radioactive materials. Assume that all persons immediately involved were exposed.
4.2.4 Proceed to nearest contaminated change room.
4.2.5 Take immediate steps to monitor and decontaminate personnel involved.
4.2.6 Radiation Protection shall:
4.2.6.1 Monitor all persons suspected of being contaminated, and assist with their decontamination.
4.2.6.2 Take immediate steps to evaluate the radiological situation, and determine the requirements to reenter the area.
4.2.6.3 Determine the cause of the contamination, and take steps to remedy the situation.
4.2.6.4 Supervise reentry, decontamination and recovery work.
4.2.6.5 Approve or limit further use of the area or equipment involved.
4.2.6.6 Perform a complete survey of the area before permitting resumption of work, after decontamination and cleanup have been completed.
4.2.6.7 Prepare records of the incident, for station records and report purposes.
HP/0/B/ 1009/022 Page 5 of 10 4.2.6.8 Notify the Compliance Engineer about the incident and reports.
4.3 Personnel injury involving radiation or radioactive materials.
4.3.1 In the event of an injury involving radiation or radioactive materials notify the Operations Shift Manager/Designee immediately.
4.3.2 Evaluate the radiological implications and assist in radiation and contamination control and in decontaminating personnel as necessary per SH/0/B/2001/003 (Reference 2.1).
4.3.3 In case of severe injury, decontamination shall NOT interfere with or take precedence over proper medical and surgical care.
NOTE:
MERT responders are responsible for all decisions involving patient care, including the need for transportation to an off-site facility.
4.3.3.1 Notify the Operations Shift Manager/Designee of any special considerations (i.e., type of injury, contamination levels present, etc.). Operations Shift Manager/Designee will notify off-site facilities.
4.3.3.2 First aid shall be given, and a Senior Radiation Protection Technician shall accompany the injured person(s) to the doctor or hospital, taking precautions to prevent the spread of contamination. IF Radiation Protection personnel are available, one technician should accompany each vehicle transporting injured person.
4.3.3.3 IF a contaminated injury occurs during nights, weekends, or holidays notify one of the designated management personnel by telephone or emergency pager. A call list is posted in the Shift Lab and at the Field Operations duty desk. RP Management will meet the Senior RP Technician at the medical facility.
4.3.3.4 In all cases, where injuries or illnesses have occurred within the RCA, documentation of the event shall be performed by a Senior Radiation Protection Specialist or Senior Contract Technician.
4.3.3.5 In situations where personnel have been decontaminated prior to transport to a medical facility, documentation of the event shall be performed per SH/0/B/2001/003 (Reference 2.1).
HP/O/B/1009/022 Page 6 of 10 4.3.3.6 In situations where personnel have NOT been contaminated as a result of injury or illness within the RCA, document the event on a blank survey form, stating that the injured/ill individual was evaluated for contamination and released.
4.3.3.7 Radiation Protection shall notify the Operations Shift Manager/Designee when the person has been deconned below station limits or determined to be free of contamination.
4.3.3.8 Upon completion of medical aid, Radiation Protection shall survey the medical facility for contamination and assist in any necessary decontamination to be performed.
4.3.3.9 Any liquid or debris either in the ambulance or at the medical facility that is found to be contaminated or has the possibility of being contaminated (i.e. liquid used to flush a contaminated wound) with byproduct material from McGuire Nuclear Station (MNS) must be deconned or brought back to MNS for processing. (The bag(s) will be tagged "Medical Waste", placed in a separate RCZ in Room 1202 and RMC will be contacted.)
4.4 Fires Within the Restricted Area 4.4.1 Nuclear System Directive 112 (Reference 2.7) requires that a minimum of one (1) Radiation Protection Technician trained to Radiation Protection Fire Response, respond to a fire or fire drill. WHEN an actual fire or fire drill in the Radiation Control Area is announced over the public address system (or beeper system) at least one person qualified to task RP-280 shall respond with the following equipment:
9 radio on channel 1 (located in Shift Lab)
- E-520 w/pancake probe, (located in Shift Lab)
- high range ion chamber and/or teletector, (located in Shift Lab)
- smears, (Shift fire response kit)
- air sampler (Shift fire response kit) 0 particulate and charcoal cartridges (Shift fire response kit)
- 50 foot extension cord (Shift fire response kit)
HP/0/B/1009/022 Page 7 of 10 4.4.1.1 At first notification of a fire outside the RCA but inside the restricted area, RP technicians can respond with a single ion chamber instrument. IF the severity of radiological conditions increases, call the RP Shift Lab, (4282), RP Field Operations Office, (2027) or OSC (4978), for equipment support.
4.4.2 The RP technician(s) shall report to the fire brigade leader at the fire site and provide radiological assistance. This assistance includes assessing airborne activity, radiation levels, contamination control and ensuring everyone has the proper dosimetry. IF the fire involves or potentially involves radioactive material, perform the following:
4.4.2.1 Establish an airborne radioactivity area boundary. Without jeopardizing safety precautions, pull a grab air sample as close as possible to the area where fire fighters will combat the fire. Pull sequential air samples every 30 ft. until a boundary of <.25 DAC (100 ccpm on E-520 setup for cpm) can be established.
A. Perform DAC accounting for all personnel who enter the airborne radioactivity area boundary per HP/0/B/1008/010 (Reference 2.2).
B.
Under situations where an airborne radioactivity area boundary is established, ensure the fire brigade leader and other support personnel move to an area of < 10 DAC (4000 ccpm on E-520 setup for cpm) or utilize appropriate respiratory protection.
C. The only time it is necessary to pull an air sample in "smoke clouds" is outside where burning radioactive material would constitute an effluent release that is NOT monitored or controlled. In this instance pull an air sample downwind of the smoke plume.
D. IF the fire is within the restricted area but outside of buildings that have electrical sockets, other power sources must be located. Inform the fire brigade leader that a portable gas powered generator or an emergency van is needed to provide a power supply for air sampling.
4.4.2.2 Establish radiation levels in the area where firefighters will combat the fire. Determine the following:
HP/O/B/1009/022 Page 8 of 10 A. Do firefighting personnel have sufficient remaining dose to combat the casualty? i.e, will whole body and/or administrative limits be exceeded?
B.
Will extremity dosimetry be necessary?
- 1.
The Radiation Protection Technician shall inform the fire brigade leader if exposure limits may be exceeded, and to do so without the approval described in Radiation Protection Policy Manual Policy Number II-01 (Reference 2.5) will result in a 1 OCFR20 and/or a Tech.
Spec. Violation. Several options are available including, request back up fire brigade members to combat the fire; request verbal approval for extensions over the radio/telephone; assume the responsibility of exceeding such limits; and/or stop fire fighting actions and plan emergency exposures as described in Radiation Protection Policy Manual Policy Number 11-02 (Reference 2.4).
- 2.
IF extremity dosimetry or high range dosimetry will be necessary, continue firefighting actions and request the appropriate dosimetry via the fire brigade leader.
C. Establish an RCZ for radiation levels and contamination in accordance with SH/0/B/2000/005 (Reference 2.6), but far enough back to allow the firefighters to work unencumbered.
4.5 Fires at McGuire outside of the Restricted Area during the day shift.
4.5.1 On the day shift when a fire, or fire drill is announced over the page (or beeper system) at McGuire, any Radiation Protection Technician currently on the fire brigade shall report to the fire brigade assembly area in the truck corridor of the turbine building (outside the Maintenance Shop).
4.6 New Fuel Storage - Inadvertent Criticality Event 4.6.1 Indications of an inadvertent criticality event could occur during the receipt of new fuel or while new fuel is stored in the New Fuel Storage Vault. In either case:
4.6.1.1 The Control Room will contact RP Shift in the event that valid trip 2 alarms are received on either 1EMF20 and/or 1EMF21 (U I New Fuel Storage) or 2EMF7 and/or 2EMF8 (U-2 New Fuel Storage).
HP/OJB/ 1009/022 Page 9 of 10 4.6.1.2 A valid reading could be confirmed by monitoring the OAC for increases on 1EMF20, 1EMF21 or 2EMF7, 2EMF8.
4.6.1.3 During normal working hours, RP Shift shall contact the RP S&C Duty Technician at 2027 or 4847 and relay any applicable information concerning EMF alarm conditions. S&C Technicians should respond immediately to the affected and follow the guidance in Section 4.6.2.
4.6.1.4 RP Shift shall monitor the affected Spent Fuel Building ventilation (1 or 2EMF42) and the affected Unit Vent for increase in activity, as time allows. Follow required sampling procedures should trip 2 conditions on either 1 or 2EMF42 and/or 1 or 2EMF36(L) exist.
4.6.2 RP Technicians responding to the affected Spent Fuel Building shall take the following actions:
4.6.2.1 Obtain appropriate ion chamber and portable neutron detection instruments. RP Technicians covering the receipt of new fuel should have portable neutron detection instruments in their possession. {56}
4.6.2.2 Immediately evacuate all personnel from the affected New Fuel Storage area and Spent Fuel Building. Instruct personnel to use the CAD door emergency egress function to leave the area and report to the Hot Change Room for evaluation. {56}
4.6.2.3 Monitor gamma and neutron dose rates on 760' elevation.
4.6.2.4 Monitor gamma and neutron dose rates on the outside of the New Fuel Storage Vault and the North Yard to the site boundary fence.
Evacuate personnel as necessary.
4.6.2.5 Inform the Operations Shift Manager, or qualified designee, of dose rates encountered in the Spent Fuel Building, the North Yard and at the site boundary fence.
4.6.2.6 Request Security to CAD secure access to the affected area. {56}
4.6.2.7 Post affected areas of the North Yard in accordance with SIVO/B/2000/005 (Reference 2.6).
4.6.2.8 Monitor and evaluate any personnel evacuated from the area for exposure received and internal deposition.
HP/O/B/1 009/022 Page 10 of 10 4.6.3 Do not enter the affected area until a complete assessment of conditions warrants safe re-entry. Follow the guidance in HP/0/B/1009/003 (Reference 2.9).
4.7 Kr-85 Hazard following a Spent Fuel Accident {591 NOTE:
Kr-85 can be a significant radiological skin dose hazard following a spent fuel bundle accident.
4.7.1 Take the following action if a bundle is dropped during movement or if a fuel bundle rupture is suspected:
4.7.1.1 Notify all persons to immediately vacate the area of concern and to proceed to the nearest safe location, taking care NOT to spread contamination unnecessarily.
4.7.1.2 Notify the Operations Shift Manager/designee immediately.
4.7.1.3 Do NOT enter the affected area until a complete assessment of conditions warrants safe re-entry. Follow the guidance in HP/0/B/1009/003 (Reference 2.9). The following are special considerations for re-entry following a spent fuel accident:
A. IF possible before re-entering the area, collect a remote gas sample to determine the concentration of Kr-85.
B. Do NOT use an area radiation monitor to provide an indication that a high concentration of Kr-85 exists. Kr-85 has a low gamma abundance; consequently, an area radiation monitor would be unreliable.
C. Use an RO-2, an RSO-50, or equivalent sealed in a plastic bag with the beta window open to provide a direct Kr-85 dose rate. Be aware that the beta instrument may NOT indicate a high concentration of Kr-85 until the cloud reaches the detector.
- 5. Enclosures 5.1 Commitments for HP/0/B/1009/022
PIP 1-M97-1361 IN 90-08.1 HP/0/B/1009/022 Commitments for HP/O/B/1009/022 Page 1 of 1 Additional procedural guidance concerning Radiation Protection response to inadvertent criticality event.
Kr-85 Hazard from Decayed Fuel. Ensure that specific hazards of Kr-85 are addressed during a spent fuel accident.
{561
{591
(R04-01)
Duke Power Company PROCEDURE PROCESS RECORD (1) ID No. HP/O/B/1009/023 Revision No.
004
-PREPARATION (2) Station (3) Procedure Title McGuire Nuclear Station Environmental Monitoring for Emergency Conditions (4) Prepared By Gary Terrell 2
a
,(
(5) Requires NSD 228 Applicability Determination?
[
Yes (New procedure or revision with major changes)
LI No (Revision with minor changes)
LI No (To in oate rev ioslya ved changes)
(6) Reviewed By L*
,.(QR)
Cross-Disciplinary Review By (QR) NA Reactivity Mgmt. Review By (QR) NA 1
Mgmt. Involvement Review By (OPS Supt.) NA t'*ý"
(7) Additional Rev y
Reviewed By (8) Temporary Approval (if necessary)
By By (9) Approved Byy (OSM)
(QR)
Date January 23, 2002 Date-( Z[
Date
/ Z4O Date-Ifzq Date.
7 1 [I Date /
a-I/
Date Date Date Date 04..-
o6 ---
PERFORMANCE (Compare with Control Copy every 14 calendar days while work is being performed.)
(10) Compared with Control Copy Date Compared with Control Copy Date Compared with Control Copy Date (11) Date(s) Performed Work Order Number (WO#)
COMPLETION (12) Procedure Completion Verification El Yes EL NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?
El Yes El NA Required enclosures attached?
E] Yes EL NA Data sheets attached, completed, dated and signed?
EL Yes El NA Charts, graphs, etc. attached, dated, identified, and marked?
E] Yes EL NA Procedure requirements met?
Verified By Date (13) Procedure Completion Approved Date (14) Remarks (Attach additional pages, if necessary.)
Form based on NSD 703 App D (Procedure Process Record)
Duke Power Company McGuire Nuclear Station Environmental Monitoring for Emergency Conditions Information Use Procedure No.
1HP/0/B/1009/023 Revision No.
004 Electronic Reference No.
MC0095LY
HP/O/B/1009/023 Page 2 of 8 Environmental Monitoring for Emergency Conditions
- 1. Purpose To provide a systematic method for identifying airborne plumes or liquid effluents, and obtaining field data indicative of the radiation exposure to the general public, following a release of radioactive material.
The level of use for this procedure is Information Use.
- 2. References 2.1 HP/0/B/1009/027, Operation of ESP-2 2.2 PT/O/A/4600/088, Functional Check of Emergency Vehicle and Equipment 2.3 SH/O/B/2005/002, Protocol for the Field Monitoring Coordinator During Emergency Conditions
- 3. Limits and Precautions 3.1 During drills/exercises, Field Monitoring Team(s) (FMTs) shall NOT be required to don respirators. This is to assure safe vehicle operation during drill/exercise. During emergency situations respirator use may be required.
3.2 FMT personnel shall be aware of dose and dose rate alarm setpoints on DMC-2000s used in the field. Dose and dose rate alarms are referenced on RWP 98.
3.3 After the use of any Emergency Kit, a full inventory of that kit is required per PT/0/A/4600/88 (Reference 2.2). The checklist in the kit shall be signed and dated each time the kit is inventoried.
- 4. Procedure 4.1 Field Monitoring Team (FMT) Activation and Dispatch 4.1.1 Upon activation of the Emergency Response Organization, report to the OSC.
"* Form two teams to perform initial surveys for plume boundary. IF necessary dispatch additional beta/gamma monitoring teams.
"* Drivers for Field Monitoring Vehicles are provided by C&F. Ensure that each team has a driver prior to leaving the OSC.
HP/O/B/1009/023 Page 3 of 8
"* Personnel NOT trained for emergency response may assist a trained Radiation Protection Technician to do surveys and/or drive emergency vehicles.
"* Communicate team assignment to the OSC RP Supervisor, or qualified designee.
4.1.2 In the OSC, use any issued pocket dosimeter until DMC-2000s have been obtained. Leave pocket dosimeters in the supply cabinets upon dispatch.
Return PD's to the OSC upon returning to the site.
4.1.3 The OSC RP Supervisor, or qualified designee, shall brief at least one member of each FMT on current plant conditions (plant status, release in progress, emergency classification).
4.1.4 Following the plant status brief from the OSC RP Supervisor, obtain current meteorological data using the guidance in Enclosure 5.11.
4.1.5 WHEN directed, make preparations for dispatch by completing pre-dispatch portion of Enclosure 5.1 (Sample Van) or Enclosure 5.2 (Survey Vehicle).
- The Radiation Protection Manager can elect to dispatch FMT's at his/her discretion.
4.1.6 Follow FMC direction concerning protective dress requirements according to existing conditions per RWP-98.
4.2 Field Monitoring Team (FMT) Communications 4.2.1 Maintain open radio communications with the FMC. IF the radio becomes inoperable, telephone:
TSC Dose Assessment 875-4976 FMC at EOF (704) 382-0735/0736 RP Sample Van 1 (cellular phone) 534-1563 RP Sample Van 2 (cellular phone) 534-1564 4.2.2 Provide pertinent, general information. DO NOT provide detailed, specific plant information.
4.2.3 During a drill, repeat the statement, "This is a drill", or, "This is'an exercise message," with each radio transmission using the proper radio call signs (Base - WQC700, Mobile -KA82138).
HP/O/B/1009/023 Page 4 of 8 4.2.3.1 The Base Station must give the radio call sign with each transmission.
4.2.3.2 The field teams do NOT have to use the radio call sign when addressing the Base Station. The field teams must give the radio call sign when addressing other field teams.
4.2.3.3 For any backup sampling vans from other stations, the call sign shall be preceded by the station name (example "Oconee sample van 1 ").
4.2.3.4 Vehicles drawn from the McGuire garage that are designated as beta/gamma survey teams shall use 'alpha, bravo, charlie, and delta' designations during radio messages.
4.2.3.5 WHEN transmitting vital information, use repeat back method of communications and the phonetic alphabet.
4.2.3.6 Follow FCC guidelines for radio communications at all times.
4.3 Locating and Tracking the Plume 4.3.1 Begin plume boundary identification by monitoring dose rates while traversing east and west of the site (= 0.5 miles), traveling on owner controlled roads only.
4.3.1.1 East of site - travel from the Hwy. 73 (stoplight) entrance to the MOC to the end of the discharge canal fishing area.
4.3.1.2 West of site - travel from the medical facility parking lot to approximately the lower level intake using the road by the Initial Holdup Pond.
4.3.1.3 Communicate location to the TSC and/or EOF when plume edge is identified. Any change in background dose rate shall be assumed to indicate plume edge. Communicate changes in dose or count rates immediately.
4.3.1.4 DO NOT enter the plume unless directed by the FMC.
4.3.2 Be prepared to take full direction from the Field Monitoring Coordinator (FMC) at the EOF, when that position is prepared to do so.
HP/O/B/l 009/023 Page 5 of 8 4.3.2.1 Major roadways delineate major territories surrounding the plant.
Either all or a portion of these sections would be expected to be affected to some degree by radioactivity released from the plant.
Utilize major roadways to access suspected regions (outer edges, leading edge(s), centerline) of the plume, as necessary.
A. Major roadways on the EPZ map are identified by numerical designations and responsibility level (federal, state, county or city) designations.
B.
Selected roadways on the EPZ map are identified by a specific name, rather than a numerical responsibility designation.
4.3.2.2 Each predetermined sampling location is denoted by a red text oval on the map. The sampling point designator indicates the protective action zone the point is in and the mileage from the plant.
A. The FMC should use the points as landmarks when directing the teams.
B.
The point locations can be read directly from the map or from the directions in Enclosure 5.6.
4.3.2.3 While enroute and at sampling locations, report the maximum radiation level, and location of plume boundaries to the FMC.
4.3.2.4 Record radiation dose rates and sample results on Enclosure 5.7.
4.3.2.5 Once a release has occurred, close vehicle windows and place ventilation off or on recirculation to minimize contamination until the plume area is identified.
4.3.2.6 Ensure that count rate meter is on and is monitored during transport to sampling locations.
4.3.2.7 IF any equipment becomes inoperable, notify the FMC and await further instructions.
4.3.2.8 Record plant status update information on Enclosure 5.8.
4.3.2.9 Verify worker classification changes on RWP with changes in plant conditions.
HP/O/B/1009/023 Page 6 of 8 4.3.2.10 Record any or no exposure received and turn in dosecards upon returning to site. Submit dosecards as record for all drills and exercises.
CAUTION:
Park vehicles completely off the road when sampling and use emergency flashers and the strobe while stopped.
Wear reflective vests when leaving a vehicle parked on the roadside for sampling.
Vests are stored in the rear section cabinet with protective clothing.
4.4 WHEN directed, collect additional environmental samples, including but NOT limited to: air samples, smears of surrounding areas, integrated dose over a period of time with TLDs, vegetation, sediment, water, and milk, as requested by the FMC. Label and save each for analysis. FMTs may also be requested to retrieve and replace environmental air samplers and/or TLDs.
4.4.1 To collect a vegetation sample, use the shears to cut enough broad leaf vegetation to fill a 12"x 12" poly bag.
4.4.2 To collect a soil sample, estimate one square foot of soil and dig out one inch deep.
4.4.3 To collect a water sample, fill a one gallon cubitainer. For differences in elevation, or samples that are difficult to obtain, use the limnological sampling equipment (see Enclosure 5.3).
4.4.4 To perform a contamination survey, take smears on stationary, horizontal surfaces, e.g. mailboxes, gas pumps, etc., DO NOT perform contamination surveys on automobiles!
4.4.5 To collect an air sample:
NOTE:
Be aware of terrain during air sampling or surveying (i.e. windbreaks formed by landscape or vegetation) which could inhibit acquiring representative samples.
4.4.5.1 Position sample van air sampling port in the direction of the plant.
4.4.5.2 Load Particulate and Charcoal (P&C) cartridge into P&C holder.
4.4.5.3 Remove the cover from the air sampling port.
4.4.5.4 Insert P&C holder into the sample port to ensure outside air is sampled.
HP/O/B/1009/023 Page 7 of 8 4.4.5.5 Start air sampler and run for required time. (Normal air sample is 5 minutes at 2 CFM).
4.4.5.6 Stop the air sampler.
4.4.5.7 Remove P&C holder from the air sampling port.
4.4.5.8 Replace cover on air sample port.
4.4.5.9 Move van to a low background area.
4.4.5.10 WHEN van is no longer in the plume, purge the P&C by permitting 15 ft 3 of air to flow through the sample cartridge. (7.5 minutes @ 2 cfm) 4.4.5.11 Remove the P&C from the P&C holder.
4.4.5.12 Separate the P&C.
4.4.5.13 Label particulate and charcoal and retain the particulate filter for gamma spec analysis.
4.4.5.14 Count the air sample charcoal cartridge, document and report results using Reference 2.1.
4.4.5.15 Retain the charcoal cartridge for further analysis.
4.5 FMT Turnover 4.5.1 FMTs shall be relieved as directed by the FMC.
4.5.2 Provide turnover to the relief FMTs, using Enclosure 5.10.
4.5.3 Turn in all data sheets to the FMC as directed.
4.5.4 After being relieved, report to a counting facility designated by the FMC for a post-job BBA.
- 5. Enclosures 5.1 Sample Van FMC Checklist 5.2 Survey Vehicle FMT Checklist 5.3 List of Designated Limnological Sample Points 5.4 Detailed Guide to All TLD Sample Locations
HP/O/B/1009/023 Page 8 of 8 5.5 List of Designated Milk Sample Locations 5.6 Directions for Predetermined Survey/Sampling Locations 5.7 Field Monitoring Survey Data Sheet 5.8 Periodic Status Update for Field Monitoring Teams 5.9 Vehicle Refueling 5.10 FMT Turnover Checklist 5.11 Obtaining Meteorological Data from SDS
.1 HP/O/B/1009/023 SAMPLE VAN FMT CHECKLIST Page 1 of 2 PRE-DISPATCH El Ensure that current plant status and meteorological information has been obtained.
El Obtain Emergency key set (#905 and 906) from Security at the PAP. Proceed to the equipment storage area (Room 158 of the Administration Building) and unlock the equipment storage locker.
El Obtain the following equipment: Normal issue TLD, electronic dosimeter (DMC-2000) and a dose card. Sign in on RWP-98. Ensure the DMC-2000 is on and has been re-zeroed. ED alarm setpoints are 50 mR/hr (dose rate) and 15 millirem (accumulated dose). ED's are reset by placing in the manual reader provided.
El Obtain portable instruments (ion chamber and count rate meters) and source check. Survey the area for radiation levels.
El Remove portable radios from chargers (one unit for each FMT). Screw in the antenna to the top of the radio. Turn the off/on/volume control switch on the top of the radio until SELF TEST is displayed on the front. IF MCGUIRE C17 does NOT display after SELF TEST, turn the numbered switch on the top of the radio to position 3 and lock with the locking ring. Ensure that the small toggle switch is set to position "A".
"El Test the radios using the mobile call sign: "WQC 700, McGuire Base, this is KA8-2138, portable radio check. Do you copy?" IF McGuire Base does NOT respond, perform radio checks with the other sample van using the mobile call sign "KA8-2138, Sample Van (other sample van), this is Sample Van __
(your sample van) portable radio check. Do you copy?"
IF a radio does NOT function, remove it from service by removing the battery. Ensure that the radio is turned off before removing or replacing any battery.
"El Obtain all other necessary equipment: respirators, ESP-2's and check sources. Obtain canvas bags ESK-1 or ESK-2 (sample van kits). They can be used to carry instruments and respirators. All protective clothing is located in the back cabinet of the sample vans.
"El One team shall call the TSC Dose Assessor at 875-4976 to determine the status of any release and communicate this information to the other teams.
El Proceed to the sample vans monitoring portable instruments in transit. Start sample van engines and stabilize inside temperature.
"El Turn on the sample van radio. The unit will display SELF CHECK and MCGUIRE in sequence.
IF MCGUIRE is NOT displayed after SELF CHECK, press the MODE key until MCGUIRE is displayed.
"El Test the radios using the mobile call sign: "WQC 700, McGuire Base, this is KA8-2138, sample van 1 (or 2). Do you copy?" "IF McGuire Base does NOT respond, perform radio check with the other sample van using the mobile call sign: "KA8-2138 Sample Van (other sample van), this is Sample Van (your van). Do you copy?"
.1 HP/0/B/1009/023 SAMPLE VAN FMT CHECKLIST Page 2 of 2 El Turn on the cellular phone. Unlock the phone for use by pressing the last three (3) numbers of the cell phone number. Test the phone by calling TSC dose assessment at 875-4976. It may be necessary to move the vans from under the unit high voltage lines to test the cellular phones.
El Start the power inverter (located behind the left side of the driver's seat) to the ON position. The air sampler and plug mold strip are now energized. The air sampler is located on the left side arm rest, back seat.
El Set up ESP-2's. Perform background and source checks in accordance with HP/0/B/1009/027.
Sample vans should perform background and source checks while the van is stationary. Report any problems to the TSC/EOF.
El Notify TSC Dose Assessors that pre-dispatch checks are complete and: (circle one)
- a. Sample Van (1,2) is proceeding west of the plant to traverse from Medical Facility parking lot to approximately the lower level intake using the road by the initial holdup pond.
- b. Sample Van (1,2) is proceeding east of the plant to traverse from Hwy 73 (stop light) entrance to the MOC to the end of the discharge canal fishing area.
- c. Sample Van (1,2) is standing by at (location).
UPON RETURNING TO THE SITE:
El Ensure mobile van radios are switched off.
"El Ensure that power inverter is turned to the OFF position.
"El Perform inventory of protective clothing and emergency equipment per PT/O/A/4600/88.
(Notify the RP Staff Scientist of any discrepancies.)
El Turn off all instruments and portable radios and place in storage cabinet.
"El Remove portable radio antennas and place radio into a charging unit.
"El Ensure that ED's display the calibration date and place in storage cabinet..
"El Ensure that storage cabinet is closed and locked.
"El Turn in all relevant surveys and checklists.
El Turn in dosecards to DRC.
El Return keys to Security at the PAP.
.2 HP/O/B/1009/023 SURVEY VEHICLE FMT CHECKLIST Page 1 of 2 PRE-DISPATCH El Ensure that current plant status and meteorological information has been obtained.
El Obtain Emergency key set (#905 and 906) from Security at the South PAP. Proceed to the equipment storage area (Room 158 of the Administration Building) and unlock the equipment storage locker.
El Obtain the following equipment: a normal issue TLD, electronic dosimeter (DMC-2000) and a dose card. Sign in on RWP-98. Ensure the DMC-2000 is on and has been re-zeroed. ED alarm setpoints are 50 mRlhr (dose rate) and 15 millirem (accumulated dose). ED's are reset by placing in the manual reader provided.
El Obtain portable instruments (ion chamber and count rate meters) and source check. Survey the area for radiation levels.
El Remove portable radios from chargers (one unit for each FMT). Screw in the antenna to the top of the radio. Turn the off/on/volume control switch on the top of the radio until SELF TEST is displayed on the front. IF MCGUIRE C17 does NOT display after SELF TEST, turn the numbered switch on the top of the radio to position 3 and lock with the locking ring. Ensure that the small toggle switch is set to position "A".
El Test the radios using the mobile call sign: "WQC 700, McGuire Base, this is KA8-2138, portable radio check. Do you copy?" IF McGuire Base does NOT respond, perform radio check with one of the sample vans using the mobile call sign:
"KA8-2138, Sample Van __
(1 or 2), this is a portable radio check. "Do you copy?"
IF a radio does NOT function, remove it from service by removing the battery. Ensure that the radio is turned off before removing or replacing any battery.
El Obtain the designated emergency kits ESK-3 or ESK-4 (canvas bags) from the locker. All other necessary equipment is located in the kits.
El Proceed to the McGuire Garage by personal vehicle or Sample Van. IF obtaining pool vehicles after hours, weekends or holidays, call Security from the Garage gate phone to gain access. The phone number is located on the phone housing.
.2 HP/0IB/1009/023 SURVEY VEHICLE FMT CHECKLIST Page 2 of 2 0
Notify the TSC Dose Assessor that pre-dispatch checks are complete and; (circle one)
- a. Survey Vehicle (alpha, bravo, charlie, delta) is proceeding west of the plant to traverse from Medical Facility parking lot to approximately the lower level intake using the road by the initial holdup pond.
- b. Survey Vehicle (alpha, bravo, charlie, delta) is proceeding east of the plant to traverse from Hwy 73 (stop light) entrance to the MOC to the end of the discharge canal fishing area.
- c. Survey Vehicle (alpha, bravo, charlie, delta) is standing by at (location)
UPON RETURNING TO THE SITE:
o Perform inventory of emergency equipment per PT/O/A/4600/88 (Reference 2.2).
Notify the RP Staff Scientist of any discrepancies.
o Turn off all instruments and portable radios and place in storage cabinet.
0 Remove portable radio antennas and place radio into charging unit.
El Ensure that ED's display the calibration data and place in storage cabinet.
0 Ensure that storage cabinet is closed and locked.
0 Turn in all relevant surveys and checklists.
El Turn in dosecards to DRC.
El Return emergency key set to Security.
I
.3 HP/O/B/1009/023 List of Designated Limnological Sample Points Page 1 of 1 Mt Holly Intakes - Sector E (South - 5 miles)
Sample elevation - 630' Accessible on Hwy 273, north of Duke Power Mt. Holly Training Center.
Charlotte Intakes - Sector E (South) 5-6 miles Sample elevation 635'- Unit 1 intake 640 - Unit 2 intake 637'- Unit 3 intake Accessible by land on SR 2004 (Mt. Holly-Huntersville Road)(Pump Station Road)
LIMINOLOGICAL SAMPLING DIRECTIONS (1) Pull one of the blue stoppers out of the end of the main tube and attach the wire loop to one of the small pins on the handle tripping mechanism.
(2) Repeat for the other stopper.
(3) Lower the bottle under water keeping the line taut, and drop the weight to strike the tripping mechanism. This will release the cables and close the bottle.
(4) For shoreline sampling when the elevation difference is small, attach one stopper and fill the bottle with water by scooping. The bottle can now be closed and the black nozzle used to empty the sample into a cubitainer.
NOTE:
- 1. Full lake elevation is 760"
- 2. Catawba River spillway elevation (for Charlotte intakes) is 647'6"
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 1 of 7 This enclosure is meant to provide a guide to one who is NOT familiar with the environmental TLD sample route. Appropriate deviations from this sequence and route may be made as necessary.
A. Sample location numbers:
143 -
Point of land north of intake pumps.
144 -
On the fence, at air sampling site #120, near E.P. Boat House.
145 -
On the fence, at air sampling site #121, near guard house at Training and Technology Center.
146 -
Shoreline of discharge canal, below the bridge.
147 -
On the fence, at the Training and Technology Center, Environmental Laboratory, behind the QA building, next to the beige aluminum building.
148 -
Second utility pole on the right-hand side of Energy Explorium Entrance from Hwy. 73.
149 -
Near site fence, 200 feet east of U-2 Access Road on Hwy. 73.
151 -
Fence east side inside O.C. (Owner Controlled) Gate #2.
152 -
Near railroad tracks west of McGuire main entrance.
153 -
Clearing on the left, inside O.C. (Owner Controlled) Gate #4 (S. River Gate).
154 -
Edge of river bank, access O.C. (Owner Controlled) Gate #5 (Lower Dam Access).
156 -
Top of earthen dam, access O.C. (Owner Controlled) Gate #7.
157 -
Williamson access area (on the Mecklenburg Neck) on utility pole just beyond access sign.
158 -
End of state maintained Road #2189 (Bethel Church Road).
159 -
Anchorage Marine Shipyard at Holiday Harbor Marina.
160 -
On the fence, at Anchorage Marine Showroom.
161 -
Main power pole at the intersection of Hwy. 21 and Hwy. 73.
162 -
First power pole at the intersection of Gilead Road and State Road #2139.
163 -
At the intersection of Hambright Road and McCoy Road (State Road #2138).
164 -
Power pole at the intersection of Beatties Ford Road and Hambright Road.
165 -
Approximately 2 miles down power plant road from River Bend Steam Station.
166 167 168 169 170 171 172 173 174 175 177 178 180 181 182 186 187 191 196 197 198 199 -.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 2 of 7 Water tank across from River Bend Steam Station.
Behind Lucia Volunteer Fire Department.
Power pole at State Road #1511 at Killian Creek.
Last power pole on Kincaid Road.
Second utility pole on right from intersection of Hwy. #73 and State Road #1386.
Utility pole at Triangle Hardware.
Power pole at the residence located at 625 Golf course Ln.
First utility pole on S.R. #1891 intersection with S.R. #2393.
On the fence, at air sampling site #134, near East Lincoln Junior High School.
Utility pole, fifth house on right, Hoyle Road.
On a tree at the residence, 908 Belmarrow Dr.
Duke Power Substation at AmeriSteel Corporation.
Mooresville Water Treatment Plant.
Davidson Water Treatment Plant.
On the fence, at air sampling site #133, at Cornelius substation.
On peninsula beyond MNS fishing access.
First gravel road past Energy Explorium.
Fenced pumping station on John Connor Dr.
New Landfarm fence.
New Landfill fence.
Old Landfill fence.
Old Landfill fence at groundwater well MW-i.
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 3 of 7 B. Directions to sampling locations:
NOTE:
Contact Security at Ext. 4460 to open all O.C. (Owner Controlled) Gates.
Site #144 Located inside the air sampling cage by the HP Boathouse (air site #120)
Site #187 Continue past Energy Explorium and take first right on to a gravel road. The TLD is located inside air sampler cage (air site #195).
Site #186 Proceed toward the Plant to the end of the fishing access. Bear to the right at the site boundary fence, unlock the cable and proceed out on the peninsula. The TLD is on a stake about half way out the peninsula to the right on a stake.
Site #143 Continue out the peninsula to the point where the TLD is located on a stake near the osprey nest site.
Site #145 Heading back toward the guardhouse, the TLD is located inside the cage at the air sampling site #121.
Site #146 Passing the guardhouse on your left, the TLD is located on the left, attached to the backside of the light pole, just after crossing the bridge.
Site #147 Continue forward to main entrance road. Turn into the QA entrance on your left. The TLD is on the chainlink fence beside the brown aluminum building. (A large oak tree is in front of the fence).
Site #148 Continue down entrance road to the fourth light pole on the left. The TLD is on the backside of the utility pole. You 1l have to pull over to the right off of the road and allow the other person to pick up the TLD on the left side of the road.
Site #149 Continue on to the stop sign at Hwy 73. Turn right and go to the first clearing on the right. The TLD is located on the site boundary fence.
Site #189 Continue forward on Hwy 73 toward MNS. The TLD is located just off the right side of the road on a stake near a tree with a red painted dot just before transmission lines cross Highway 73.
Site #152 Continue past MNS main entrance for approximately 100 yards to the clearing on your right. The TLD is located between on a stake..
Site #151 Enter MNS main entrance. The TLD is located on the fence by OC gate #2 immediately on the right.
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 4 of 7 Site #153 Continue into MNS and head toward the setting ponds/land farm area. Circle around the settling ponds and pass the air site (#125) on the left. Proceed to OC gate #4 and approximately 100 feet from the gate is a clearing on the left. The TLD is located on a stake in the clearing.
Site #154 Drive vehicle back around setting ponds toward the land farm area and turn left on the first gravel road and proceed through QC gate #5. Drive to where the road forks. Take the left fork and down the next gravel/dirt road on your right, you may drive directly to the level grassy area near the riverbank edge. The TLD is on a stake near the riverbank edge approximately 3/4 of the way down the length of the rocky bank just past the control monument.
Site #190 Continue along the riverbank follow the tree line away from the river until you see a "dangerous water" sign. Continue forwards approximately 300 yards to the tree with a painted red dot on it. The TLD is on a stake.
Site #156 Drive the vehicle back up the hill toward warehouse #5. Make a left turn just before you get to warehouse #5 and go up toward the intake structures. The road heads toward MNS and then makes a hairpin turn back toward the dam. Drive all the way to the edge of Cowan's Ford Dam and the TLD is located to the left of the cement wall on a stake.
Site #196 Return to Hwy 73 and turn left. Turn right at MNS Garage Access Road and proceed past garage to dirt road on the right. Drive down dirt road past electrical switch yard to the MNS landfarm on the left. The landfarm is fenced in and the TLD is on the fence adjacent to the road. NOTE: TLD #196 replaces old TLD #LF2.
Site #197 Proceed down dirt road to the landfill. The TLD is located to the left of the gate to the landfill.
Site #198 Proceed back toward garage and take dirt road to left. Drive to road ends at old landfill gate. TLD is at top of hill to the right of the gate.
Site #199 Drive through gate to back side of the landfill. You will see a groundwater well (MW
- 1) near the back gate. The TLD is at MW-I on a steel post.
Site #191 Return to Hwy 73 and turn right. Drive toward Cornelius and take a left on Jetton Rd.
Drive to John Connor Rd. and take a left onto it. Drive a short distance to the CMUD pumping station on the left. The TLD is on the air sampler environmental house inside the fenced pumping station (air site # 192).
Site #158 Return to Hwy 73 and turn left. Proceed to Bethel Church Rd. (SR 2189) and turn left.
Proceed to Staghorn Rd. The TLD is located on a utility pole at the intersection of Bethel Church Road and Staghorn Road.
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 5 of 7 Site #159 Return to Hwy 73. Turn left and make a sharp left turn onto Henderson Rd. Drive to the end of that road. The TLD is on the oak "NRC Tree" by the water.
Site #160 Return to Hwy 73 and turn left. Follow 73 east to Hwy 21 South, turn right and go to the Anchorage Marine Showroom, which will be on the left. The TLD is located on the chain link fence in front of the parking lot.
Site #161 Return to Hwy 73 and turn left. Continue to the intersection of 21 and Sam Furr Rd.
The TLD is located on the back of the Energy Explorium sign to the right.
Site #178 Continue on Hwy. 21 (heading south) and go until you intersect with Gilead Road.
Turn left onto Gilead Road. Proceed to the intersection of Gilead and Old Statesville Road (Hwy. 115) and turn right. Keep going past North Mecklenburg High School and continue to the "Croft Community" sign (which will be on your right). Immediately after this sign on your right is a dirt road. Turn right and this is the entrance to the Duke Power substation @ Florida Steel Corp. Use a DPC #2 key to gain access down the road. The TLD is on a stake to the left of the road approximately 100 yards past the entrance gate.
Site #163 Return to Hwy.1 15. and turn left, proceed to SR #2117 (Hambright Road). Turn left (directly in front of Alexander Jr. High School) and proceed to McCoy Rd. (-3.0 miles). The TLD is located on the telephone pole (beside the NRC TLD) at the residence.
Site #164 Turn around on McCoy Rd. then turn right on Hambright Rd. Come to the intersection of Hambright and Beatties Ford Road. The TLD is located on the left side of the road on a telephone pole.
Site #162 Turn right onto Beatties Ford Rd. and proceed to Bud Henderson Rd., turn right. Go to Gilead Rd. and turn right. Proceed to Ranson Rd. (SR #2139, this road is in a sharp curve) and turn left. TLD is on the second pole on the left near an electric fence.
Site #182 Return to Gilead Rd. and turn left. Travel forward over 1-77. Turn left onto Old Statesville Road and go to Cornelius. TLD is inside cage at air sampler site #133.
Site #181 Travel on to Davidson water treatment plant. The TLD is on a power pole in the front of the plant.
Site #157 From Davidson water treatment plant, go to stop sign and turn left onto Gamble St. Go one block and turn right onto Jetton St. Follow until road ends, turn left and you will see 1-77 to your right. Take 1-77 North to exit 33, Hwy. 21N. Turn left. Proceed until you come to Brawley School Rd. (there will be a church on your right just before the intersection where you will be turning left.) Follow Brawley School Rd. which eventually turns into Mayhew Rd. past Mallard Head Country Club until the road dead ends (- 8 mi.). The TLD is located on a utility pole in the right rear yard.
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 6 of 7 Site #180 Go back to intersection of Brawley School Rd. and Hwy 21. Cross straight over 21 towards Mooresville. At Hwy 21N, turn left and continue to Mooresville water treatment plant. The TLD is located on a utility pole to the right of the driveway.
Site #173 Return to Hwy 21-South and turn right. Proceed approximately 1/2 mile and veer to your right to Hwy. 150 west. Proceed past Marshall Station to the intersection of SR 1899 and 150 and turn left. This will be SR 1899 Slanting Bridge Rd. Continue to Keistler's Store Rd. and turn left. Follow this road to Mountain Shore Lane, turn left (across from the two-story beige house). Next turn left onto Glenwood Rd. The TLD is located on the first power pole in the front yard of the first house on the left.
Site #172 Return to Slanting Bridge Rd. Turn left and continue to Hwy. 16. Turn left and go to Fairfield Rd. (-3.3 miles) on the left in the Westport Community and turn left (SR 1389). Take the first left onto North Golf Course drive which turns into Lakeshore Drive. At the intersection of Golf Course Drive and Lakeshore Drive. The TLD is on the utility pole to the right @ 625 Golf Course Dr.
Site #171 Return to Hwy 16-South, turn left. TLD is on the utility pole on the north side of the Triangle Ace Hardware (which will be on the left).
Site #170 Return to Hwy. 16 and turn left. Proceed to the intersection of Hwy. 16 and 73. Turn right onto 73 and turn left onto Little Egypt Rd. The TLD is on the 2nd utility pole on the right.
Site #174 Return to Hwy. 73 and turn left. Go to East Lincoln Jr. High School. The TLD is located in the air sampling cage at air sampling site #134.
Site #175 Return to Hwy. 73 and turn right. Go to Boger City. Hwy. 73 runs into Hwy. 27. Go straight to the first light and turn right on to Buffalo Shoals Rd. Proceed until you come to SR 1332 (Highland Rd.) and turn left. Follow to Hoyle Road on your right and turn right. Go to 208 Hoyle Road. TLD is on the fence beside the house.
Site #168 Return to Hwy. 73 and go back past East Lincoln Jr. High School, take a right on Old Plank Road. Go approximately 5 miles until you cross a bridge. The TLD is located on a utility pole on the right just after crossing the bridge.
Site #177 Return to Hwy 73 and continue to stop light at Hwy. 16. Turn right on to Hwy 16 and proceed to Rozzelles Ferry Road (old Hwy.16) and take a right. Rozzelles Ferry turns into Belhaven Blvd. Go to a green Coulwood School sign. Turn right at this sign.
This is Kentberry Rd. Continue - one block and turn left onto Belmarrow Dr. The TLD is located @ 908 Belmarrow Rd. on a safety light pole at the driveway entrance to the left.
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 7 of 7 Site #166 Return to Hwy. 16 and turn right. Continue to the Catawba River. After crossing the bridge, turn right at Steam Plant Rd. and follow this road to Riverbend Steam Station.
Continue on Horseshoe Bend Beach Rd. to the water tower that is across the road directly in front of the steam station. The TLD is on the fence which surrounds the water tower.
Site #165 Continue down the road, away from Hwy. 16, - 1 mile to a real sharp curve in the road. There'll be a dirt area on your left where you can pull over at a barricade. The TLD is on utility pole to the left of the barricade.
Site #167 Return to Hwy. 16. At the light, go straight and proceed to the building at 14522 Lucia Riverbend Highway on the right. The TLD is located on a power pole that supplies the building.
Site #169 Return to Hwy. 16 and turn left. Proceed to Hill's Chapel United Methodist Church on the left. Just past the church is a dirt road (Glover Lane), turn left and go to the end of this road. The TLD is located on a utility pole on the right.
.5 List of Designated Milk Sample Locations HP/O/B/1009/023 Page 1 of 1 This enclosure is meant to provide a guide to one who is NOT familiar with the environmental milk sample route. Appropriate deviations from this sequence and route may be made as necessary.
MILK SAMPLES A. Sample location numbers:
139 - William Cook Dairy 138 - Henry Cook Dairy 140 - David Kidd Dairy 141 - Lynch Dairy B. Directions to sampling locations:
Location #139 William Cook Dairy Location #138 Henry Cook Dairy Location #140 Kidd's Dairy Location 141 Lynch Dair Turn left when leaving MNS main entrance and proceed to Oliver Hager Rd. (SR #2142) on your right. Follow road to the large main house. Behind the house is a garage storage area. The milk will be in a refrigerator in the garage area.
Return to Hwy. 73 and turn left. Proceed to Beatties Ford Rd.
(Rd. beside Phillips 73 General Store) and turn left. Follow Beatties Ford Rd. approximately.5 miles to Gilead Rd. Turn left. Follow Gilead Rd. approximately 4 mi. to Ervin Cook Rd. Turn left. Henry Cooks Dairy will be the second dairy on your left, approx. 1 mi. It will be on your left just before the road ends. The milk will be in a refrigerator in the white wooden building on your right.
Return to Beatties Ford Road and make a left.
Proceed to Jim Kidd Road (approximately 1.0 miles) and turn right.
Proceed approximately.5 of a mile and look for a white house on the right. Follow the dirt road to the rear of the house. The milk sample is taken from the vat located in the block building behind the house.
From ASC turn right onto Hwy. 73. Follow Hwy. 73 until it intersects with Hwy. 27. Follow Hwy. 27 into Boger City to SR
- 1003 (Buffalo Shoals Road) and turn right. The Lynch residence is 5.4 miles on the right (yellow frame house).
.6 HP/O/B/1009/023 Directions for Predetermined Page 1 of 10 Survey/Sampling Locations Example:
A 2
1 Evacuation Mile Sample Zone Radius A-2-1 From the intersection of Hwy. 73 and Jetton Road (SR215 1), go west on Jetton Road 2.0 miles. Turn left onto John Connor Rd. and go 1.0 miles. Turn right on Belle Isle Dr. (SR2331) and go to the end of the road.
A-3-1 From the intersection of Hwy. 73 and Jetton Road (SR215 1), go west on Jetton 3.8 miles to dead end.
A-3-2 From the intersection of Hwy. 73 and Jetton Road (SR215 1), go west on Jetton Road 2.1 miles to the intersection of Jetton Road and North Beatties Ford Rd. Go to end of road and turn right.
A-3-3 From the intersection of Hwy. 73 and Nantz Road (SR2148), go west on Nantz Road. Go to end of Nantz Road.
A-5-1 Take 1-77 north to exit 33, turn left on Williamson Road (SRI 109). Turn left on Brawley School Road (SRi 100), go west 8.0 miles on Brawley School Road to dead end at water.
NOTE: Brawley School Road becomes Mayhew Road at Meckenburg County Line.
A-5-2 From the intersection of Hwy. 73 and Bethel Church Road (SR2189), go north on Bethel Chuch Road to the end of Bethel Church Road.
A-5-3 From the main plant entrance, go east on Hwy. 73 (6.4 miles) to the intersection of Hwy. 73 and Henderson Road (SR2307).
A-6-1 From the intersection of Williamson Road (SRI 109) and Brawley School Road (SRi 109),
go west 6.9 miles on Brawley School Road. Turn left on Tortence Chappel Road (SR2065),
go 0.4 miles. Stop on roadside. NOTE: Brawley School Road becomes Mayhew Road at Mecklenburg County Line. Torrence Chappel Road is the first left after the county line.
B-1-1 One mile from plant on Lake Norman. (WNW)
B-l-2 One mile from plant on Lake Norman. (NW)
B-1-3 One mile from plant on Lake Norman. (NNW)
B-l-4 One mile from plant on Lake Norman. (N)
B-l-5 One mile from plant on Lake Norman. (NNE)
B-l-6 Emergency Boat House and dock.
One and 1/2 miles from plant on Lake Norman directly east of TTC. (NE)
B-1-7
.6 HP/O/B/1009/023 Directions for Predetermined Page 2 of 10 Survey/Sampling Locations B-1-8 One and 11/4 miles from plant on Lake Norman (NE) at mouth of discharge canal.
B-1-9 One and 1/2 miles from plant on Lake Norman (ENE).
B-1-10 Bridge over discharge canal on road to TTC.
B-1-11 The intersection of U-2 access road and the road to TTC.
B-1-12 On the roadside of U-2 access road.2 miles off of Hwy. 73.
B-1-13 The intersection of Hwy. 73 and the U-2 access road.
B-1-14 The intersection of Hwy. 73 and the access road to the firing range.
B-1-15 U-I main entrance.
B-1-16 Right past the bridge on Hwy. 73 over the Catawba River (below the dam).
B-1-17 The east side of Cowans Ford Dam, access through O.C. Gate #5 (lower dam access).
B-1-18 At the intake structure.
B-2-1 2 miles from plant on Lake Norman (NE).
B-2-2 From McGuire main entrance, go east on Hwy. 73 (2.5 miles). Turn left on Terry Lane (SR2255). Go 0.5 miles to the end of Terry Lane (SR2255).
B-3-1 From McGuire main entrance, go east on Hwy. 73 (3.8 miles). Turn left on Norman Island Drive (SR2145). Go to the end of of Norman Island Drive.
C-1-1 At the intersection of Hubbard Road and Hwy. 73 turn on Hubbard Road (SR2134) and stop on roadside.
C-1-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south 1.3 miles on Beatties Ford Road. Turn right onto Cashion Road (SR2133), go to end of road.
C-2-1 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south 1.3 miles on Beatties Ford Road to the intersection of Beatties Ford Road and Cashion Road (SR2133).
C-2-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south 1.5 miles on Beatties Ford Road. Turn right on Stephens Road (SR2132), go.7 miles to dead end at gate.
D-2-1 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south.3 miles on Beatties Ford Road to the intersection of Beatties Ford Road and Gilead Road (SR2136).
.6 HP/O/B/1009/023 Directions for Predetermined Page 3 of 10 Survey/Sampling Locations D-3-1 From McGuire main entrance go east on Hwy. 73 (3.8 miles) to first stoplight. Cashion's convenience store parking lot on Hwy. 73.
D-3-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go.3 miles south on Beatties Ford Road. Turn left on Gilead Road (SR2136), go 1.2 miles to the intersection of Gilead Road and Bud Henderson Road (SR213 1).
D-3-3 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 2.4 miles to the intersection of Beatties Ford Road and Jim Kidd Road (SR2129).
D-3-4 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 3.5 miles. Turn right on Neck Road (SR2074), go 2.4 miles to the intersection of Neck Road and Allison Ferry Road (SR2127).
D-3-5 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 3.5 miles. Turn right on Neck Road (SR2074), go 2.4 miles. Turn right on Allison Ferry Road (SR2127), go.7 miles to dead end.
D-5-1 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road.3 miles. Turn left on Gilead Road (SR2136), go 3.0 miles to the intersection of Gilead Road and Ranson Road (SR2139).
D-5-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 4.2 miles. Turn left on Hambright Road (SR2117), go 1.6 miles to the intersection of Hambright Road and McCoy Road (SR2120).
D-5-3 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 4.2 miles to the intersection of Beatties Ford Road and Hambright Toad (SR2117).
D-5-4 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 5.0 miles to the intersection of Beatties Ford Road and Sample Road (SR2125).
D-5-5 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 3.5 miles. Turn right on Neck Road (SR2074), go 2.4 miles. Bear to left and continue 0.6 miles. Stop on roadside. Should see entrance to Cowan's Ford Waterfowl Refuge.
E-6-1 From the intersection of Beatties Ford Road (SR2128) and Mt. Holly Huntersville Road (SR2004), go west on Mt. Holly-Huntersville Road to the intersection of Mt.
Holly-Huntersville Road and Oakdale Road (SR2042).
E-7-1 From the intersection of Beatties Ford Road (SR2128) and Mt. Holly-Huntersville Road (SR2004), go west on Mt. Holly-Huntersville Road 3.2 miles to the intersection of Mt.
Holley-Huntersville Road and Pump Station Road (SR2001).
.6 HP/O/B/1009/023 Directions for Predetermined Page 4 of 10 Survey/Sampling Locations E-8-1 From the intersection of Beatties Ford Road (SR2128) and Miranda Road (SR2025), go west on Miranda Road to the intersection of Miranda Road and Sunset Road (SR2042).
E-8-2 From the intersection of Mt. Holly-Huntersville Road (SR2004) and Hwy. 16, go south on Hwy. 16 to intersection of Hwy. 16 and Pleasant Road (SR2008).
E-8-3 From the intersection of Mt. Holly-Huntersville Road (SR2004) and Hwy. 16, go west on Mt. Holly-Huntersville.8 miles to the intersection of Mt. Holly-Huntersville Road and Harwood Lane (SR1667) - directly across from Mountainair Road.
E-10-1 From the intersection of Beatties Ford Road (SR2128) and Sunset Road (SR2108), go west on Sunset.7 miles. Turn left on Peachtree Road (SR2019), go 1.3 miles to the intersection of Peachtree Road and Oak Road (SR2027).
E-10-2 From the intersection of Mt. Holly-Huntersville Road (SR2004) and Hwy. 16, go south on Hwy. 16 (1.5 miles). Turn right on Valleydale Road, then make an immediate right (50 ft.)
onto Gumbranch Road. Go.7 miles on Gumbranch. Turn left on Cathey Road, go 1.0 miles to the intersection of Cathey Road and Tom Saddler Road.
F-5-1 From the intersection of US21 and Gilead Road (SR2136), go south on US21 (.9 miles) to the intersection of US21 and Mt. Holly-Huntersville Road (SR2004).
F-7-1 From the intersection of US21 and Gilead Road (SR2136), go south on US21 (2.9) miles.
Turn right on Alexanderana Road (SR2116), go 1.0 miles to the intersection of Alexanderana Road and Mt. Holly-Huntersville Road (SR2004).
F-8-1 From the intersection of 1-77 and Gilead Road (SR2136) - Exit #23, go south to 1-77 to the intersection of 1-77 and Reames Road (SR21 10) - Exit #18.
F-9-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Continue straight on Huntersville-Concord Road (SR2426) 3.6 miles to the intersection of Hunterville-Concord Road and Hiwasee (this also may be called Huntersville-Concord Road).
F-9-2 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Continue straight on Huntersville-Concord Road (SR2426) 2.4 miles. Turn right on Asbury Chapel Road (SR2442), go 2.4 miles to the intersection of Asbury Chapel Road and Trails End Road (SR2445).
F-10-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn right on Hwy. 115, go 2.9 miles. Turn left on Alexanderana Road (SR2457), go
.9 miles. Turn left on Eastfield Road (SR2459), to 2.3 miles to the intersection of Eastfield Road and Prosperity Church Road (SR2475).
.6 HP/O/B/1009/023 Directions for Predetermined Page 5 of 10 Survey/Sampling Locations F-10-2 From the intersection of US21 and Gilead Road (SR2136), go south on US21 5.2 miles.
Turn left on Lakeview Road (SR2112), go 1.0 miles. Turn right on Hwy. 115, go.7 miles to the intersection of Hwy. 115 and Victoria Ave. (SR263 1) Beachwood Mobile Home Park Road.
G-5-1 From the intersection of US21 and Gilead Road (SR2136), go north on US21 (3.8 miles) to the intersection of US21 and Westmoreland (SR2147).
G-5-2 From the intersection of US21 and Gilead Road (SR2136), go north on US21 (2.3 miles) to the intersection of US21 and Sam Furr Road (SR2145).
G-6-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go 3.7 miles to the intersection of Hwy. 115 and Bailey Road (SR2416).
G-6-2 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go 1.6 miles. Turn right on McCord Road (SR2427), go.3 miles.
Turn right on Hagers Road (SR2438), go.5 miles to dead end.
G-8-1 From the intersection of US21 and Gilead Road (SR2136), go north on US21 (2.3 miles).
Turn right on Sam Furr Road (SR2145), go 3.9 miles. Turn left on Davidson-Concord Road and continue to intersection of Davidson-Concord Road and Rockey River Road (SR2420).
G-8-2 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go.7 miles. Turn right on Ramah Church Road (SR2439),
go 2.4 miles to the intersection of Ramah Church Road and McCord Road (SR2427).
G-10-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go 2.0 miles. Turn right on Sam Furr Road (SR2145), go 2.7 miles.
Turn left on Davidson-Concord Road, go 2.3 miles. Turn right on Rocky River Road (SR2420), go 2.3 miles. Turn left on Shearer Road (SR2418), go 2.6 miles to the intersection of Sherarer Road and Fisher Road (SR2419).
H-6-1 From the intersection of US21 and Hwy. 73, to east on Hwy. 73.9 miles to the intersection of Hwy. 73 and Hwy. 115.
H-7-1 From the intersection of 1-77 and Hwy. 73 (Exit #28), go north on 1-77 to the intersection of 1-77 and Griffith Street (SR2158) (Exit #30).
H-7-2 From the intersection of 1-77 and Griffith Street (SR2158) Exit #30, go east on Griffith Street.9 miles to Sadler Square Shopping Center.
1-7-1 From the intersection of Brawley School Road (SRI 100) and Williamson Road (SRI 109),
go west on Brawley School Road 5.2 miles to the intersection of Brawley School Road and Garden Road (SRI 11).
.6 HP/O/B/1009/023 Directions for Predetermined Page 6 of 10 Survey/Sampling Locations 1-7-2 From the intersection of Brawley School Road (SRI 100) and Williamson Road (SRi 109),
go west on Brawley School Road 2.7 miles. Turn left on Isle of Pines Road (SRI 113),
go 3.4 miles to dead end.
1-8-1 From the intersection of Brawley School Road (SRi 100) and Williamson Road (SRI 109),
go west on Brawley School Road 3.8 miles. Turn right on Chuckwood Road (SRI 177), go to end.
1-9-1 From the intersection of Brawley School Road (SR 1100) and Williamson Road (SR 1109),
go west on Brawley School Road 3.8 miles to the intersection of Brawley School Road and Chuckwood Road (SRi 177).
1-10-1 From the intersection of Brawley School Road (SRI 100) and Williamson Road (SRI 109),
go west on Brawley School Road 3.2 miles. Turn right onto McKendries Road (SR 1115),
go 1.6 miles to the intersection of McKendries Road and Lakeview Drive (SR1455).
J-7-1 From the intersection of 1-77 and US21 (Exit #33), go west on US21 over 1-77 (.2 miles).
Turn left on Alcove Road (SR1206), go 1.8 miles. Turn right on Langtree Road (SRI 102),
go 2.0 miles to entrance Alexander Island.
J-9-1 From the intersection of 1-77 and Griffith Street (Exit #30), go east on Griffith Street (SR2158) 1 mile. Turn left on Hwy. 115, go 1.4 miles to the intersection of Hwy. 115 and Midway Lake Road (SRI 137).
J-10-1 From the intersection of 1-77 and US21 (Exit #33), go west on US21 over 1-77 (.2 miles).
Turn left on Alcove Road (SR 1206) then bear right on Catalina Road (SR 1110) go.6 miles.
Bear right on Malibur Road (SR 1194) go.4 miles to dead end at Cul-de-sac.
J-10-2 From the intersection of 1-77 and US21 (Exit #33), go east on US21 (.1 miles). Turn right on Fairview Road (SR1246), go.9 miles. Turn right on Hwy. 115, go.3 miles. Turn left at Faith Road (SR1136), go.8 miles to the intersection of Faith Road and Midway Lake Road (SRI 137).
K-9-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 6.6 miles. Turn right on Campground Road (SR1373), go 2.8 miles to the intersection of Slanting Bridge Road (SR1373) and Keistler Store Road (SR1899).
NOTE:
Campground Road turns into Slanting Bridge Road at Catawba County Line.
K-9-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 6.6 miles. Turn right on Campground Road (SR1373), go 4.8 miles. Turn right on Hwy. 150, go 1.7 miles. Turn right on Kiser Island Road (SR1841), go 3.1 miles to dead end at circle.
.6 HP/0/B1/1009/023 Directions for Predetermined Page 7 of 10 Survey/Sampling Locations NOTE:
Campground Road turns into Slanting Bridge Road at Catawba County Line.
L-l-1 From the McGuire main entrance, go west on Hwy. 73 (.5 miles) to the Cowans Ford Dam.
L-1-2 From the McGuire main entrance, go west on Hwy. 73 (1.4 miles). Turn right onto Cowans Ford Road (SR 1395), go.8 miles.
L-2-1 From the McGuire main entrance go 1.4 miles to the intersection of Hwy. 73 and Cowans Ford Road (SR 1395).
L-2-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (0.6 miles). Turn right onto Hagers Ferry Road (SR 1393) and go 1.4 miles. Go straight on paved road (Lucky Point) 0.4 miles.
M-1-1 From the McGuire main entrance, go west on Hwy. 73 (0.9 miles) to the intersection of Hwy. 73 and Caswell Road (SR1578).
M-2-1 From the McGuire main entrance, go west on Hwy. 73 (2.3 miles). Turn left onto Killian Road (SR1396), go 2.2 miles. Stop on roadside of railroad crossing.
N-2-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (.6 miles). Turn right onto Hagers Ferry Road (SR1393), go 1.4 miles. Go left onto Hager's Ferry Road (SR1393),
go 1.6 miles to where pavement ends residence 8886 Hager's Ferry Rd.
N-3-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (.6 miles). Turn right onto Hagers Ferry Road (SR 1393), go.9 miles to the intersection of Hagers Ferry Road and Nixon Heights, Lane (SR 1568).
N-3-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (2.1 miles). Turn right on Unity Church Road (SR 1439), go.3 miles. Turn right on Graham Road, go 1.6 miles to end of road.
N-4-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (2.1 miles). Turn right on Unity Church road (SR1439), go 2.4 miles to Beatties Ford Access Area.
N-5-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (3.2 miles). Turn right on Lakeshore Drive (SR1456) go 1.3 miles. Turn right on Island View Court (SR1495) go
.1 miles to dead end.
0-3-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (2.0 miles). Turn left on Sifford Road (SR1397), go 1.2 miles to the intersection of Sifford Road and Mac Lane (SR 1710).
0-4-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (1.2 miles). Stop on roadside at Hills Chapel United Methodist Church.
.6 HP/O/B/1009/023 Directions for Predetermined Page 8 of 10 Survey/Sampling Locations 0-4-2 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (.6 miles) to the intersection of Hwy. 16 and Pilot Knob Road (SR1394).
0-5-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (2.2 miles). Turn right on Old Plank Road (SR151 1), go 1.0 miles. Stop on roadside past bridge.
P-5-1 From the intersection of Hwy. 73 an Hwy. 16, go west on Hwy. 73 (1.5 miles) to the intersection of Hwy. 73 and Little Egypt Road (SR1386).
P-5-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (1.5 miles). Turn right on Little Egypt Road (SR1386), go 1.9 miles. Turn right on Optimist Club Road (SR1380),
go about.6 miles. Stop near creek.
P-6-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (3.6 miles). Turn right on Schronce Road (SR1385). Go to intersection of Schronce Road (SR1385) and Ingleside Farm Road (SR1383).
P-6-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (1.5 miles). Turn right on Little Egypt Road (SR1386), go 3.2 miles to the intersection of Little Egypt Road which is now St. James Church Road - SR1380) and Kidville Road (SR1381).
P-6-3 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (4.9 miles). Turn right on Webb's Chapel Road (SR1379), go 1.6 miles to the intersection of Webb's Chapel Road and Burton Road.
P-8-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (5.3 miles). Turn right on Beth Haven Church Road (SR1360), go 1.4 miles. Stop on roadside past bridge.
P-8-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (2.5 miles). Turn right on Ingleside Farm Road (SR1383), go.1 mile and bear left 3.2 miles more. Turn right on Beth Haven Church Road (SR1360), go 1.3 miles. Turn right on Forney Hill Road (SR1373), go.7 miles. Stop on roadside passed bridge.
P-8-3 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (7.8 miles) to the intersection of 16 and SR1373 (Campground Road or Slanting Bridge Road). Turn right on this road and go about 1.8 miles to the intersection of SR1373 and Pineridge Drive (SR1375).
P-10-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (6.8 miles) to the intersection of Hwy. 73 and Amity Church Road (SR1362).
P-10-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (2.5 miles). Turn right on Ingleside Farm Road (SR1383), go.1 miles and bear left 3.2 miles more. Turn right on Beth Haven Church Road (SR1360), go 2.8 miles to the intersection of Beth Haven Church Road and Mundy Road (SR1349).
.6 HP/O/B/1009/023 Directions for Predetermined Page 9 of 10 Survey/Sampling Locations Q-6-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (2.5 miles). Turn right on Ingleside Farm Road (SR1383), go.1 mile bear right and go 1.7 miles more. Turn left on Old Plank Road (SR151 1), go.6 miles to the intersection of Old Plank Road and Mariposa (SR1412).
Q-8-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (5.3 miles). Turn left on Brevard Place road (SR1360), go.1 mile. Turn left on Old Plank Road (SR151 1),
go 1 mile. Turn right on Mt. Zion Church Road (SR1404), go 1.9 miles. Stop on road side pass the bridge.
Q-8-2 From the intersection of Hwy. 73 and Hwy. 16, to west on Hwy. 73 (5.3 miles). Turn left on Brevard Place Road (SR1360), go.1 miles. Turn left on Old Plank Road (SR1511),
go 1.0 miles to the intersection of Old Plank Road and Mt. Zion Church Road (SR1404).
Q-10-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (5.3 miles). Turn left on Brevard Place Road (SR1360), go 3.4 miles to the intersection of Brevard Place Road and Paysour Road (SR1361).
R-3-1 From the main entrance to McGuire go west on Hwy. 73 (2.3 miles). Turn left on Killian Road (SR1396), go 3.4 miles. Stop on roadside (just past Gaston County sign).
R-5-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (7.2 miles). Turn left on Horseshoe Bend Beach Road (SR1912), go 2.0 miles. Stop on roadside passed curve.
R-5-2 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (7.2 miles). Turn left on Horseshoe Bend Beach Road (SR1912), go 1.0 miles. Stop on roadside.
R-5-3 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (7.2 miles) to the intersection of Hwy. 16 and Horseshoe Bend Beach Road (SR1912).
R-5-4*
From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (4.1 miles) to the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905).
S-7-1*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 2.0 miles. Stop on roadside at Macedona Church parking lot.
S-7-2*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 1.1 miles. Turn right on Alexis-Lucia road (SR1820),
go 1.6 miles to intersection of Alexis-Lucia Road and Old Lowesville Road (SR 1907).
S-8-1
- From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR 1905),
go south on old Hwy. 16 (2.0 miles). Turn right on Hwy. 273, go to the intersection of Hwy. 273 and Sand Ford Road (SR1918).
.6 HP/0/B1/1009/023 Directions for Predetermined Page 10 of 10 Survey/Sampling Locations S-8-2*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 3.2 miles. Go left at curve and continue 1.5 miles to the intersection of SR1935 and Old NC 27 (SR1923).
S-8-3*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 3.2 miles. Go left at curve and continue.7 miles to the intersection of Stanley-Lucia Road and Sandy Ford Road (SR1918).
S-8-4*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 1.1 miles. Turn right on Alexis Lucia (SR1820),
go 2.2 miles to the intersection of Alexis-Lucia Road and Mariposa Road (SR1902).
S-9-1" From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 1.1 miles. Turn right on Alexis Lucia Road (SR1820),
go 2.2 miles. Turn left on Mariposa (SR1902), go 1.5 miles. Turn right on Airport Road (SR 1903), go.6 miles to the intersection of Airport Road and Hwy. 27.
S-10-2*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go south on old Hwy. 16 2.0 miles. Turn right on Hwy. 273, go 4.7 miles to the intersection of Hwy. 273 and N. Main Street.
NOTE:
Old Hwy. 16 (Lucia Riverbend Hwy.) can be reached by turning right at the intersection of Hwy. 16 and Lucia Riverbend Hwy. which is 4.1 miles south on 16 from the Hwy. 73 and Hwy. 16 intersection. { * }
.7 Field Monitoring Survey Data Sheet HP/0/B/1i009/023 Page 1 of 1 Air Time Team Zone Mile Location Beta Gamma I-131 Special I
.8 HP/0/B/1009/023 Periodic Status Update for Field Monitoring Page 1 of 1 Teams Date Time Emergency Wind Speed Wind Direction Zones Affected Other Information Classification mph from'
.9 HP/0/13/1009/023 Vehicle Refueling Page 1 of 1
- 1.
Pull in at the fueling island located at the McGuire Garage. The garage is located on the right side of the access road to the McGuire switchyard.
- 2.
Place the special refueling key in the pump control station. The control station is located on a vertical steel beam which is located between the gas pump and the diesel pump.
- 3.
Remove the key, and follow the instructions as they appear on the control station. The instructions include:
- a.
Enter the vehicle's mileage.
- b.
Enter the pump being used; 1 for gas, and 2 for diesel.
- c.
Enter your social security number.
- 4.
Remove the nozzle, turn the pump on, and refuel the vehicle.
- 5.
WHEN finished, turn the pump off, and return the nozzle to the pump.
The refueling pumps are opened 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per day, 7 days a week. The McGuire Garage has personnel working in the garage from 7:30 AM to 12:00 AM Monday through Friday. Call Security from the garage gate phone to gain access to the pumps after hours or on weekends or holidays.
IF oil, antifreeze, or windshield washer fluid is needed, see McGuire Garage personnel.
.10 FMT Turnover Checklist Copies of Enclosure 5.3 from HP/O/B/1009/027.
Latest copy of Enclosures 5.7 and 5.8 from HP/O/B/1009/023.
List sampling van or emergency kit supplies needed.
HP/O/B/ 1009/023 Page 1 of 1
- 4.
List Inoperable Equipment.
- 5.
List any Sampling Problems.
- 2.
- 2.
3.
.11 Obtaining Meteorological Data from SDS HP/0/B/1 009/023 Page 1 of 1 NOTE:
IF a computer is NOT available in the OSC, Meteorological Data may be obtained from any other LAN based computer or from the OSC Radiation Protection Supervisor.
- 1.
From any LAN based computer:
- a. Select DAE
- b. Select Department Apps
- c. Select Nuclear Generation
- d. Select McGuire Desktop
- 2.
Select McGuire Process Data.
- 3.
Select SDS.
- 4. At the SDS screen, select either Unit-1 or Unit-2. For drills, select Simulator.
- 5.
Type in GD ERORD 5.
- 6.
Obtain 10 meter (lower) wind speed and 60 meter (upper) wind direction from page 1 of 3.
Other MET Data (temperature and precipitation) is also found on page 1 of 3.
- 7.
Use the 10 mile EPZ map and 90' plume marker located in the OSC to assist in determining where plume edge could be encountered. The plume marker will indicate 450 to either side of centerline wind direction.
(R04-01)
Duke Power Company PROCEDURE PROCESS RECORD (1) ID No. PTIOIA/4600/088 Revision No.
007 "PREPARATION (2) Station (3) Procedure Title McGuire Nuclear Station Functional Check of Emergency Vehicle and Equipment (4) Prepared By Gary Terrell
'0q
- '25 (5) Requires NSD 228 Applicability Determination?
E Yes (New procedure or revision with major changes)
L1 No (Revision with minor changes)
EL No (To incorporate previously approved ch nges)
(6) Reviewed By (OR)
Cross-Disciplinary Review By (QR) NA,,W Reactivity Mgmt. Review By (QR) NA Mgmt. Involvement Review By (OPS Supt.) NA (7) Additional Reviews Reviewed By
/
Reviewed By (8) Temporary Approval (if necessary)
By (OSM)
By (QR)
(9) Approved By Date January 23, 2002 Date 223',*/
Z.
Date
/
Date.
Date Date Date/-3/-02 Date Date Date Date 0z 2-.
PERFORMANCE (Compare with Control Copy every 14 calendar days while work is being performed.)
(10) Compared with Control Copy Date Compared with Control Copy Date Compared with Control Copy Date (11) Date(s) Performed Work Order Number (WO#)
COMPLETION (12) Procedure Completion Verification Dl Yes El NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?
El Yes [1 NA Required enclosures attached?
E] Yes EL NA Data sheets attached, completed, dated and signed?
EL Yes El NA Charts, graphs, etc. attached, dated, identified, and marked?
E] Yes EL NA Procedure requirements met?
Verified By Date (13) Procedure Completion Approved Date (14) Remarks (Attach additional pages, if necessary)
Form based on NSD 703 App D (Procedure Process Record)
Duke Power Company McGuire Nuclear Station Functional Check of Emergency Vehicle and Equipment Reference Use Procedure No.
PT/O/A/4600/088 Revision No.
007 Electronic Reference No.
MC0047J7
PT/O/A/4600/088 Page 2 of 5 Functional Check of Emergency Vehicle and Equipment
- 1. Purpose 1.1 To ensure that protective equipment and supplies are operational, and that capable communications exist with the various emergency personnel and emergency organizations at all times in the support of an emergency condition at the station.
1.2 The level of use for this procedure is "Reference Use".
- 2. References 2.1 NUREG--0654 (Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants) 2.2 Letter from John Dinning (MSA) December 2, 1998.
Subject:
Expiration of MSA Twin Cartridge Respirator Chemical Cartridges 2.3 SH/O/B/2001/003, Investigation of Skin and Clothing Contaminations 2.4 HP/O/B/1009/023, Environmental Monitoring for Emergency Conditions 2.5 HP/O/B/1009/025, Off-Site Radiological Transportation Incidents 2.6 HP/O/B/1009/027, Operation of ESP-2 2.7 HP/0/B/1009/022, Accident and Emergency Response 2.8 HP/OJB/1009/024, Personnel Monitoring for Emergency Conditions 2.9 NUREG-0041, Manual of Respiratory Protection Against Airborne Radioactive Materials
- 3. Time Required 3.1 Sixteen (16) manhours
- 4. Prerequisite Tests N/A
- 5. Test Equipment N/A I
PT/O/A/4600/088 Page 3 of 5
- 6. Limits and Precautions 6.1 Each emergency equipment kit shall be inventoried and checked for operability on a quarterly basis (Reference 2.1).
- An intact emergency equipment tamper seal can be used to verify the inventory; however, a complete item by item inventory shall be conducted at least once per year.
6.2 The emergency respirators shall be inspected monthly for dry rot and deformation.
6.3 Personnel using an emergency vehicle shall wear seat belts.
6.4 Personnel shall follow all FCC regulations during radio transmissions.
6.5 Note any identified discrepancy on the proper enclosure and leave the enclosure in the kit.
After resolving the discrepancy, make a separate note on the enclosure stating the resolution date and the name of the person performing the resolution.
6.6 Combination cartridges have no specific shelf life (Reference 2.2). These cartridges shall be replaced if they are exposed to adverse environmental conditions such as high humidity. To ensure that these cartridges are replaced periodically, cartridges should be ordered from the supplier (MSA, Part No. 4698C) three months prior to the date that is three years after the date of manufacture.
6.7 After the use of any emergency kit, a full inventory of that kit is required. The checklist shall be signed and dated each time the kit is inventoried.
6.8 During instrument calibration, the check source kept in the Administration Building area may be taken out by the Instrument Cal. Lab for response checks. WHEN the calibration of instruments is complete, the check source shall be returned to the Emergency Equipment cabinets in the Administration Building.
6.9 The supplies listed on the emergency kit inventory are the minimum quantity required. Any extra supplies for drill purposes, etc. are acceptable.
6.10 Respirators shall be stored so that they are not damaged by adjacent equipment or twisted out of normal configuration (Reference 2.9). Elastic straps should be placed inside the mask to prevent deformation.
6.11 Electronic Dosimeters in Emergency Kits (except MSC-2 and MDK-1) are programmed for
'Fast Entry' mode and should only be turned on for emergency use. EDs in 'Fast Entry' mode should display "pause". IF an ED in 'Fast Entry' mode is found on, it shall be removed from service and returned to RP Staff to be reset to 'Fast Entry' mode.
- 7. Required Station Status N/A
PT/O/A/4600/088 Page 4 of 5
- 8. Prerequisite System Conditions N/A
- 9. Test Method N/A
- 10. Data Required 10.1 For each inventory and verification that is performed in accordance with this procedure, the appropriate check-off list shall be completed. Refer to the list of enclosures in Section 13 of the procedure.
- 11. Acceptance Criteria 11.1 All required enclosures are completed.
- 12. Procedure 12.1 Monthly Emergency Equipment Inspection 12.1.1 Monthly, complete all inspection requirements per Enclosure 13.1. Sign and date the enclosure and route to RP Staff Representative.
12.2 Quarterly Emergency Kit Inspection 12.2.1 Once per quarter, complete all monthly and quarterly inspection requirements per 3.1 and 13.2. Sign and date the enclosures and route to RP Staff Representative.
12.2.2 Perform a functional check of all communication equipment per Enclosure 13.24.
Sign and date the enclosure and route to RP Staff Representative.
12.2.3 Perform a functional verification on EMF54A and 54B per Enclosure 13.25. Sign and date the enclosure and route to RP Staff Representative.
12.3 Annual Emergency Kit Inspection 12.3.1 Annually perform a complete item inventory of each emergency kit. Document the inventory, including the monthly and/or quarterly requirements on Enclosures 13.1, 13.2 and 13.3. Sign and date the enclosures and route to the RP Staff Representative.
- 13. Enclosures 13.1 Monthly Emergency Equipment/Kit Inspection 13.2 Quarterly Emergency Equipment/Kit Inspection
PT/OIAI4600/088 Page 5 of 5 13.3 Annual Emergency Equipment/Kit Inspection 13.4 Emergency Kit Locations 13.5 Required Changeouts 13.6 Environmental Survey Kit Checklist - Sample Van (Vehicle #3224) 13.7 Environmental Survey Kit Checklist - Sample Van (Vehicle #3233) 13.8 Environmental Survey Kit Checklist - Survey Vehicle 13.9 Environmental Survey Kit Checklist - Survey Vehicle 13.10 Transportation Accident Kit Checklist 13.11 Miscellaneous Kit Checklist 13.12 Personnel Survey Kit Checklist - RP Instrument Calibration Lab 13.13 Personnel Survey/Recovery Kit Checklist - Admin. Building (Room 158) 13.14 Personnel Survey Kit Checklist - Cowan's Ford Dam 13.15 Recovery Kit Checklist - Cowan's Ford Dam 13.16 Personnel Survey Kit Checklist - Training Center 13.17 Recovery Kit Checklist - Training Center 13.18 Recovery Kit Checklist - Control Room 13.19 Decontamination Kit Checklist - First Aid Room 13.20 Decontamination Kit Checklist - Carolinas Medical Center 13.21 Operations Support Center Kit Checklist 13.22 Technical Support Center Kit Checklist 13.23 Monthly Respirator Inspection Sheet 13.24 Communication Equipment Check Guidelines 13.25 EMF 54 Flow Check 3.1 MONTHLY EMERGENCY EQUIPMENT/KIT INSPECTION PT/O/A/4600/088 Page 1 of 1 Check Off El 13.1.1 Inspect all emergency kit respirators monthly per the guidelines on Enclosure 13.23 (Monthly Respirator Inspection Sheet). The inspection shall be documented on Enclosure 13.23. Ensure that all appropriate blanks are signed.
1]
13.1.2 Verify that the GMI-H respirator cartridges (MSA, Part No. 4698C) do not need replacement. Replace all cartridges three years from the date of manufacture.
El 13.1.3 Verify that all procedures/documents contained in emergency kits are the most current revision. Enter the revision number on the applicable checklist.
El 13.1.4 Verify emergency kit tamper seals intact.
El 13.1.5 Reinventory of emergency kit(s) due to broken seal. Sign and date the applicable emergency kit checklist after reinventory due to broken seal.
I Date Signature 3.2 PT/O/A/4600/088 QUARTERLY EMERGENCY EQUPMENT/KIT Page 1 of 1 INSPECTION Check Off
[]
13.2.1 Verify all monthly inspection requirements have been met.
El 13.2.2 Perform a battery check of each instrument in the emergency kits.
Replace any batteries that are weak or dead.
El 13.2.3 Check all batteries in emergency kits for strength and condition.
Replace any batteries that are weak or dead.
Li 13.2.4 Verify that all electronic dosimeters are within calibration. Electronic dosimeters are calibrated every six months.
o 13.2.5 Verify that all electronic dosimeters in Fast Entry mode display "pause".
Replace any electronic dosimeters which do NOT display "pause".
0 13.2.6 Verify that all potassium iodide tablets are within expiration dates.
Expiration date:
0 13.2.7 Check operability of emergency communication equipment at a distance of ten (10) miles from the McGuire Site. Refer to 3.24 (Communication Equipment Check Guidelines) for instructions.
0 13.2.8 Verify that actual flow is at least 1 scfm at EMF-54A and EMF-54B (located on the north end of each Turbine Building operating floor),
per instructions on Enclosure 13.25 (EMF Flow Check) and document all data on enclosure.
Signature Date 3.3 Annual Emergency Equipment/Kit Inspection PT/O/A/4600/088 Page 1 of 1 Check Off 0
13.3.1 Perform a complete item inventory of each emergency kit per the applicable checklist. Sign and date the checklist and leave in the emergency kit.
LI 13.3.2 Verify all monthly and quarterly requirements have been met.
Signature Date 3.4 EMERGENCY KIT LOCATIONS PT/0/A/4600/088 Page 1 of 1 KIT ID#
- 1. ESK-1 (Sample Van)
- 2. ESK-2 (Sample Van)
- 3. ESK-3 (Survey Vehicle)
- 4. ESK-4 (Survey Vehicle)
- 5. TAK-1
- 6. MSC-2
- 7. PSK-1
- 8. PSK-2
- 9. PSK-3
- 10. R-CFD
- 11. PSK-4
- 12. R-TTC
- 13. R-CR1
- 14. MDK-1
- 15. MDK-2
- 16. OSC-1
- 17. TSC-1 KIT TYPE Envr. Survey Envr. Survey Envr. Survey Envr. Survey Transportation Accident Miscellaneous Personnel Survey Personnel Survey/Recovery Personnel Survey Recovery Personnel Survey Recovery Recovery Medical Decon.
Medical Decon.
OSC TSC LOCATION Sample Van (Vehicle #3224)
Sample Van (Vehicle #3233)
Admin. Rm. 158, cabinet #2 Admin. Rm. 158, cabinet #2 Admin. Rm. 158, cabinet #1 Admin. Rm. 158 RP Instrument Calibration Lab Admin. Rm. 158 Cowan's Ford Dam Cowan's Ford Dam Training Center (Bldg. 7403)
Training Center (Bldg. 7403)
Control Room Aux. Bldg. (First Aid Room)
Carolinas Medical Center Operations Support Center Technical Support Center 3.5 REQUIRED CHANGEOUTS PT/0/A/4600/088 Page 1 of 1 ITEM Respirator Combination Cartridges MSA Part 4698C Potassium Iodide Radiation Protection Instruments Electronic Dosimeters Procedures/Documents SH0/B1/2001/003 HP/0/B/1 009/022 HP/O/B/1009/023 HP/0/B/1009/024 HP/0/B/1009/025 HP/0/B/1009/027 SRWP98 FREQUENCY per manufacturer cartridge no.
per manufacturer every six months every six months NEXT DUE DATE per RPIC per RPIC Current Revision or Approval Date I
3.6 ENVIRONMENTAL SURVEY KIT CHECKLIST SAMPLE VAN VEHICLE #3224 PT/O/A/4600/088 Page 1 of 1 KIT I.D. ESK-1 REQUIRED
\\IIF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe (located in Admin. Rm. 158) 1 Eberline Model RO-20 or Equivalent (located in Admin. Rm. 158) 1 Potassium Iodide Tablets (bottle) 1 Protective Clothing (disposable sets) 3 Poly Bags (various sizes) 6 Masking Tape (roll) 1 Cubitainers 6
Hand Gardening Spade 1
Limnological Sampler 1
Stopwatch 1
Flashlight 1
Batteries, D-cell 4
CP100G Filter Cartridges and Particulate Filters 30 each Labels for Filter Cartridges 30 NuCon Smears (box)
I ESK-I Vehicle Booklet containing:
I legal pad and Ten Mile Zone Sectors Map - MNS SHIO/B/2001/003 IHP/O/B/1009/023 HP/O/B/1009/027 SRWP 98 Pen 2
Grease Pencil 1
Grass Clippers 1
Calculator I
Disposable Gloves, bag 1
Disposable Shoe Covers 12 pair ESP-2 with Ba-133 source (located in Admin. Rm. 158) 1 Rainsuits I
Cs-137 Check Source (Cs-7A) 1 Rasp Air Sampler 1
Discrepancies/Resolutions:
Inventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.7 ENVIRONMENTAL SURVEY KIT CHECKLIST SAMPLE VAN VEHICLE #3233 PT/O/A/4600/088 Page 1 of 1 KIT I.D. ESK-2 REQUIRED "1 IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe (located in Admin. Rmn. 158) 1 Eberline Model RO-20 or Equivalent (located in Admin. Rm. 158) 1 Potassium Iodide Tablets (bottle) 1 Protective Clothing (disposable sets) 3 Poly Bags (various sizes) 6 Masking Tape (roll) 1 Cubitainers and caps 6
Limnological Sampler 1
Hand Gardening Spade 1
Stopwatch 1
Flashlight 1
Batteries, D-cell 4
CP100G Filter Cartridges and Particulate Filters 30 each Labels for Filter Cartridges 30 NuCon Smears (box) 1 ESK-2 Vehicle Booklet containing:
1 legal pad and Ten Mile Zone Sectors Map - MNS SH/0/B/2001/003 HP/O/BI 1009/023 HP/O/B/1009/027 SRWP 98 Pen 2
Grease Pencil 1
Grass Clippers 1
Calculator 1
Disposable Gloves, bag 1
Disposable Shoe Covers 12 pair Rainsuits 1
ESP-2 with Ba-133 check source (located in Admin. Rm. 158) 1 Cs-137 Check Source (Cs-7A) 1 Rasp Air Sampler 1
Discrepancies/Resolutions:
Inventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.8 ENVIRONMENTAL SURVEY KIT CHECKLIST SURVEY VEHICLE PT/O/A/4600/088 Page 1 of 1 KIT I.D. ESK-3 REQUIRED IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe (located in Admin. Rm. 158) 1 Eberline Model RO-20 or Equivalent (located in Admin. Rm. 158) 1 Potassium Iodide Tablets (bottle) 1 Flashlight 1
Batteries, D-cell 4
NuCon Smears (box) 1 ESK-3 Vehicle Booklet containing:
1 legal pad and Ten Mile Zone Sectors Maps - MNS SHIO/B/20011003 HP/0/B/10091023 SRWP98 Pen 2
Calculator 1
Disposable Gloves, bag I
Cs-137 Check Source (Cs-7A) 1 I
Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.9 ENVIRONMENTAL SURVEY KIT CHECKLIST SURVEY VEHICLE PT/O/A/4600/088 Page 1 of 1 KIT I.D. ESK-4 REQUIRED
'i IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe (located in Admin. Rm. 158) 1 Eberline Model RO-20 or Equivalent (located in Admin. Rm. 158) 1 Potassium Iodide Tablets (bottle) 1 Flashlight 1
Batteries, D-cell 4
NuCon Smears (box) 1 ESK-4 Vehicle Booklet containing:
1 legal pad and Ten Mile Zone Sectors Map - MNS SHIO/B/2001/003 IP/O/B/1009/023 SRWP 98 Pen 2
Quarter Roll 1
Calculator 1
Disposable Gloves, bag 1
Cs-137 Check Source (Cs-7A) 1 Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.10 TRANSPORTATION ACCIDENT KIT CHECKLIST PT/0/A/4600/088 Page 1 of 1 KIT I.D. TAK-1 REQUIRED I IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe 2
MSA Ultra Twin Respirator w/Combination Cartridge 2
Step Off Pads 3
50 yard roll of Barricade Tape (magenta and yellow) 4 Box of small Kimwipes 2
Electronic Dosimeters 5
Transportation Accident Kit Booklet 1
containing legal pad and IP/0/BI1009/025 Pens 2
NuCon Smears (box) 3 Cotton Gloves, bundle 1
Shoe Covers, disposable, pair 20 All Purpose Marker 2
Scotch Tape Roll and Dispenser 1
Masking Tape, 1 roll 1" and 1 roll 2" 2
Rain Suit, disposable 2
Weather-Proof Caution Signs with Inserts 4
Radioactive Waste Signs (4" x 6" )
25 Caution: Radiation/Radioactive Material Tags 12 Binoculars 1
Plastic Sample Bottles 12 Thermometer 2
Flashlight 2
Batteries, D Cell 4
CP-100 Cartridges 10 each Particulate Filters 10 Roll of Duct Tape 2
Poly Bags 12 Protective Clothing (disposable sets) 6 Safety Glasses 5
Hard Hats 3
Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date 3.11 MISCELLANEOUS KIT CHECKLIST PT/O/A/4600/088 Page 1 of 1 KIT I.D. MSC-2 (Admin Room 158)
REQUIRED
\\IIF ITEM AMOUNT PRESENT Radeco H809V Air Samplers (Cabinet #2) 2 Emergency 800 MHz Radios (Cabinet #1) 6 Limnological Sampler (Cabinet #1) 1 MSA Ultra Twin Respirator w/Combination Cartridge (Cabinet #2) 10 Electronic Dosimeters 15 Electronic Dosimeter Reader 1
Leave a copy of this sheet in Cabinet 1.
Signature/Date 3.12 PERSONNEL SURVEY KIT CHECKLIST RP INSTRUMENT CALIBRATION LAB PT/OIA/4600/088 Page 1 of 1 KIT I.D. PSK-1 REQUIRED
'1IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe 1
MSA Ultra Twin Respirators w/Combination Cartridges 4
Potassium Iodide Tablets (bottle) 1 Protective Clothing (disposable sets) 6 Boundary Ribbon or Rope (50 yd. Roll) 1 Caution Signs w/inserts 4
Masking Tape (roll) 1 Poly Bags (various) 6 NuCon Smears (box) 2 PSK-1 Booklet containing:
1 Legal pad SH/O/B/2001/003 HP/0/B/1009/022 HP/0/B/1009/024 Pen 2
Grease Pencil 1
Disposable Coveralls (case - in separate container) 1 Batteries, D cell 4
Cs-137 Check Source (Cs-7A) 1 I Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.13 PERSONNEL SURVEY/RECOVERY KIT CHECKLIST ADMIN. BLDG. (ROOM 158)
PT/O/A/4600/088 Page 1 of 1 KIT I.D. PSK-2 REQUIRED
- IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe 2
MSA Ultra Twin Respirators w/Combination Cartridges 4
Potassium Iodide Tablets (bottle) 150 Protective Clothing (disposable sets) 6 Rain Suits 2
Boundary Ribbon or Rope (50 yd. Roll) 1 Caution Signs w/inserts 4
Masking Tape (roll) 1 Poly Bags (various) 6 NuCon Smears (box) 2 PSK-2 Booklet containing:
1 legal pad SH/0/B/2001/003 HP/0/B/10091022 HP/0/B/1009/024 Pen 2
Grease Pencil 2
Hand Soap 10 Hand Brushes 2
Disposable Towels 1 pk.
Fingernail Clippers 1
Flashlight 1
Disposable Coveralls (case - in separate container) 1 Small Sample Bottles 60 Batteries, D cell 4
Cs-137 Check Source (Cs-7A) 1 Discrepancies/Resolutions:
Inventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date Signature/Date 3.14 PERSONNEL SURVEY KIT CHECKLIST COWAN'S FORD DAM PT/O/A/4600/088 Page 1 of 1 KIT I.D. PSK-3 REQUIRED
'1IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 w/probe 2
Electronic Dosimeters 4
MSA Ultra Twin Respirators w/Combination Cartridges 4
Potassium Iodide Tablets (bottle) 2 Small Sample Bottles 4
Protective Clothing (disposable sets) 6 Boundary Ribbon or Rope (50 yd. Roll) 2 Caution Signs w/inserts 6
Masking Tape (roll) 1 Poly Bags (various) 6 NuCon Smears (box) 2 PSK-3 Booklet containing:
I legal pad SHfO/B/2001/003 HP/O/B/1009/022 HP/0/B/1009/024 Pens 2
Grease Pencil 2
Hand Soap 10 Hand Brushes 2
Disposable Towels 1 pk.
Fingernail Clippers 1
Disposable Coveralls (case - in separate container) 1 Batteries, D cell 4
Cs-137 Check Source (Cs-7A) 1I Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.15 RECOVERY KIT CHECKLIST COWAN'S FORD DAM PT/O/A/4600/088 Page 1 of 1 KIT I.D. R-CFD REQUIRED
' IF ITEM AMOUNT PRESENT Electronic Dosimeters 2
Boundary Ribbon or Rope (50 yard roll) 1 Masking Tape (roll) 1 Rain Suits 2
Protective Clothing (disposable sets) 2 Poly Bags (various) 12 Caution Signs w/inserts 2
R-CFD Booklet (containing legal pad) 1 Pens 2
Grease Pencil 2
MSA Ultra-Twin Respirators w/Combination Cartridges 2
Potassium Iodide Tables (Bottles) 470 NuCon Smears (box) 2 Soap (bar) 6 Flashlight 1
Batteries, D cell 4
Small Sample Bottles 200 Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.16 PERSONNEL SURVEY KIT CHECKLIST TRAINING CENTER PT/',OIA4600/088 Page 1 of 1 KIT I.D. PSK-4 REQUIRED
- /IF ITEM AMOUNT PRESENT Eberline E-520 or E-120 with probe 2
Electronic Dosimeters 4
MSA Ultra Twin Respirators w/Combination Cartridges 4
Potassium Iodide Tablets (bottle) 2 Small Sample Bottles 4
Protective Clothing (disposable sets) 6 Boundary Ribbon or Rope (50 yd. Roll) 2 Caution Signs w/inserts 6
Masking Tape (roll) 1 Poly Bags (various) 6 NuCon Smears (box 2
PSK-4 Booklet containing:
1 legal pad SH/0/B/2001/003 HP/0/B/1009/022 HP/0/B/1009/024 Pens 2
Grease Pencil 2
Hand Soap 10 Hand Brushes 2
Disposable Towels 1 pk.
Fingernail Clippers 1
Disposable Coveralls (case - in separate container) 1 Batteries, D cell 4
Cs-137 Check Source (Cs-7A) 1 Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.17 RECOVERY KIT CHECKLIST TRAINING CENTER PT/O/A/4600/088 Page 1 of 1 KIT I.D. R-TTC REQUIRED
\\IIF ITEM AMOUNT PRESENT Electronic Dosimeters 2
Boundary Ribbon or Rope (50 yd. Roll) 1 Masking Tape (roll) 1 Rain Suits 2
Protective Clothing (disposable sets) 2 Poly Bags (various) 12 Caution Signs w/inserts 2
R-TTC Booklet (containing legal pad) 1 Pens 2
Grease Pencil 1
MSA Ultra-Twin Respirators w/Combination Cartridges 2
Potassium Iodide Tablets (Bottles) 150 NuCon Smears (box) 2 Soap (bar) 6 Flashlight 1
Batteries, D cell 4
Small Sample Bottles 60 Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.18 RECOVERY KIT CHECK LIST CONTROL ROOM PT/O/A/4600/088 Page 1 of 1 KIT I.D. R-CRI REQUIRED
\\IIF ITEM AMOUNT PRESENT Boundary Ribbon or Rope (50 yd. Roll)
I Masking Tape (roll)
I Rain Suits 2
Protective Clothing (disposable sets) 2 Poly Bags (various) 12 Caution Signs w/inserts 2
R-CR1 Booklet (containing legal pad) 1 Pens 2
Grease Pencil 1
MSA Ultra-Twin Respirators w/Combination Cartridges 2
Potassium Iodide Tablets (Bottles) 150 NuCon Smears (box) 2 Soap (bar) 6 Flashlight 1
Batteries, D cell 4
Small Sample Bottles 60 Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.19 DECONTAMINATION KIT CHECKLIST FIRST AID ROOM PT/O/A/4600/088 Page 1 of 1 KIT I.D. MDK-1 REQUIRED 4I IF ITEM AMOUNT PRESENT Eberline RM014 w/HP-210 Probe (CAF) 1 Germicidal Spray Cleaner 3
Disposable Towels 10 Poly Bags (various) 6 Fingernail Clippers 1
NuCon Smears 2
Hand Brushes 2
Hand Soap 10 Protective Clothing (disposable sets) 4 Disposable Rain Suits 2
MDK-1 Booklet containing:
1 RP/O/A15700/05 Tape, Radioactive Material 1
Tape, Masking 2" 1
Tape, Duct 2" 1
Absorbent Pads (box) 1 Rad Ribbon 1 50' roll Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.20 DECONTAMINATION KIT CHECKLIST CAROLINAS MEDICAL CENTER PT/O/A/4600/088 Page 1 of 2 KIT I.D. MDK-2 REQUIRED
' IF ITEM AMOUNT PRESENT Drawer #1 Procedure Book (H) 1 Inventor Sheet 1
Drawer #2 Culturettes (H) 6 Smears (Nucon) 3 boxes Drawer #3 Poly Bags 6
Zip Lock Poly Bags 10 Drawer # 4 Betadine Surgical Scrub (H) 1 Betadine Solution (H) 1 500 ml Distilled Water (H)
I Hand Brushes 4
Gauze Sponges 4"x4", 12 ply (H) 20 Surgipad Combine Dressing ()
5 Drawer #5 Radiation Caution Signs w/inserts 8
Rad Ribbon 2 rolls Blue Pads (H) 1 bag Masking Tape 2" wide 6 rolls Drawer # 6 Batteries, D-Cell (check condition) 4 Nail Clippers 1
Electronic Dosimeters 8
Electronic Dosimeter Reader 1
Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.20 DECONTAMINATION KIT CHECKLIST CAROLINAS MEDICAL CENTER PT/OAIA4600/088 Page 2 of 2 KIT I.D. MDK-2 REQUIRED IF ITEM AMOUNT PRESENT Drawer #7 Disposable Protective Clothing 10 Each set is placed in Zip Loc Poly Bag and labeled.
One set contains:
Disposable Coveralls 1 pair cotton liners 1 pair PVC gloves 1 pair PVC booties 1 pair Eyeshields 1 hair cover (H) 1 Fluid Shield Mask (H)
XXXL Disposable Coveralls 10 Drawer #8 Safety Glasses 10 Additional Clothing NA Drawer #9 Hair Clipper Set 1
Thermometers, Disposal (H) 2 Masslin Cloth 1 pack Drawer #10 E-120 w/probe 1
E-520 w/probe 1
Source CS-7a 1
Drawer #11 Vinyl Gloves (H) 1 box Specimen Cups (H) 4
"* Supplies followed by (H) are obtained from Hospital personnel. Contact the Training Coordinator at Carolina's Medical Center at 355-2838.
"* Notify Radiation Protection three (3) months prior to calibration expiration date.
Verify calibration date of instruments and perform battery check.
Instrument Calibration Date Calibration Due E-120 E-520 Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Signature/Date Signature/Date 3.21 OPERATIONS SUPPORT CENTER KIT CHECKLIST PTIO/A/4600/088 Page 1 of 2 KIT I.D.OSC-1 REQUIRED
- 'IF ITEM AMOUNT PRESENT MSA Ultra Twin Respirator w/Combination Cartridges 4
Flashlight 4
Batteries, D-cell 8
Eberline E-520/E-120 1
Potassium Iodide (bottles) 25 Poly Bags 12 Pkg. Respirator Cards I
Log Book 1
OSC-1 Booklet (contains legal pad) 1 Nucon Smears (box) 2 CP-100 cartridges 30 Particulate Filters 30 Labels for Filter Cartridges 30 Plastic Bags for Cartridges 30 Pens 1 box Stopwatch 1
Cs-137 Check Source (Cs-7A) 1 3.21 OPERATIONS SUPPORT CENTER KIT CHECKLIST PT/0/A/4600/088 Page 2 of 2 KIT I.D. OSC-1 (continued)
REQUIRED
\\IIF ITEM AMOUNT PRESENT The following supplies are located in the OSC Emergency Equipment Locker Rain Suits 16 Shoe Covers 16 pr.
Rubber Gloves 1 bag Cotton Liners 1 bag Sack Suits 1 box Disposable Hoods 1 bag Step Off Pads 5
Tape, Masking 2" 4
Caution Signs w/inserts 5
Extension Cord 1
Protective Clothing (set) 4 Discrepancies/Resolution:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.22 TECHNICAL SUPPORT CENTER KIT CHECKLIST PT/O/A/4600/088 Page 1 of 1 KIT I.D.TSC-1 REQUIRED
- IF ITEM AMOUNT PRESENT Protective Clothing (disposable sets) 6 MSA Ultra Twin Respirator w/Combination Cartridges 6
CP-100 Cartridges and Particulate Filters 25 each Labels for Filter Cartridges 25 Potassium Iodide Tablets (bottle) 25 Caution Signs w/inserts 3
Rad Ribbon 2
Nucon Smears (box) 1 Plastic Bags 6
Masking Tape (roll) 1 Pen 2
Grease Pencil 1
Frisker Stand (not in kit) 1 Duct Tape (roll) 1 Radeco H809V Air Sampler (located outside kit) 1 TSC key located in Work Control Center.
Discrepancies/Resolutions:
Inventoried:
Signature/Date Reinventoried:
Reinventoried:
Reinventoried:
Reinventoried:
Signature/Date Signature/Date Signature/Date Signature/Date 3.23 KIT TYPE Envr. Survey Envr. Survey Envr. Survey Envr. Survey Transportation Accident Personnel Survey Personnel Survey/Recovery Personnel Survey Recovery Kit Personnel Survey Recovery Kit Recovery Operation Support Center Technical Support Center MONTHLY RESPIRATOR INSPECTION SHEET MONTH LOCATION Admin. Room 158 Admin. Room 158 Admin. Room 158 Admin. Room 158 Admin. Room 158 RP Instrument Cal Lab Admin. Bldg. Room 158 Cowans Ford Dam Cowans Ford Dam TTC TTC Control Room Work Control Center Area TSC Dose Assessment Area PT/0/A/4600/088 Page 1 of 1 RESPIRATOR INSPECTED NUMBER BY (signature) 3 3
2 2
2 4
4 4
2 4
2 2
4 6
44 INSPECTION CRITERIA Check all surfaces for dry rot or deformation.
Check lens retaining ring for integrity.
Check lens for clarity.
Remove exhalation valve cover.
Check exhalation valve for dry rot, deformation, cracks, tears and residue.
Check placement of exhalation valve cover.
Ensure the inhalation valves are in place on both sides and that there are no visible defects.
Check the headstraps for dry rot or deformation. They should be stored loosely, inside the facepiece, not strapped over the lens of the facepiece.
Return completed enclosure to the Staff Representative.
RESPIRATOR CHECKS COMPLETED I
Signature(s)
Date I
Staff Representative Signature Date KIT ID#
ESK-1 ESK-2 ESK-3 ESK-4 TAK-1 PSK-1 PSK-2 PSK-3 R-CFD PSK-4 R-TrC R-CR1 OSC-1 TSC-1 3.24 PT/O/A/4600/088 COMMUNICATION EQUIPMENT CHECK Page 1 of 1 GUIDELINES BASE STATION: Turn on radio base station and use call sign WQC700 to sign on. 'This is WQC700 McGuire base signing on for radio check". After radio check is completed, sign off using call sign. IF CNS is using the radios for a drill or emergency, abandon check.
PORTABLE RADIOS: Six (6) 800 MHz hand held radios located in cabinet #1, Room 158 of the Administration Building.
Two (2) mobile radios in each sample van (vehicles 3224 and 3233). To test the portable radios:
- 1.
Remove the radio from the charger.
- 2.
Screw in antenna to the top of the radio.
- 3.
Turn off/on/volume control switch on the top of the radio until SELF TEST is digitally displayed on the front.
MCGUIRE C17 will be displayed. IF MCGUIRE C17 is not displayed after SELF TEST, turn the numbered dial on the top of the radio to position 3. Ensure small toggle is set to position A. Radio is now ready to transmit and receive.
No squelch adjustment is required.
- 4.
Test the radios using the mobile call sign ("WQC 700, McGuire base, this is KA82138, radio check of portable radio number XXXX. Do you copy?") Designate each portable by the DPC number engraved on the side. It is necessary to exchange batteries, make sure the radio is turned off before removing or replacing it.
- 5.
Turn the radio off after testing.
- 6.
Remove the antenna and place in the storage cabinet.
- 7.
Place the radio into a charging unit.
- 8.
Ensure that the cabinet is closed and locked.
MOBILE EMERGENCY VAN RADIOS: One (1) located in the front of each vehicle.
- 1. Turn on the unit by pressing power button.
- 2.
The unit will display SELF CHECK, press the mode key until MCGUIRE is displayed. You are ready to transmit and receive.
IMPORTANT: Ensure that the radio is turned off after returning from exercise or emergency.
These units will not turn off automatically when the van is turned off. Leaving the radio on will result in a vehicle dead battery.
CELLULAR PHONES: One (1) located in each vehicle.
- 1.
Turn on the cellular phone.
- 2.
Unlock the phone for use by pressing the last three (3) digits of the cell phone number.
- 3.
Test the phone by call TSC dose assessment at 875-4976.
TEN-MILE RADIO CHECK LOCATIONS: Any location on the 10 mile EPZ perimeter is satisfactory for testing. Avoid stopping vehicles on the shoulder of the road during radio checks.
VERIFICATION OF EMERGENCY COMMUNICATIONS This document shall serve as written verification that McGuire Nuclear Station's emergency radio transmitter/receivers have been successfully checked for operation at the distances prescribed by this procedure. (To be done quarterly).
Discrepancies Noted:
Corrective Actions Taken:
Signature/Date 3.25 EMF54 FLOW CHECK PT/01A/4600/088 Page 1 of 1 INSTRUCTIONS:
"* Start both EMF's using the TSC motor controller by pressing the start button.
"* Verify actual flow is 1 scfmn at each package. (Document below).
"* Secure the EMLF's using the TSC motor controller by pressing the stop button and the acknowledge button when loss of flow alarm sounds.
EMF54A Observed flow (fo):
Observed vacuum (Vo)
Actual flow (fa)
EMF54B Observed flow (fo):
Observed vacuum (Vo)
Actual flow (fa)
Use:
cfm inches of Hg.
scfm cfm
_inches of Hg.
scfm 129.92 - Vo fa =fo 29.92 Discrepancies:
Signature/Date