ML033290615
| ML033290615 | |
| Person / Time | |
|---|---|
| Site: | McGuire, Mcguire |
| Issue date: | 11/20/2003 |
| From: | Gordon Peterson Duke Power Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| -RFPFR | |
| Download: ML033290615 (73) | |
Text
Duke ArPowere A Duke Energy Company GARY R. PETERSON Vice President McGuire Nuclear Station Duke Power MGOI VP / 12700 Hagers Ferry Road Huntersville, NC 28078-9340 November 20, 2003 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Re:
McGuire Nuclear Station Units 1 & 2, Docket Nos.
Change to Emergency Plan Implementing Procedure 704 875 5333 704 875 4809 fax grpeters@duke-energy. com 50-369, 50-370 Attached to this letter are a revised Emergency Plan Implementing Procedure (EPIP) Index and a copy of one (1) revised Emergency Plan Implementing Procedure.
This procedure revision was evaluated pursuant to the requirements of 10 CFR 50.54 (q).
This change does not constitute a reduction in the effectiveness of the emergency plan and the plan continues to meet the requirements of 10 CFR 50.47 (b) and 10 CFR 50 Appendix E. Duke implemented this change on October 23, 2003. A copy of this change is also being sent to the NRC Office of Nuclear Material Safety and Safeguards as per 10 CFR 72.44 (f).
Revision bars within the procedure indicate the revision. The following procedure index change and procedure revision have been implemented:
EPIP Index Page 1 EPIP Index Page 2 EPIP Index Page 3 Dated 10/23/2003 Dated 10/23/2003 Dated 10/23/2003 REVISION to the following procedure:
RP/0/A/5700/012 Dated 10/23/2003 Rev. 22A There are no new regulatory commitments in this document.
Duke is also supplying two copies of this submittal to the Regional Administrator of Region II.
Questions on this document should be directed to Kevin Murray at (704) 875-4672.
Gary R. Peterson Attachments AcA
www. duke-energy. corn
U.S. Nuclear Regulatory Commission November 20, 2003 Page 2 xc:
(w/attachment)
Mr. Luis Reyes, Regional Administrator U.S. Nuclear Regulatory Commission Region II 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303 (w/attachment)
Mr. Martin J. Virgilio, Director Office of Nuclear Material Safety and Safeguards Mail Stop T-8A23 Washington, D.C. 20555-0001 (w/attachment)
MNS Master File No. 529.01 (w/o attachment)
R. E. Martin, USNRC U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C.
20555 NRC Resident Inspector McGuire Nuclear Station M.T. Cash, Manager NRIA (ECO50)
Electronic Licensing Library (ECO50)
EP File 111
DUKE POWER McGUIRE NUCLEAR SITE EMERGENCY PLAN IMPLEMENTING PROCEDURES APPROVED:
S 17 A§SURANCE MANAGER DATE APPROVED
///1/
I7 3
EPIP Index Page 1 EPIP Index Page 2 EPIP Index Page 3 Dated 10/23/2003 Dated 10/23/2003 Dated 10/23/2003 RP/O/A/5700/012 Dated 10/23/2003 Rev. 22A
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
TITLE REVISION NUMBER RPIO/A/5700!000 RPIO/A15700/001 RP/O/A/5700/002 RP/O/A/5700/003 RP/0IA/5700/004 RP/0/A15700/05 RP/O/A157001006 RP/O/A15700/007 RP/O/A157001008 RP/0/A15700/009 RPIO/A/5700/010 RP/0/A157001011 RP10/A157001012 RP/O/A15700/013 RPIO/A/5700/14 RP/0/A15700/015 RPIO/A15700/16 RP10/A15700/17 RP/O/A15700/018 RP/O/A15700/019 RP10/A15700/020 RP/0/A/5700/21 RPIO/A/57001022 RP/O/A/5700/024 RP/O/A/5700/026 RP/O/B157001023 OP/O/B/6200/090 Classification of Emergency Notification of Unusual Event Alert Site Area Emergency General Emergency Care and Transportation of Contaminated Injured Individual(s) From Site to Offsite Medical Facility Natural Disasters Earthquake Release of Toxic or Flammable Gases Collisions/Explosions NRC Immnediate Notification Requirements Conducting a Site Assembly, Site Evacuation or Containment Evacuation Activation of the Technical Support Center (TSC)
Activation of the Emergency Operations Facility (EOF)
Emergency Telephone Directory Notifications to the State and Counties from the EOF EOF Commodities and Facilities Procedure Emergency Data Transmittal System Access Notifications to the State and Counties from the TSC Core Damage Assessment Activation of the Operations Support Center (OSC)
EOF Access Control Spill Response Procedure Recovery and Reentry Procedure Operations/Engineering Technical Evaluations in the Technical Support Center (TSC)
Public Affairs Emergency Response Plan PALSS Operation for Accident Sampling Rev. 009 Rev. 018 Rev. 018 Rev. 018 Rev. 018 DELETE Rev. 010 Rev. 007 Rev. 004 Rev. 002 Rev. 013 Rev. 006 Rev. 022A DELETE DELETE DELETE DELETE DELETE Rev. 012 Rev. 004 Rev. 014 DELETE Rev. 009 Rev. 002 Rev. 002 I
Rev. 003 DELETED 1
October 23, 2003 Rev. 40
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
TITLE REVISION NUMBER HPIOIBI1009/002 OP101B110091003 HP/0B11009105 HP/OIB/1 009/006 HP/OfB/1009/010 Alternative Method for Determining Dose Rate Within the Reactor Building Recovery Plan Initial Evaluation of Protective Action Guides Due to Abnormal Plant Conditions Procedure for Quantifying High Level Radioactivity Releases During Accident Conditions Releases of Radioactive Effluents Exceeding Selected Licensee Commitments Rev. 002 Rev. 004 DELETED Rev. 006 Rev. 006 HP/I/B/1009/015 HP/21B/1 009/015 HP/0/B110091016 HP/OIB/1009/020 HP/OIB/1009/021 Unit I Nuclear Post-Accident Containment Air Sampling System Operating Procedure Unit 2 Nuclear Post-Accident Containment Air Sampling System Operating Procedure Distribution of Potassium Iodide Tablets in the Event of a Radioiodine Release Manual Procedure for Offsite Dose Projections Estimating Food Chain Doses Under Post-Accident Conditions DELETED DELETED Rev. 003 DELETED Rev. 001 HP/0/B/1009/022 H-P10/1B/1009/023 HO/OB/1009/024 HP/OIB/1 009/029 SH/0/B/2005/001 SH/10/13/2005/002 SRJOJB/2000/001 SRIO/B/2000/002 SRJOIB/2000/003 SRIOIB/2000/004 Accident and Emergency Response Environmental Monitoring for Emergency Conditions Personnel Monitoring for Emergency Conditions Initial Response On-Shift Dose Assessment Emergency Response Offsite Dose Projections Protocol for the Field Monitoring Coordinator During Emergency Conditions Standard Procedure for Public Affairs Response to the Emergency Operations Facility Standard Procedure for EOF Services Activation of the Emergency Operations Facility Notification to States and Counties from the Emergency Operations Facility Rev. 003 Rev. 005 Rev. 002 Rev. 007 Rev. 002 Rev. 002 Rev. 004 Rev. 003 Rev. 010 Rev. 006 2
October 23, 2003 Rev. 40
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
McGuire Site Directive 280 EP Group Manual MNS RP Manual:
PTIO/A/4600/088 TITLE REVISION NUMBER Site Assembly/Accountability and Evacuation/Containment Evacuation Section 1.1 Emergency Organization Section 18.1 Accident and Emergency Response Section 18.2 Environmental Monitoring for Emergency Conditions Section 18.3 Personnel Monitoring for Emergency Conditions Section 18.4 Planned Emergency Exposure Functional Check of Emergency Vehicle and Equipment DELETED Rev. 018 DELETED DELETED DELETED DELETED Rev. 007 3
October 23, 2003 Rev. 40
VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO EACH USE Nuclear Policy Manual - Volume 2
'PPENDIX F. 703. PROCEDURE CHANGE PROCESS RECORD NSD 703 (R04-03)
Duke Power Company CEDURE CHANGE PROCESS RECORD
- 1)
ID No. iRi/-I7O,12-If, iq 6; Revision No. 2 2 Change No. -/
- 2)
- 3)
Station: #u A /cl t
(!~ ~a 5 p eR estricted to _
Station:
T74i1ctGUlArt e:
&-dexe 7756&
C Procedure
Title:
A§CI7*h of-4eaC h
1Wf
>vCr
- 4)
Section(s)ofProcedure Aflected: aidd#5#rL 9,3
- 5)
Requires NSD 228 Applicability Determination? If Applicability Determination is required, attach NSD 228 documentation.
O Yes (Major procedure change)
A No (Minor procedure change)
- 6)
Descriptionorclhange: (Atrachadditionalpages ifnecessary.)
In 6, zo-dd 1 e' '
ft X
eG Od Sq/tfkr 'n fL14-A c:ieo 7, C1b/
g
?¢dw-U+> aUC_ J
<zK6So~ftC'O"'1 cbde C" 9/f
-'~~~~~~~~-I Sov 4bf t
-4C
- 7)
Reason for Change: i
/
gd t
4f C of { sffo>
g;z {9 o (/e5si Av' i 6 Q!5 L
J4 '.- beyiC 74avttSz A ~g
- 8)
Prepared By Date
- 9)
Reviewed By a
(QR)
Date /
3/ )3 Cross-DisciplinarrReview By _(QR)
NA L Date ___
Reactivity Mgmt. Review By (QR) NA Date pO/z7V/o Mgmt. Involvement Review By (Ops. Supt.) NA Date yz3/O V
- 10)
Additional Reviews Reviewed By Date Reviewed By Date
- 11)
Temporary Approval (if necessary)
By (OSMIQR)
Date By A o (QR)
- 12)
Approved By
/
Date Date/0-23-593 REVISION 24 VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO EACH USE 51
tRO4-01)
Duke Power Company (1) ID No. RP/0/A/57001012 PROCEDURE PROCESS RECORD Revision No. 022 PREPARATION (2) Station A1CGU`RE NUCLEAR STATION
\\_S3)
Procedure Title Activation of the Tcchnical Support Center (TSC)
(4) PreparedBy 6'
7
(-
4.
(5) Requires NSD ?('Applicability Determination?
]q Yes (New procedure or revision with major changes) o No (Revision with minor changes) o No (To inco rale previouly approved changes)
(6) Reviewed By d Cross-Disciplinary Review By Reactivity Mgmt. Review By Mgmt. Involvement Review By (7) Additional Reviews Reviewed By Reviewed By (8) Temporary Approval (if necessary)
Date y _ /g c?
(QR)
(QR)
(QR)
(Ops Supt.)
Date NA He Date NA Dale NA Date 7 zLfl 1~
7 I / 0 Date Date By (OSM/QR)
Date By (QR)
Date
-19)
ApprovedBy Date PERFORMANCE (Compare with Control C y e'ery 14 calendardays while work is being performed.)
(10)Compared with Control Copy Date Compared with Control Copy Date Compared with Control Copy Date (I I)Date(s) Performed
'Work Order Number (WOU)
COMPLETION (12)Procedure Completion Verification o Yes 0 NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?
o Yes 0 NA Required enclosures attached?
o Yes [ NA Data sheets attached, completed, dated, and signed?
o Yes 0 NA Charts, graphs. etc. attached dated, identified, and marked?
o Yes 0 NA Procedure requirements met?
Verified By Date (13)Procedure Completion Approved Date (14)Remarks (Attach additionalpages, if necessary)
Duke Power Company McGuire Nuclear Station Activation of the Technical Support Center (TSC)
Reference Use Procedure No.
RPIO/A/57001012 Revision No.
022 Electronic Reference No.
MC0048MF
RPIOIA/5700I012 Page 2 of 5 Activation of the Technical Support Center (TSC)
- 1. Symptoms Conditions exist where events are in progress or have occurred which indicate a potential degradation of the level of safety of the plant and activation of the Emergency Response Organization (ERO) has been initiated.
NOTE:
If the emergency situation prevents activating the TSC within 75 minutes of declaration, the Control Room will:
turn over responsibility for classification and notification (state and county) to the EOP.
maintain responsibility for NRC Event Notification until relieved by the NRC Communicator in the TSC.
^
maintain responsibility for continuous phone communications to the NRC until relieved by the NRC Communicator in the TSC.
- 2. Immediate Actions None
- 3. Subsequent Actions NOTE:
This procedure is not intended to be followed in a step-by-step sequence. Sections of the procedure are to be implemented as the applicable action becomes necessary.
3.1 The TSC is required to be activated for an ALERT, SITE AREA EMERGENCY, or GENERAL EMERGENCY declaration. It may also be activated for an UNUSUAL EVENT if deemed necessary by the Operations Shift Manager/Emergency Coordinator.
3.2 The TSC must be activated within ONE (1) HOUR AND 15 MNWUTES (75 MINUTES) of an ALERT, SITE AREA EMERGENCY, or GENERAL EMERGENCY declaration.
This time frame must be met anytime it is deemed necessary to activate the TSC.
3.3 Upon notification to activate, the Station Manager or designee shall report and notify Operations Shift Manager in the Control Room of arrival.
3.3.1 Personnel in the Emergency Response Organization (ERO) assigned to the TSC shall report to the facility upon notification to activate.
Rev. 22
RPIO/AI5700/01 2 Page 3 of 5 3.3.2 The initial responders shall be responsible for completing their appropriate group enclosures and reviewing their Operational Responsibilities where provided.
3.4 Each represented group is responsible for ensuring their appropriate initial checklist is completed.
3.5 The following definitions are applicable to the Emergency Notification Form for "Plant Condition":
Degrading: Plant conditions involve at least one of the following:
Plant parameters (ex. temperature, pressure, level, voltage, frequency) are trending unfavorably away from expected or desired values AND plant conditions could result in a higher classification or Protective Action Recommendation (PAR) before the next follow-up notification.
Environmental site conditions (cx. wind, ice/snow, ground tremors, hazardous/toxic/radioactive material leak, fire) impacting plant operations or personnel safety are worsening AND plant conditions could result in a higher classification or Protective Action Recommendation (PAR) before the next follow-up notification.
Improving: Plant conditions involve at least one of the following:
Plant parameters (ex. temperature, pressure, level, voltage, frequency) are trending favorably toward expected or desired values AND plant conditions could result in a lower classification or emergency termination before the next follow-up notification.
Environmental site conditions (cx. wind, ice/snow, ground tremors hazardous/toxic/radioactive material leak, fire) have become less of a threat to plant operations or personnel safety AND plant conditions could result in a lower classification or emergency termination before the next follow-up notification.
Stable: Plant conditions are neither degrading nor improving.
Rev. 22
RPIO/AI5700I012 Page 4 of 5 3.6 The following definition is applicable to the Emergency Notification Form, item 10.
Emergency Release: Any unplanned, quantifiable discharge to the environment of radioactive effluent ATTRIBUTABLE TO A DECLARED E MIERGENCY EVENT.
A release is considered to be in progress if any one or more of the following occurs:
Reactor Building EME monitors reading indicate an increase in activity (McGuire 38, 39, or 40).
OR Containment High Range EMIF monitors reading greater than 1.5 Rlhr. (McGuire 51A or 51B).
AND Pressure inside the containment building is greater than Tech. Spec. (McGuire 0.3 psig).
OR An actual containment breach is determined.
Increase in activity monitored by Unit Vent EMP (McGuire 35, 36, or 37).
Steam generator tube leak monitored by EMF (McGuire 33).
Field Monitoring Team results.
Knowledge of the event and its impact on system operation and resultant release pathways. {PIP M-03-0688, C.A.8) 3.7 Upon termination of the drill/emergency, the Emergency Coordinator/designee shall assume responsibility for ensuring the proper resolutions to all completed copies of the McGuire Operations Configuration Control Card(s) prior to the TSC/OSC being deactivated. The Emergency Coordinatorldesignee shall have overall responsibility for ensuring all cards are properly resolved or items logged prior to plant turn-over to the Operations Shift Manager. Once the items/cards have been properly resolved, the TSCIOSC may be deactivated. All completed cards shall be filed by Emergency Planning with other drill/emergency paperwork.
Rev. 22
RP/01A15700101 2 Page 5 of 5
- 4. Enclosures 4.1 Emergency Coordinator TSC Activation Checklist 4.2 Assistant Emergency Coordinator TSC Activation Checklist 4.3 Radiation Protection Manager TSC Activation Checklist 4.4 Offsite Dose Assessor TSC Activation Checklist 4.5 Offsite Agency Communicator TSC Activation Checklist 4.6 NRC Communicator TSC Activation Checklist 4.7 Reactor Engineer TSC Activation Checklist 4.8 Operations Manager in the TSC Activation Checklist 4.9 Operations Procedure Support TSC Activation Checklist 4.10 System Engineering Manager TSC Activation Checklist 4.1 1 Emergency Planner TSC Activation Checklist 4.12 Status Coordinator TSC Activation Checklist 4.13 LAE Communications TSC Activation Checklist 4.14 Operations Manager in the Control Room Activation Checklist 4.15 Data Coordinator TSC Activation Checklist 4.16 Site Assembly Coordinator TSC Activation Checklist 4.17 Emergency CoordinatorTurnover Checklist {PIP M-02-6113, C.A. 13) 4.18 Emergency Classification Termination Criteria 4.19 Fitness For Duty Questionnaire 4.20 Site Evacuation Coordinator TSC Activation Checklist 4.21 Establishing Communications Links Between SAMG Evaluators Rev. 22
.1 EMERGENCY COORDINATOR TSC ACTIVATION CIIECKUST RPIOIA/5700I01 2 Page I of 7 INTIAL NOTE:
You are only required to complete Enclosure 4.19 (Witness for Duty Questionnairc) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
NOTE:
The TSC Status Coordinator will maintain the official TSC log. The following step may be N/A'd.
ESTABLISH a log of activities.
NOTIFY the Operations Shift Manager in the Control Room of arrival.
NOTE:
If a classification change is recognized during turnover, the turnover should not be completed until after the Control Room declares and transmits the notification to the offsite agencies. {PIP-M.-0-00541)
IFnearing the 75-minute activation requirement and an upgrade in emergency classification is recognized, THEN suspend turnover and allow the activated facility to declare and transmit the upgrade. {PIP-M-00-00541 )
RECEIVE turnover from the Control Room as soon as practical utilizing Enclosure 4.17.
Rev. 22
.1 RP/01A/57001012 EMERGENCY COORDINATOR Page 2 of 7 TSC ACTIVATION CHECKMST ASSURE, prior to declaring TSC activated:
- 1. The following TSC positions as a minimum are filled and prepared to assume their function:
- Emergency Coordinator Offsite Dose Assessor Offsite Agency Communicator (2)
NRC Communicator Reactor Engineer.
- 2. Less than the above listed minimum TSC positions are filled, AND
- The 75-minute activation requirement is near, AND An extra person(s) is available whom the EC believes is capable of filling a missing position(s),
AND An appropriate log entry is made. (PJP-M-00-00541)
IF a site assembly is in progress, or is conducted, THEN swipe your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.(PIP 0-M96-1869)
CONDUCT a Time Out prior to activating the TSC.
DECLARE the TSC activated and announce the following via the TSCIOSC public address system: This is
. I am the Emergency Coordinator. The TSC is officially activated as of
. The plant status is as follows:
OR "This is
. I am the Emergency Coordinator. The TSC is officially activated as of
. I will give an update in minutes."
Rev. 22
.1 EMERGENCY COORDINATOR TSC ACTIVATION CIHECKLiST RP/0IAI5700/0I 2 Page 3 of 7 ANNOUNCE over the TSC/OSC public address system the following:
"Anyone who is reporting to this facility outside of your normal work hours and has consumed alcohol within the past five (5) hours, notify either the Emergency Coordinator in the TSC or the OSC Coordinator in the OSC."
NOTE:
The following step should be repeated following each shift turnover.
ANNOUNCE to TSC a reminder to complete a "Work Hour Extension Form" if applicable.
(PIP 0-M98-2099)
ANNOUNCE to TSC to synchronize all time pieces to the satellite time display. {PIP M 5037)
TURN OFF the plant page volume in TSC.
DISCUSS with the Radiation Protection Manager any radiological release or offsite radiological concerns.
ANNOUNCE over the TSC/OSC Public Address System the following if a release has occurred:
Assume areas are contaminated until surveyed by RP.
No eating or drinking until the TSC and OSC are cleared by RP.
NOTE:
- 1. Evacuation will be coordinated by the Site Assembly/Site Evacuation Coordinator if the TSC is activated. Evacuation will be conducted according to RP/O/AI5700/01 I.
- 2. Evacuation will be conducted by the Operations Shift Manager if the TSC is not activated. Evacuation will be conducted according to RP/0/A/5700/01 1.
EVALUATE with TSC personnel and the Radiation Protection Manager the need to conduct evacuation at this time based on the following criteria.
Alert-determine by actual plant conditions.
Site Area Emergency-consider evacuation/relocation of non-essential personnel.
General Emergency-evacuate all non-essential personnel.
NOTIFY EOF anytime personnel are relocated onsite or evacuated from the premises.
Rev. 22
.1 EMERGENCY COORDINATOR TSC ACTIVATION CHECKLIST RPIO/A/5700I01 2 Page 4 of 7 REQUEST all TSC and OSC Managers to have FAXED to the OSC the name, social security number and RP badge number of any person(s) who may be left onsite after evacuation of non-essential personnel but are located in an area other than the OSC.
Rev. 22
.1 RP/01A157001012 EMERGENCY COORDINATOR Page 5 of 7 TSC ACTIVATION CHIECKLIST NOTE:
If changes to the Initial Protective Action Recommendations are recognized and approved Yt.J by the Emergency Coordinator, these changes shall be transmitted to the off site agencies within 15 minutes. {PIP-M-00-02138)
UPON declaration of a General Emergency the Emergency Coordinator shall IMMEDIATELY RECOMMEND to offsite authorities the following:
IF containment radiation levels exceed the levels on Enclosure 4.4, page 5 of 6, Guidance for Determination of Gap Activity, THEN:
Evacuate the 5-mile radius AND 10 miles downwind as shown on Enclosure 4.4, top of page 4 of 6, Protective Action Zones Determination, using wind direction.
AND Shelter remaining zones as shown on Enclosure 4.4, top of page 4 of 6, Protective Action Zones Determination, using wind direction.
IF containment radiation levels DO NOT exceed the levels on Enclosure 4.4, page 5 of 6, Guidance for Determination of Gap Activity, THEN perform one of the following:
IF wind speed is less than or equal to 5 MPH THIEN:
Evacuate zones L, B, M, C, N, A, D, 0, R.
AND Shelter zones E, F, G, H, 1,3, K, P. Q, S.
OR IF wind speed is greater than 5 MPH THEN:
Evacuate the 2-mile radius AND 5 miles downwind as shown on Enclosure 4.4, bottom of page 4 of 6, Protective Action Zones Determination, using wind direction.
AND Shelter remaining zones as shown on Enclosure 4.4, bottom of page 4 of 6, Protective Action Zones Determination, using wind direction.
Rcy. 22
.1 EMERGENCY COORDINATOR TSC ACTIVATION CHECKLIST RPIO/AI5700/01 2 Page 6 of 7 DIRECT the Assistant Emergency Coordinator to FAX the turnover checklist (Enclosure 4.17) to the EOFDirector (if time and situation permit). {PIP-0-M9741 12)
NOTE:
If a classification change is recognized during turnover, the turnover should not be completed until after the TSC declares and transmits the notification to the offsite agencies. { PIP-M-00-0054 1 )
CONDUCT turnover to the EOF Director (EOFD) utilizing Enclosure 4.17.
[NOTE:
Provide periodic updates to the EOFD concerning plant status and request EOFD to provide assessment and field monitoring data on a periodic basis.
REQUEST the NRC Communicator to notify the NRC the EOF is activated.
ANNOUNCE to the TSC and OSC the EOF is activated.
ENSURE ALL completed copies of the McGuire Operations Configuration Control Cards are properly resolved prior to deactivation of the TSC/OSC.
IF the TSC becomes environmentally uninhabitable due to radiological or other conditions and the Control Room remains secure (habitable), THEN:
SELECT individuals to move inside the Control Room or to alternate facilities.
INSTRUCT all other TSC personnel to go to the EOF.
IF the Control Room also becomes uninhabitable due to radiological or other conditions, THIEN:
INSTRUCT TSC personnel to report to the alternate TSC, the Simulator at the Training and Technology Center, or the EOF (select the most appropriate site).
CONDUCT a 'Time-out", approximately every thirty (30) minutes, with the TSC staff to obtain current plant status. Ensure the OSC is aware of when "Time-outs" will take place.
ENSURE all unnecessary communications are put on hold during "Time-outs". (PIP 0-M95-01 60)
ESTABLISH priorities.
ANNOUNCE immediately, to the TSC and OSC, any emergency classification changes, including classification changes made by the EOF. (PIP M-02-2562, C.A. I1).
Rev. 22
.1 RPIDIA/57001012 EMERGENCY COORDINATOR Page 7 of 7 TSC ACTIVATION CHECKUST ANNOUNCE, following time out, to the TSC and OSC the emergency classification, plant status, and priorities via the TSC/OSC public address system.
ESTABLISH a Recovery Organization PER (RP10/A157001024, Recovery and Reentry Procedure) once the Emergency has been terminated. This applies primarily to Site Area Emergency and General Emergency classifications. Refer to Enclosure 4.18 for Termination Criteria.
SERVE as Lead Decision Maker upon entry into Severe Accident Management Guidelines (SAMG).
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.2 RP/01A157001012 ASSISTANT EMERGENCY COORDINATOR Page I of I TSC ACTIVATION CHECKLIST P-IAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.(PIP 0-M96-1869)
NOTE:
The TSC Status Coordinator will maintain the official TSC log. The following step may be N/A'd.
ESTABLISH a log of activities.
OBTAIN time out forms from the procedure cabinet.
ASSIST the Emergency Coordinator in gathering information to facilitate the activation of the Technical Support Center.
FAX turnover checklist (Enclosure 4.17) to the EOF Director when directed by the Emergency Coordinator. (PIP-O-M97-41 12)
ACT as a receiver of information when the Emergency Coordinator is unavailable and relay the information to the Emergency Coordinator in a timely manner.
PROACTIVELY seek information when the Emergency Coordinator is in a reactive mode.
MAKE face-to-face confirmation of information provided when the Emergency Coordinator is unavailable.
ASSIST in making decisions on emergency classifications, mitigation strategies, contingency plans and protective actions for plant personnel and the general public.
ASSIST Emergency Coordinator as a Decision Maker upon entry into Severe Accident Management Guidelines (SAMG).
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22 3
RP/lOA/5700/012 RADIATION PROTECTION MANAGER Page 1 of 4 TSC ACTIVATION CHECKLIST INITIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
ENSURE all Radiation Protection personnel reporting to the TSC also sign the attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{ PIP 0-M96-1 869)
ESTABLISH a log of activities.
ESTABLISH communications with RP personnel in the OSC, Shift Lab and EOF using the cell phone, dial 4980. (Let it ring until you hear a beep. This connects you to the bridge line.)
COMMUNICATE through Emergency Coordinator that dosimetry is required and a dose card shall be filled out if necessary (drill RWP is 33). {PIP 0-M94-1495)
DISCUSS the following with Emergency Coordinator:
- 1) Any release in progress including dose rates (especially at the site boundary).
- 2) Field Team status/data.
- 3)
Onsite radiological concerns.
ESTABLISH contamination control in the TSC, OSC and Control Room as necessary.
- 1. COMMUNICATE through the Emergency Coordinator that frisking of hands and feet is required prior to entry. IPIP 0-M94-1495)
Rev. 22
.3 RP/O/A/5700/012 Page 2 of 4 RADIATION PROTECTION MANAGER TSC ACTIVATION CHECKLIST NOTE:
Do not N/A the following step, even if there has been no release of Iodine. A log entry must be made concerning this required evaluation for drill matrix documentation purposes.
EVALUATE the need to administer Potassium Iodide to emergency workers on site and to Field Monitoring teams in accordance with HP/O/B/1009/016.
MAKE a log entry describing the Potassium Iodide evaluation and subsequent decisions. (PIP M-99-5031)
EVALUATE with the Emergency Coordinator the need to:
- 1) Move any Assembly Points in the release path (include Site Evacuation Coordinator).
- 2)
Conduct site and/or area evacuation (include Site Evacuation Coordinator).
- 3) Recommend protective actions for emergency workers.
- 4) Recommend protective actions for the public.
A LI EVPXLQefl1e At-bN newc8 I
"o acdm tr(9 C>ypeCCX~orxs Clue-, 1-nsd\\_
~~~
i v4~I Rev. 22
.3 RP/O/A/5700101 2 Page 3 of 4 RADIATION PROTECTION MANAGER TSC ACTIVATION CHECKLIST kUj NOTE:
IF changes to the Initial Protective Action Recommendations are recognized and approved by the Emergency Coordinator, these changes shall be transmitted to the off site agencies within 15 minutes. {PIP-M-00-02138)
UPON declaration of a General Emergency the Emergency Coordinator shall IMMEDIATELY RECOMMEND to offsite authorities the following:
IF containment radiation levels exceed the levels on Enclosure 4.4, page 5 of 6, Guidance for Determination of Gap Activity, THEN:
Evacuate the 5-mile radius AND 10 miles downwind as shown on Enclosure 4.4, top of page 4 of 6, Protective Action Zones Determination, using wind direction.
AND Shelter remaining zones as shown on Enclosure 4.4, top of page 4 of 6, Protective Action Zones Determination, using wind direction.
IF containment radiation levels DO NOT exceed the levels on Enclosure 4.4, page 5 of 6, Guidance for Determination of Gap Activity, THEN perform one of the following:
IF wind speed is less than or equal to 5 MPH THEN:
Evacuate zones L, B, M, C, N, A, D, 0, R.
AND Shelter zones E, F, G, H, I, J, K, P, Q, S.
OR IF wind speed is greater than 5 MPH THEN:
- Evacuate the 2-mile radius AND 5 miles downwind as shown on Enclosure 4.4, bottom of page 4 of 6, Protective Action Zones Determination, using wind direction.
AND Shelter remaining zones as shown on Enclosure 4.4, bottom of page 4 of 6, Protective Action Zones Determination, using wind direction.
Rev. 22 3
RP/IOAI5700/012 Page 4 of 4 RADIATION PROTECTION MANAGER TSC ACTIVATION CHECKLIST IF SAMGs are implemented AND offsite releases approach, or exceed, lRem TEDE or 5 Rem Thyroid CDE, TIEN notify the TSC Lead SAMG Evaluator. { PIP-M-99-5381)
NOTE:
For assistance in determining dose rates inside the plant during a SAMG event, contact NGO Nuclear Radiological Engineering Group. { PIP-M-00-1 572)
IF a situation, which is immediately hazardous to life or valuable property, exists, THEN evaluate potential dose rates by one of the following methods:
2.
2.
Contact RP shift at Ext. 4282.
Assess area monitors.
AND Ensure a Request for Emergency Exposure is completed in the OSC prior to dispatch of emergency workers.
REVIEW RPIO/AI5700I000 (Classification of Emergency) criteria (EMIs, offsite dose, etc.) for emergency classification changes and discuss with OPS Procedure Support position.
ENSURE all TSC personnel are wearing dosimetry and using dose cards (RWP 33).
ENSURE responders are aware of the need for frisking prior to entry into the TSC as conditions dictate.
PREPARE for 24-hour coverage as necessary.
DETERMINE if persons with special radiological exposure limits need to be evacuated (e.g.,
declared pregnant women, people with radio-pharmaceutical limitations).
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.4 RP/0/A/5700/012 OFFSITE DOSE ASSESSOR Page I of 6 TSC ACTIVATION CHECKLIST INITIAL
}11P M-02-6113, C.A. 38)
NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm. {PIP 0-M96-1869)
_ ESTABLISH a log of activities.
TURN ON dose assessment and data acquisition computers and acquire necessary information. Plant data used for offsite dose projections is found in Group Display, ERORD5. If data acquisition programs are unavailable, information may be obtained from SDS or the Control Room (EMF and Met data). IPIP M-02-2412, C.A. 16)
OBTAIN copies of the following procedures:
RP/IOA/5700/000 (Classification Of Emergency).
S110/B12005/001 (Emergency Response Offsite Dose Projections).
_ IF a loss of power, LAN, printer, etc., occurs, TIIEN perform Dose Calculations via the Lap Top Computer PER instructions on page 6 of 6 of this enclosure.
NOTE:
Be aware of the effects of loss of power on critical EMFs.
_ VERIFY operability and validity of EMIs through the Shift Lab.
_ VERIFY effluent discharge alignment with Shift Lab, RPM, or RP Support as necessary.
_ VERIFY the status of on-shift Dose Assessment with the shift lab and accept responsibility for dose assessment.
Rev. 22 A
RPIO/A/57001012 OFFSITE DOSE ASSESSOR Page 2 of 6 TSC ACTIVATION CHECKLIST IF the TSC is not activated and the EC has not received turnover from the Control Room, THIEN:
Establish contact with and inform the OSM that the Duty Dose Assessors in the TSC have assumed responsibility for Dose Assessment AND Provide offsite dose calculations and resultant protective action recommendations for radioactive material release to the OSM until the TSC is activated.
ESTABLISH communications with dose assessment personnel at the EOF. Compare information, projections and strategies with the EOF. Turn over dose assessment for offsite communication purposes to EOF Dose Assessors as soon as the EOF becomes officially activated.
CHECK operability of the HIPN telephone by listening for a dial tone. If no dial tone is heard, notify the lAE Communications Specialist to pursue repairs. {PIP-M-99-3800)
RETAIN all computer printouts or manually calculated enclosures.
TURN ON the EMIs (54A and 54B) in the TSC from the OAC computer room by pressing the start button on each EMF control.
ENSURE EMM22 (TSC Area Monitor) is functional.
NOTE:
If a safety injection has occurred, the TSC air intakes sampled by EMF-54A and 54B will open and the filter train is placed in service. One of the air intakes must be reopened if both EMFs are in trip 2.
{PIP 0-M974278)
IF EMF54A and 54B exceed the trip 2 setpoint, TMEN raise the trip 2 setpoint on the lowest reading EMF to reopen the air intake.
PERFORM offsite dose projections and determine protective action recommendations. Dose projections shall be run at least every 30 minutes or as directed by the RPM.
Rev. 22
.4 RP/O/AI5700/01 2 Page 3 of 6 OFIFSITE DOSE ASSESSOR TSC ACTIVATION CHECKLIST F-TE:
If changes to the Initial Protective Action Reconmmendations are recognized and approved by the K>
Emergency Coordinator, these changes shall be transmitted to the offsite agencies within 15 minutes.
(PIP-M-00-02138)
UPON declaration of a General Emergency, IMMEDIATELY RECOMIAIEND to offsitc authorities the following:
IF containment radiation levels exceed the levels on Enclosure 4.4, page 5 of 6, Guidance for Determination of Gap Activity, THEN:
Evacuate the 5-mile radius AND 10 miles downwind as shown on Enclosure 4.4, lop of page 4 of 6, Protective Action Zones determination, using wind direction.
AND Shelter remaining zones as shown on Enclosure 4.4, top of page 4 of 6, Protective Action Zones Determination, using wind direction.
IF containment radiation levels DO NOT exceed the levels on Enclosure 4.4, page 5 of 6, Guidance for Determination of Gap Activity, THEN perform one of the following:
IF wind speed is less than or equal to 5 MPH THEN:
Evacuate zones L, B, M, C, N, A, D, 0, R.
AND Shelter zones E, F, G, II, 1, J, K, P, Q, S.
OR IF wind speed is greater than 5 MPH T]IHEN:
Evacuate the 2-mile radius AND 5 miles downwind as shown on Enclosure 4.4, bottom of page 4 of 6, Protective Action Zones Determination, using wind direction AND Shelter remaining zones as shown on Enclosure 4.4, bottom of page 4 of 6, Protective Action Zones Determination, using wind direction.
ENSURE EMIF54A and B are secured after drill/event is terminated.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.4 RPI0/A/570010 12 Page 4 of 6 OFFSITE DOSE ASSESSOR TSC ACTIVATFON CHECKLIST Protective Action Zones Determiination K)
For Containment Radiation Levels Exceeding GAP Activity Wind Direction (deg from N)
Chart Recorder IEEBCR9100 Point # 8 Average Upper Wind Evacuate Direction {PIP 0-M98-3522) 5 Mile Radius-10 Mile Downwind Shelter 0-22.5 L,BM,C,N,A,D,O,R,E,SF GH,IJ,K,P,Q 22.6 - 45.0 L,BM,C,NA,D,OR,E,Q,S FG,11,lJ,K,P 45.1 - 67.5 L,B,M,C,N,A,D,O,R,E,Q,S FG,11,I,J,K,P 67.6 - 90.0 L,BMC,NAD,OR,P,Q,S EX,,G,11,1,],K 90.1 - 112.5 L,B,MC,N,AD,O,R,K,P,Q,S E,F,G,H,I,j 112.6-135.0 L,B,M,CN,A,D,O,R,I,K,P,Q,S E,FG,11,J 135.1-157.5 L,B,M,C,NAD,O,R,I,K,P,Q EFG,1i,],S 157.6-180.0 L,B,M,C,N,A,D,OR,IJK,P EF,G,HIQ,S 180.1 - 202.5 L,B,M,C,N,A,D,O,R,G,11,IJ,K,P EJ--Q,S 202.6-225.0 L,B,M,C,N,AD,O,R,G,1,lJK,P E,FQ,S 225.1 -247.5 L,BM,CN,A,D,O,RF,G,1l,l, E,KP,Q,S 247.6 - 270.0 L,B,M,C,N,A,D,O,R,rG,Hjl,l E,K,P,Q,S 270.1 - 292.5 LB,M,CNA,D,O,R,E,,G,Il,J 1,K,PQ,S 292.6-315.0 L,B,M,C,N,A,D,O,R,E,1F,G
}31,1J,K,PQ,S 315.1 -337.5 L,B,M,C,N,AD,O,R,E,rG IJ,1,J,K,P,Q,S 337.6-359.9 L,B,M,CN,A,D,O,RE,F,S G,11,lJ,K,P,Q Wind Speed Greater than 5 Miles per Hour ind Direction (deg from N)
Chart Recorder IEEBCR9 100 Point # 8 Average Upper Wind Evacuate Direction(PIP 0-M98-3522) 2 Mile Radius-5 Mile Downwind Shelter 0-22.5 L,B,M,CD,O,R A,E,F,G,H,IJ,K,NP,Q,S 22.6 -45.0 L,B,M,CD,OR AE,:,G,l3,]XK,NP,Q,S 45.1 - 67.5 L,B,M,CD,OR A,E,F,G,llJ,K,N,P,Q.S 67.6 - 90.0 LB,M,CD,O.R,N AEFGJIIJ.KP,QS 90.1-112.5 LB,M,C,O,R,N A,DE,F,G,H,I,1,K,P,Q,S 112.6-135.0
,BMCONRA DEFGJI,IJ,K,P,Q,S 135.1-157.5 L,B,M,C,O,A,N D,EF,G,H,I,J.K,P,Q,R,S 157.6-180.0 L,B,M,C,A,N D,E,F,GH,,J,K,O,P,Q,R,S 180.1-202.5 LBM,CAN DEFG.HI,1]JK,O,P,Q,R,S 202.6-225.0 LB,MCAN,D E,E;G,H,IJ,,K,O,P,Q,R,S 225.1-247.5 LB,M,CA,D EF,G,HI,J,KN,O,P,Q,R,S 247.6-270.0 L,B,M,C,A,D EF,G,H,IJ,KN,OP,Q,R,S 270.1 -292.5 L,BM,C,AD EF,G,H,,1,JK,N,O,P,Q,R,S 292.6-315.0 L,B,M,C,AD EFG,HI,1J,KN,O,P,Q,R,S 315.1-337.5 L,BM,CD,R AEFG,1Ii,J,KNO,P,Q,S 337.6-359.9 L,B,M,C,D,R A,E,:,G,H1,J,KNO,P,Q,S Rev. 22
.4 RP/O/A/5700/012 Page 5 of 6 OFFSITE DOSE ASSESSOR TSC ACTIVATION CHECKLIST GUIDANCE FOR OFFSITE PROTECTIVE ACTIONS GUIDANCE FOR DETERMINATION OF GAP ACTIVITY NOTE:
Fission product inventory inside containment is greater than gap activity if the containment radiation level exceeds the levels in the table below.
IF the OAC is available, call up the following computer points based on need:
Unit I OAC Unit 2 OAC MI A0829 MIA0835 IEMF5IA IEMF51B M2A0829 M2A0835 2EMF5IA 2EMF51B Time After Shutdown (Hours) 0 0-2 2-4 4-8
>8 Containment Monitor Reading (R/HR)
EMiF51A or5 1B
- 2,340 864 624 450 265 Rev. 22
.4 RP10/A/5700/012 OIFSITE DOSE ASSESSOR Page 6 of 6 TSC ACTIVATION CHIECKLIST Oneration of Backup Laptop Computer NOTE:
This computer shall be used only when no other dose assessment computers are functional.
In the TSC Dose Assessment area, open the wall cabinet containing the Raddose Back-up Computer. The key for the wall cabinet is in the Dose Assessment cabinet.
Place laptop on desk under cabinet.
& IF yellow LAN cable is NOT attached to laptop, connect LAN cable to back of laptop.
Turn the laptop on.
WhIEN prompted, press ctrl-alt-delete.
When prompted, enter your user ID and personal domain password.
Perform dose projections in accordance with procedure.
WHEN laptop computer is no longer needed, shutdown computer.
Return laptop to wall storage cabinet.
Rev. 22
.5 RP/0/A/5700101 2 Page 1 of I OFFSITE AGENCY COMMUNICATOR TSC ACTIVATION CHECKLIST INITAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
ISIGN in on the TSC staffing board and put on position badge.
ISIGN the TSC attendance sheet for a drill.
-I IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{PIP 0-M96-1869)
START printer so that it can warm up and be ready to print ENF forms.
TESTABLISH a log of activities.
NOTE:
K).
ANY information sent to the EOF other than ENF FORMS (TSC/EOF Turnover Sheet, SAMG Strategy Sheets, etc.) should be faxed to Fax Machine in EOF Director Area. Fax number 8-382-1825. { PIP 0-M98-2065)
OBTAIN a copy of RP/01A157001018, (Notifications to the State and Counties from the Technical Support Center) from the procedures cabinet.
EXECUTE RP/O/A/5700/018, (Notifications to the State and Counties from the Technical Support Center).
INFORM Emergency Coordinator of status of offsite communications (e.g., next message due).
PREPARE for 24-hour coverage as necessary.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of emergency facility.
Rcv. 22
.6 NRC COMMUNICATOR TSC ACTIVATION CIECKLIST RP/O/A/5700I012 Page 1 Of 2 INITIAL NOTE:
You are only required to complete Enclosurc 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{ PIP 0-M96-1869)
ESTABLISH a log of activities.
OBTAIN a copy of the current classification procedure from the procedure cabinet:
-Notification Of Unusual Event, RP10/A157001001
-Alert, RP101A157001002
-Site Area Emergency, RP10/A15700/003
-General Emergency, RP/O/A/5700/004.
NOTE:
The only turnover from the Control Room the TSC NRC Communicator takes is responsibility for communications to the NRC.{PIP 0-M94-1496)
WHEN the TSC is activated, TllEN pickup and monitor the NRC ENS telephone (Located on NRC Communicator's table). {PIP-M-99-3800)
E iFthe Control Room Communicator is on line with the NRC, inform the parties that the TSC is activated and you are ready to assume continuous communication requirements.
IF continuous communication with the NRC is not established, notify the Control Room Communicator that you are available to perform this function, if required. (PIP-M 3800)
Rcv. 22
.6 RP101A/5700/012 NRC COMMUNICATOR Page 2 of 2 TSC ACTIVATION CHECKLIST IF not previously established, THEN establish continuous communications upon request by the NRC. {PIP-M-99-3800)
INFORM NRC of TSC/EOF activations and plant status as requested.
PROVIDE for 24-hour coverage as necessary.
INFORM the NRC when the TSC is deactivated. This requires an additional call using ENS when the NRC does not require continuous communications to be maintained.
CONTACT Regulatory Compliance Duty Person if the NRC is going to arrive on site.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of (he emergency facility.
Rev. 22
.7 RP101A157001012 REICACTOR ENGINEER Page 1 of 2 TSC ACTIVATION CHECKLIST
-'-MAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{ PIP 0-M96-1 869)
ESTABLISH a log of activities.
OBTAIN a copy of RP/0/A/57001019 (Core Damage Assessment) from the procedure cabinet.
OBTAIN a copy of affected Unit(s) Data Book. {PIP 0-M98-3522)
MONITOR core conditions as appropriate using either APD, SDS or the OAC Critical Points and Steam Tables as follows:
NOTE:
If the OAC is not available, core conditions may need to be obtained from the Operations Manager in the TSC who is in contact with the Control Room.
- 1. Core Subcooling.
- 2.
Reactor Vessel Water Level (RVLIS).
- 3.
Power level if Reactor not tripped.
- 4.
Ask the Operations Liaison to verify all rods at bottom on reactor tripped.
- 5.
Source Range Trends following Reactor Trip.
- 6. Compare each loop T-hot, T-cold and T-avg.
- 7.
What is the most recent boron concentration, and has there been any safety injection?
- 8.
Reactor coolant pumps On/Off Natural or Forced circulation.
- 9.
Pressurizer Level.
- 10. Containment EMPs.
II. Injection flow and letdown flow (NC inventory).
- 12. Containment Pressure.
- 13. Current bumup and previous 2 cycles EFPD.
- 14. The number of failed rods and DEI prior to transient.
- 15. Fuel Pool Temperature (Phase A or Phase B Isolation).
Rev. 22
.7 RP/O/A157001012 REACTOR ENGINEER Page 2 of 2 TSC ACTIVATION CHECKLIST REVIEW the previous parameters with an immediate focus on the trends of the following:
- 1. State of criticality and shutdown margin.
- 2.
Core voiding.
- 3.
Core uncovery.
- 4.
Challenge to the fuel pellet fission product barrier.
- 5.
Challenge to the cladding fission product barrier.
- 6.
Challenge to the NCS pressure boundary.
- 7.
NC cooldown rate.
- 8.
Fuel Pool Heatup.
On a Safety Injection Signal the Auxiliary Building KC cooled loads are isolated by a phase A containment isolation signal. This includes KC cooling of the KF heat exchangers. A conservative estimate of the time for the spent fuel pool to reach saturation without forced cooling is approximately 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />. Within approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> following a loss of forced cooling of the spent fuel pool, contact Accident Assessment (Nuclear Engineering General Office) in the EOF for a recommendation regarding initiating KC cooling to KF or alternate means of supplying fuel pool cooling.
_ PREPARE for 24-hour staffing as necessary.
_ ASSIST Operations Procedure Support as an Evaluator upon entry into Severe Accident Management Guidelines (SAMG).
_ RE ER to Enclosure 4.21 of this procedure for guidance on establishing communications links between SAMG evaluators.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the Emergency facility.
Rev. 22
.8 RP/IOA/5700/0 12 Page 1 of 2 OPERATIONS MANAGER IN THE TSC TSC ACTIVATION CHECKLIST INITIAL IOTE :
You are p
only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarn.{(PIP 0-M96-1869)
ESTABLISH a log of activities.
ESTABLISH communications with the Control Room, OSC and EOF using the cell phone by dialing 4500 (let it ring until you hear a beep).
NOTE:
If a Security event occurs while the TSC is activated, the OPS Manager in the TSC will serve as the focal point for the coordination of activities between the OSC, TSC and Security. The information and actions decided upon should be handled through the normal communication channels with the TSC Emergency Coordinator.
-IIF a Security event occurs (i.e., bomb threat, sabotage, etc.) or additional communications are needed with Security personnel, have the OSC Security Officer request the SAS Security Officer to dial into the OPS bridge line (4500).
NOTIFY the Control Room crew, via the Operations Manager in the Control Room, of any event classification changes. {PIP-M-00-2138)
Rev. 22
.8 RP10_
A/57001012 OPERATIONS MANAGER IN TIE TSC Page 2 of 2 TSC ACTIVATION CHECKLIST IF a loss of OAC occurs, or if for some reason SDS data becomes unavailable in the TSC, select a data taker from the control room crew or some other resource. INSTRUCT the data taker to complete the six page "Loss of OAC Data Collection" checklist kept on file in the TSC procedure file cabinet. (The TSC Emergency Planner also has electronic access to this checklist via "Emgplan on Mnsf2"/"Forms"I"Loss of OAC Data Collection.doc".) SPECIFY to the data taker how frequently this checklist needs to be completed and forwarded to the OPS Manager in the TSC.
FAX number 4722 in the TSC Site Assembly/Evacuation Coordinators' office may be used if deemed necessary for transmittal. PROVIDE copies of the completed checklist to the TSC staff as needed. (PIP M-99-5381)
PROVIDE main communication link between the TSC and Control Room.
_ PROVIDE accurate and current status information to Emergency Coordinator and during time-outs.
ASSIST in making decisions on emergency classifications, mitigation strategies, and contingency plans.
_ SUPPORT Control Room personnel by providing resources and consultation as required.
EVALUATE and prioritize requests for information from the TSC staff, EOF staff, NRC and others.
EVALUATE and consult with Control Room personnel on suggested mitigation strategies.
COORDINATE with the Operations Liaison requested priorities of activities in the plant.
_ IF necessary, OVERRIDE the normal controls on activities directed by the OSC.
_ ASSIST Emergency Coordinator as a Decision Maker upon entry into Severe Accident Management Guidelines (SAMG).
_ PROVIDE all completed paperwork to Emergency Planning upon deactivation of the Emergency Facility.
Rev. 22
.9 RP/O/AJ5700I01 2 Page 1 of 2 OPERATIONS PROCEDURE SUPPORT TSC ACTIVATION CHECKLIST INITIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in (he reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{PIP 0-M96-1869)
ESTABLISH a log of activities.
OBTAIN a copy of RP/0/A/57001000 (Classification of Emergency) from the procedures cabinet.
OBTAIN a copy of the current classification procedure from the procedure cabinet:
-Notification Of Unusual Event, RP/lOA/5700l001
-Alert, RP101A15700/002
-Site Area Emergency, RP/O/A/5700/003
-General Emergency, RP/0/A/5700/004.
OBTAIN a copy of RP101AJ57001026 [Operations/Engineering Required Actions In The Technical Support Center (TSC)] from the procedure cabinet and begin system/plant parameter evaluation.
NOTE:
The following step provides a listen only connection. Leave head set switch in the "mute" position (position is taped).
ESTABLISH communications with OPS bridge line using the cell phone by dialing 4500. (Let it ring until you hear a beep.)
Rev. 22
.9 RP/0 /A157001012 OPERATIONS PROCEDURE SUPPORT Page 2 of 2 TSC ACTIVATION CHECKLIST ENSURE correct emergency classifications are made by following the current plant status and procedures in use.
PROVIDE back-up service to Control Room personnel ensuring the correct procedural flowpath is followed.
ADVISE Emergency Coordinator on the anticipated course of the event.
PREPARE Control Room personnel of possible difficult points in the procedures by a look ahead.
CONSULT the EOF for possible solutions if procedural adequacy becomes a concern.
PROVIDE information to Offsite Agency Communicator and the NRC Communicator as requested regarding changes in plant conditions.
PREPARE for 24-hour coverage as necessary.
SERVE as Lead Evaluator upon entry into Severe Accident Management Guidelines (SAMG).
This duty shall include providing leadership and guidance to the other available SAMG Evaluators specifically conceming what they should be doing. (PIP-M-99-5381)
REFER to Enclosure 4.21 of this procedure for guidance~on establishing communications links between SAMG evaluators.
PROVIDE completed paperwork to Emergency Planning upon deactivation of the Emergency facility.
Rev. 22
.10 RP/IOA/5700I012 Page I of 2 SYSTEM ENGINEERING MANAGER TSC ACTIVATION ChECKLIST INITAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{PIP 0-M96-1869)
ESTABLISH a log of activities.
ENSURE PC is on and displaying plant status.
ESTABLISH communications with the following and provide the SEM phone number:
- TSC Engineering Support, Ext. 4917
NOTE:
The following step provides a listen only connection. Leave head set switch in the "mute" position.
I__ESTABLISH communication with the OPS bridge line, using the cell phone by dialing 4500.
(Let it ring until you hear a beep.)
IOBTAIN a copy of RP/0/A15700/026 [Operations/Engineering Required Actions In The Technical Support Center (TSC)] from the procedure cabinet and begin system/plant parameter evaluation.
EVERIFY Engineering Support Group is connected to the Operations headset network (listen only) after the Operations Manager in the TSC ties in the OSC and EOF.
Rev. 22
.10 RP/O/A/5700/0I2 Page 2 of 2 SYSTEM ENGINEERING MANAGER TSC ACTIVATION CHECKLIST K)__ COORDINATE accident mitigation strategy and engineering support through effective communications with the Engineering Support Group, Accident Assessment in the EOF, and the OSC.
CONTACT the on-duty EP Support Leader and request appropriate duty personnel MSEICEN when outside of normal hours.
CONTINUALLY communicate with TSC personnel, identifying areas needing Engineering support.
REPORT all accident mitigation strategies to the Emergency Coordinator.
ASSIST Operations Procedure Support as an Evaluator upon entry into Severe Accident Management Guidelines (SAMG).
REFER to Enclosure 4.21 of this procedure for guidance on establishing communications links between SAMG evaluators.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.11 RP/01A15700/012 EMERGENCY PLANNER Page I of 4 TSC ACTIVATION ClIECKLIST INITIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm. (PIP 0-M96-1869)
ESTABLISH a log of activities.
ASSIST the Emergency Coordinator as required to achieve a timely turnover to the EOF. (PIP 0-M98-3522)
ESTABLISH communications with EOF Emergency Planner using the cell phone by dialing 8-831-4010, or another available bridge line.
APPRISE Emergency Coordinator of TSC/OSC announcements.
IF Emergency Planning support is needed in the OSC, TIIEN contact additional Emergency Planning personnel and request they respond to the OSC.
SUPPORT Emergency Coordinator activity (e.g., keep in procedure).
PROVIDE support for the activation and operation of the TSC.
PROVIDE necessary NRC/State/County interface.
ASSIST Off-site Agency Communicators in preparation of emergency notifications as needed.
ShARE copy of NRC Notification forms, and Emergency Notification forms with the Status Coordinator. (PIP-0-M-99-091 1)
UPDATE the PARS board to reflect the protective actions identified in item 15 of the Emergency Notification form as each Emergency Notification form is approved.
PROVIDE support to other members of the TSC as requested.
Rev. 22
.11 RP10/A/5700/012 EMERGENCY PLANNER Page 2 of 4 TSC ACTIVATION CHECKLIST PREPARE for 24-hour coverage as necessary.
COMPLETE the 24-h1our TSC Position Staffing Log (page 4 of 4 of this enclosure).
MONITOR the Public Affairs telephone (4520) in TSC and place off hook if requested.
COLLECT all completed procedures and log notes upon deactivation of the emergency facility.
CONTACT the EP Manager to ensure that the appropriate critiques are held with the Offsite Agencies. fPIP-G-00-00209)
ASSIGN an individual from Emergency Planning staff to follow up with an LER or written summary to the State and County authorities within 30 days.
Person assigned responsibility:
RESTORE the TSC and OSC for drills and actual events as follows:
Leave on:
Fax machines ERDS computers in Data Coordinator's Office Cell phones.
Turn off:
All computers (except video conferencing computers and ERDS computers)
Copiers Public address components(except site PA for the TSC)
Projectors.
Rev. 22
.11 RP/O/A/57001012 EMERGENCY PLANNER Page 3 of 4 TSC ACTIVATION CHECKLIST Perform:
Clean tables off Put all trash in containers Wipe down status boards Verify all Fax machines have paper supply replenished.
Verify all copiers have paper supply replenished Rcplenish the following:
Position specific notebooks (I copy of procedure body and minimum 3 copies of applicable enclosures).
Procedure and forms cabinet files per PT/O/A/4600/091, Enclosures 13.1, 13.2, 13.3, 13.4, and 13.5.'
K)
Check TSC and OSC EP and AP notebooks, IF any book(s) seal(s) are broken, THEN notify the Operations Shift Support Technicians.
Rev. 22
.11 RPlIOA/57001012 Page 4 of 4 EMERGENCY PLANNER TSC ACTIVATION CHECKLIST 24-HOUR TSC POSITION STAFIING LOG Primary Relief Position Name
- Shift Name
- Shift Schedule Schedule Emergency Coordinator Assistant Emergency Coordinator Operations Manager in the TSC Operations Manager in the Control Room Operations Procedure Support System Engineering Manager Reactor Engineer l
Radiation Protection
. Manager itaius %uorUInaior vtatus Coordinator Emergency Planner NRC Communicator Site Assembly Coordinator Site Evacuation Coordinator Data Coordinator IAE Communications Offsite Agency Communicator Offsite Agency Communicator l
Offsite Dose Assessor Offsite Dose Assessor
- List hours of coverage: i.e., 0800-2000, or 8am-8pin.
Rev. 22
.12 RP/IOA/5700I012 STATUS COORDINATOR Page I of 5 TSC ACTIVATION CHECKLIST (PIP O-M94-1491)
INrTIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for drills.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{PIP 0-M96-1869)
OBTAIN the remote control for the overhead projector and the electronic message board from the TSC supply cabinet.
lNOTE:
The overhead projector takes several minutes to warm up.
TURN main switch of remote control to ON position (located on right side of remote).
POINT remote to overhead projector and depress power on button.
NOTE:
The following allows the plant status sheet to be viewed in the OSC.
LOG ON the Status Coordinator Computer using your ID and password.
ENSURE computer time is in sync with TSC satellite display.
DOUBLE CLICK on the Plant Status.doc Icon.
MINIMIZE the Plant Status.doc.
START Net Meeting by double clicking on the OSC Status Board Icon. {M-01-4276)
WHEN Net Meeting starts and displays, THEN:
SELECT the tools pull down menu.
SELECT "Sharing".
Rev. 22
.12 RPlO/A/5700I012 STATUS COORDINATOR Page 2 of 5 TSC ACTIVATION CHECKLIST K)>
SELECT "Plant Status.doc" - Microsoft under "Sharing Programs".
CLICK on the "Share" button.
CLOSE the "Sharing Program".
MINIMIZE Net Meeting.
MAXIMIZE Plant Status.doc.
SAVE as current date activation.doc (e.g., 22498 activation.doc).
PRINTOUT plant status sheets after each significant change and prior to announced timeouts.
In the absence of the Emergency Planner, ANSWER the Public Affairs telephone (ext. 4520),
and lay off hook if required.
INPUT classification information on the electronic message board using the remote control as follows:
- 1. To turn "ON": Press Shift and Program simultaneously.
- 2.
To select programmed messages:
- a.
Unusual Event Press Program then Run then "I" then RUN.
- b. Alert Press Program then Run then "2" then RUN.
- c.
Site Area Emergency Press Program then Run then "2" then RUN.
- d.
General Emergency Press Program then Run then "4" then RUN.
- 3.
To Turn "OFF":
Press Shift and Program simultaneously.
ENTER plant/cquipment status as appropriate on electronic document.
Rcv. 22
.12 RP101A/5700/012 STATUS COORDINATOR Page 3 of 5 TSC ACTIVATION CHECKLIST NOTE:
The Emergency Planner is provided copies of all NRC Notification forms and Emergency Notification forms. These may be useful in maintaining the TSC log. {PIP-0-M-99-091 1)
INOTE:
Log errors cannot be deleted.
CORRECT any log errors by making a new entry and stating in the entry that this corrects a previously entered error. {PIP M-02-6113, C.A. 32)
LOG ON to "Auto log" using your logon ID and password.
ESTABLISH a log to serve as official log for TSC as follows:
Record all significant activities.
Record all TSC EC decisions.
Record the time of entry.
List entries in chronological order and include enough detail to reconstruct event series at a later date.
Rev. 22
.12 RP/01A15700/012 STATUS COORDINATOR Page 4 of 5 TSC ACTIVATION CHECKLIST LOG entries should include but arc not limited to the following examples:
- Emergency Coordinator and any change in Emergency Coordinator
- Time at which the TSC is activated.
- Present emergency classification, changes in classification, time of declaration
- Plant Conditions (Unit I and 2):
- Core Cooling information (i.e., Time To Boiling, etc.)
- Safety Systems Degraded
- Power Supply Status
- Fission Product Barrier Degradation
- Radiation Releases.
- Procedures in effect and any transition to another procedure.
- Actions taken that are not a part of an approved procedure.
- Any abnormal or unexpected plant response.
- Major equipment manipulations.
- Major mitigation actions taken.
- Site assembly or evacuation of all or any part of the plant.
- Personnel Injuries.
- Recovery Action(s) in Progress.
- Expected time of next Time-Out.
ENSURE the status board is maintained with current information:
3 or 4 highest priority "recovery actions" set by the Emergency Coordinator.
- relevant plant status information captured under 'Equipment Status."
TRACK established priorities.
PREPARE for 24-hour coverage.
PRINT copy of TSC Autolog.
Rev. 22
.12 RP/01A157001012 STATUS COORDINATOR Page 5 of 5 TSC ACTIVATION CHECKLIST SHUTDOWN computer, monitor and remote control.
RETURN remote controls to supply cabinet.
PROVIDE all completed paperwork (Activation checklist and status board printouts) to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.13 RP/0/A/5700/012 JAE COMMUNICATIONS Page 1 of I TSC ACTIVATION CHECKLIST 1NTIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{PIP 0-M96-1869)
ESTABIAShI a log of activities.
ENSURE all necessary equipment needed to support the TSC is operable.
Video Conferencing v
Phones Faxes Headsets Page System.
IF IAE Communications support is needed in the OSC, THEN contact additional LAE Communications personnel and request they respond to the OSC.
PREPARE for 24-hour coverage as necessary.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.14 RP/0/A/57001012 OPERATIONS MANAGER IN THE Page I of 2 CONTROL ROOM TSC ACTIVATION CHECKLIST U~ INrIIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC Staffing board and put on position badge. (N/A for drills)
SIGN the TSC attendance sheet for a drill.
RECEIVE a verbal report from the OSM detailing plant status, emergency class, and shift staffing level.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the Control Room for personnel accountability. (N/A for drills.)
CONTACT your site assembly point and report your location upon activation of the site assembly alarm. {PIP 0-M96-1869) (N/A for drills.)
ESTABLISH a log of activities.
ESTABLISH communications with the TSC, OSC and EOF using the cell phone by dialing 4500. (Let it ring until you hear a beep.) (Each time a party connects, a beep will be heard.)
E XPEDITE time critical tasks for the OSM by clear communication to the OSC via the OPS Liaison. The OSM is responsible for designating time critical tasks originating from the Control Room. Once a task originating from the Control Room is designated time critical, the OSM, or designee, shall direct the OPS Manager in the Control Room to request the OSC OPS Liaison to immediately make available an operator (or team) from the OSC contingent for prompt dispatch into the plant via hand held radio. Completion of OSC Task Work Sheet paperwork shall not delay time critical task dispatches. Such time critical dispatches shall receive prior verbal approval from the OSC Coordinator. Tirme critical task dispatches originating from the Control Room shall remain under direct control of the Control Room crew until the subject task is complete and the person (or team) has returned to the OSC and completed debriefing. {PIP 0-M96-1576) {PIP 0-M98-3522)
Rev. 22
.14 RP101A15700/012 OPERATIONS MANAGER IN THE Page 2 of 2 CONTROL ROOM TSC ACTIVATION CIIECKLIST PROVIDE main communication link from the Control Room or Simulator to the TSC, OSC and EOF.
PROVIDE accurate and current task status information to the OSM as needed for non-time critical tasks.
ASSIST in making decisions on emergency classifications, mitigation strategies and contingency plans.
SUPPORT Control Room personnel by directing resources and providing consultation as required.
EVALUATE and prioritize for the Control Room requests for information from TSC, OSC, EOF, NRC and others.
EVALUATE and consult with Control Room personnel on suggested mitigation strategies.
COORDINATE with the Operations Liaison requested priorities of activities in the plant.
OVERRIDE normal controls on activities directed by the OSC as necessary.
AFTER the shift NLOs have been dispatched to the OSC, inform the OSM of your responsibility to make NLOs available to the Control Room for time critical tasks as needed.
NOTIFY the TSC OPS Procedure Support position of all Emergency Procedure transitions.
{PIP 0-M97.41 12)
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.15 RP1OIA/5700012 DATA COORDINATOR Page I of 2 TSC ACTIVATION CHECKLIST PEn1AL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the reader located in the TSC for personnel accountability.
CONTACT your site assembly point and report your location upon activation of the site assembly alarm.{PIP 0-M96-1869)
ESTABLISHl a log of activities.
NOTE:
ERDS is not activated for drills unless directed to do so'by Emergency Planning. {PIP-M 561).
ERDS can only be activated / deactivated from designated computer terminals with SDS access.
These are located in the STA's Office, the Data Coordinators' room in the TSC and all within the Control Room horse shoe area.
ERDS is NOT activated for a Notification of Unusual Event. (PIP-0-M-99-2929)
IF the Emergency Response Data System (ERDS) is not activated, THEN activate ERDS as follows:
Ensure SDS is running on the selected terminal.
Click on MAIN.
Click on GENERAL.
Click on ERDS.
Click on ACTIVATE.
Record the date and time ERDS was activated in the log section of the Data Coordinator notebook located at the OAC terminals in the TSC.
Rev. 22
.15 RP/01A157001012 DATA COORDINATOR Page 2 of 2 TSC ACTIVATION CHECKLIST INFORM the OSM that ERDS was activated.
INFORM the EC that ERDS was activated.
IF ERDS failed to activate after five (5) attempts, THEN have the NRC Communicator notify the NRC via ENS or other available means. {PIP-M-99-5381).
_ TERMINATE ERDS once the event is over by clicking on Terminate.
_ PROVIDE support in the area of Computer Services and data acquisition.
_ PROVIDE computer support for both software and hardware applications of data review in the TSC and the transfer of data to offsite locations.
_ PREPARE for 24-hour coverage as necessary.
PROVIDE all completed paperwork to Emergency Planning upon deactivation of the emergency facility.
Rev. 22
.16 RP/O/AI5700I01 2 Page I of4 SITE ASSEMBLY COORDINATOR TSC ACTIVATION CHECKLIST SNIUAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress, or is conducted, SWIPE your ID badge in the badge reader located in the TSC for personnel accountability.
CONTACT your site assembly point, report your location upon activation of the site assembly alarm. { PIP 0-M96-1869)
E STABLISH a log of activities.
E STABLISH! and maintain communications with the SAS by calling Ext. 2191 to obtain status of the site assembly.
INOTE:
Extension 4458 and 4977 are forwarded to Security at 4550 when the TSC is not activated.
U_~
CLEAR the forward feature from extension 4458 and 4977 (located in the Site Assembly Coordinator office) by following the instructions located on the desk.
RECORD site assembly start time _
(announced from Control Room or available through the Operations Manager in the TSC).
NOTE:
Approximately 20 minutes into the site assembly, the assembly locations inside the protected area will contact the Site Assembly Coordinator with names and badge numbers of personnel who were unable to swipe at the assembly locations.
-WHEN Security provides a printout of unaccounted personnel, THEN CHECK OFF personnel who could not swipe at their assembly point (request this from Security about 20 to 25 minutes into the site assembly).
Rev. 22
.16 RPIO/A/5700/012 SITE ASSEMBLY COORDINATOR Page 2 of 4 TSC ACTlVATION CHECKLIST NOTE:
During drills, the number of personnel at each assembly point inside the protected area should be determined only if time permits. This information is necessary in the event of an evacuation.
CONTACT the various site assembly points inside the protected area to determine the approximate number of personnel at each location.
NOTE:
Secure personnel numbers from site assembly points inside the protected area prior to calling outside site assembly points.
During an actual event, CONTACT all site assembly points to determine the approximate number of personnel at each location.
RECORD the approximate number of personnel at each assembly point inside the protected area on the board located in the Site Assembly Coordinators office.
RECORD the approximate number of personnel at each assembly point outside the protected area on the form listing the outside site assembly points (form located in the Site Assembly Coordinator's office).
NOTE:
During a TSC "time out" a Site Assembly or Evacuation Coordinator SHALL report to the designated location at the Emergency Coordinator's Table to provide status/updates. {PIP M98-2065)
RECORD site assembly completion time REQUEST the OPS Manager in the TSC have the Control Room to STOP site assembly alarms and announcements.
DISCUSS standing down from site assembly with the Emergency Coordinator. If okay to stand down, REQUEST OPS Manager in the TSC have the Control Room to give the stand down from site assembly. If NOT okay to stand down from site assembly, Site Evacuation Coordinator will make announcements as directed by Enclosure 4.20.
Rev. 22
.16 RPIO/AI5700/012 SITE ASSEMBLY COORDINATOR Page 3 of 4 TSC ACTIVATION CHECKLIST NOTE:
- 1. The following message will be communicated to the site at the conclusion of site assembly by the control room.
- 2. If there is a need to use the public address system to convey a message to an individual location, refer to page 4 of 4 in this enclosure for the number of the individual location.
IF requested to do so by the control room, ANNOUNCE the stand down message below:
Drill Message for standing down from Site Assembly: Dial 710; at the beep, dial 80, begin speaking "Attention all personnel. This is a drill message. This is a drill message. You have been assembled as part of an emergency exercise. If this were an actual emergency, you would be asked to remain assembled waiting on further information, or given instructions to leave the site in accordance with our site evacuation plan. You may now return to your normal work assignments. Thank you for your participation."
Actual Event Message for standing down from Site Assembly: Dial 710; at the beep, dial 80, begin speaking "Attention all personnel. Conditions have stabilized (or have been downgraded) so that site assembly is no longer required. You may now return to your normal work assignment."
AFTER the drill message for standing down from site assembly is announced, EVALUATE the need to initiate search and rescue of missing personnel and discuss with Emergency Coordinator.
POST periodic site assembly updates on site assembly/evacuation board as needed.
'PROVIDE periodic updates to the Emergency Coordinator, as needed and during time outs, concerning site assembly status.
PREPARE for 24-hour coverage for your position as necessary.
NOTE:
If the Site Assembly portion of the Emergency / Drill is complete. The Site Assembly Coordinator should assist the Site Evacuation Coordinator with Emergency/ Drill message updates and evacuation coordination.
-WHEN the TSC is deactivated, then FORWARD extension 4458 and 4977 to Security at extension 4550.
REPLACE the signs on the extension 4458 and 4977 warning personnel about using the two extensions.
PROVIDE all completed paperwork to the Emergency Planner upon deactivation of the emergency facility.
Rev. 22
.16 SITE ASSEMBLY COORDINATOR TSC ACTIVATION CHECKLIST SITE PAGING SYSTEM INDIVIDUAL PAGING NUMBERS RPIO/A/5700/012 Page4 of 4 NOTE:
- 1. 710 covers all of these areas.
- 2. Call numbers for individual locations are listed below.
71 1 then speak 712, then speak 713, then speak 714, then speak 715, then speak 718, then speak 719, then speak 720, then speak 721 then speak 722, then speak 723, then speak MOC Garage, Switchyard, Firing Range, & Ball field Medical NAB MTE Cowans Ford Plant Island Training Center Island Environmental Center Island Tech Services Center Island Energy Explorium Rev. 22
.17 Emergency Coordinator Turnover Checklist RP1O/A/57001012 Page 1 of I ri,_,AfT`ECTED:
U' U12 IPEP-M-99-38001 POWER LEVEL NCS TEMP NCS PRESS DATE:
U-l T
IME:
U-2 Z
NOUE DECLARED AT:
TSC ACTIVATED AT:
O ALERTDECLAREDAT:
EOF ACTIVATlD AT:_
SAE DECLARED AT:
G.E. DECLARED AT:
REASON FOR EhlER CLASS:
YES NO TIAE LOCATION OR COMMAlENT1S SITE ASSEMBLY O
SITE EVAC. (NON-ESSEN.)
0 SITE EVAC. (ESSENTIAL)
L)
OOTHER OFFSITE AGENCY INVOLVEMENT H
lMEDICAL FIRE
] POLICE NUMBER NUMBER ASSEh1.
DEPLOYED FIELD MON. TEAI1IS ZONES ZONES EVACUATED SHELTERED PARS:
RELEASEINPROGRESS YES (
)
NO (
)
RELEASE PATIIWAY CONTAINMENT PRESSURE PSIG WIND DIRECTION WIND SPEED NUMBER T7IME D
LAST hlESSAGE SENT:
NEXT MESSAGE DUE:
NOTE: EOF COMMUNICATION CHECKS SHOULD BE COMPLE1ED PRIOR TO ACTIVATING TlE EOF.
S HER NOTES RELATED TO TIlE ACCIDENTIEVENTIPLANT EQUIPMENT FAILED OR OUT OF SERVICE
- ,~~~~~~~~~~~~~~~~~~~~~~~~~~o 22
.18 RP/01AI5700I01 2 Page I of 2 Emergency Classification Termination Criteria Yes Page 2 I
No Is the need for a long term cleanup or recovery organization anticipated?
Yes
'X( j)Page 2 Rey. 22
.18 RP10/A/5700/012 Emergency Classification Termination Page 2 of 2 Criteria H
s Yes Terminate the current requirements a
Table Ydassification and dedare the been satisfied?
plant in recovery No Continue with the current dassification until a recovery can be dedared Table I Recovery Conditions No new evacuation or sheltering protective actions are anticipated
_____Containment pressure is less than design pressure
-Decay heat rejection to the ultimate heat sink has been established and either:
Injection and heat removal have redundancy available (2 trains of injectionlDlIR or a train of DIIR and SIG cooling)
OR No additional fission product release or fission product barrier challenges would be expected for at least 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> following interruption of injection. (PIP 0-M96-1645)
_____The risks from recriticality are acceptably low
_____Radiation Protection is monitoring access to radiologically hazardous areas
___Offsite conditions do not limit plant access
_____The News Manager. NRC officials, and State representatives have been consulted to determine the effects of termination on their activities The recovery organization is ready to assume control of recovery operations Go to RP10JA157001024, (Recovery and Reentry)
Rev. 22
.19 Fitness for Duty Questionnaire RPIOIA/5700I01 2 Page I of I Print Name:
Sign Name:
Employee ID M:
ERO Position:
HAVE YOU CONSUMED ALCOHOL IN THIE LAST HIVE (5) HOURS?
MARK TIE A PPROPRIA TE BOX No C
If No, stop here and fold this form and drop it in the box provided.
YES If your answer is Yes, take this form to a member of management for observation.
OBSERVATION DETERMINATION What did you have?
How much did you have?
Can you perform your function unimpaired?
YES [I]
NO FZ-In my opinion, observation of this individual indicates the individual is capable of performing his/her ERO function.
Signature of Management Observer Date Fold the form and drop it in the box provided.
Rev. 22
.20 RPIOIAI5700I012 Page I of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKLIST K'
INITIAL NOTE:
You are only required to complete Enclosure 4.19 (Fitness for Duty Questionnaire) when reporting to the facility outside of your normal work hours.
SIGN in on the TSC staffing board and put on position badge.
SIGN the TSC attendance sheet for a drill.
IF a site assembly is in progress or is conducted SWIPE your ID badge in the badge reader located in the TSC for personnel accountability.
CONTACT your site assembly point, report your location upon activation of the site assembly alarm. {PIP 0-M96-1869)
E STABIASII a log of activities.
DISCUSS with the Site Assembly Coordinator the status of the site assembly in preparation for emergency/drill message updates and possible site evacuation.
Rev. 22
.20 RP/OIA/5700/012 Page 2 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKLIST NOTE:
If the Site Assembly portion of the Emergency I Drill is complete. The Site Assembly Coordinator should assist the Site Evacuation Coordinator with Emergencyl Drill message updates and evacuation coordination.
IF site assembly is still in progress ANNOUNCE the following Initial communication over the P.A. for the appropriate situation by dialing 710, at the beep, dial 80 and begin speaking:
For an Actual Emergency: "Attention all site personnel. This is an emergency message. This is an emergency message. At the present time, we have a (emergency classification). (Report general information of the event/information of importance. Obtain this informationfrom the Offsite agency communicator).
All personnel shall remain at their site assembly location until further instructions are given.
Information will be provided to you as conditions change."
For a Drill:
"Attention all site personnel. This is a drill message. This is a drill message. At the present time, we have a (emergency classification). (Report general information of the eventfinformation of importance. Obtain this information from the Offsite Agency Communicator.):
All personnel shall remain at their site assembly location until further instructions are given."
RECORD time of announcement Rev. 22
.20 RPIO/A/57001012 Page 3 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKIST NOTE:
An additional worksheet for Emergency/Drill Message Updates is on page 8 of 8.
OBTAIN off-site notification information from the Off-site Agency Communicator each lime an off-site notification is made and prepare an Emergency! Drill Message Update as follows:
NOTE:
If it is determined that an announcement should be made to the plant outside of the normal offsite agency communication, get the Emergency/ Assistant Emergency Coordinator's approval prior to the announcement. Use the message format as follows. After the notification is made, provide a copy of the announcement to the Offsite Agency Communicators.
Emergency Message/Drill Message Update: Dial 710; at the beep, dial 80, begin speaking "Attention all site personnel. This is alan emergency/drill message. This is alan emergency drill message. (General Information of the event/information of importance. Obtain this information from the Off-site Agency Communicator.):
RECORD time of announcement Emergency Message/Drill Message Update: Dial 710; at the beep, dial 80, begin speaking "Attention all site personnel. This is a/an emergency/drill message. This is a/an emergency drill message. (General Information of the event/information of importance. Obtain this information from the Off-site Agency Communicator.):
$I RECORD time of announcement Rev. 22
Enclosujre 4.20 R.P/1O/5700I012 Page 4 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKLIST EVALUATE with the Radiation Protection Manager, the Emergency Coordinator and other TSC personnel the need to conduct a site evacuation or relocation of on-site personnel based on the following Event Classification criteria:
Alert-determine by actual plant conditions.
Site Area Emergency-consider evacuationlrelocation of non-essential personnel.
General Emergency-evacuate all non-essential personnel.
NOTE:
- 1. Security sweep priorities are outlined in Security Procedure EXAC-12 and are based on sweeping areas in the direction of the prevailing winds first, such as the discharge canal fishing area.
- 2. The owner controlled area patrol will perform sweeps and evacuate visitors without site contacts, such as fishermen along the discharge canal and persons at the Nature Trail and beach, at the ALERT level.
- 3. For owner controlled areas outside the protected area that must be evacuated, evacuation wardens will perform sweeps of their assigned building areas during regular working hours, Monday thru Thursday. Security will provide sweeps of all other areas, including buildings where evacuation wardens are not assigned during regular and non-regular working hours. Security will provide sweeps of all buildings during non-regular working hours.
- 4. Radiological conditions, wind direction, and the degree of protection provided (outside or inside a building) are examples that might influence sweep priority changes.
PROVIDE guidance to the OSC Coordinator for the priority of evacuation sweeps by Site Services and Security and if priorities are different than normal priorities.
NOTE:
The following informnation may be provided to the EOF via the Offsite Agency Communicators. {PIP-0-M-99-091 1)
NOTIFY EOF anytime personnel are relocated onsite or evacuated from the premises. {PIP-M-01-4276)
Rev. 22
.20 RP01A/5700/012 Page 5 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKLIST NOTE: 1. Evacuations planned inside the Protected Area should be made by contacting Security in the OSC with instructions. Evacuations outside the protected area should be made by contacting Security in the OSC and instructing them to coordinate activities with Site Services representatives in the OSC. When giving evacuation instructions be sure to identify the area for evacuees to relocate to, according to procedure RPIOIA/5700I01 1.
EVALUATE with the Radiation Protection Manager, Emergency Planner and Emergency Coordinator the following:
- Recommendations on the need, path, and transportation options for relocation of on-site personnel.
- Recommendations on need, path, and transportation options for evacuation of non-essential personnel off-site (Training Center lobby I Cowans Ford Dam or offsite I home.)
- Recommendations on need to restrict vehicle (site transportation shuttle, etc.) movement on site.
(PIP O-M97-2871)
Recommendations on need to use a forklift or other appropriate equipment to remove obstacles so that the main entrance across the SNSW dam can be used as a contingency evacuation route.
NOTE:
During a TSC "time out" a Site Assembly or Evacuation Coordinator SIALL report to the designated location at the Emergency Coordinator's Table to provide status/updates. {PIP M98-2065)
PROVIDE periodic updates to Emergency Coordinator as needed and during time outs on site evacuation or on site relocation of personnel.
NOTE:
OSC Site Services and EOF Services personnel will arrange for alternate transportation.
PREPARE for turnover of site personnel (TSC, OSC and other essential personnel).
The following items should be discussed with RP Manager and Emergency Planner several hours in advance of anticipated turnover time.
- Are parking lots and personal vehicles contaminated?
Rev. 22
Enclosbre 4.20 RP/O/A/5700/012 Page 6 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKLIST YJ Will buses or other alternate transportation be needed to transport personnel to and from the site?
Wlill pickup/drop off points outside the EPZ need to be established?
IF the decision is made to evacuate personnel from the site, THEN INFORM Off-site Agency Communicators (or the EOF if activated) to notify appropriate offsite agencies:
Approximate number of people to be evacuated Evacuation destination:
- Home Technical Training Center Cowans Ford Other's PROVIDE to the EOF an estimate of the number of people to be evacuated.
NOTE:
Security may need to notify the Mecklenburg Police (91 1) requesting them to assist in traffic control, if deemed necessary by the Emergency Coordinator or Security Shift Supervisor.
IF the decision is made to evacuate, NOTIFY Security to assist with traffic control as needed.
IF evacuation of non-essential personnel is planned, REQUEST Managers, during a time out, to identify and inform their own essential personnel to remain, as all others will be evacuated.
IF the decision is made to evacuate, NOTIFY the chosen Evacuation-Relocation site of the expected arrival of personnel.
Technical Training Center 9-704-579-3210. This is a cellular telephone carried by an industrial security guard who roams the site seven days a week, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day, Powerhouse at Cowans Ford Dam - 4335. This phone rings throughout the dam site. This location is staffed Monday through Friday, 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> per day. IF no answer at 4335, call the Hydro Central Operations Office at 8-382-6838 or 8-382-6836 and request that the security gates at the plant entrance at highway NC73 and the Cowans Ford Power House be unlocked so that the Cowans Ford service bay can be used as an evacuation site.
Rev. 22
.20 RP101A157001012 Page 7 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKLIST NOTE:
Inform Control Room that you have already contacted Security and the Evacuation site with information about the evacuation of personnel.
IF the decision is made to evacuate, DIRECT the Control Room to evacuate the site per (RP/O/A/5700/O 1I) by calling the Control Room SRO at extension 4138 (then select option 3) and giving the following evacuation route information for non-essential personnel:
Non-essential personnel should:
A. Proceed to (Training Center lobby / Cowans Ford Dam I Home I Other)
RECORD the time the site evacuation begins Ends_
PREPARE for 24-hour coverage for your position as necessary.
POST updates to the site assembly I evacuation board located in the Site Assembly Coordinators office as needed.
PROVIDE completed paperwork to the Emergency Planner upon deactivation of the emergency facility.
Rev. 22
.20 RP/01AI5700/012 Page 8 of 8 SITE EVACUATION COORDINATOR TSC ACTIVATION CHECKUST t>
ADDITIONAL WORKSHEET FOR EMERGENCY/DRILL MESSAGE UPDATES Emergency Message/Drill Message Update: Dial 710; at the beep, dial 80, begin speaking "Attention all site personnel. This is alan emergency/drill message. This is a/an emergency drill message. (General Information of the event/information of importance. Obtain this information from the Off-site Agency Communicator.):
RECORD time of announcement Initial_
Emerp~ency Message/Drill Message Update: Dial 710; at the beep, dial 80, begin speaking "Attention all site personnel. This is a/an emergency/drill message. This is alan emergency drill message. (General Information of the event/information of importance. Obtain this information from the Off-site Agency Communicator.):
RECORD time of announcement Initial_
Emergency Message/Drill Message Update: Dial 710; at the beep, dial 80, begin speaking "Attention all site personnel. This is a/an emergency/drill message. This is alan emergency drill message. (General Information of the event/information of importance. Obtain this information from the Off-site Agency Communicator.):
RECORD time of announcement _______.
Initial______
Rev. 22
i nclosure 4.21 RP/O/A/5700/012 Page I of I ESTABLISHING COMMUNICATIONS LINKS BEWVEEN SAMG EVALUATORS NOTE:
OPS Procedure Support in the TSC will serve as the lead SAMG evaluator and will be assisted by Reactor Engineer and Systems Engincer in the TSC, as well as Accident Assessment Interface in the EOF. OPS Procedure Support is expected to direct the other evaluators in what they should be looking at strategically, plus ensure that SAEG-1 is completed appropriately as directed by the guidelines.
ESTABLISH communications links between the SAMG evaluators (TSC OPS Procedure Support, TSC Reactor Engineer, TSC System Engineering Manager, and EOF Accident Assessment Interface) by dialing on to the RP controller bridge at 875-4833. This is a 6-party bridge line.
EVALUATE using an alternate bridge line listed below if for some reason the RP Controller bridge is unavailable or if other communications links are desired or needed. Dial the number listed as desired to determine if that bridge is currently being used. If the desired bridge line is not being used, then the appropriate parties may dial in to use it.
EP Controller bridge (12 - party) 875-4575 McGuire site bridge (6 - party) 875-3030 McGuire site bridge (6 - party) 875-3200 Rev. 22