DISPOSITION OF THE ORIGINAL DOCUMENT WILL BE TO THE TRANSMITTAL SIGNATURE UNLESS RECIPIENT IS OTHERWISE IDENTIFIED BELOW
- 1) 00059 MARTIN J. VIRGILLO, DIRECTOR
- 2) 00692 MCG OPS STAFF MGR MG01OP
- 3) 01057 DOC MGMT MISC MAN EC03C
- 4) 01155 DIVISION OF RAD. PROTECTION
- 5) 02224ETBEADLE CNO1EP
- 6) 03044 MCG DOC CNTRL MISC MAN MGO5DM
- 7) 03283 MNS RP-MG01RP
- 8) 03744 OPS TRNG MGR. MG03OT
- 9) 04102 E M KUHR ECO50
- 10) 04375 R L HASTY MG03TD
- 11) 04809 MCG PLANT ENG. LIBR. MG05SE
- 12) 05606 J C MORTON MG01EP
- 13) 05848 NUCLEAR FACILITY PLANNER
- 14) 05849 NUCLEAR FACILITY PLANNER, NC
- 15) 08047 EMERG. PLAN MANAG. ON03EP DOCUMENT NO EMERGENCY PLAN IMPLEMENTING PROC.
EPIP COVERSHEET EPIP INDEX PAGES 1-3 HPIO/B/1009/023 r
IOTAL QA CONEI NA NA NA NA REV #/ DATE 032 032 032 005 08/15/02 08/15/02 08/15/02 08/15/02
- _____________ J ____________________ I Duke Power Company DOCUMENT TRANSMITTAL FORM REFERENCE MCGUIRE NUCLEAR STATION EMERGENCY PLAN IMPLEMENTING PROCEDURES Page I of I DISTR CODE MADM-195 vi 2
Vi 3
V1 4
5 vi Vi Vi vi v-I Vi Vi Vi VI It, V1*
PRIORITY Normal 6
7 8
9 10 11 12 13 14 15 REMARKS:
PLEASE UPDATE YOUR MANUAL ACCORDINGLY 0
H B BARRON, JR VICE PRESIDENT MCGUIRE NUCLEAR STATION BY:
J C MORTON MGO1EP JCM/CMK Date:
09/17/02 Document Transmittal #:
DUK022600002 QA CONDITION
[: Yes U No OTHER ACKNOWLEDGEMENT REQUIRED
Duke Power Company P.O. Box 12700 Document Management MGO1S2 Hagers Ferry Road Huntersville, N.Cf 28078 Rec'd By Date I
TOTAL V1 V1 V1I V 1 VlI vz VlI V I V I 10 V1
DUKE McGUIRE NUCLEAR SITE EMERGENCY PLAN IMPEEMENTING PROCEDURES APPROVED: S w:-
SAFEY A, URANCE MANAGER DATE APPROVED EPIP Index Page 1 EPIP Index Page 2 EPIP Index Page 3 Dated 8/15/2002 Dated 8/15/2002 Dated 8/15/2002 HP/0/B/1009/023, rev. 005 K11-51-eq,002--
Dated 8/15/2002,
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
RPIO/A157001000 RP/O/A15700/001 RP/O/A/57001002 RPIO/A15700/003 RP/0/A15700/004 RP/O/A/5700/05 RPIO/A/57001006 "RP/O/A15700/07 RPIOIAI57001008 RPIOIAJ5700/009 RPIO/A15700/010 RPIOIAI5700/011 RPIOIAI5700/012 RPIOIAI5700/013 RPIOIAI5700114 RPIO/A157001015 RPIO/A/5700/16 RPIO/A15700117 RPI0/A/57001018 RP/01A15700/019 RP/OA15700/020 RPI01AI5700/21 RP/O/A/5700/022 RPIO/A157001024 RPIOIA/5700/026 RPIOIBI5700/023
ý_
OPIOIB/6200/090 TITLE REVISION NUMBER Classification of Emergency Notification of Unusual Event Alert Site Area Emergency General Emergency Care and Transportation of Contaminated Injured Individual(s) From Site to Offsite Medical Facility Natural Disasters Earthquake Release of Toxic or Flammable Gases Collisions/Explosions NRC Immediate Notification Requirements Conducting a Site Assembly, Site Evacuation or Containment Evacuation Activation of the Technical Support Center (TSC)
Activation of the Emergency Operations Facility (EOF)
Emergency Telephone Directory Notifications to the State and Counties from the EOF EOF Commodities and Facilities Procedure Emergency Data Transmittal System Access Notifications to the State and Counties from the TSC Core Damage Assessment Activation of the Operations Support Center (OSC)
EOF Access Control Spill Response Procedure Recovery and Reentry Procedure Operations/Engineering Technical Evaluations in the Technical Support Center (TSC)
Community Relations Emergency Response Plan PALSS Operation for Accident Sampling Rev. 008 Rev. 016 Rev. 016 Rev. 016 Rev. 016 DELETE Rev. 009 Rev. 007 Rev. 004 Rev. 002 Rev. 013 Rev. 005 Rev. 020 DELETE DELETE DELETE DELETE DELETE Rev. 011 Rev. 004 Rev. 012 DELETE Rev. 009 Rev. 002 Rev. 002 Rev. 002 DELETED August 15, 2002 Rev. 32 I
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
HP/O/B/10091002 HP/0/B/1009/003 HP/0/B/1009/05 HPIOJB/ I009/006 HP/OIB/1009/010 HPll/B/1009/015 HPI2IBII 009/015 HP/OIB/1009/016 HP/O/B/ 1009/020 HP/OJB/l0091021 HP/OIB/1009/022 HP/OIB/I 0091023 HP/0OB/1009/024 HPIOIB/1009/029 SH101B/2005/001 SH/0/B/2005/002 SR/0/B/2000/01 SR/O/B/2000/002 SR/O/B/2000/003 SR/O/B/2000/004 TITLE Alternative Method for Determining Dose Rate Within the Reactor Building Recovery Plan Initial Evaluation of Protective Action Guides Due to Abnormal Plant Conditions Procedure for Quantifying High Level Radioactivity Releases During Accident Conditions Releases of Radioactive Effluents Exceeding Selected
"-Licensee Commitments Unit I Nuclear Post-Accident Containment Air Sampling System Operating Procedure Unit 2 Nuclear Post-Accident Containment Air Sampling System Operating Procedure Distribution of Potassium Iodide Tablets in the Event of a Radioiodine Release Manual Procedure for Offsite Dose Projections Estimating Food Chain Doses Under Post-Accident Conditions Accident and Emergency Response Environmental Monitoring for Emergency Conditions Personnel Monitoring for Emergency Conditions Initial Response On-Shift Dose Assessr.ment Emergency Response Offsite Dose Projections Protocol for the Field Monitoring Coordinator During Emergency Conditions Standard Procedure for Public Affairs Response to the Emergency Operations Facility Standard Procedure for EOF Commodities and Facilities Activation of the Emergency Operations Facility Notification to States and Counties from the Emergency Operations Facility August 15, 2002 Rev. 32 REVISION NUMBER Rev. 002 Rev. 004 DELETED Rev. 006 Rev. 006 DELETED DELETED Rev. 003 DELETED Rev. 001 Rev. 003 Rev. 005 Rev. 002 Rev. 006 Rev. 001 Rev. 002 Rev. 003 Rev. 002 Rev. 009 Rev. 005 2
EMERGENCY PLAN IMPLEMENTING PROCEDURES INDEX PROCEDURE #
McGuire Site Directive 280 EP Group Manual MNS RP Manual:
PT/O/AI46001088 TITLE Site Assembly/Accountability and Evacuation/Containment Evacuation Section 1.1 Emergency Organization Section 18.1 Accident and Emergency Response Section 18.2 Environmental Monitoring for Emergency Conditions Section 18.3 Personnel Monitoring for Emergency Conditions Section 18A Planned Emergency Exposure FunctionahCheck of Emergency Vehicle and Equipment August 15, 2002 Rev. 32 REVISION NUMBER DELETED Rev. 017 DELETED DELETED DELETED DELETED Rev. 007 3
(R04-01)
,,Duke Power Company PROCEDURE PROCESS RECORD (1) ID No. HP/O/B/IO09/023 Revision No.
005
'REPARATION (2) Station (3) Procedure Title McGuire Nuclear Station Environmental Monitoring For Emergency Conditions (4) Prepared By Jeff Litaker Date June 24,2002 (5) Requires NSD 228 Applicability Determination?
[
Yes (New procedure or revision with major changes)
El No (Revision with minor changes)
El No (To incorporate previously approved changes)
(6) Reviewed By (QR)
Date
"/1/0 Cross-Disciplinany Review By (QR) NAg*-.
Date
,h'/d Reactivity Mgmt. Review By (QR) NA Date 7__o_____
Mgmt. Involvement Review By.
(OPS Supt.)- NA.-- F-Y" Date
'/7/10 z (7) Additional Reviews Reviewed By 1
Date iZ,*7Z Reviewed By Date (8) Temporary Approval (if necessary)
By (OSM) Date By
/.
(QR) Date (9) Approved By Date (g/S"O2_
PERFORMANCE (Compare with Control Copy every 14 calendar days while work is being performed.)
(10) Compared with Control Copy Date Compared with Control Copy_
Date Compared with Control Copy Date (11) Date(s) Performed Work Order Number (WO#)
COMPLETION (12) Procedure Completion Verification 11 Yes LI NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?
El Yes Dl NA Required enclosures attached?
El Yes El NA Data sheets attached, completed, dated and signed?
0l Yes El NA Charts, graphs, etc. attached, dated, identified, and marked?
[] Yes [E NA Procedure requirements met?
Verified By Date (13) Procedure Completion Approved Date
ý,.
) Remarks (Attach additional pages, if necessary.)
Form based on NSD 703 App D (Procedure Process Record)
Duke Power Company McGuire Nuclear Station Environmental Monitoring for Emergency Conditions Information Use Procedure No.
HP/O/B/1009/023 Revision No.
005 Electronic Reference No.
MC0095LY
HPIOnIBl 009/023 Page 2 of 9 Revision History (significant issues, limited to one page)
Rev 005 (06/24/02) Deleted Step 4.1.2 for FMT members to be issued pocket dosimeters.
HP/O/B/1009/023 Page 3 of 9 Environmental Monitoring for Emergency Conditions INFORMATION USE
- 1. Purpose To provide a systematic method for identifying airborne plumes or liquid effluents, and obtaining field data indicative of the radiation exposure to the generil public, following a release of radioactive material.
- 2. References 2.1 HP/Oe1/1i009/027 (Operation of ESP-2) 2.2 PT/O/A146001088 (Functional Check of Emergency Vehicle and Equipment) 2.3 SH/0/B/2005/002 (Protocol for the Field Monitoring Coordinator During Emergency Conditions)
- 3. Limits and Precautions 3.1 During drills/exercises, Field Monitoring Team(s) (FMTs) shall NOT be required to don respirators. This is to assure safe vehicle operation during drill/exercise. During emergency situations respirator use may be required.
3.2 FMT personnel shall be aware of dose and dose rate alarm setpoints on DMC-2000s used in the field. Dose and dose rate alarms are referenced on RWP 98.
3.3 After the use of any Emergency Kit, a full inventory of that kit is required per PT/O/A/4600/88 (Reference 2.2). The checklist in the kit shall be signed and dated each time the kit is inventoried.
- 4. Procedure 4.1 Field Monitoring Team (FMT) Activation and Dispatch 4.1.1 Upon activation of the Emergency Response Organization, report to the OSC.
"* Form two teams to perform initial surveys for plume boundary. IF necessary dispatch additional beta/gamma monitoring teams.
"* Drivers for Field Monitoring Vehicles are provided by C&F. Ensure that each team has a driver prior to leaving the OSC.
Iw/OIBIl 009/023 Page 4 of 9 Personnel NOT trained for emergency response may assist a trained Radiation Protection Technician to do surveys and/or drive emergency vehicles.
"* Communicate team assignment to the OSC RP Supervisor, or qualified designee.
4.1.2 The OSC RP Supervisor, or qualified designee, shall brief at least one member of each FMT on current plant conditions (plant status, release in progress, emergency classification).
4.1.3 Following the plant status brief from the OSC RP Supervisor, obtain current meteorological data using the guidance in Enclosure 5.11.
4.1.4 WHEN directed, make preparations for dispatch by completing pre-dispatch portion of Enclosure 5.1 (Sample Van) or Enclosure 5.2 (Survey Vehicle).
- The Radiation Protection Manager can elect to dispatch FMT's at his/her discretion.
4.1.5 Follow FMC direction concerning protective dress requirements according to existing conditions per RWP-98.
4.2 Field Monitoring Team (FMT) Communications 4.2.1 Maintain open radio communications with the FMC. IF the radio becomes inoperable, telephone:
TSC Dose Assessment 875-4976 FMC at EOF (704) 382-0735/0736 RP Sample Van 1 (cellular phone) 534-1563 RP Sample Van 2 (cellular phone) 534-1564 4.2.2 Provide pertinent, general information. Do NOT provide detailed, specific plant information.
4.2.3 During a drill, repeat the statement, "This is a drill", or, "This is an exercise message", with each radio transmission using the proper radio call signs (Base - WQC700, Mobile -KA82138).
4.2.3.1 The Base Station must give the radio call sign with each transmission.
HP/0/B/l 009/023 Page 5 of 9 4.2.3.2 The field teams do NOT have to use the radio call sign when addressing the Base Station. The field teams must give the radio call sign when addressing other field teams.
4.2.3.3 For any backup sampling vans from other stations, the call sign shall be preceded by the station name (example "Oconee sample van 1").
4.2.3.4 Vehicles drawn from the McGuire garage that are designated as beta/gamma survey teams shall use 'alpha, bravo, charlie, and delta' designations during radio messages.
4.2.3.5 WHEN transmitting vital information, use repeat back method of communications and the phonetic alphabet.
4.2.3.6 Follow FCC guidelines for radio communications at all times.
4.3 Locating and Tracking the Plume 4.3.1 Begin plume boundary identification by monitoring dose rates while traversing east and west of the site (= 0.5 miles), traveling on owner controlled roads only.
4.3.1.1 East of site - travel from the Hwy. 73 (stoplight) entrance to the MOC to the end of the discharge canal fishing area.
4.3.1.2 West of site - travel from the medical facility parking lot to approximately the lower level intake using the road by the Initial Holdup Pond.
4.3.1.3 Communicate location to the TSC and/or EOF when plume edge is identified. Any change in background dose rate shall be assumed to indicate plume edge. Communicate changes in dose or count rates immediately.
4.3.1.4 Do NOT enter the plume unless directed by the FMC.
4.3.2 Be prepared to take full direction from the Field Monitoring Coordinator (FMC) at the EOF, when that position is prepared to do so.
4.3.2.1 Major roadways delineate major territories surrounding the plant.
Either all or a portion of these sections would be expected to be affected to some degree by radioactivity released from the plant.
Utilize major roadways to access suspected regions (outer edges, leading edge(s), centerline) of the plume, as necessary.
HP/O/B/1009/023 Page 6 of 9 A. Major roadways on the EPZ map are identified by numerical designations and responsibility level (federal, state, county or city) designations.
B. Selected roadways on the EPZ map are identified by a specific name, rather than a numerical responsibility designation.
4.3.2.2 Each predetermined sampling location is denoted by a red text oval on the map. The sampling point designator indicates the protective action zone the point is in and the mileage from the plant.
A. The FMC should use the points as landmarks when directing the teams.
B. The point locations can be read directly from the map or from the directions in Enclosure 5.6.
4.3.2.3 While enroute an= at sampling locations, report the maximum radiation level, ar.d location of plume boundaries to the FMC.
4.3.2.4 Record radiation dose rates and sample results on Enclosure 5.7.
4.3.2.5 Once a release has occurred, close vehicle windows and place ventilation off or on recirculation to minimize contamination until the plume area is identified.
4.3.2.6 Ensure that count rate meter is on and is monitored during transport to sampling locations.
4.3.2.7 IF any equipment becomes inoperable, notify the FMC Aind await further instructions.
4.3.2.8 Record plant status update information on Enclosure 5.8.
4.3.2.9 Verify worker classification changes on RWP with changes in plant conditions.
4.3.2.10 Record any or no exposure received and turn in dosecards upon returning to site. Submit dosecards as record for all drills and exercises.
HP/OIBll 009/023 Page 7 of 9 CAUTION:
Park vehicles completely off the road when sampling and use emergency flashers and the strobe while stopped.
Wear reflective vests when leaving a vehicle parked on the roadside for sampling.
Vests are stored in the rear section cabinet with protective clothing.
4.4 WHEN directed, collect additional environmental samples, including but NOT limited to: air samples, smears of surrounding areas, integrated dose over a period of time with TLDs, vegetation, sediment, water, and milk, as requested by the FMC. Label and save each for analysis. FMTs may also be requested to retrieve and replace environmental air samplers and/or TLDs.
4.4.1 To collect a vegetation sample, use the shears to cut enough broad leaf vegetation to fill a 12"x12" poly bag.
4.4.2 To collect a soil sample, estimate one square foot of soil and dig out one inch deep.
4.4.3 To collect a water sample, fill a one gallon cubitainer. For differences in elevation, or samples that are difficult to obtain, use the limnological sampling equipment (see Enclosure 5.3).
4.4.4 To perform a contamination survey, take smears on stationary, horizontal surfaces, e.g. mailboxes, gas pumps, etc., Do NOT perform contamination surveys on automobiles!
4.4.5 To collect an air sample:
NOTE:
Be aware of terrain during air sampling or surveying (i.e., windbreaks formed by landscape or vegetation) which could inhibit acquiring representative samples.
4.4.5.1 Position sample van air sampling port in the direction of the plant.
4.4.5.2 Load Particulate and Charcoal (P&C) cartridge into P&C holder.
4.4.5.3 Remove the cover from the air sampling port.
4.4.5.4 Insert P&C holder into the sample port to ensure outside air is sampled.
4.4.5.5 Start air sampler and run for required time. (Normal air sample is 5 minutes at 2 CFM).
HPmOIBl 009/023 Page 8 of 9 4.4.5.6 Stop the air sampler.
4.4.5.7 Remove P&C holder from the air sampling port.
4.4.5.8 Replace cover on air sample port.
4.4.5.9 Move van to a low background area.
4.4.5.10 WHEN van is no longer in the plume, purge the P&C by permitting 15 ft3 of air to flow through the sample cartridge. (7.5 minutes @ 2 cfm) 4.4.5.11 Remove the P&C from the P&C holder.
4.4.5.12 Separate the P&C.
4.4.5.13 Label particulate and charcoal and retain the particulate filter for gamma spec analysis.
4.4.5.14 Count the air sample charcoal cartridge, document and report results using Reference 2.1.
4.4.5.15 Retain the charcoal cartridge for further analysis.
4.5 FMT Turnover 4.5.1 FMTs shall be relieved as directed by the FMC.
4.5.2 Provide turnover to the relief FMTs, using Enclosure 5.10.
4.5.3 Turn in all data sheets to the FMC as directed.
4.5.4 After being relieved, report to a counting facility designated by the FMC for a post-job BBA.
- 5. Enclosures 5.1 Sample Van FMC Checklist 5.2 Survey Vehicle FMT Checklist 5.3 List of Designated Limnological Sample Points 5.4 Detailed Guide to All TLD Sample Locations 5.5 List of Designated Milk Sample Locations
HPIO/B11009/023 Page 9 of 9 5.6 Directions for Predetermined Survey/Sampling Locations 5.7 Field Monitoring Survey Data Sheet 5.8 Periodic Status Update for Field Monitoring Teams 5.9 Vehicle Refueling 5.10 FMT Turnover Checklist 5.11 Obtaining Meteorological Data from SDS
.1 HPIOB/1009/023 SAMPLE VAN FMT CHECKLIST Page 1 of 2 PRE-DISPATCH Li Ensure that current plant status and meteorological information has been obtained.
o Obtain Emergency key set (#905 and 906) from Security at the PAP. Proceed to the equipment storage area (Room 158 of the Administration Building) and unlock the equipment storage locker.
o Obtain the following equipment: Normal issue TLD, electronic dosimeter (DMC-2000) and a dose card. Sign in on RWP-98. Ensure the DMC-2000 is on and has been re-zeroed. ED alarm setpoints are 50 mR/hr (dose rate) and 15 millirem (accumulated dose). ED's are reset by placing in the manual reader provided.
o Obtain portable instruments (ion chamber and count rate meters) and source check. Survey the area for radiation levels.
o Remove portable'radios from chargers (one unit for each FMT). Screw in the antenna to the top of the radio. Turn the off/on/volume control switch on the top of the radio until SELF TEST is displayed on the front. IF MCGUIRE C17 does NOT display after SELF TEST, turn the numbered switch on the top of the radio to position 3 and lock with the locking ring. Ensure that the small toggle switch is set to position "A".
El Test the radios using the mobile call sign: "WQC 700, McGuire Base, this is KA8-2138, portable radio check. Do you copy?" IF McGuire Base does NOT respond, perform radio checks with the other sample van using the mobile call sign "KA8-2138, Sample Van -
(other sample van), this is Sample Van __
(your sample van) portable radio check. Do you copy?"
IF a radio does NOT function, remove it from service by removing the battery. Ensure that the radio is turned off before removing or replacing any battery.
0i Obtain all other necessary equipment: respirators, ESP-2's and check sources. Obtain canvas bags ESK-1 or ESK-2 (sample van kits). They can be used to carry instruments and respirators. All protective clothing is located in the back cabinet of the sample vans.
Li One team shall call the TSC Dose Assessor at 875-4976 to determine the status of any release and communicate this information to the other teams.
Li Proceed to the sample vans monitoring portable instruments in transit. Start sample van engines and stabilize inside temperature.
0i Turn on the sample van radio. The unit will display SELF CHECK and MCGUIRE in sequence.
IF MCGUIRE is NOT displayed after SELF CHECK, press the MODE key until MCGUIRE is displayed.
0i Test the radios using the mobile call sign: "WQC 700, McGuire Base, this is KA8-2138, sample van 1 (or 2). Do you copy?" "IF McGuire Base does NOT respond, perform radio check with the other sample van using the mobile call sign: "KA8-2138 Sample Van (other sample van), this is Sample Van (your van). Do you copy?"
.1 HP/0/IB/1009/023 SAMPLE VAN FMT CHECKLIST Page 2 of 2 o Turn on the cellular phone. Unlock the phone for use by pressing the last three (3) numbers of the cell phone number. Test the phone by calling TSC dose assessment at 875-4976. It may be necessary to move the vans from under the unit high voltage lines to test the cellular phones.
o Start the power inverter (located behind the left side of the driver's seat) to the ON position. The air sampler and plug mold strip are now energized. The air sampler is located on the left side arm rest, back seat.
T o Set up ESP-2's. Perform background and source checks in accordance with HP/OIB1009/027.
Sample vans should perform background and source checks while the van is stationary. Report any problems to the TSC/EOF.
0J Notify TSC Dose Assessors that pre-dispatch checks are complete and: (circle one)
- a. Sample Van (1,2) is proceeding west of the plant to traverse from Medical Facility parking lot to aplfixiiiiately the lower level intake using the road by the initial holdup pond.
- b. Sample Van (1,2) is proceeding east of the plant to traverse from Hwy 73 (stop light) entrance to the MOC to the end of the discharge canal fishing area.
- c. Sample Van (1,2) is standing by at (location).
UPON RETURNING TO THE SITE:
o Ensure mobile van radios are switched off.
o Ensure that power inverter is turned to the OFF position.
o Perform inventory of protective clothing and emergency equipment per PTiO/A/4600/088.
(Notify the RP Staff Scientist of any discrepancies.)
o Turn off all instruments and portable radios and place in storage cabinet.
O Remove portable radio antennas and place radio into a charging unit.
o Ensure that EDs display the calibration date and place in storage cabinet.
0 Ensure that storage cabinet is closed and locked.
Li Turn in all relevant surveys and checklists.
0 Turn in dosecards to DRC.
0 Return keys to Security at the PAP.
.2 HP/O/B/1009/023 SURVEY VEHICLE FMT CHECKLIST Page 1 of 2 PRE-DISPATCH ol Ensure that current plant status and meteorological information has been obtained.
o Obtain Emergency key set (#905 and 906) from Security at the South PAP. Proceed to the equipment storage area (Room 158 of the Administration Building) and unlock the equipment storage locker.
o Obtain the following equipment: a normal issue TLD, electronic dosimeter (DMC-2000) and a dose card. Sign in on RWP-98. Ensure the DMC-2000 is on and has been re-zeroed. ED alarm setpoints are 50 mRlhr (dose rate) and 15 millirem (accumulated dose). ED's are reset by placing in the manual reader provided.
0 Obtain portable instruments (ion chamber and count rate meters) and source check. Survey the area for radiation levels.
0 Remove portable radios from chargers (one unit for each FMT). Screw in the antenna to the top of the radio. Turn the off/oa/volume control switch on the top of the radio until SELF TEST is displayed on the front. IF MCGUIRE C17 does NOT display after SELF TEST, turn the numbered switch on the top of the radio to position 3 and lock with the locking ring. Ensure that the small toggle switch is set to position "A".
El Test the radios using the mobile call sign: "WQC 700, McGuire Base, this is KA8-2138, portable radio check. Do you copy?" IF McGuire Base does NOT respond, perform radio check with one of the sample vans using the mobile call sign:
"KA8-2138, Sample Van _
(1 or 2), this is a portable radio check. "Do you c6py?"
IF a radio does NOT function, remove it from service by removing the battery. Ensure that the radio is turned off before removing or replacing any battery.
o Obtain the designated emergency kits ESK-3 or ESK-4 (canvas bags) from the locker. *All other necessary equipment is located in the kits.
o Proceed to the McGuire Garage by personal vehicle or Sample Van. IF obtaining pool vehicles after hours, weekends or holidays, call Security from the Garage gate phone to gain access. The phone number is located on the phone housing.
.2 HP/0i/B/1009/023 SURVEY VEHICLE FMT CHECKLIST Page 2 of 2 0
Notify the TSC Dose Assessor that pre-dispatch checks are complete and; (circle one)
- a. Survey Vehicle (alpha, bravo, charlie, delta) is proceeding west of the plant to traverse from Medical Facility parking lot to approximately the lower level intake using the road by the initial holdup pond.
- b. Survey Vehicle (alpha, bravo, charlie, delta) is proceeding east of the plant to traverse fro-n Hwy 73 (stop light) entrance to the MOC to the end of the discharge canal fishing area.
- c. Survey Vehicle (alpha, bravo, charlie, delta) is standing by at (location)
UPON RETURNING TO THE SITE:
0 Perform inventory of emergency equipment per PTIIO/A4600188 (Reference 2.2).
Notify the RP Staff Scientist of any discrepancies.
0 Turn off all instruments and portable radios and place in storage cabinet.
0 Remove portable radio antennas and place radio into charging unit.
0 Ensure that ED's display the calibration data and place in storage cabinet.
0 Ensure that storage cabinet is closed and locked.
0I Turn in all relevant surveys and checklists.
0 Turn in dosecards to DRC.
0 Return emergency key set to Security.
.3 HP/0/IB/10091023
<List of Designated Limnological Sample Points Page 1 of 1 Mt Holly Intakes - Sector E (South - 5 miles)
Sample elevation - 630' Accessible on Hwy 273, north of Duke Power Mt. Holly Training Center.
Charlotte Intakes - Sector E (South) 5-6 miles Sample elevation 635'- Unit 1 intake 640 - Unit 2 intake 637'- Unit 3 intake Accessible by land on SR 2004 (Mt. Holly-Huntersville Road)(Pump Station Road)
LIMINOLOGICAL SAMPLING DIRECTIONS (1) Pull one of the blue stoppers out of the end of the main tube and attach the wire loop to one of the small pins on the handle tripping mechanism.
(2) Repeat for the other stopper.
(3) Lower the bottle under water keeping the line taut, and drop the weight to strike the tripping mechanism. This will release the cables and close the bottle.
(4) For shoreline sampling when the elevation difference is small, attach one stopper and fill the bottle with water by scooping. The bottle can now be closed and the black nozzle used to empty the sample into a cubitainer.
NOTE:
- 1. Full lake elevation is 760'.
- 2. Catawba River spillway elevation (for Charlotte intakes) is 647'6"
.4 HPIO/B/1009/023 Detailed Guide to All TLD Sample Locations Page 1 of 7 This enclosure is meant to provide a guide to one who is NOT familiar with the environmental TLD sample route. Appropriate deviations from this sequence and route may be made as necessary.
A. Sample location numbers:
143 -
Point of land north of intake pumps.
144 -
On the fence, at air sampling site #120, near E.P. Boat House.
145 -
On the fence, at air sampling site #121, near guard house at Training and Technology Center.
146 -
Shoreline of discharge canal, below the bridge.
147 -
On the fence, at the Training and Technology Center, Environmental Laboratory, behind the QA building, next to the beige aluminum building.
148 -
Second utility pole on-the right-hand side of Energy Explorium Entrance from Hwy. 73.
149 -
Near site fence, 200 feet east of U-2 Access Road on Hwy. 73.
151 -
Fence east side inside O.C. (Owner Controlled) Gate #2.
152 -
Near railroad tracks west of McGuire main entrance.
153 -
Clearing on the left, inside O.C. (Owner Controlled) Gate #4 (S. River Gate).
154 - Edge of river bank, access O.C. (Owner Controlled) Gate #5 (Lower Dam Access).
156-Top of earthen dam, access O.C. (Owner Controlled) Gate #7.
157 -
Williamson access area (on the Mecklenburg Neck) on utility pole just beyond access sign.
158 - End of state maintained Road #2189 (Bethel Church Road).
159 -
Anchorage Marine Shipyard at Holiday Harbor Marina.
160 -
On the fence, at Anchorage Marine Showroom.
161 - Main power pole at the intersection of Hwy. 21 and Hwy. 73.
162 - First power pole at the intersection of Gilead Road and State Road #2139.
163 -
At the intersection of Hambright Road and McCoy Road (State Road #2138).
164 -
Power pole at the intersection of Beatties Ford Road and Hambright Road.
165 -
Approximately 2 miles down power plant road from River Bend Steam Station.
166 167 168 169 170 171 172 173 174 175 177 178 180 181 182 186 187 191 196 197 198 199-.4 HPiOIBl1009/023 Detailed Guide to All TLD Sample Locations Page 2 of 7 Water tank across from River Bend Steam Station.
Behind Lucia Volunteer Fire Department.
Power pole at State Road #1511 at Killian Creek.
Last power pole on Kincaid Road.
Second utility pole on right from intersection of Hwy. #73 and State Road #1386.
Utility pole at Triangle Hardware.
Power pole at the residence located at 625 Golf course Ln.
First utility pole on S.R. #1891 intersection with S.R. #2393.
On the fence, at air sampling site #134, near East Lincoln Junior High School.
Utility pole, fifth house on right, Hoyle Road.
On a tree at the residence, 908 Belmarrow Dr.
Duke Power Substation at AmeriSteel Corporation.
Mooresville Water Treatment Plant.
Davidson Water Treatment Plant.
On the fence, at air sampling site #133, at Cornelius substation.
On peninsula beyond MNS fishing access.
First gravel road past Energy Explorium.
Fenced pumping station on John Connor Dr.
New Landfarm fence.
New Landfill fence.
Old Landfill fence.
Old Landfill fence at groundwater well MW-i.
.4 HP/O/B/10091023 Detailed Guide to All TLD Sample Locations Page 3 of 7 B. Directions to sampling locations:
NOTE:
Contact Security at Ext. 4460 to open all O.C. (Owner Controlled) Gates.
Site #144 Located inside the air sampling cage by the HP Boathouse (air site #120)
Site #187 Continue past Energy Explorium and take first right on to a gi',avel road. The TLD is located inside air sampler cage (air site #195).
Site #186 Proceed toward the Plant to the end of the fishing access. Bear to the right at the site boundary fence, unlock the cable and proceed out on the peninsula. The TLD is on a stake about half way out the peninsula to the right on a stake.
Site #143 Continue out the peninsula to the point where the TLD is located on a stake near the osprey nest site.
Site #145 Heading back toward the guardhouse, the TLD is located inside the cage at the air sampling site #121.
Site #146 Passing the guardhouse on your left, the TLD is located on the left, attached to the backside of the light pole, just after crossing the bridge.
Site #147 Continue forward to main entrance road. Turn into the QA entrance on your left. The TLD is on the chainlink fence beside the brown aluminum building. (A large oak tree is in front of the fence).
Site #148 Continue down entrance road to the fourth light pole on the left. The TLD is on the backside of the utility pole. You'll have to pull over to the right off of the road and allow the other person to pick up the TLD on the left side of the road.
Site #149 Continue on to the stop sign at Hwy 73. Turn right and go to the first clearing on the right. The TLD is located on the site boundary fence.
Site #189 Continue forward on Hwy 73 toward MNS. The TLD is located just off the right side of the road on a stake near a tree with a red painted dot just before transmission lines cross Highway 73.
Site #152 Continue past MNS main entrance for approximately 100 yards to the clearing on your right. The TLD is located between on a stake..
Site #151 Enter MNS main entrance. The TLD is located on the fence by OC gate #2 immediately on the right.
.4 HP/OIB/1009I023 Detailed Guide to All TLD Sample Locations Page 4 of 7 Site #153 Continue into MNS and head toward the setting ponds/land farm area. Circle around the settling ponds and pass the air site (#125) on the left. Proceed to OC gate #4 and approximately 100 feet from the gate is a clearing on the left. The TLD is located on a stake in the clearing.
Site #154 Drive vehicle back around setting ponds toward the land farm area and turn left on the first gravel road and proceed through QC gate #5. Drive to where the road forks. Take the left fork and down the next gravel/dirt road on your right, you may drive directly to the level grassy area near the riverbank edge. The TLD is on a stake near the riverl~ank edge approximately 3/4 of the way down the length of the rocky bank just past the control monument.
Site #190 Continue along the riverbank follow the tree line away from the river until you see a "dangerous water" sign. Continue forwards approximately 300 yards to the tree with a
-painted red dot on it. The TLD is on a stake.
Site #156 Drive the vehicle back up the hill toward warehouse #5. Make a left turn just before you get to warehouse #5 and go up toward the intake structures. The road heads toward MNS and then makes a hairpin turn back toward the dam. Drive all the way to the edge of Cowan's Ford Dam and the TLD is located to the left of the cement wall on a stake.
Site #196 Return to Hwy 73 and turn left. Turn right at MNS Garage Access Road and proceed past garage to dirt road on the right. Drive down dirt road past electrical switch yard to the MNS landfarm on the left. The landfarm is fenced in and the TLD is on the fence adjacent to the road. NOTE: TLD #196 replaces old TLD #LF2.
Site #197 Proceed down dirt road to the landfill. The TLD is located to the left of the gate to the landfill.
Site #198 Proceed back toward garage and take dirt road to left. Drive to road ends at old landfill gate. TLD is at top of hill to the right of the gate.
Site #199 Drive through gate to back side of the landfill. You will see a groundwater well (MW
- 1) near the back gate. The TLD is at MW-1 on a steel post.
Site #191 Return to Hwy 73 and turn right. Drive toward Cornelius and take a left on Jetton Rd.
Drive to John Connor Rd. and take a left onto it. Drive a short distance to the CMUD pumping station on the left. The TLD is on the air sampler environmental house inside the fenced pumping station (air site # 192).
Site #158 Return to Hwy 73 and turn left. Proceed to Bethel Church Rd. (SR 2189) and turn left.
Proceed to Staghorn Rd. The TLD is located on a utility pole at the intersection of Bethel Church Road and Staghorn Road.
.4 HPIOIlo1009/023 Detailed Guide to All TLD Sample Locations Page 5 of 7 Site #159 Return to Hwy 73. Turn left and make a sharp left turn onto Henderson Rd. Drive to the end of that road. The TLD is on the oak "NRC Tree" by the water.
Site #160 Return to Hwy 73 and turn left. Follow 73 east to Hwy 21 South, turn right and go to the Anchorage Marine Showroom, which will be on the left. The TLD is located on the chain link fence in front of the parking lot.
Site #161 Return to Hwy 73 and turn left. Continue to the intersection of 21 and Sam Furr Rd.
The TLD is located on the back of the Energy Explorium sign to the right.
Site #178 Continue on Hwy. 21 (heading south) and go until you intersect with Gilead Road.
Turn left onto Gilead Road. Proceed to the intersection of Gilead and Old Statesville Road (Hwy. 115) and turn right. Keep going past North Mecklenburg High School and continue to the "Croft Community" sign (which will be on your right). Immediately after this sign on your right is a dirt road. Turn right and this is the entrance to the Duke Power substation @ Florida Steel Corp. Use a DPC #2 key to gain access down the road. The TLD is on a stake to the left of the road approximately 100 yards past the entrance gate.
Site #163 Return to Hwy.1 15. and turn left, proceed to SR #2117 (Hambright Road). Turn left (directly in front of Alexander Jr. High School) and proceed to McCoy Rd. (-3.0 miles). The TLD is located on the telephone pole (beside the NRC TLD) at the residence.
Site #164 Turn around on McCoy Rd. then turn right on Hambright Rd. Come to the intersection of Hambright and Beatties Ford Road. The TLD is located on the left side of the road on a telephone pole.
Site #162 Turn right onto Beatties Ford Rd. and proceed to Bud Henderson Rd., turn right. Go to Gilead Rd. and turn right. Proceed to Ranson Rd. (SR #2139, this road is in a sharp curve) and turn left. TLD is on the second pole on the left near an electric fence.
Site #182 Return to Gilead Rd. and turn left. Travel forward over 1-77. Turn left onto Old Statesville Road and go to Cornelius. TLD is inside cage at air sampler site #133.
Site #181 Travel on to Davidson water treatment plant. The TLD is on a power pole in the front of the plant.
Site #157 From Davidson water treatment plant, go to stop sign and turn left onto Gamble St. Go one block and turn right onto Jetton St. Follow until road ends, turn left and you will see 1-77 to your right. Take 1-77 North to exit 33, Hwy. 21N. Turn left. Proceed until you come to Brawley School Rd. (there will be a church on your right just before the intersection where you will be turning left.) Follow Brawley School Rd. which eventually turns into Mayhew Rd. past Mallard Head Country Club until the road dead ends (- 8 mi.). The TLD is located on a utility pole in the right rear yard.
.4 HP/0/B/1009/023 Detailed Guide to All TLD Sample Locations Page 6 of 7 Site #180 Go back to intersection of Brawley School Rd. and Hwy 21. Cross straight over 21 towards Mooresville. At Hwy 21N, turn left and continue to Mooresville water treatment plant. The TLD is located on a utility pole to the right of the driveway.
Site #173 Return to Hwy 21-South and turn right. Proceed approximately 1/2 mile and veer to your right to Hwy. 150 west. Proceed past Marshall Station to the intersection of SR 1899 and 150 and turn left. This will be SR 1899 Slanting Bridge Rd. Continue to Keistler's Store Rd. and turn left. Follow this road to Mountain Shore Lane, turn left (across from the two-story beige house). Next turn left onto Glenwood Rd. The TLD is located on the first power pole in the front yard of the first house on the left.
Site #172 Return to Slanting Bridge Rd. Turn left and continue to Hwy. 16. Turn left and go to Fairfield Rd. (-3.3 miles) on the left in the Westport Community and turn left (SR 1389). Take the first left onto North Golf Course drive which turns into Lakeshore Drive. At the intersection of Golf Course Drive and Lakeshore Drive. The TLD is on the utility pole to the right @ 625 Golf Course Dr.
Site #171 Return to Hwy 16-South, turn left. TLD is on the utility pole on the north side of the Triangle Ace Hardware (which will be on the left).
Site #170 Return to Hwy. 16 and turn left. Proceed to the intersection of Hwy. 16 and 73. Turn right onto 73 and turn left onto Little Egypt Rd. The TLD is on the 2nd utility pole on the right.
Site #174 Return to Hwy. 73 and turn left. Go to East Lincoln Jr. High School. The TLD is located in the air sampling cage at air sampling site #134.
Site #175 Return to Hwy. 73 and turn right. Go to Boger City. Hwy. 73 runs into Hwy. 27. Go straight to the first light and turn right on to Buffalo Shoals Rd. Proceed until you come to SR 1332 (Highland Rd.) and turn left. Follow to Hoyle Road on your right and turn right. Go to 208 Hoyle Road. TLD is on the fence beside the house.
Site #168 Return to Hwy. 73 and go back past East Lincoln Jr. High School, take a right on Old Plank Road. Go approximately 5 miles until you cross a bridge. The TLD is located on a utility pole on the right just after crossing the bridge.
Site #177 Return to Hwy 73 and continue to stop light at Hwy.16. Turn right on to Hwy 16 and proceed to Rozzelles Ferry Road (old Hwy.16) and take a right. Rozzelles Ferry turns into Belhaven Blvd. Go to a green Coulwood School sign. Turn right at this sign.
This is Kentberry Rd. Continue - one block and turn left onto Belmarrow Dr. The TLD is located @ 908 Belmarrow Rd. on a safety light pole at the driveway entrance to the left.
.4 HP/O/B/1009/023 Detailed Guide to All TLD Sample Locations Page 7 of 7 Site #166 Return to Hwy. 16 and turn right. Continue to the Catawba River. After crossing the bridge, turn right at Steam Plant Rd. and follow this road to Riverbend Steam Station.
Continue on Horseshoe Bend Beach Rd. to the water tower that is across the road directly in front of the steam station. The TLD is on the fence which surrounds the water tower.
Site #165 Continue down the road, away from Hwy. 16, - 1 mile to a real sharp curve in the road. There'll be a dirt area on your left where you can pull over at a barricade. The TLD is on utility pole to the left of the barricade.
Site #167 Return to Hwy. 16. At the light, go straight and proceed to the building at 14522 Lucia Riverbend Highway on the right. The TLD is located on a power pole that supplies the building.
Site #169 Return to Hwy. 16 and turn left. Proceed to Hill's Chapel United Methodist Church on the left. Just past the church is a dirt road (Glover Lane), turn left and go to the end of this road. The TLD is located on a utility pole on the right.
.5 List of Designated Milk Sample Locations HIP/O/BIl 009/023 Page 1 of 1 This enclosure is meant to provide a guide to one who is NOT familiar with the environmental milk sample route. Appropriate deviations from this sequence and route may be made as necessary.
MILK SAMPLES A. Sample location numbers:
139 - William Cook Dairy 138 - Henry Cook Dairy 140 - David Kidd Dairy 141 - Lynch Dairy B. Directions to sampling locations:
Location #139 William Cook Dairy Location #138 Henry Cook Dairy Location #140 Kidd's Dairy Location 141 Lynch Dairy Turn left when leaving MNS main entrance and proceed to Oliver Hager Rd. (SR #2142) on your right. Follow road to the large main house. Behind the house is a garage storage area. The milk will be in a refrigerator in the garage area.
Return to Hwy. 73 and turn left. Proceed to Beatties Ford Rd.
(Rd. beside Phillips 73 General Store) and turn left. Follow Beatties Forc] Rd. approximately.5 miles to Gilead Rd. Turn left. Follow Gilead Rd. approximately 4 mi. to Ervin Cook Rd. Turn left. Henry Cooks Dairy will be the second dairy on your left, approx. 1 mi. It will be on your left just before the road ends. The milk will be in a refrigerator in the white wooden building on your right.
Return to Beatties Ford Road and make a left.
Proceed to Jim Kidd Road (approximately 1.0 miles) and turn right.
Proceed approximately.5 of a mile and look for a white house on the right. Follow the dirt road to the rear of the house. The millk sample is taken from the vat located in the block building behind the house.
From ASC turn right onto Hwy. 73. Follow Hwy. 73 until it intersects with Hwy. 27. Follow Hwy. 27 into Boger City to SR
- 1003 (Buffalo Shoals Road) and turn right. The Lynch residence is 5.4 miles on the right (yellow frame house).
.6 HP/O/B/1009/023 Directions for Predetermined Page 1 of 10 Survey/Sampling Locations Example:
A 2
1 Evacuation Mile Sample Zone Radius A-2-1 From the intersection of Hwy. 73 and Jetton Road (SR2151), go west on Jetton Road 2.0 miles. Turn left onto John Connor Rd. and go 1.0 miles. Turn right on Belle Isle Dr. (SR2331) and go to the end of the road.
tj A-3-1 From the intersection of Hwy. 73 and Jetton Road (SR2151), go west on Jetton 3.8 miles to dead end.
A-3-2 From the intersection of Hwy. 73 and Jetton Road (SR2151), go west on Jetton Road 2.1 miles to the intersection of Jetton Road and North Beatties Ford Rd. Go to end of road and turn right.
A-3-3 From the intersection of Hwy. 73 and Nantz Road (SR2148), go west on Nantz Road. Go to end of Nantz Road.
A-5-1 Take 1-77 north to exit 33, turn left on Williamson Road (SRI 109). Turn left on Brawley School Road (SRI 100), go west 8.0 miles on Brawley School Road to dead end at water.
NOTE: Brawley School Road becomes Mayhew Road at Meckenburg County Line.
A-5-2 From the intersection of Hwy. 73 and Bethel Church Road (SR2189), go north on Bethel Church Road to the end of Bethel Church Road.
A-5-3 From the main plant entrance, go east on Hwy. 73 (6.4 miles) to the intersection of Hwy. 73 and Henderson Road (SR2307).
A-6-1 From the intersection of Williamson Road (SRI 109) and Brawley School Road (SRI 109),
go west 6.9 miles on Brawley School Road. Turn left on Torrence Chapel Road (SR2065),
go 0.4 miles. Stop on roadside. NOTE: Brawley School Road becomes Mayhew Road at Mecklenburg County Line. Torrence Chapel Road is the first left after the county line.
B-I-1 One mile from plant on Lake Norman. (WNW)
B-1-2 One mile from plant on Lake Norman. (NW)
B-1-3 One mile from plant on Lake Norman. (NNW)
B-1-4 One mile from plant on Lake Norman. (N)
B-1-5 One mile from plant on Lake Norman. (NNE)
B-1-6 Emergency Boat House and dock.
One and /2 miles from plant on Lake Norman directly east of TTC. (NE)
B-1-7
.6 HP/0/B/1009/023 Directions for Predetermined Page 2 of 10 Survey/Sampling Locations B-1-8 One and 1/4/ miles from plant on Lake Norman (NE) at mouth of discharge canal.
B-l-9 One and 1/2 miles from plant on Lake Norman (ENE).
B-i-10 Bridge over discharge canal on road to TrC.
B4-I-11 The intersection of U-2 access road and the road to TI'C.
j B-1-12 On the roadside of U-2 access road.2 miles off of Hwy. 73.
B-1-13 The intersection of Hwy. 73 and the U-2 access road.
B-1-14 The intersection of Hwy. 73 and the access road to the firing range.
B-i-15 U-1 main entrance.
B-1-16 Right past the bridge on Hwy. 73 over the Catawba River (below the dam).
B-1-17 The east side of Cowans Ford Dam, access through O.C. Gate #5 (lower dam access).
B-1-18 At the intake structure.
B-2-1 2 miles from plant on Lake Norman (NE).
B-2-2 From McGuire main entrance, go east on Hwy. 73 (2.5 miles). Turn left on Terry Lane (SR2255). Go 0.5 miles to the end of Terry Lane (SR2255).
B-3-1 From McGuire main entrance, go east on Hwy. 73 (3.8 miles). Turn left on Norman Island Drive (SR2145). Go to the end of Norman Island Drive.
C-1-1 At the intersection of Hubbard Road and Hwy. 73 turn on Hubbard Road (SR2134) and stop on roadside.
C-1-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south 1.3 miles on Beatties Ford Road. Turn right onto Cashion Road (SR2133), go to end of road.
C-2-1 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south 1.3 miles on Beatties Ford Road to the intersection of Beatties Ford Road and Cashion Road (SR2133).
C-2-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south 1.5 miles on Beatties Ford Road. Turn right on Stephens Road (SR2132), go.7 miles to dead end at gate.
D-2-1 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south.3 miles on Beatties Ford Road to the intersection of Beatties Ford Road and Gilead Road (SR2136).
.6 HPIOIBI1009I023 Directions for Predetermined Page 3 of 10 Survey/Sampling Locations D-3-1 From McGuire main entrance go east on Hwy. 73 (3.8 miles) to first stoplight. Cashion's convenience store parking lot on Hwy. 73.
D-3-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go.3 miles south on Beatties Ford Road. Turn left on Gilead Road (SR2136), go 1.2 miles to the intersection of Gilead Road and Bud Henderson Road (SR2131).
D-3-3 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 2.4 miles to the intersection of Beatties Ford Road and Jim Kidd Road (SR2129).
D-3-4 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 3.5 miles. Turn right on Neck Road (SR2074), go 2.4 miles to the intersection of Neck Road and Allison Ferry Road (SR2127).
D-3-5 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 3.5 miles. Turn right on Neck Road (SR2074), go 2.4 miles. Turn right on Allison Ferry Road (SR2127), go.7 miles to dead end.
D-5-1 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road.3 miles. Turn left on Gilead Road (SR2136), go 3.0 miles to the intersection of Gilead Road and Ranson Road (SR2139).
D-5-2 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 4.2 miles. Turn left on Hambright Road (SR2117), go 1.6 miles to the intersection of Hambright Road and McCoy Road (SR2120).
D-5-3 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 4.2 miles to the intersection of Beatties Ford Road and Hambright Toad (SR2117).
D-5-4 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 5.0 miles to the intersection of Beatties Ford Road and Sample Road (SR2125).
D-5-5 From the intersection of Beatties Ford Road (SR2128) and Hwy. 73, go south on Beatties Ford Road 3.5 miles. Turn right on Neck Road (SR2074), go 2.4 miles. Bear to left and continue 0.6 miles. Stop on roadside. Should see entrance to Cowan's Ford Waterfowl Refuge.
E-6-1 From the intersection of Beatties Ford Road (SR2128) and Mt. Holly Huntersville Road (SR2004), go west on Mt. Holly-Huntersville Road to the intersection of Mt.
Holly-Huntersville Road and Oakdale Road (SR2042).
E-7-1 From the intersection of Beatties Ford Road (SR2128) and Mt. Holly-Huntersville Road (SR2004), go west on Mt. Holly-Huntersville Road 3.2 miles to the intersection of Mt.
Holley-Huntersville Road and Pump Station Road (SR2001).
.6 HPIOBl10091023 Directions for Predetermined Page 4 of 10 Survey/Sampling Locations E-8-1 From the intersection of Beatties Ford Road (SR2128) and Miranda Road (SR2025), go west on Miranda Road to the intersection of Miranda Road and Sunset Road (SR2042).
E-8-2 From the intersection of Mt. Holly-Huntersville Road (SR2004) and Hwy. 16, go south on Hwy. 16 to intersection of Hwy. 16 and Pleasant Road (SR2008).
E-8-3 From the intersectioii of Mt. Holly-Huntersville Road (SR2004) and Hwy. 16, go west on Mt. Holly-Huntersville.8 miles to the intersection of Mt. Holly-Huntersville Road and Harwood Lane (SR1667) - directly across from Mountainair Road.
E-10-1 From the intersection of Beatties Ford Road (SR2128) and Sunset Road (SR2108), go west on Sunset.7 miles. Turn left on Peachtree Road (SR2019), go 1.3 miles to the intersection of Peachtree Road and Oak Road (SR2027).
E-10-2 From the intersection of Mt. Holly-Huntersville Road (SR2004) and Hwy. 16, go south on Hwy. 16 (1.5 miles). Turn right on Valleydale Road, then make an immediate right (50 ft.)
onto Gumbranch Road. Go.7 miles on Gumbranch. Turn left on Cathey Road, go 1.0 miles to the intersection of Cathey Road and Tom Saddler Road.
F-5-1 From the intersection of US21 and Gilead Road (SR2136), go south on US21 (.9 miles) to the intersection of US21 and Mt. Holly-Huntersville Road (SR2004).
F-7-1 From the intersection of US21 and Gilead Road (SR2136), go south on US21 (2.9) miles.
Turn right on Alexanderana Road (SR2116), go 1.0 miles to the intersection of Alexanderana Road and Mt. Holly-Huntersville Road (SR2004).
F-8-1 From the intersection of 1-77 and Gilead Road (SR2136) - Exit #23, go south to 1-77 to the intersection of 1-77 and Reames Road (SR21 10) - Exit #18.
F-9-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Continue straight on Huntersville-Concord Road (SR2426) 3.6 miles to the intersection of Huntersville-Concord Road and Hiwasee (this also may be called Huntersville-Concord Road).
F-9-2 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Continue straight on Huntersville-Concord Road (SR2426) 2.4 miles. Turn right on Asbury Chapel Road (SR2442), go 2.4 miles to the intersection of Asbury Chapel Road and Trails End Road (SR2445).
F-10-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn right on Hwy. 115, go 2.9 miles. Turn left on Alexanderana Road (SR2457), go
.9 miles. Turn left on Eastfield Road (SR2459), to 2.3 miles to the intersection of Eastfield Road and Prosperity Church Road (SR2475).
.6 HP/O/B/1009/023 Directions for Predetermined Page 5 of 10 Survey/Sampling Locations F-10-2 From the intersection of US21 and Gilead Road (SR2136), go south on US21 5.2 miles.
Turn left on Lakeview Road (SR2112), go 1.0 miles. Turn right on Hwy. 115, go.7 miles to the intersection of Hwy. 115 and Victoria Ave. (SR2631) Beachwood Mobile Home Park Road.
G-5-1 From the intersection of US21 and Gilead Road (SR2136), go north on US21 (3.8 miles) to the intersection of US21 and Westmoreland (SR2147).
G-5-2 From the intersection of US21 and Gilead Road (SR2136), go north on US21 (2.3 miles) to the intersection of US21 and Sam Furr Road (SR2145).
G-6-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go 3.7 miles to the intersection of Hwy. 115 and Bailey Road (SR2416).
G-6-2 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go 1.6 miles. Turn right on McCord Road (SR2427), go.3 miles.
Turn right on Hagers Road (SR243 8), go.5 miles to dead end.
G-8-1 From the intersection of US21 and Gilead Road (SR2136), go north on US21 (2.3 miles).
Turn right on Sam Furr Road (SR2145), go 3.9 miles. Turn left on Davidson-Concord Road and continue to intersection of Davidson-Concord Road and Rockey River Road (SR2420).
G-8-2 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go.7 miles. Turn right on Ramah Church Road (SR2439),
go 2.4 miles to the intersection of Ramah Chbrch Road and McCord Road (SR2427).
G-10-1 From the intersection of US21 and Gilead Road (SR2136), go east on Gilead Road.7 miles.
Turn left on Hwy. 115, go 2.0 miles. Turn right on Sam Furr Road (SR2145), go 2.7 miles.
Turn left on Davidson-Concord Road, go 2.3 miles. Turn right on Rocky River Road (SR2420), go 2.3 miles. Turn left on Shearer Road (SR2418), go 2.6 miles to the intersection of Sherarer Road and Fisher Road (SR2419).
H-6-1 From the intersection of US21 and Hwy. 73, to east on Hwy. 73.9 miles to the intersection of Hwy. 73 and Hwy. 115.
H-7-1 From the intersection of 1-77 and Hwy. 73 (Exit #28), go north on 1-77 to the intersection of 1-77 and Griffith Street (SR2158) (Exit #30).
H-7-2 From the intersection of 1-77 and Griffith Street (SR2158) Exit #30, go east on Griffith Street.9 miles to Sadler Square Shopping Center.
1-7-1 From the intersection of Brawley School Road (SRI 100) and Williamson Road (SRI 109),
go west on Brawley School Road 5.2 miles to the intersection of Brawley School Road and Garden Road (SRI 1111).
.6 HP/O/B/1009/023 Directions for Predetermined Page 6 of 10
' Survey/Sampling Locations 1-7-2 From the intersection of Brawley School Road (SR1I00) and Williamson Road (SR1109),
go west on Brawley School Road 2.7 miles. Turn left on Isle of Pines Road (SRI 113),
go 3.4 miles to dead end.
1-8-1-.
From the intersection of Brawley School Road (SR1100) and Williamson Road (SR1109),
go west on Brawley School Road 3.8 miles. Turn right on Chuckwood Road (SRI 177), go to end.
1-9-1 From the intersection of Brawley School Road (SRi 100) and Williamson Road (SR1109),
go west on Brawley School Road 3.8 miles to the intersection of Brawley School Road and Chuckwood Road (SRi 177).
1-10-1 From the intersection of Brawley School Road (SR1l00) and Williamson Road (SR1109),
go west on Braviley School Road 3.2 miles. Turn right onto McKendries Road (SR1 115),
go 1.6 miles to the intersection of McKendries Road and Lakeview Drive (SR1455).
J-7-1 From the intersection of 1-77 and US21 (Exit #33), go west on US21 over 1-77 (.2 miles).
Turn left on Alcove Road (SR1206), go 1.8 miles. Turn right on Langtree Road (SR1102),
go 2.0 miles to entrance Alexander Island.
J-9-1 From the intersection of 1-77 and Griffith Street (Exit #30), go east on Griffith Street (SR2158) 1 mile. Turn left on Hwy. 115, go 1.4 miles to the intersection of Hwy. 115 and Midway Lake Road (SRI 137).
J-10-1 From the intersection of 1-77 and US21 (Exit #33), go west on US21 over 1-77 (.2 miles).
Turn left on Alcove Road (SR1206) then bear right on Catalina Road (SRI 110) go.6 miles.
Bear right on Malibur Road (SR1194) go.4 miles to dead end at Cul-de-sac.
J-10-2 From the intersection of 1-77 and US21 (Exit #33), go east on US21 (.1 miles). Turn right on Fairview Road (SR1246), go.9 miles. Turn right on Hwy. 115, go.3 miles. Turn left at Faith Road (SR1136), go.8 miles to the intersection of Faith Road and Midway Lake Road (SRi 137).
K-9-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 6.6 miles. Turn right on Campground Road (SR1373), go 2.8 miles to the intersection of Slanting Bridge Road (SRI 373) and Keistler Store Road (SRi 899).
NOTE:
Campground Road turns into Slanting Bridge Road at Catawba County Line.
K-9-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 6.6 miles. Turn right on Campground Road (SR1373), go 4:8 miles. Turn right on Hwy. 150, go 1.7 miles. Turn right on Kiser Island Road (SR1841), go 3.1 miles to dead end at circle.
.6 HP/OB/1009/023 Directions for Predetermined Page 7 of 10 Survey/Sampling Locations NOTE:
Campground Road turns into Slanting Bridge Road at Catawba County Line.
L-1-1 From the McGuire main entrance, go west on Hwy. 73 (.5 miles) to the Cowans Ford Dam.
L-1-2 From the McGuire main entrance, go west on Hwy. 73 (1.4 miles). Turn right onto Cowans Ford Road (SR1395), go.8 miles.
L-2-1 From the McGuire main entrance go 1.4 miles to the intersection of Hwy. 73 and Cowans Ford Road (SR 1395).
L-2-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (0.6 miles). Turn right onto Hagers Ferry Road (SR1393) and go 1.4 miles. Go straight on paved road (Lucky Point) 0.4 miles.
M-1-1 From the McGuire main entrance, go west on Hwy. 73 (0.9 miles) to the intersection of Hwy. 73 and Caswell Road (SR1578).
M-2-1 From the McGuire main entrance, go west on Hwy. 73 (2.3 miles). Turn left onto Killian Road (SR1396), go 2.2 miles. Stop on roadside of railroad crossing.
N-2-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (.6 miles). Turn right onto Hagers Ferry Road (SR1393), go 1.4 miles. Go left onto Hager's Ferry Road (SR1393),
go 1.6 miles to where pavement ends residence 8886 Hager's Ferry Rd.
N-3-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (.6 miles). Turn right onto Hagers Ferry Road (SR1393), go.9 miles to the intersection of Hagers Ferry Road and Nixon Heights, Lane (SR 1568).
N-3-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (2.1 miles). Turn right on Unity Church Road (SR1439), go.3 miles. Turn right on Graham Road, go 1.6 miles to end of road.
N-4-2 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (2.1 miles). Turn right on Unity Church road (SR1439), go 2.4 miles to Beatties Ford Access Area.
N-5-1 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (3.2 miles). Turn right on Lakeshore Drive (SR1456) go 1.3 miles. Turn right on Island View Court (SR1495) go
.1 miles to dead end.
0-3-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (2.0 miles). Turn left on Sifford Road (SR1397), go 1.2 miles to the intersection of Sifford Road and Mac Lane (SR 1710).
0-4-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (1.2 miles). Stop on roadside at Hills Chapel United Methodist Church.
.6 HP/OIB/lO09/023 Directions for Predetermined Page 8 of 10
'Survey/Sampling Locations 0-4-2 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (.6 miles) to the intersection of Hwy. 16 and Pilot Knob Road (SR1394).
0-5-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (2.2 miles). Turn right on Old Plank Road (SR151 1), go 1.0 miles. Stop on roadside past bridge.
P-5-1 From the intersection of Hwy. 73 an Hwy. 16, go west on Hwy. 73 (1.5 miles) to the intersection of Hwy. 73 and Little Egypt Road (SR1386).
P-5-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (1.5 miles). Turn right on Little Egypt Road (SR1386), go 1.9 miles. Turn right on Optimist Club Road (SR1380),
go about.6 miles. Stop near creek.
P-6-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (3.6 miles). Turn right on Schroncd'Ro~ad (SR1385). Go to intersection of Schronce Road (SR1385) and Ingleside Farm Road (SR1383).
P-6-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (1.5 miles). Turn right on Little Egypt Road (SR1386), go 3.2 rmiles to the intersection of Little Egypt Road which is now St. James Church Road - SR1380) and Kidville Road (SR1381).
P-6-3 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (4.9 miles). Turn right on Webb's Chapel Road (SR1379), go 1.6 miles to the intersection of Webb's Chapel Road and Burton Road.
P-8-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (5.3 miles). Turn right on Beth Haven Church Road (SR1360), go 1.4 miles. Stop on roadside past bridge.
P-8-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (2.5 miles): Turn right on Ingleside Farm Road (SR1383), go.1 mile and bear left 3.2 miles more. Turn right on Beth Haven Church Road (SR1360), go 1.3 miles. Turn right on Forney Hill Road (SR1373), go.7 miles. Stop on roadside passed bridge.
P-8-3 From the intersection of Hwy. 73 and Hwy. 16, go north on Hwy. 16 (7.8 miles) to the intersection of 16 and SR1373 (Campground Road or Slanting Bridge Road). Turn right on this road and go about 1.8 miles to the intersection of SR1373 and Pineridge Drive (SR1375).
P-10-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (6.8 miles) to the intersection of Hwy. 73 and Amity Church Road (SR1362).
P-10-2 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (2.5 miles). Turn right on Ingleside Farm Road (SR1383), go.1 miles and bear left 3.2 miles more. Turn right on Beth Haven Church Road (SR1360), go 2.8 miles to the intersection of Beth Haven Church Road and Mundy Road (SR1349).
.6 HPI0OB1 10091023 Directions for Predetermined Page 9 of 10 Survey/Sampling Locations Q-6-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (2.5 miles). Turn right on Ingleside Farm Road (SR1383), go.1 mile bear right and go 1.7 miles more. Turn left on Old Plank Road (SR151 1), go.6 miles to the intersection of Old Plank Road and Mariposa (SR1412).
--Q-8-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73 (5.3 miles). Turn left on Brevard Place road (SR1360), go.1 mile. Turn left on Old Plank Road (SR1511),
go 1 mile. Turn right on Mt. Zion Church Road (SR1404), go 1.9 miles. Stop on road side pass the bridge.
Q-8-2 From the intersection of Hwy. 73 and Hwy. 16, to west on Hwy. 73 (5.3 miles). Turn left on Brevard Place Road (SR1360), go.1 miles. Turn left on Old Plank Road (SR151 1),
go 1.0 miles to the intersection of Old Plank Road and Mt. Zion Church Road (SR1404).
Q-10-1 From the intersection of Hwy. 73 and Hwy. 16, go west on Hwy. 73_(5.3 miles). Turn left on Brevard Place Road (SR1360), go 3.4 miles to the intersection of Brevard Place Road and Paysour Road (SR1361).
R-3-1 From the main entrance to McGuire go west on Hwy. 73 (2.3 miles). Turn left on Killian Road (SR1396), go 3.4 miles. Stop on roadside (just past Gaston County sign).
R-5-1 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (7.2 miles). Turn left on Horseshoe Bend Beach Road (SR1912), go 2.0 miles. Stop on roadside passed curve.
R-5-2 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (7.2 miles). Turn left on Horseshoe Bend Beach Road (SR1912), go 1.0 miles. Stop on roadside.
R-5-3 From the intersection of Hwy. 73 and Hwy. 16, go south on Hwy. 16 (7.2 miles) to the intersection of Hwy. 16 and Horseshoe Bend Beach Road (SR1912).
R-5-4*
From the intersection of Hwy. 73 and Hwy. 16, go south on HMvy. 16 (4.1 miles) to the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905).
S-7-1*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 2.0 miles. Stop on roadside at Macedona Church parking lot.
S-7-2*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 1.1 miles. Turn right on Alexis-Lucia road (SR1820),
go 1.6 miles to intersection of Alexis-Lucia Road and Old Lowesville Road (SR 1907).
S-8-1*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go south on old Hwy. 16 (2.0 miles). Turn right on Hwy. 273, go to the intersection of Hwy. 273 and Sand Ford Road (SR1918).
.6 HP/0/I1009/023 Directions for Predetermined Page 10 of 10 Survey/Sampling Locations S-8-2*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 3.2 miles. Go left at curve and continue 1.5 miles to the intersection of SR1935 and Old NC 27 (SR1923).
S-8-3.
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 3.2 miles. Go left at curve and continue.7 miles to the intersectiond of Stanley-Lucia Road and Sandy Ford Road (SR1918).
S-8-4*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 1.1 miles. Turn right on Alexis Lucia (SRI 820),
go 2.2 miles to the intersection of Alexis-Lucia Road and Mariposa Road (SR1902).
S-9-1*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go west on Stanley-Lucia Road 1.1 miles. Turn right on Alexis Lucia Road (SRI 820),
go 2.2 miles. Turn left on Mariposa (SR1902), go 1.5 miles. Turn right on Airport Road (SRI 903), go.6 miles to the intersection of Airport Road and Hwy. 27.
S-10-2*
From the intersection of old Hwy. 16 and Stanley-Lucia Road (Blacksnake Road-SR1905),
go south on old Hwy. 16 2.0 miles. Turn right on Hwy. 273, go 4.7 miles to the intersection of Hwy. 273 and N. Main Street.
NOTE:
Old Hwy. 16 (Lucia Rivelbend Hwy.) can be reached by turning right at the intersection of Hwy. 16 and Lucia Riverbend Hwy. which is 4.1 miles south on 16 from the Hwy. 73 and Hwy. 16 intersection.{* I'
.7 Field Monitoring Survey Data Sheet HP/O/B/1009/023 Page 1 of 1 Periodic Status Update for Field Monitoring Teams Date Time Emergency Wind Speed Wind Direction Zones Affected Other Information Classification mph from° I
I I
4 1
+/-
I I
I I
I t
I I
I I
-I I
-t I
I I
I 1
- 4.
- 4.
+
I
- 4.
- 4.
- 4.
I
+
t
- 4.
4-
+
1 1
1
- 4.
- 4.
-F I
I
_ I I_
IL I__
I__
( rI HP/O/B/I009/023 Page 1 of I
.9 HPI/OJIl1009/023 Vehicle Refueling Page I of 1
- 1. Pull in at the fueling island located at the McGuire Garage. The garage is located on the right side of the access road to the McGuire switchyard.
1
- 2.
Place the special refueling key in the pump control station. The control station is located on a vertical steel beam which is located between the gas pump and the diesel pump.
- 3.
Remove the key, and follow the instructions as they appear on the control station. The instructions include:
- a.
Enter the vehicle's mileage.
- b.
Enter the pump being used; 1 for gas, and 2 for diesel.
- c.
Enter your social security number.
- 4. Remove the nozzle, turn the pump on, and refuel the vehicle.
- 5.
WHEN finished, turn the pump off, and return the nozzle to the pump.
The refueling pumps are opened 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per day, 7 days a week. The McGuire Garage has personnel working in the garage from 7:30 AM to 12:00 AM Monday through Friday. Call Security from the garage gate phone to gain access to the pumps after hours or on weekends or holidays.
IF oil, antifreeze, or windshield washer fluid is needed, see McGuire Garage personnel.
.10 FMT Turnover Checklist Copies of Enclosure 5.3 from HP/O/B/10091027.
Latest copy of Enclosures 5.7 and 5.8 from HPOJB/10091023.
List sampling van or emergency kit supplies needed.
HPIOIBIl O09/023 Page 1 of 1
- 4.
List Inoperable Equiprnent.
- 5.
List any Sampling Problems.
- 1.
- 2.
3.
I
.11 Obtaining Meteorological Data from SDS HP/0/B/1009/023 Page 1 of 1 NOTE:
IF a computer is NOT available in the OSC, Meteorological Data may be obtained from any other LAN based computer or from the OSC Radiation Protection Supervisor.
- 1. From any LAN based computer:
-a. Select DAE
`b. Select Department Apps
- c. Select Nuclear Generation
- d. Select McGuire Desktop
- 2.
Select McGuire Process Data.
- 3.
Select SDS.
- 4. At the SDS screen, select either Unit-i or Unit-2. For drills, select Simulator.
- 5.
Type in GD ERORD 5.
- 6.
Obtain 10 meter (lower) wind speed and 60 meter (upper) wind direction from page 1 of 3.
Other MET Data (temperature and precipitation) is also found on page 1 of 3.
- 7.
Use the 10 mile EPZ map and 90' plume marker located in the OSC to assist in determining where plume edge could be encountered. The plume marker will indicate 45' to either side of centerline wind direction.