|
---|
Category:License-Monthly Operating Report
MONTHYEARL-2006-004, January 2006 Monthly Operating Report for Turkey Point Units 3 & 42006-02-13013 February 2006 January 2006 Monthly Operating Report for Turkey Point Units 3 & 4 L-2005-253, November 2005 Operating Report, Turkey Point, Units 3 and 42005-12-14014 December 2005 November 2005 Operating Report, Turkey Point, Units 3 and 4 L-2005-235, October 2005 Monthly Operating Report for Turkey Point, Units 3 and 42005-11-15015 November 2005 October 2005 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2005-216, September 2005 Monthly Operating Report for Turkey Point Units 3 and 42005-10-0707 October 2005 September 2005 Monthly Operating Report for Turkey Point Units 3 and 4 L-2005-197, August 2005 Monthly Operating Report for Turkey Point Units 3 and 42005-09-13013 September 2005 August 2005 Monthly Operating Report for Turkey Point Units 3 and 4 L-2005-182, July 2005 Operating Report for Turkey Point Units 3 and 42005-08-15015 August 2005 July 2005 Operating Report for Turkey Point Units 3 and 4 L-2005-156, June 2005 Monthly Operating Report for Turkey Point Units 3 & 42005-07-13013 July 2005 June 2005 Monthly Operating Report for Turkey Point Units 3 & 4 L-2005-133, May 2005 Monthly Operating Report for Turkey Point Units 3 & 42005-06-13013 June 2005 May 2005 Monthly Operating Report for Turkey Point Units 3 & 4 L-2005-118, April 2005 Monthly Operating Report for Turkey Point Units 3 and 42005-05-16016 May 2005 April 2005 Monthly Operating Report for Turkey Point Units 3 and 4 L-2005-084, March 2005 Monthly Operating Report for Turkey Point Units 3 and 42005-04-14014 April 2005 March 2005 Monthly Operating Report for Turkey Point Units 3 and 4 L-2005-061, February 2005 Monthly Operating Report for Turkey Point Units 3 and 42005-03-11011 March 2005 February 2005 Monthly Operating Report for Turkey Point Units 3 and 4 L-2005-039, January 2005 Monthly Operating Report for Turkey Point, Units 3 and 42005-02-14014 February 2005 January 2005 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2005-009, December 2004 Monthly Operating Report for Turkey Point, Units 3 and 42005-01-13013 January 2005 December 2004 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2004-284, November 2004 Monthly Operating Report for Turkey Point, Units 3 and 42004-12-15015 December 2004 November 2004 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2004-260, October 2004 Monthly Operating Report for Turkey Point Units 3 and 42004-11-10010 November 2004 October 2004 Monthly Operating Report for Turkey Point Units 3 and 4 L-2004-226, September 2004 Monthly Operating Report for Turkey Point Units 3 and 42004-10-13013 October 2004 September 2004 Monthly Operating Report for Turkey Point Units 3 and 4 L-2004-183, July 2004 Monthly Operating Report for Turkey Point Units 3 and 42004-08-11011 August 2004 July 2004 Monthly Operating Report for Turkey Point Units 3 and 4 L-2004-165, June 2004 Monthly Operating Report for Turkey Point Units 3 and 42004-07-15015 July 2004 June 2004 Monthly Operating Report for Turkey Point Units 3 and 4 L-2004-106, April 2004 Monthly Operating Report for Turkey Point, Units 3 and 42004-05-13013 May 2004 April 2004 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2004-080, March 2004 Monthly Operating Report for Turkey Point, Units 3 & 42004-04-0808 April 2004 March 2004 Monthly Operating Report for Turkey Point, Units 3 & 4 L-2004-039, January 2004 Monthly Operating Report for Turkey Point, Units 3 and 42004-02-13013 February 2004 January 2004 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2004-006, December 2003 Monthly Operating Report for Turkey Point, Units 3 and 42004-01-14014 January 2004 December 2003 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2003-302, November 2003 Monthly Operating Report for Turkey Point Units 3 and 42003-12-12012 December 2003 November 2003 Monthly Operating Report for Turkey Point Units 3 and 4 L-2003-284, October 2003 Monthly Operating Report for Turkey Point, Units 3 and 42003-11-17017 November 2003 October 2003 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2003-256, September 2003 Monthly Operating Report for Turkey Point Units 3 & 42003-10-0909 October 2003 September 2003 Monthly Operating Report for Turkey Point Units 3 & 4 L-2003-229, August 2003 Monthly Operating Report Turkey Point Units 3 and 42003-09-11011 September 2003 August 2003 Monthly Operating Report Turkey Point Units 3 and 4 L-2003-205, July 2003 Monthly Operating Report for Turkey Point Units 3 & 42003-08-12012 August 2003 July 2003 Monthly Operating Report for Turkey Point Units 3 & 4 L-2003-173, June 2003 Monthly Operating Report for Turkey Point, Units 3 & 42003-07-10010 July 2003 June 2003 Monthly Operating Report for Turkey Point, Units 3 & 4 L-2003-148, May 2003 Monthly Operating Report for Turkey Point Units 3 & 42003-06-11011 June 2003 May 2003 Monthly Operating Report for Turkey Point Units 3 & 4 L-2003-120, April 2003 Monthly Operating Report for Turkey Point Beach Units 3 & 42003-05-14014 May 2003 April 2003 Monthly Operating Report for Turkey Point Beach Units 3 & 4 L-2003-089, March 2003 Monthly Operating Report for Turkey Point Units 3 & 42003-04-15015 April 2003 March 2003 Monthly Operating Report for Turkey Point Units 3 & 4 L-2003-058, February 2003 Monthly Operating Report for Turkey Point, Units 3 & 42003-03-10010 March 2003 February 2003 Monthly Operating Report for Turkey Point, Units 3 & 4 L-2003-031, January 2003 Monthly Operating Report for Turkey Point Units 3 & 42003-02-13013 February 2003 January 2003 Monthly Operating Report for Turkey Point Units 3 & 4 L-2003-003, December 2002 Monthly Operating Report for Turkey Point Units 3 & 42003-01-13013 January 2003 December 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-240, November 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-12-12012 December 2002 November 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-223, October 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-11-11011 November 2002 October 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-203, September 2002 Monthly Operating Report for Turkey Point, Units 3 and 42002-10-0808 October 2002 September 2002 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2002-181, August 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-09-11011 September 2002 August 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-158, July 2002 Monthly Operating Report for Turkey Point Units 3 and 42002-08-14014 August 2002 July 2002 Monthly Operating Report for Turkey Point Units 3 and 4 L-2002-136, June 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-07-15015 July 2002 June 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-107, May 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-06-10010 June 2002 May 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-099, April 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-05-13013 May 2002 April 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-068, March 2002 Monthly Operating Report for Turkey Point Units 3 & 42002-04-0808 April 2002 March 2002 Monthly Operating Report for Turkey Point Units 3 & 4 L-2002-051, February 2002 Monthly Operating Report for Turkey Point, Units 3 & 42002-03-11011 March 2002 February 2002 Monthly Operating Report for Turkey Point, Units 3 & 4 L-2002-031, January 2002 Monthly Operating Report for Turkey Point, Units 3 and 42002-02-12012 February 2002 January 2002 Monthly Operating Report for Turkey Point, Units 3 and 4 L-2002-005, December 2001 Monthly Operating Report for Turkey Point, Units 3 and 42002-01-0404 January 2002 December 2001 Monthly Operating Report for Turkey Point, Units 3 and 4 2006-02-13
[Table view] |
Text
AUG 1 4 2002 FPL L-2002-158 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 Monthly Operating Report - July 2002 In accordance with the requirements of Turkey Point Units 3 and 4 Technical Specification 6.9.1.5, and the guidance of Generic Letter 97-02, attached are the July 2002 Operating Data Reports and Summaries of Operating Experience for Turkey Point Units 3 and 4.
Very truly yo/us, John P.J~Elwain Vice President Turkey Point Plant OIH Attachments NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC.
an FPL Group company
. J DOCKET NO.: 50-250 UNIT: Turkey Point Unit 3 DATE: 8/5/2002 COMPLETED BY: Olga Hanek TELEPHONE: (305) 246-6607 Reporting Period July, 2002 OPERATING DATA REPORT Design Electrical Rating (MWe-Net) 720 __........ _ .......
Maximum Dependable Capacity (MWe-Net) 693 _ _ _
Month Year-to-date Cumulative No. of hours reactor was critical 744 5087 190866.8 No. of hours generator was on line (service hours) 744 5087 188535.5 Unit reserve shutdown hours 0 0 1 121.8 Net Electrical Energy (MWH) 524132 3616048 122759695 UNIT SHUTDOWNS (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Trip/Scram C - Refueling 3 - Automatic Trip/Scram 4 - Continuation D - Regulatory Restriction 5 - Other (Explain)
E - Operator Training/License Examination F - Administrative G - Operational Error (Explain)
H - Other Summary Of Monthly Operating Experience Unit 3 operated at essentially 100% for the month of July 2002.
DOCKET NO.: 50-251 UNIT: Turkey Point Unit 4 DATE: 8/5/2002 COMPLETED BY: Olga Hanek TELEPHONE: (305) 246-6607 Reporting Period July, 2002 Design Electrical Rating (MWe-Net) 720 Maximum Dependable Capacity (MWe-Net) 693 Month Year-to-date Cumulative No. of hours reactor was critical 744 4720.2 187689.7 No. of hours generator was on line (service hours) 744 4711.5 183286.6 Unit reserve shutdown hours 0 0 577.2 Net Electrical Energy (MWH) 519893 3286504 120391515 UNIT SHUTDOWNS No. Date Type Duration Reason Method of Corrective Action/ Comments F=Forced (hours) (1) Shutting S=Scheduled Down (2)
N/A N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual 2 - Manual Trip/Scram B - Maintenance or Test C - Refueling 3 - Automatic Trip/Scram D - Regulatory Restriction 4 - Continuation E - Operator Training/License Examination 5 - Other (Explain)
F - Administrative G - Operational Error (Explain)
H - Other Summary Of Monthly Operating Experience Unit 4 operated at essentially 100% for the month of July 2002.
Text
AUG 1 4 2002 FPL L-2002-158 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 Monthly Operating Report - July 2002 In accordance with the requirements of Turkey Point Units 3 and 4 Technical Specification 6.9.1.5, and the guidance of Generic Letter 97-02, attached are the July 2002 Operating Data Reports and Summaries of Operating Experience for Turkey Point Units 3 and 4.
Very truly yo/us, John P.J~Elwain Vice President Turkey Point Plant OIH Attachments NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC.
an FPL Group company
. J DOCKET NO.: 50-250 UNIT: Turkey Point Unit 3 DATE: 8/5/2002 COMPLETED BY: Olga Hanek TELEPHONE: (305) 246-6607 Reporting Period July, 2002 OPERATING DATA REPORT Design Electrical Rating (MWe-Net) 720 __........ _ .......
Maximum Dependable Capacity (MWe-Net) 693 _ _ _
Month Year-to-date Cumulative No. of hours reactor was critical 744 5087 190866.8 No. of hours generator was on line (service hours) 744 5087 188535.5 Unit reserve shutdown hours 0 0 1 121.8 Net Electrical Energy (MWH) 524132 3616048 122759695 UNIT SHUTDOWNS (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Trip/Scram C - Refueling 3 - Automatic Trip/Scram 4 - Continuation D - Regulatory Restriction 5 - Other (Explain)
E - Operator Training/License Examination F - Administrative G - Operational Error (Explain)
H - Other Summary Of Monthly Operating Experience Unit 3 operated at essentially 100% for the month of July 2002.
DOCKET NO.: 50-251 UNIT: Turkey Point Unit 4 DATE: 8/5/2002 COMPLETED BY: Olga Hanek TELEPHONE: (305) 246-6607 Reporting Period July, 2002 Design Electrical Rating (MWe-Net) 720 Maximum Dependable Capacity (MWe-Net) 693 Month Year-to-date Cumulative No. of hours reactor was critical 744 4720.2 187689.7 No. of hours generator was on line (service hours) 744 4711.5 183286.6 Unit reserve shutdown hours 0 0 577.2 Net Electrical Energy (MWH) 519893 3286504 120391515 UNIT SHUTDOWNS No. Date Type Duration Reason Method of Corrective Action/ Comments F=Forced (hours) (1) Shutting S=Scheduled Down (2)
N/A N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A - Equipment Failure (Explain) 1 - Manual 2 - Manual Trip/Scram B - Maintenance or Test C - Refueling 3 - Automatic Trip/Scram D - Regulatory Restriction 4 - Continuation E - Operator Training/License Examination 5 - Other (Explain)
F - Administrative G - Operational Error (Explain)
H - Other Summary Of Monthly Operating Experience Unit 4 operated at essentially 100% for the month of July 2002.