IE Insp Rept 50-302/79-47 on 791105-09.No Noncompliance Noted.Major Areas Inspected:Plant Operations & Followup on Previously Identified Items
ML19257D176
Person / Time
Site: Crystal River 
Issue date: 12/05/1979
From: Andrea Johnson, Robert Lewis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19257D173 List:
References
50-302-79-47, NUDOCS 8002010490
Download: ML19257D176 (3)


Text

9

[

'

UNITED STATES l'),

NUCLEAR REGULATORY COMMISSION

^

h'

101 MARtETTA ST N.W., SulTE 3100

., j REGION fl okh

ATLANTA, CEORGIA 30303 4 **

Report No 50-302/79-47 Licensee:

Florida Power Corporation 3201 34th Street, South St. Petersburg, Florida 33733 Facility Name: Crystal River 3 Docket No. 50-302 License No. DPR-72 inspected at Crystal River Site near Crystal River, Florida Inspected by:

6I-h4

. % M_,

/ 2/[/7)

A.H.Jopnson

/

Dat'e Signed Approved by:

,4 c'2 sEu g,k/

?gS(gne[d P. T. Burnett, Acting Section Chief, att

~

RONS Branch

.

SUMMARY Inspection on November 5-9, 1979 Areas Inspected This routine, unannounced inspection involved 27 inspector-hours onsite in the areas of plant operations and followup on previously identified items.

Results Of the 2 areas inspected, no apparent items of noncompliance or deviations were identified.

_

1855 054 0 970 800201

.

.

DETAILS 1.

Persons Contacted Licensee Employees

  • G. P. Beatty, Jr., Pir.nt Manager
  • J.

Cooper, QA/QC Manager

  • R. W. Kennedy, Compliance Supervisor
  • L. A. Hill, Compliance Auditor K. K. Lancaster, Compliacce Auditor L. B. Tittle, Performance /Results Engineer W. Stephensen, Plant Engineer Other licensee employees contacted included. shift supervisors and reactor operators.
  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on November 9, 1979 with those persons indicated in Paragraph 1 above.

The items described in these details were discussed, and the licensee acknowledged the inspector's comments.

3.

Licensee Action on Previous Inspection Findings (Closed) Dc iciency (302/79-12-01) Failure to follow procedure FP-302.

The licensee completely revised procedure FP-302 "New Fuel assembly unloading, Inspection, Storage and Container Reloading". This item is closed.

(Closed) Infraction (302/79-26-04) Failure to follow procedure SP-317

" Power Range Nuclear Instrumentation Calibration". The licensee conducted formal training and issued a policy letter stressing meeting the requirements of AI-600. This item is closed.

(Closed) Infraction (302/79-27-01) Failure to follow procedure CP-114 requiring PRC review of all modifications upon completion. The licensee revised CP-114 requiring PRC review of safety-related temporary modifications and PRC chairman verification that PRC reviewed post modification testing of temporary modifications. This item is closed.

(0 pen) Infraction (302/79-23-01) Failure to meet requalification training for backup licensed operators. The licensee revised procedure Al-800 to conform to the approved requalification program. The backup licensed operators have not completed their training, which is to be completed November 30, 1979.

This item will remain open pending completion of training.

1855 055

.

-

-2-(Closed) Unresolved Item (302/78-20-02) Non EP seals.

Gilbert / Commonwealth performed an engineering evaluation of the fif ty (50) snubbers having non EP seals and it was determined the expected lifetime to be forty years for the environment in which they are located. This item is closed.

4.

Unresolved Items Unresolved items were not ident.ified during this inspection.

5.

Licensee Action on Previously Identified Inspector Followup Items The inspector reviewed licensee action on previously identified items of concern through discussions with licensee personnel, and verification of the implementation of applicable corrective action.

The status of these items is indicated below:

a.

(Closed) IFI 79-21-01 Incorporotion of Limits and Temperature Correction inta SP-201 and MP-130. The inspector verified that procedures SP-201 and MP-130 were revised to include the items of concern.

The inspector has no further questions at this time, b.

(Closed) IFI 78-15-02 Evaluate the applicability of ANSI B30.2 on plant cranes. The inspector verified that procedure PM-109 " Inspection and Maintenance of Cranes and Hoists" was revised to include the missle shield trane and other plant cranes into the proctaure.

The inspector had no further questions at this time.

c.

(Closed) IFI 79-04-03 Complete Major Revisicn to CH3 Safety Listing.

The inspector verified that CR3 Safety Listing was issued and on site.

~he inspector had no further que4tions at this time.

6.

Review of Plant Operations Plant operations s:ere reviewed by the inspector to ascertain conformance with regulatory requirements and technical specifications, including review of shift supervisor and control operator logs, observing portions of control room activities, and touring the facility. No discrepancies were noted.

_